Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Neurosci Methods ; 369: 109481, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35032498

RESUMO

BACKGROUND: Intrafascicular electrical stimulation has been extensively adopted to achieve sensory feedback for limb amputees. Axon-like carbon nanotube yarn (CNTy) electrodes with both promising flexibility and spatial selectivity index (SSI) can be fascinating alternatives to generate artificial somatosensation. NEW METHOD: Here we systematically disclose objective neuromodulation basis for artificial somatosensation through intrafascicular CNTy electrodes. CNTy electrodes with different exposed lengths were utilized for electrically stimulating tibial nerves in twelve rats. Somatosensory evoked potentials (SEPs) were recorded synchronously using an epidural thirty-channel electrode array. Spatiotemporal characteristics of SEPs were analyzed as current pulse amplitude (PA), pulse width (PW) and pulse frequency (PF) varied. RESULTS: The current thresholds at 1 Hz exhibit the lowest means when compared with those at 4 and 8 Hz for most CNTy electrodes (20/28). For all the electrodes, amplitudes of SEPs and activated areas of perceptive fields increase with PWs and PAs rising, and decrease remarkably with PFs from 1 to 8 Hz. Latencies of P1 and N1 of SEP peaks gradually reduced with PWs and PAs advancing. Considering high SSIs, relatively stable current thresholds, wider variation ranges of sensory magnitudes and optimal stability of perceptive fields, the L-200 µm electrodes are preferable for neuromodulation with PFs of 1 - 8 Hz, PWs of 100 - 800 µs and PAs of 2 - 64 µA. COMPARISON WITH EXISTING METHODS: New-type CNTy electrodes possess both promising flexibility and SSI when compared with other neural interfaces. We systematically explore objective neuromodulation basis for artificial somatosensation through CNTy electrodes for the first time. CONCLUSIONS: Significantly higher SSIs, lower current and charge thresholds exist for CNTy electrodes in comparison with other peripheral-nerve interfaces. This study can, for the first time, lay a solid neuromodulation foundation for CNTy electrodes to achieve fine sensory feedback.


Assuntos
Nanotubos de Carbono , Animais , Estimulação Elétrica , Eletrodos , Eletrodos Implantados , Potenciais Somatossensoriais Evocados , Nervos Periféricos/fisiologia , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA