Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JASA Express Lett ; 2(9): 094403, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36182337

RESUMO

This study investigated the number of channels required for asymptotic speech recognition for ten pediatric cochlear implant (CI) recipients with precurved electrode arrays. Programs with 4-22 active electrodes were used to assess word and sentence recognition in noise. Children demonstrated significant performance gains up to 12 electrodes for continuous interleaved sampling (CIS) and up to 22 channels with 16 maxima. These data are consistent with the latest adult CI studies demonstrating that modern CI recipients have access to more than 8 independent channels and that both adults and children exhibit performance gains up to 22 channels.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Criança , Humanos , Ruído , Fala
2.
Hear Res ; 426: 108584, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35985964

RESUMO

Cochlear implantation with acoustic hearing preservation is becoming increasingly prevalent allowing cochlear implant (CI) users to combine electric and acoustic stimulation (EAS) in the implanted ears. Despite a growing EAS population, our field does not have definitive guidance regarding EAS technology optimization and the majority of previous studies investigating hearing aid (HA) and cochlear implant (CI) programming for EAS listeners have been mixed. Thus, the purpose of this exploratory study was to explore the effects of various EAS crossover frequencies-defined as the low-frequency (LF) CI cutoff-relative to the underlying spiral ganglion (SG) characteristic frequency associated with the most distal or apical electrode in the array. Speech recognition in semi-diffuse noise and subjective estimates of listening difficulty were measured for 15 adult CI recipients with acoustic hearing preservation in three listening conditions: 1) CI-alone, 2) bimodal (CI+HA), and best-aided EAS (CIHA+HA). The results showed no effect of LF CI cutoff for any of the three listening conditions such that there was no trend for increased performance or less subjective listening difficulty across LF CI cutoffs, referenced to underlying SG-place frequency. Consistent with past studies, the current results were also consistent with significant speech recognition and subject listening difficulty benefits for both bimodal (CI+HA) and best-aided EAS (CIHA+HA) as compared to CI-alone listening as well as significant additional benefits for best-aided EAS (CIHA+HA) compared to bimodal hearing (CI+HA). Future studies are necessary to investigate the efficacy of SG-place-based fittings for i) large samples of experienced EAS listeners for whom perceptual adaptation has occurred to the frequency mismatch provided by standard CI frequency allocations, and ii) EAS users at or close to CI activation as place-based approaches may ultimately yield greater outcomes, particularly for newly activated CI users for whom SG-place-based approaches may afford a steeper trajectory to performance asymptote.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Estimulação Acústica/métodos , Percepção da Fala/fisiologia , Estimulação Elétrica/métodos , Acústica
3.
Biomed Phys Eng Express ; 9(1)2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-36594887

RESUMO

Objective. The cochlear implant is a neural prosthesis designed to directly stimulate auditory nerve fibers to induce the sensation of hearing in those experiencing severe-to-profound hearing loss. After surgical implantation, audiologists program the implant's external processor with settings intended to produce optimal hearing outcomes. The likelihood of achieving optimal outcomes increases when audiologists have access to tools that objectively present information related to the patient's own anatomy and surgical outcomes. This includes visualizations like the one presented here, termed the activation region overlap image, which is designed to decrease subjectivity when determining amounts of overlapping stimulation between implant electrodes.Approach. This visualization uses estimates of electric field strength to indicate spread of neural excitation due to each electrode. Unlike prior visualizations, this method explicitly defines regions of nerves receiving substantial stimulation from each electrode to help clinicians assess the presence of significant overlapping stimulation. A multi-reviewer study compared this and an existing technique on the consistency, efficiency, and optimality of plans generated from each method. Statistical significance was evaluated using the two-sided Wilcoxon rank sum test.Main results. The study showed statistically significant improvements in consistency (p < 10-12), efficiency (p < 10-15), and optimality (p < 10-5) when generating plans using the proposed method versus the existing method.Significance. This visualization addresses subjectivity in assessing overlapping stimulation between implant electrodes, which currently relies on reviewer estimates. The results of the evaluation indicate the provision of such objective information during programming sessions would likely benefit clinicians in making programming decisions.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Eletrodos Implantados
4.
J Am Acad Audiol ; 31(7): 506-512, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32119817

RESUMO

BACKGROUND: Despite improvements in cochlear implant (CI) technology, pediatric CI recipients continue to have more difficulty understanding speech than their typically hearing peers in background noise. A variety of strategies have been evaluated to help mitigate this disparity, such as signal processing, remote microphone technology, and microphone placement. Previous studies regarding microphone placement used speech processors that are now dated, and most studies investigating the improvement of speech recognition in background noise included adult listeners only. PURPOSE: The purpose of the present study was to investigate the effects of microphone location and beamforming technology on speech understanding for pediatric CI recipients in noise. RESEARCH DESIGN: A prospective, repeated-measures, within-participant design was used to compare performance across listening conditions. STUDY SAMPLE: A total of nine children (aged 6.6 to 15.3 years) with at least one Advanced Bionics CI were recruited for this study. DATA COLLECTION AND ANALYSIS: The Basic English Lexicon Sentences and AzBio Sentences were presented at 0o azimuth at 65-dB SPL in +5 signal-to-noise ratio noise presented from seven speakers using the R-SPACE system (Advanced Bionics, Valencia, CA). Performance was compared across three omnidirectional microphone configurations (processor microphone, T-Mic 2, and processor + T-Mic 2) and two directional microphone configurations (UltraZoom and auto UltraZoom). The two youngest participants were not tested in the directional microphone configurations. RESULTS: No significant differences were found between the various omnidirectional microphone configurations. UltraZoom provided significant benefit over all omnidirectional microphone configurations (T-Mic 2, p = 0.004, processor microphone, p < 0.001, and processor microphone + T-Mic 2, p = 0.018) but was not significantly different from auto UltraZoom (p = 0.176). CONCLUSIONS: All omnidirectional microphone configurations yielded similar performance, suggesting that a child's listening performance in noise will not be compromised by choosing the microphone configuration best suited for the child. UltraZoom (adaptive beamformer) yielded higher performance than all omnidirectional microphones in moderate background noise for adolescents aged 9 to 15 years. The implications of these data suggest that for older children who are able to reliably use manual controls, UltraZoom will yield significantly higher performance in background noise when the target is in front of the listener.


Assuntos
Implantes Cocleares , Percepção da Fala , Adolescente , Adulto , Criança , Humanos , Estudos Prospectivos , Fala , Tecnologia
5.
Trends Hear ; 22: 2331216518771176, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29716437

RESUMO

Adult cochlear implant (CI) recipients demonstrate a reliable relationship between spectral modulation detection and speech understanding. Prior studies documenting this relationship have focused on postlingually deafened adult CI recipients-leaving an open question regarding the relationship between spectral resolution and speech understanding for adults and children with prelingual onset of deafness. Here, we report CI performance on the measures of speech recognition and spectral modulation detection for 578 CI recipients including 477 postlingual adults, 65 prelingual adults, and 36 prelingual pediatric CI users. The results demonstrated a significant correlation between spectral modulation detection and various measures of speech understanding for 542 adult CI recipients. For 36 pediatric CI recipients, however, there was no significant correlation between spectral modulation detection and speech understanding in quiet or in noise nor was spectral modulation detection significantly correlated with listener age or age at implantation. These findings suggest that pediatric CI recipients might not depend upon spectral resolution for speech understanding in the same manner as adult CI recipients. It is possible that pediatric CI users are making use of different cues, such as those contained within the temporal envelope, to achieve high levels of speech understanding. Further investigation is warranted to investigate the relationship between spectral and temporal resolution and speech recognition to describe the underlying mechanisms driving peripheral auditory processing in pediatric CI users.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial/reabilitação , Percepção da Fala/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Auxiliares de Audição , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/fisiopatologia , Humanos , Pessoa de Meia-Idade , Fala , Medida da Produção da Fala , Adulto Jovem
6.
J Speech Lang Hear Res ; 61(5): 1306-1321, 2018 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-29800361

RESUMO

Purpose: The primary purpose of this study was to assess speech understanding in quiet and in diffuse noise for adult cochlear implant (CI) recipients utilizing bimodal hearing or bilateral CIs. Our primary hypothesis was that bilateral CI recipients would demonstrate less effect of source azimuth in the bilateral CI condition due to symmetric interaural head shadow. Method: Sentence recognition was assessed for adult bilateral (n = 25) CI users and bimodal listeners (n = 12) in three conditions: (1) source location certainty regarding fixed target azimuth, (2) source location uncertainty regarding roving target azimuth, and (3) Condition 2 repeated, allowing listeners to turn their heads, as needed. Results: (a) Bilateral CI users exhibited relatively similar performance regardless of source azimuth in the bilateral CI condition; (b) bimodal listeners exhibited higher performance for speech directed to the better hearing ear even in the bimodal condition; (c) the unilateral, better ear condition yielded higher performance for speech presented to the better ear versus speech to the front or to the poorer ear; (d) source location certainty did not affect speech understanding performance; and (e) head turns did not improve performance. The results confirmed our hypothesis that bilateral CI users exhibited less effect of source azimuth than bimodal listeners. That is, they exhibited similar performance for speech recognition irrespective of source azimuth, whereas bimodal listeners exhibited significantly poorer performance with speech originating from the poorer hearing ear (typically the nonimplanted ear). Conclusions: Bilateral CI users overcame ear and source location effects observed for the bimodal listeners. Bilateral CI users have access to head shadow on both sides, whereas bimodal listeners generally have interaural asymmetry in both speech understanding and audible bandwidth limiting the head shadow benefit obtained from the poorer ear (generally the nonimplanted ear). In summary, we found that, in conditions with source location uncertainty and increased ecological validity, bilateral CI performance was superior to bimodal listening.


Assuntos
Implantes Cocleares , Compreensão , Movimentos da Cabeça , Perda Auditiva/reabilitação , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Perda Auditiva/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Psicoacústica , Localização de Som , Incerteza
7.
Otol Neurotol ; 39(4): 422-427, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29533331

RESUMO

OBJECTIVE: Evaluate performance and quality of life changes after sequential bilateral cochlear implantation in patients with preoperative residual hearing functioning in a bimodal hearing configuration. STUDY DESIGN: Retrospective analysis using within-subjects repeated measures design. SETTING: Tertiary otologic center. PATIENTS: Twenty-two adult patients with bilateral sensorineural hearing loss who used bimodal hearing before second cochlear implant (CI) meeting the following criteria: 1) preoperative residual hearing (≤80 dB HL at 250 Hz) in the ear to be implanted, 2) implantation with current CI technology (2013-2016), 3) consonant-nucleus-consonant (CNC) speech recognition testing in the bimodal condition preoperatively and bilateral CI condition postoperatively. INTERVENTION: Cochlear implantation. MAIN OUTCOME MEASURES: CNC and AzBio sentence scores in quiet and noise (+5 SNR). Subjective measures of communication difficulty and sound quality were also administered. RESULTS: Twenty-two patients (mean 64 yr, 68% men) were included. At an average follow-up of 11.8 months, CNC scores in the bilateral CI condition (mean 63%, standard deviation [SD] = 22) were significantly better than preoperative bimodal scores with repeated measures analysis (mean 55%, SD = 22) (p = 0.03). AzBio scores in quiet were also higher with bilateral CI (mean 76%, SD = 24) compared with bimodal listening (mean 69%, SD = 29) (p = 0.0007). Global abbreviated profile of hearing aid benefit (APHAB) and overall speech, spatial, and qualities of hearing (SSQ) scores exhibited significant improvement following bilateral implantation (p = 0.006 for both analyses). CONCLUSIONS: For patients using a bimodal hearing configuration with substantial residual hearing in the non-CI ear, bilateral cochlear implantation yields improved audiologic performance and better subjective quality of life, irrespective of the ability to preserve acoustic hearing during the second sided implantation.


Assuntos
Implante Coclear/métodos , Perda Auditiva Bilateral/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Audição , Qualidade de Vida , Adulto , Idoso , Implantes Cocleares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Trends Hear ; 22: 2331216518755288, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29441835

RESUMO

Considerable advancements in cochlear implant technology (e.g., electric acoustic stimulation) and assessment materials have yielded expanded criteria. Despite this, it is unclear whether individuals with better audiometric thresholds and speech understanding are being referred for cochlear implant workup and pursuing cochlear implantation. The purpose of this study was to characterize the mean auditory and demographic profile of adults presenting for preoperative cochlear implant workup. Data were collected prospectively for all adult preoperative workups at Vanderbilt from 2013 to 2015. Subjects included 287 adults (253 postlingually deafened) with a mean age of 62.3 years. Each individual was assessed using the minimum speech test battery, spectral modulation detection, subjective questionnaires, and cognitive screening. Mean consonant-nucleus-consonant word scores, AzBio sentence scores, and pure-tone averages for postlingually deafened adults were 10%, 13%, and 89 dB HL, respectively, for the ear to be implanted. Seventy-three individuals (25.4%) met labeled indications for Hybrid-L and 207 individuals (72.1%) had aidable hearing in the better hearing ear to be used in a bimodal hearing configuration. These results suggest that mean speech understanding evaluated at cochlear implant workup remains very low despite recent advancements. Greater awareness and insurance accessibility may be needed to make cochlear implant technology available to those who qualify for electric acoustic stimulation devices as well as individuals meeting conventional cochlear implant criteria.


Assuntos
Implantes Cocleares , Perda Auditiva , Percepção da Fala , Adulto , Implante Coclear , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Ear Hear ; 38(5): 539-553, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28301392

RESUMO

OBJECTIVE: The primary objective of this study was to assess the effect of electric and acoustic overlap for speech understanding in typical listening conditions using semidiffuse noise. DESIGN: This study used a within-subjects, repeated measures design including 11 experienced adult implant recipients (13 ears) with functional residual hearing in the implanted and nonimplanted ear. The aided acoustic bandwidth was fixed and the low-frequency cutoff for the cochlear implant (CI) was varied systematically. Assessments were completed in the R-SPACE sound-simulation system which includes a semidiffuse restaurant noise originating from eight loudspeakers placed circumferentially about the subject's head. AzBio sentences were presented at 67 dBA with signal to noise ratio varying between +10 and 0 dB determined individually to yield approximately 50 to 60% correct for the CI-alone condition with full CI bandwidth. Listening conditions for all subjects included CI alone, bimodal (CI + contralateral hearing aid), and bilateral-aided electric and acoustic stimulation (EAS; CI + bilateral hearing aid). Low-frequency cutoffs both below and above the original "clinical software recommendation" frequency were tested for all patients, in all conditions. Subjects estimated listening difficulty for all conditions using listener ratings based on a visual analog scale. RESULTS: Three primary findings were that (1) there was statistically significant benefit of preserved acoustic hearing in the implanted ear for most overlap conditions, (2) the default clinical software recommendation rarely yielded the highest level of speech recognition (1 of 13 ears), and (3) greater EAS overlap than that provided by the clinical recommendation yielded significant improvements in speech understanding. CONCLUSIONS: For standard-electrode CI recipients with preserved hearing, spectral overlap of acoustic and electric stimuli yielded significantly better speech understanding and less listening effort in a laboratory-based, restaurant-noise simulation. In conclusion, EAS patients may derive more benefit from greater acoustic and electric overlap than given in current software fitting recommendations, which are based solely on audiometric threshold. These data have larger scientific implications, as previous studies may not have assessed outcomes with optimized EAS parameters, thereby underestimating the benefit afforded by hearing preservation.


Assuntos
Implantes Cocleares , Percepção da Fala , Estimulação Acústica , Adulto , Idoso , Estimulação Elétrica , Feminino , Audição , Auxiliares de Audição , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Razão Sinal-Ruído , Software
10.
Otol Neurotol ; 38(2): 199-206, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27918363

RESUMO

OBJECTIVE: To describe the incidence, clinical presentation, and performance of cochlear implant (CI) recipients with tip fold-over. STUDY DESIGN: Retrospective case series. SETTING: Tertiary referral center. PATIENTS: CI recipients who underwent postoperative computed tomography (CT) scanning. INTERVENTION(S): Tip fold-over was identified tomographically using previously validated software that identifies the electrode array. Electrophysiologic testing including spread of excitation or electric field imaging (EFI) was measured on those with fold-over. MAIN OUTCOME MEASURE(S): Location of the fold-over; audiological performance pre and postselective deactivation of fold-over electrodes. RESULTS: Three hundred three ears of 235 CI recipients had postoperative CTs available for review. Six (1.98%) had tip fold-over with 5/6 right-sided ears. Tip fold-over occurred predominantly at 270 degrees and was associated with precurved electrodes (5/6). Patients did not report audiological complaints during initial activation. In one patient, the electrode array remained within the scala tympani with preserved residual hearing despite the fold-over. Spread of excitation supported tip fold-over, but the predictive value was not clear. EFI predicted location of the fold-over with clear predictive value in one patient. At an average follow-up of 11 months, three subjects underwent deactivation of the overlapping electrodes with two of them showing marked audiological improvement. CONCLUSION: In a large academic center with experienced surgeons, tip fold-over occurred at a rate of 1.98% but was not immediately identifiable clinically. CT imaging definitively showed tip fold-over. Deactivating involved electrodes may improve performance possibly avoiding revision surgery. EFI may be highly predictive of tip fold-over and can be run intraoperatively, potentially obviating the need for intraop fluoroscopy.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Perda Auditiva/cirurgia , Adolescente , Adulto , Criança , Cóclea/diagnóstico por imagem , Feminino , Audição , Perda Auditiva/diagnóstico por imagem , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
11.
Otol Neurotol ; 37(2): 137-45, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26719955

RESUMO

OBJECTIVE: To test the use of a novel, image-guided cochlear implant (CI) programming (IGCIP) technique on prelingually deafened, adult CI recipients. STUDY DESIGN: Prospective unblinded study. SETTING: Tertiary referral center. PATIENTS: Twenty-six prelingually deafened adult CI recipients with 29 CIs (3 bilateral). INTERVENTION(S): Temporal-bone CT scans were used as input to a series of semiautomated computer algorithms which estimate the location of electrodes in reference to the modiolus. This information was used to selectively deactivate suboptimally located electrodes, i.e., those for which the distance from the electrode to the modiolus was further than a neighboring electrode to the same site. Patients used the new IGCIP program exclusively for 3-5 weeks. MAIN OUTCOME MEASURE(S): Minimum Speech Test Battery (MSTB), quality of life (QOL), and spectral modulation detection (SMD). RESULTS: On average one-third of electrodes were deactivated. At the group level, no significant differences were noted for MSTB measures nor for QOL estimates. Average SMD significantly improved after IGCIP reprogramming, which is consistent with improved spatial selectivity. Using 95% confidence interval data for CNC, AzBio, and BKB-SIN at the individual level, 76 to 90% of subjects demonstrated equivocal or significant improvement. Ultimately 21 of 29 (72.41%) elected to keep the IGCIP map because of perceived benefit often substantiated by improvement on either MSTB, QOL, and/or SMD. CONCLUSIONS: Knowledge of the geometric relationship between CI electrodes and the modiolus appears to be useful in adjusting CI maps in prelingually deafened adults. Long-term improvements may be observed resulting from improved spatial selectivity and spectral resolution.


Assuntos
Mapeamento Encefálico/métodos , Implantes Cocleares , Surdez/cirurgia , Audição , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Algoritmos , Implante Coclear , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Testes de Discriminação da Fala , Percepção da Fala/fisiologia
12.
J Am Acad Audiol ; 26(1): 51-8; quiz 109-10, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25597460

RESUMO

BACKGROUND: Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To date, however, the effect of microphone location on speech recognition in noise has focused primarily on hearing aid users. PURPOSE: The purpose of this study was to (1) measure physical output for the T-Mic as compared with the integrated behind-the-ear (BTE) processor mic for various source azimuths, and (2) to investigate the effect of CI processor mic location for speech recognition in semi-diffuse noise with speech originating from various source azimuths as encountered in everyday communicative environments. RESEARCH DESIGN: A repeated-measures, within-participant design was used to compare performance across listening conditions. STUDY SAMPLE: A total of 11 adults with Advanced Bionics CIs were recruited for this study. DATA COLLECTION AND ANALYSIS: Physical acoustic output was measured on a Knowles Experimental Mannequin for Acoustic Research (KEMAR) for the T-Mic and BTE mic, with broadband noise presented at 0 and 90° (directed toward the implant processor). In addition to physical acoustic measurements, we also assessed recognition of sentences constructed by researchers at Texas Instruments, the Massachusetts Institute of Technology, and the Stanford Research Institute (TIMIT sentences) at 60 dBA for speech source azimuths of 0, 90, and 270°. Sentences were presented in a semi-diffuse restaurant noise originating from the R-SPACE 8-loudspeaker array. Signal-to-noise ratio was determined individually to achieve approximately 50% correct in the unilateral implanted listening condition with speech at 0°. Performance was compared across the T-Mic, 50/50, and the integrated BTE processor mic. RESULTS: The integrated BTE mic provided approximately 5 dB attenuation from 1500-4500 Hz for signals presented at 0° as compared with 90° (directed toward the processor). The T-Mic output was essentially equivalent for sources originating from 0 and 90°. Mic location also significantly affected sentence recognition as a function of source azimuth, with the T-Mic yielding the highest performance for speech originating from 0°. CONCLUSIONS: These results have clinical implications for (1) future implant processor design with respect to mic location, (2) mic settings for implant recipients, and (3) execution of advanced speech testing in the clinic.


Assuntos
Limiar Auditivo , Implantes Cocleares , Perda Auditiva/cirurgia , Ruído , Localização de Som/fisiologia , Percepção da Fala/fisiologia , Pré-Escolar , Feminino , Perda Auditiva/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Processamento de Sinais Assistido por Computador , Teste do Limiar de Recepção da Fala
13.
Otol Neurotol ; 36(1): 43-50, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25275867

RESUMO

OBJECTIVE: To test the hypothesis that children who are non-traditional cochlear implant candidates, but are not making progress with appropriately fitted hearing aids and intervention, will demonstrate significant benefit from cochlear implantation as defined by improvement in (1) speech perception, (2) auditory skills development, and/or (3) progress on standardized measures of receptive and expressive language. STUDY DESIGN: Retrospective case series. SETTING: Two tertiary academic cochlear implant centers. PATIENTS: All pediatric patients that underwent cochlear implantation were reviewed. Only those meeting one or both of the following criteria were included: (1) less severe hearing loss than specified in the current indications and (2) open-set word and/or sentence recognition scores greater than 30% for children who are able to participate in speech perception testing. Patients with auditory neuropathy were excluded. INTERVENTION(S): Cochlear implantation. MAIN OUTCOME MEASURES: Pre- and postoperative results of age appropriate speech recognition tests, auditory questionnaires, and standardized norm-referenced estimates of speech and language development. RESULTS: A total of 51 patients met study criteria. The mean age at time of surgery was 8.3 years and 24% underwent bilateral sequential implantation. Overall, the mean speech recognition improvement was 63 percentage points in the implanted ear (p < 0.001) and 40 percentage points in the bimodal condition (p < 0.001). Results of auditory and language development measures revealed significant improvement after implantation (p < 0.05). CONCLUSION: Non-traditional pediatric implant recipients derive significant benefit from cochlear implantation. A large-scale reassessment of pediatric cochlear implant candidacy, including less severe hearing losses and higher preoperative speech recognition, is warranted to allow more children access to the benefits of cochlear implantation.


Assuntos
Implante Coclear , Perda Auditiva Neurossensorial/cirurgia , Seleção de Pacientes , Adolescente , Criança , Pré-Escolar , Implante Coclear/métodos , Implantes Cocleares , Feminino , Humanos , Lactente , Desenvolvimento da Linguagem , Masculino , Estudos Retrospectivos , Percepção da Fala
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA