Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 31(Pt 3): 540-546, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619289

RESUMO

The soft X-ray photoelectron momentum microscopy (PMM) experimental station at the UVSOR Synchrotron Facility has been recently upgraded by additionally guiding vacuum ultraviolet (VUV) light in a normal-incidence configuration. PMM offers a very powerful tool for comprehensive electronic structure analyses in real and momentum spaces. In this work, a VUV beam with variable polarization in the normal-incidence geometry was obtained at the same sample position as the soft X-ray beam from BL6U by branching the VUV beamline BL7U. The valence electronic structure of the Au(111) surface was measured using horizontal and vertical linearly polarized (s-polarized) light excitations from BL7U in addition to horizontal linearly polarized (p-polarized) light excitations from BL6U. Such highly symmetric photoemission geometry with normal incidence offers direct access to atomic orbital information via photon polarization-dependent transition-matrix-element analysis.

2.
Rev Sci Instrum ; 94(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38065145

RESUMO

The photoelectron momentum microscope (PMM) in operation at BL6U, an undulator-based soft x-ray beamline at the UVSOR Synchrotron Facility, offers a new approach for µm-scale momentum-resolved photoelectron spectroscopy (MRPES). A key feature of the PMM is that it can very effectively reduce radiation-induced damage by directly projecting a single photoelectron constant energy contour in reciprocal space with a radius of a few Å-1 or real space with a radius of a few 100 µm onto a two-dimensional detector. This approach was applied to three-dimensional valence band structure E(k) and E(r) measurements ("stereography") as functions of photon energy (hν), its polarization (e), detection position (r), and temperature (T). In this study, we described some examples of possible measurement techniques using a soft x-ray PMM. We successfully applied this stereography technique to µm-scale MRPES to selectively visualize the single-domain band structure of twinned face-centered-cubic Ir thin films grown on Al2O3(0001) substrates. The photon energy dependence of the photoelectron intensity on the Au(111) surface state was measured in detail within the bulk Fermi surface. By changing the temperature of 1T-TaS2, we clarified the variations in the valence band dispersion associated with chiral charge-density-wave phase transitions. Finally, PMMs for valence band stereography with various electron analyzers were compared, and the advantages of each were discussed.

3.
Sci Rep ; 7(1): 12837, 2017 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-28993642

RESUMO

Structural and electronic properties of the SmB6(001) single-crystal surface prepared by Ar+ ion sputtering and controlled annealing are investigated by scanning tunneling microscopy. In contrast to the cases of cleaved surfaces, we observe a single phase surface with a non-reconstructed p(1 × 1) lattice on the entire surface at an optimized annealing temperature. The surface is identified as Sm-terminated on the basis of spectroscopic measurements. On a structurally uniform surface, the emergence of the in-gap state, a robust surface state against structural variation, is further confirmed inside a Kondo hybridization gap at 4.4 K by temperature and atomically-resolved spatial dependences of the differential conductance spectrum near the Fermi energy.

4.
J Synchrotron Radiat ; 24(Pt 2): 449-455, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28244439

RESUMO

A compact and portable magnet system for measuring magnetic dichroism in resonant inelastic soft X-ray scattering (SX-RIXS) has been developed at the beamline BL07LSU in SPring-8. A magnetic circuit composed of Nd-Fe-B permanent magnets, which realised ∼0.25 T at the center of an 11 mm gap, was rotatable around the axis perpendicular to the X-ray scattering plane. Using the system, a SX-RIXS spectrum was obtained under the application of the magnetic field at an angle parallel, nearly 45° or perpendicular to the incident X-rays. A dedicated sample stage was also designed to be as compact as possible, making it possible to perform SX-RIXS measurements at arbitrary incident angles by rotating the sample stage in the gap between the magnetic poles. This system enables facile studies of magnetic dichroism in SX-RIXS for various experimental geometries of the sample and the magnetic field. A brief demonstration of the application is presented.

5.
J Synchrotron Radiat ; 23(Pt 3): 735-42, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27140153

RESUMO

An angle-resolved linearly polarized hard X-ray photoemission spectroscopy (HAXPES) system has been developed to study the ground-state symmetry of strongly correlated materials. The linear polarization of the incoming X-ray beam is switched by a transmission-type phase retarder composed of two diamond (100) crystals. The best value of the degree of linear polarization was found to be -0.96, containing a vertical polarization component of 98%. A newly developed low-temperature two-axis manipulator enables easy polar and azimuthal rotations to select the detection direction of photoelectrons. The lowest temperature achieved was 9 K, offering the chance to access the ground state even for strongly correlated electron systems in cubic symmetry. A co-axial sample monitoring system with long-working-distance microscope enables the same region on the sample surface to be measured before and after rotation. Combining this sample monitoring system with a micro-focused X-ray beam by means of an ellipsoidal Kirkpatrick-Baez mirror (25 µm × 25 µm FWHM), polarized valence-band HAXPES has been performed on NiO for voltage application as resistive random access memory to demonstrate the micro-positioning technique and polarization switching.

6.
J Synchrotron Radiat ; 22(3): 776-80, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931096

RESUMO

Soft X-ray angle-resolved photoemission has been performed for metallic V2O3. By combining a microfocus beam (40 µm × 65 µm) and micro-positioning techniques with a long-working-distance microscope, it has been possible to observe band dispersions from tiny cleavage surfaces with a typical size of several tens of µm. The photoemission spectra show a clear position dependence, reflecting the morphology of the cleaved sample surface. By selecting high-quality flat regions on the sample surface, it has been possible to perform band mapping using both photon-energy and polar-angle dependences, opening the door to three-dimensional angle-resolved photoemission spectroscopy for typical three-dimensional correlated materials where large cleavage planes are rarely obtained.

7.
J Synchrotron Radiat ; 18(Pt 6): 879-84, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21997912

RESUMO

A system for angle-resolved photoemission spectroscopy (ARPES) of small single crystals with sizes down to 100 µm has been developed. Soft X-ray synchrotron radiation with a spot size of ∼40 µm × 65 µm at the sample position is used for the excitation. Using this system an ARPES measurement has been performed on a Si crystal of size 120 µm × 100 µm × 80 µm. The crystal was properly oriented on a sample stage by measuring the Laue spots. The crystal was cleaved in situ with a microcleaver at 100 K. The cleaved surface was adjusted to the beam spot using an optical microscope. Consequently, clear band dispersions along the Γ-X direction reflecting the bulk electronic states were observed with a photon energy of 879 eV.

8.
Rev Sci Instrum ; 80(5): 053901, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19485514

RESUMO

A method to position samples with small cleaved regions has been developed to be applied to the angle-resolved photoemission spectroscopy (ARPES) which uses soft-x-ray synchrotron radiation focused down to 160 x 180 microm(2). A long-working-distance optical microscope is used for the sample observation. A selected region on a sample can be optimally set at the position of measurements, which is realized by the spatial resolution of the photoelectron analyzer. Using this method, electronic band dispersions of bulk silicon have been measured by ARPES for a partially cleaved region with a size of approximately 200 x 500 microm(2).

9.
Phys Rev Lett ; 101(8): 086404, 2008 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-18764646

RESUMO

We have synthesized a new spinel oxide LiRh2O4 with a mixed-valent configuration of Rh3+ and Rh4+. At room temperature, it is a paramagnetic metal, but on cooling, a metal-insulator transition occurs and a valence bond solid state is formed below 170 K. We argue that the formation of valence bond solid is promoted by a band Jahn-Teller transition at 230 K and the resultant confinement of t_{2g} holes within the xy band. The band Jahn-Teller instability is also responsible for the observed enhanced thermoelectric power in the orbital-disordered phase above 230 K.

10.
J Synchrotron Radiat ; 9(Pt 4): 233-6, 2002 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-12091732

RESUMO

The electronic structure of Heusler-type Fe(2)VAl has been studied by high-resolution photoelectron spectroscopy with the excitation photon energy hnu ranging from 21.2 eV (the He I laboratory light source) to 904 eV (the soft X-ray synchrotron light source) for clean surfaces prepared by scraping or fracturing polycrystalline and single crystalline specimens. Photoelectron spectra recorded for the fractured surfaces show a 10 eV-wide valence band with fine structures and a clear decrease in the intensity towards the Fermi level E(F), while a high intensity at E(F) and no fine structures are observed for the scraped surface. Comparison with the theoretical density of states (DOS) indicates that the vacuum ultraviolet photoelectron spectra emphasize the transition-metal 3d bands but the soft X-ray photoelectron spectra agree remarkably well with the DOS including the fine structures and the pseudogap at E(F). The present results suggest that the electronic structure of Fe(2)VAl is highly sensitive to possible strain and defects induced by scraping. Bulk electronic structures of Fe(2)VAl are discussed in relation to the reported fascinating transport properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA