RESUMO
To compare the clinical efficacy of ultrasound cycloplasty (UCP) and endoscopic cyclophotocoagulation (ECP) in the treatment of secondary glaucoma. In a 12-month prospective single-center study, 22 patients with secondary glaucoma were treated by high-intensity focused ultrasound (HIFU), and 23 patients with secondary glaucoma were treated by a semiconductor laser. At the final follow-up, the two groups' surgical outcomes were compared. A complete success was defined as an intraocular pressure (IOP) reduction of at least 20% from baseline and an IOP of > 5 mmHg and ⦠21 mmHg, while a qualified success was defined as an IOP reduction of at least 20% from baseline and an IOP of > 5 mmHg. The secondary outcome was the average IOP, number of drugs, and complications at each follow-up compared with the baseline. The average preoperative IOPs in the UCP and ECP groups were 36.4 ± 9.5 mmHg (n = 2.3 drops, n = 0.2 tablets) and 34.5 ± 11.7 mmHg (n = 2.0 drops, n = 0.3 tablets), respectively. In the last follow-up, the success rate of UCP was 54% (with a decrease of 32%) and that of ECP was 65% (with a decrease of 35%), and the P-value between the two groups was > 0.05. However, there was a difference in the average IOP between these two groups 1 day and 1 week after the operation, and the IOP reduction efficiency in the ECP group was better. However, the amount of drug used after these two surgeries was significantly reduced. There were fewer postoperative complications in the UCP group (18 cases) than in the ECP group (35 cases). Both UCP and ECP can effectively reduce IOP in secondary glaucoma, and ECP has a better effect at the early stages. However, UCP has higher safety and tolerance for patients.