Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Curr Probl Cardiol ; 49(1 Pt A): 102012, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37549814

RESUMO

Transcatheter aortic valve implantation (TAVI) has increasingly been utilized in patients with aortic insufficiency (AI) with insufficient data on its safety. The Nationwide Readmissions Database (NRD) was queried to identify patients undergoing TAVI for AI. Net clinical events (composite of in-hospital mortality, stroke, major bleeding) and procedural complications were assessed using a propensity-score matched (PSM) analysis to calculate adjusted odds ratios (OR). A total of 185,703 (AI 3873, aortic stenosis [AS] 181,830) patients were included in the analysis. Due to a significant difference in the baseline characteristics, a matched sample of 7929 patients (AI 3873, AS 4056) was selected. At index admission, the adjusted odds of in-hospital NACE (aOR 2.0, 95% CI 1.59-2.51), mortality (aOR 3.06, 95% CI 2.38-5.47), major bleeding (aOR 1.53, 95% CI 1.13-2.06) and valvular complications (aOR 9.48, 95% CI 6.73-13.38) were significantly higher in patients undergoing TAVI for AI compared with those undergoing TAVI for AS. However, there was no significant difference in the incidence of NACE, mortality, stroke, major bleeding, and need for permanent pacemaker implantation at 30- and 180-days follow-up. TAVI in AI was associated with a higher risk of periprocedural NACE, mortality, and major bleeding. The risk of these complications attenuated at 30- and 180-day readmission.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Readmissão do Paciente , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Hemorragia/etiologia , Valva Aórtica/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
2.
Int J Cardiol Heart Vasc ; 42: 101119, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36161232

RESUMO

Background: Heart failure (HF) is a complex clinical syndrome with symptoms and signs that result from any structural or functional impairment of ventricular filling or ejection of blood. Limited data is available regarding the in-hospital outcomes of TAVR compared to SAVR in the octogenarian population with HF. Methods: The National Inpatient Sample (NIS) database was used to compare TAVR versus SAVR among octogenarians with HF. The primary outcome was in-hospital mortality. The secondary outcome included acute kidney injury (AKI), cerebrovascular accident (CVA), post-procedural stroke, major bleeding, blood transfusions, sudden cardiac arrest (SCA), cardiogenic shock (CS), and mechanical circulatory support (MCS). Results: A total of 74,995 octogenarian patients with HF (TAVR-HF n = 64,890 (86.5%); SAVR n = 10,105 (13.5%)) were included. The median age of patients in TAVR-HF and SAVR-HF was 86 (83-89) and 82 (81-84) respectively. TAVR-HF had lower percentage in-hospital mortality (1.8% vs. 6.9%;p < 0.001), CVA (2.5% vs. 3.6%; p = 0.009), SCA (9.9% vs. 20.2%; p < 0.001), AKI (17.4% vs. 40.8%); p < 0.001), major transfusion (26.4% vs 67.3%; p < 0.001), CS (1.8% vs 9.8%; p < 0.001), and MCS (0.8% vs 7.3%; p < 0.001) when compared to SAVR-HF. Additionally, post-procedural stroke and major bleeding showed no significant difference. The median unmatched total charges for TAVR-HF and SAVR-HF were 194,561$ and 246,100$ respectively. Conclusion: In this nationwide observational analysis, TAVR is associated with an improved safety profile for octogenarians with heart failure (both preserved and reduced ejection fraction) compared to SAVR.

3.
Expert Rev Cardiovasc Ther ; 20(2): 151-160, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35172121

RESUMO

BACKGROUND: Inaccurate sizing of left atrial appendage (LAA) occlusion devices is associated with increased stroke risk. We compared the LAA size to implant the Watchman device assessed by computed tomography (CT) to transesophageal echocardiography (TEE). METHODS: Databases were searched to identify studies comparing LAA anatomical measurements and procedural outcomes across imaging modalities for the Watchman device implantation. RESULTS: Seven studies were included in the analysis (242 patients on TEE, and 232 on CT). The LAA orifice was larger when sized with CT compared to TEE (CT mean vs TEE SMD 0.30 mm, 95%CI 0.09-0.51 mm, P < 0.01; and CT max vs TEE SMD 0.69 mm, 95%CI 0.51-0.87 mm, P < 0.001). Additionally, CT, including CT-based 3-dimensional models, had higher odds of predicting correct device size compared to TEE (OR 1.64; 95%CI 1.05-2.56; P = 0.03). CT resulted in a lower fluoroscopy time vs TEE (SMD -0.78 min, 95% CI -1.39 to -0.18, P = 0.012). No significant differences were found in device clinical outcomes. CONCLUSION: Compared to TEE, CT resulted in larger LAA orifice measurements, improved odds of predicting correct device size, and reduced fluoroscopy time in patients undergoing LAA occlusion with the Watchman device. There were no significant differences in other procedural outcomes.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Humanos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 99(4): 1319-1326, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35043555

RESUMO

BACKGROUND: The relative merits of the drug-coated balloon (DCB) versus uncoated balloon (UCB) angioplasty in endovascular intervention for patients with symptomatic lower extremity peripheral arterial disease (PAD) remains controversial. METHODS: Online databases were queried with various combinations of keywords to identify relevant articles. Net adverse events (NAEs) and its components were compared using a random effect model to calculate unadjusted odds ratios (ORs). RESULTS: A total of 26 studies comprising 26,845 patients (UCB: 17,770 and DCB: 9075) were included. On pooled analysis, DCB was associated with significantly lower odds of NAE (OR: 0.47, 95% confidence interval [CI]: 0.36-0.61), vessel restenosis (OR: 0.46, 95% CI: 0.37-0.57), major amputation (OR: 0.68, 95% CI: 0.47-99), need for repeat target lesion (OR: 0.38, 95% CI: 0.31-0.47) and target vessel revascularization (OR: 0.62, 95% CI: 0.47-0.81) compared with UCB. Similarly, the primary patency rate was significantly higher in patients undergoing DCB angioplasty (OR: 1.44, 95% CI: 1.19-1.75), while the odds for all-cause mortality (OR: 0.96, 95% CI: 0.85-1.09) were not significantly different between the two groups. A subgroup analysis based on follow-up duration (6 months vs. 1 vs. 2 years) followed the findings of the pooled analysis with few exceptions. CONCLUSIONS: The use of DCB in lower extremity PAD intervention is associated with higher primary patency, lower restenosis, lower amputation rate, and decreased need for repeat revascularization with similar all-cause mortality as compared to UCB.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Constrição Patológica/etiologia , Artéria Femoral , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
Ann Med Surg (Lond) ; 84: 104846, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37034272

RESUMO

Background: We aim to conduct a comprehensive meta-analysis encompassing all studies to assess the efficacy of Vascepa in patients with diabetes mellitus (DM) in preventing or treating existing coronary artery disease (CAD). Methods: Digital databases were queried. Odds ratios (OR) were calculated for the following outcomes: composite outcome, all-cause mortality, and cardiovascular mortality. Results: A total of 4 randomized control trials (33,092 patients; Vascepa n = 16586; Placebo n = 16506) were included in our analysis. The overall mean age was 64.3 years old (Vascepa = 64.3 years; Placebo = 64.3 years). The sample was 61.5% male (Vascepa = 60.8%; Placebo = 62.1%). In patients with DM, Vascepa was found to have no significant effect on the primary composite outcome (OR 0.97, 95%CI 0.91-1.04, p > 0.05), all-cause mortality (OR 0.96, 95%CI 0.90-1.03, p > 0.05), and cardiovascular mortality (OR 0.90, 95%CI 0.74-1.10, p > 0.05). Subgroup analysis by Vascepa type and treatment type was similarly non-significant. Conclusion: Our study concluded that Vascepa did not affect cardiovascular outcomes in patients with DM.

6.
J Family Community Med ; 28(3): 175-180, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34703377

RESUMO

BACKGROUND: The self-rated health of Arab Americans has been found to be worse than non-Hispanic whites. Psychosocial factors such as stress and acculturation may explain this disparity. As a result, we designed this survey to better understand the effects of stress and acculturation on the self-rated health of the Arab-American community. MATERIALS AND METHODS: Using a convenience sample, we surveyed 142 self-identified Arab Americans regarding demographics, stress, acculturation, and self-rated health. Stress was measured using instruments assessing perceived stress, everyday discrimination, and acculturative stress. Acculturation was measured using a modified Vancouver Index of Acculturation. To measure self-rated health, participants were asked to rate their current health on a scale of 1 (very poor) to 5 (very good). RESULTS: A logistic regression model adjusted for age, sex, body mass index, and education did not find that stress significantly affected the odds of having poor self-rated health in Arab Americans. Heritage identity was associated with lower odds of having poor self-rated health (odds ratio = 0.37, 95% confidence interval [CI] 0.15, 0.94, P < 0.05). No association was found between acculturation and poor self-rated health. CONCLUSION: Greater levels of stress were not significantly associated with greater odds of poor self-rated health in Arab Americans. We also found that greater heritage identity significantly decreased the odds of poor self-rated health in Arab Americans. The effects of everyday discrimination, perceived stress, and acculturation on self-rated health in Arab Americans remain unclear and need to be examined further.

7.
Artigo em Inglês | MEDLINE | ID: mdl-34567456

RESUMO

The clinical efficacy of remote dielectric sensing (ReDS) monitoring is not well known. Digital databases were searched to identify relevant articles. Pooled unadjusted odds ratio (OR) for dichotomous outcomes were calculated using a random-effects model. Findings were reported as a point estimate with its 95% confidence interval (CI). A total of 985 patients across seven studies were included in the meta-analysis. Patients with heart failure monitored with ReDS had significantly lower odds of hospital readmission compared with non-ReDS patients (OR = 0.40; 95% CI 0.29-0.56; z = 5.43 p = 0.000, I2 = 0%). Subgroup analysis based on the duration of follow-up showed a lower odd of readmission within 30 days (OR = 0.36; 95% CI 0.18-0.71; z = 2.93; p = 0.003; I2 5.7%), as well as between 1 and 3 months (OR = 0.42; 95% CI 0.29-0.61; z = 4.54; p = 0.000; I2 = 0.0%). ReDS effect of lower readmissions of HF was observed irrespective of the duration of follow-up (<1-month vs 1-3 months). ReDS monitoring significantly lowers the odds of HF readmission within 3 months compared to participants not using ReDS.

8.
Catheter Cardiovasc Interv ; 98(6): E802-E813, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34510705

RESUMO

INTRODUCTION: The relative safety and efficacy of polymer-free (PF) versus polymer-coated (PC) drug-eluting stents (DES) in patients with angina or acute coronary syndrome (ACS) undergoing percutaneous coronary intervention has received limited study. METHOD: Digital databases were queried to identify relevant studies. Major adverse cardiovascular events (MACE) and secondary outcomes were compared using a random effect model to calculate unadjusted odds ratios (OR). RESULTS: A total of 28 studies consisting of 23,198 patients were included in the final analysis. On pooled analysis, there was no significant difference in the odds of MACE (OR 0.98, 95% CI 0.91-1.08) and major bleeding (OR 0.87, 95% CI 0.61-1.24) between patients undergoing PF-DES versus PC-DES. Similarly, the odds of myocardial infarction, stroke, stent thrombosis, cardiovascular mortality and need for target vessel revascularization was similar between the two groups. PF-DES was favored due to significantly lower odds of non-cardiac death (OR 0.78, 95% CI 0.68-89) and all-cause mortality (OR 0.87, 95% CI 0.80-0.95), but had a higher need for target lesion revascularization (OR 1.2, 95% CI 1.02-1.42). A subgroup analysis based on follow up duration, clinical presentation, presence of diabetes and class of eluting drugs mirrored the net estimates for all outcomes with a few exceptions. A sensitivity and meta-regression analysis showed no influence of single-study and duration of antiplatelet therapy on pooled outcomes. CONCLUSION: In patients presenting with angina or ACS, PF-DES might be favored due to lower all-cause mortality and equal risk of ischemic adverse cardiovascular and major bleeding events compared with PC-DES.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
9.
High Blood Press Cardiovasc Prev ; 28(4): 405-416, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34181203

RESUMO

INTRODUCTION: The safety of renin-angiotensin-aldosterone system inhibitors (RAASi) among COVID-19 patients has been controversial since the onset of the pandemic. METHODS: Digital databases were queried to study the safety of RAASi in COVID-19. The primary outcome of interest was mortality. The secondary outcome was seropositivity improvement/viral clearance, clinical manifestation progression, and progression to intensive care units. A random-effect model was used to compute an unadjusted odds ratio (OR). RESULTS: A total of 49 observational studies were included in the analysis consisting of 83,269 COVID-19 patients (RAASi n = 34,691; non-RAASi n = 48,578). The mean age of the sample was 64, and 56% were males. We found that RAASi was associated with similar mortality outcomes as compared to non-RAASi groups (OR 1.07; 95% CI 0.99-1.15; p > 0.05). RAASi was associated with seropositivity improvement including negative RT-PCR or antibodies, (OR 0.96; 95% CI 0.93-0.99; p < 0.05). There was no association between RAASi versus control with progression to ICU admission (OR 0.99; 95% CI 0.79-1.23; p > 0.05) or higher odds of worsening of clinical manifestations (OR 1.04; 95% CI 0.97-1.11; p > 0.05). Metaregression analysis did not change our outcomes for effect modifiers including age, sex, comorbidities, RAASi type, or study type on outcomes. CONCLUSIONS: COVID-19 is not a contraindication to hold or discontinue RAASi as they are not associated with higher mortality or worsening symptoms. Continuation of RAASi might be associated with favorable outcomes in COVID-19, including seropositivity/viral clearance.


Assuntos
Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , COVID-19/virologia , Sistema Renina-Angiotensina/efeitos dos fármacos , SARS-CoV-2/patogenicidade , Idoso , Antagonistas de Receptores de Angiotensina/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , COVID-19/diagnóstico , COVID-19/mortalidade , COVID-19/fisiopatologia , Contraindicações de Medicamentos , Progressão da Doença , Feminino , Interações Hospedeiro-Patógeno , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco
10.
BMJ Case Rep ; 14(5)2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980559

RESUMO

Visine eye drops are a commonly used topical drug for irritation of the eye. The active component in Visine eye drops is tetrahydrozoline. Tetrahydrozoline is an imidazoline derivative found in several ophthalmic and nasal decongestants. Exposure is common in young children, who unintentionally ingest it, but cases have been rising in the adult population. The main systemic effects are bradycardia and hypotension due to activation of the central alpha-adrenergic receptors. In this case report, a 76-year-old man presents with bradycardia after 24 hours following ingestion of 120 mL of 0.05% tetrahydrozoline (eight bottles of Visine eye drops) in a suicide attempt. His initial ECG demonstrated complete heart block and QT prolongation. Subsequent ECGs showed unremitting first-degree atrioventricular block and QT prolongation. Here, we are presenting the first case of complete heart block following tetrahydrozoline consumption.


Assuntos
Bloqueio Atrioventricular , Adulto , Idoso , Bloqueio Atrioventricular/induzido quimicamente , Criança , Pré-Escolar , Ingestão de Alimentos , Eletrocardiografia , Humanos , Imidazóis , Masculino , Soluções Oftálmicas
11.
BMJ Open Qual ; 10(1)2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33731483

RESUMO

OBJECTIVES: To introduce surgical safety checklists and time outs to future physicians through early incorporation of time outs in the first year gross anatomy course. SETTING: The Wayne State University School of Medicine Anatomy Lab. PARTICIPANTS: Approximately 300 first year medical students per year participated in the intervention. INTERVENTIONS: An educational presentation on medical errors focusing on surgical errors was developed. Students in 2017-2018 viewed the presentation and completed two time outs, one with the first anatomy dissection and a second with the last dissection. Preintervention and postintervention surveys were completed and results compared. Students completed a second postintervention survey after the second time out. Students in 2018-2019 were asked to complete the time outs before every dissection. Time out procedure sheets were collected to determine completion rates. The intervention was further modified for academic year 2019-2020 and time out sheets were again collected. OUTCOME MEASURES: Four domains of learning were surveyed: (1) major components and goals/limitations of universal protocol, (2) medical error lexicon, (3) components of a time out, and (4) confidence in completing time out checklists. RESULTS: Postintervention surveys demonstrated significant improvement in each domain. Students found time outs easy to complete and developed confidence in performing time outs. Following a successful pilot, time outs were incorporated into every dissection. Students continued to perform this procedure despite absence of adverse consequences for not doing so. CONCLUSION: Students found the time outs easy to complete and developed the confidence and ability to perform a surgical time out early in their medical education. The new skills, knowledge and attitudes that these medical students have developed will hopefully improve the care they provide to patients, thereby advancing the practice of quality improvement and patient safety in the clinical setting.


Assuntos
Educação de Graduação em Medicina , Estudantes de Medicina , Time Out na Assistência à Saúde , Currículo , Humanos , Segurança do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA