Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Nat Commun ; 15(1): 5756, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982087

RESUMO

The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.


Assuntos
Músculo Esquelético , Torque , Ultrassonografia , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Fenômenos Biomecânicos , Adulto , Músculo Esquelético/fisiologia , Músculo Esquelético/diagnóstico por imagem , Adulto Jovem , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Cotovelo/fisiologia , Articulação do Cotovelo/diagnóstico por imagem , Feminino , Movimento/fisiologia , Articulações/fisiologia , Articulações/diagnóstico por imagem , Contração Muscular/fisiologia
2.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941269

RESUMO

Stroke is a leading cause of gait disability that leads to a loss of independence and overall quality of life. The field of clinical biomechanics aims to study how best to provide rehabilitation given an individual's impairments. However, there remains a disconnect between assessment tools used in biomechanical analysis and in clinics. In particular, 3-dimensional ground reaction forces (3D GRFs) are used to quantify key gait characteristics, but require lab-based equipment, such as force plates. Recent efforts have shown that wearable sensors, such as pressure insoles, can estimate GRFs in real-world environments. However, there is limited understanding of how these methods perform in people post-stroke, where gait is highly heterogeneous. Here, we evaluate three subject-specific machine learning approaches to estimate 3D GRFs with pressure insoles in people post-stroke across varying speeds. We find that a Convolutional Neural Network-based approach achieves the lowest estimation errors of 0.75 ± 0.24, 1.13 ± 0.54, and 4.79 ± 3.04 % bodyweight for the medio-lateral, antero-posterior, and vertical GRF components, respectively. Estimated force components were additionally strongly correlated with the ground truth measurements ( ). Finally, we show high estimation accuracy for three clinically relevant point metrics on the paretic limb. These results suggest the potential for an individualized machine learning approach to translate to real-world clinical applications.


Assuntos
Qualidade de Vida , Acidente Vascular Cerebral , Humanos , , Marcha , Fenômenos Mecânicos , Fenômenos Biomecânicos , Caminhada
3.
Science ; 381(6654): 141-146, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37440630

RESUMO

Artificial intelligence (AI) applications in medical robots are bringing a new era to medicine. Advanced medical robots can perform diagnostic and surgical procedures, aid rehabilitation, and provide symbiotic prosthetics to replace limbs. The technology used in these devices, including computer vision, medical image analysis, haptics, navigation, precise manipulation, and machine learning (ML) , could allow autonomous robots to carry out diagnostic imaging, remote surgery, surgical subtasks, or even entire surgical procedures. Moreover, AI in rehabilitation devices and advanced prosthetics can provide individualized support, as well as improved functionality and mobility (see the figure). The combination of extraordinary advances in robotics, medicine, materials science, and computing could bring safer, more efficient, and more widely available patient care in the future. -Gemma K. Alderton.

4.
J Neuroeng Rehabil ; 20(1): 85, 2023 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-37391851

RESUMO

BACKGROUND: Individualized, targeted, and intense training is the hallmark of successful gait rehabilitation in people post-stroke. Specifically, increasing use of the impaired ankle to increase propulsion during the stance phase of gait has been linked to higher walking speeds and symmetry. Conventional progressive resistance training is one method used for individualized and intense rehabilitation, but often fails to target paretic ankle plantarflexion during walking. Wearable assistive robots have successfully assisted ankle-specific mechanisms to increase paretic propulsion in people post-stroke, suggesting their potential to provide targeted resistance to increase propulsion, but this application remains underexamined in this population. This work investigates the effects of targeted stance-phase plantarflexion resistance training with a soft ankle exosuit on propulsion mechanics in people post-stroke. METHODS: We conducted this study in nine individuals with chronic stroke and tested the effects of three resistive force magnitudes on peak paretic propulsion, ankle torque, and ankle power while participants walked on a treadmill at their comfortable walking speeds. For each force magnitude, participants walked for 1 min while the exosuit was inactive, 2 min with active resistance, and 1 min with the exosuit inactive, in sequence. We evaluated changes in gait biomechanics during the active resistance and post-resistance sections relative to the initial inactive section. RESULTS: Walking with active resistance increased paretic propulsion by more than the minimal detectable change of 0.8 %body weight at all tested force magnitudes, with an average increase of 1.29 ± 0.37 %body weight at the highest force magnitude. This improvement corresponded to changes of 0.13 ± 0.03 N m kg- 1 in peak biological ankle torque and 0.26 ± 0.04 W kg- 1 in peak biological ankle power. Upon removal of resistance, propulsion changes persisted for 30 seconds with an improvement of 1.49 ± 0.58 %body weight after the highest resistance level and without compensatory involvement of the unresisted joints or limb. CONCLUSIONS: Targeted exosuit-applied functional resistance of paretic ankle plantarflexors can elicit the latent propulsion reserve in people post-stroke. After-effects observed in propulsion highlight the potential for learning and restoration of propulsion mechanics. Thus, this exosuit-based resistive approach may offer new opportunities for individualized and progressive gait rehabilitation.


Assuntos
Articulação do Tornozelo , Tornozelo , Humanos , Extremidades , Marcha , Peso Corporal
5.
Nat Biomed Eng ; 7(4): 456-472, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36550303

RESUMO

Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.


Assuntos
Exoesqueleto Energizado , Humanos , Marcha , Locomoção
6.
J R Soc Interface ; 19(196): 20220402, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36321374

RESUMO

A quantitative analysis of human gait patterns in space-time provides an opportunity to observe variability within and across individuals of varying motor capabilities. Impaired gait significantly affects independence and quality of life, and thus a large part of clinical research is dedicated to improving gait through rehabilitative therapies. Evaluation of these paradigms relies on understanding the characteristic differences in the kinematics and underlying biomechanics of impaired and unimpaired locomotion, which has motivated quantitative measurement and analysis of the gait cycle. Previous analysis has largely been limited to a statistical comparison of manually selected pointwise metrics identified through expert knowledge. Here, we use a recent statistical-geometric framework, elastic functional data analysis (FDA), to decompose kinematic data into continuous 'amplitude' (spatial) and 'phase' (temporal) components, which can then be integrated with established dimensionality reduction techniques. We demonstrate the utility of elastic FDA through two unsupervised applications to post-stroke gait datasets. First, we distinguish between unimpaired, paretic and non-paretic gait presentations. Then, we use FDA to reveal robust, interpretable groups of differential response to exosuit assistance. The proposed methods aim to benefit clinical practice for post-stroke gait rehabilitation, and more broadly, to automate the quantitative analysis of motion.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Qualidade de Vida , Marcha/fisiologia , Reabilitação do Acidente Vascular Cerebral/métodos , Fenômenos Biomecânicos , Caminhada/fisiologia
7.
Sci Robot ; 7(71): eabq1514, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36260697

RESUMO

Exosuits have the potential to assist locomotion in both healthy and pathological populations, but the effect of exosuit assistance on the underlying muscle-tendon tissue loading is not yet understood. In this study, we used shear wave tensiometers to characterize the modulation of Achilles tendon force with load carriage and exosuit assistance at the ankle. When walking (1.25 m/s) unassisted on a treadmill with load carriage weights of 15 and 30% of body weight, peak Achilles tendon force increased by 11 and 23%, respectively. Ankle exosuit assistance significantly reduced peak Achilles tendon force relative to unassisted, although the magnitude of change was variable across participants. Peak Achilles tendon force was significantly correlated with peak ankle torque for unassisted walking across load carriage conditions. However, when ankle plantarflexor assistance was applied, the relationship between peak tendon force and peak biological ankle torque was no longer significant. An outdoor pilot study was conducted in which a wearable shear wave tensiometer was used to measure Achilles tendon wave speed and compare across an array of assistance loading profiles. Reductions in tendon loading varied depending on the profile, highlighting the importance of in vivo measurements of muscle and tendon forces when studying and optimizing exoskeletons and exosuits.


Assuntos
Tendão do Calcâneo , Humanos , Tendão do Calcâneo/fisiologia , Fenômenos Biomecânicos , Projetos Piloto , Caminhada/fisiologia , Articulação do Tornozelo/fisiologia
8.
J Neuroeng Rehabil ; 18(1): 182, 2021 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-34961521

RESUMO

BACKGROUND: Ankle-targeting resistance training for improving plantarflexion function during walking increases rehabilitation intensity, an important factor for motor recovery after stroke. However, understanding of the effects of resisting plantarflexion during stance on joint kinetics and muscle activity-key outcomes in evaluating its potential value in rehabilitation-remains limited. This initial study uses a unilateral exosuit that resists plantarflexion during mid-late stance in unimpaired individuals to test the hypotheses that when plantarflexion is resisted, individuals would (1) increase plantarflexor ankle torque and muscle activity locally at the resisted ipsilateral ankle, but (2) at higher forces, exhibit a generalized response that also uses the unresisted joints and limb. Further, we expected (3) short-term retention into gait immediately after removal of resistance. METHODS: Ten healthy young adults walked at 1.25 m s-1 for four 10-min discrete bouts, each comprising baseline, exposure to active exosuit-applied resistance, and post-active sections. In each bout, a different force magnitude was applied based on individual baseline ankle torques. The peak resistance torque applied by the exosuit was 0.13 ± 0.01, 0.19 ± 0.01, 0.26 ± 0.02, and 0.32 ± 0.02 N m kg-1, in the LOW, MED, HIGH, and MAX bouts, respectively. RESULTS: (1) Across all bouts, participants increased peak ipsilateral biological ankle torque by 0.13-0.25 N m kg-1 (p < 0.001) during exosuit-applied resistance compared to corresponding baselines. Additionally, ipsilateral soleus activity during stance increased by 5.4-11.3% (p < 0.05) in all but the LOW bout. (2) In the HIGH and MAX bouts, vertical ground reaction force decreased on the ipsilateral limb while increasing on the contralateral limb (p < 0.01). Secondary analysis found that the force magnitude that maximized increases in biological ankle torque without significant changes in limb loading varied by subject. (3) Finally, peak ipsilateral plantarflexion angle increased significantly during post-exposure in the intermediate HIGH resistance bout (p < 0.05), which corresponded to the greatest average increase in soleus activity (p > 0.10). CONCLUSIONS: Targeted resistance of ankle plantarflexion during stance by an exosuit consistently increased local ipsilateral plantarflexor effort during active resistance, but force magnitude will be an important parameter to tune for minimizing the involvement of the unresisted joints and limb during training.


Assuntos
Articulação do Tornozelo , Tornozelo , Articulação do Tornozelo/fisiologia , Fenômenos Biomecânicos , Marcha/fisiologia , Humanos , Caminhada/fisiologia , Adulto Jovem
9.
Acta Neurobiol Exp (Wars) ; 77(1): 57-67, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28379216

RESUMO

Evidences suggest that the presence of chronic kidney disease (CKD) is associated with cerebrovascular diseases related cognitive decline in dialysis patients. As mitochondrial dysfunction is implicated in neurodegenerative disorders, we hypothesized that changes in brain mitochondria occur due to vascular calcification induced by renal failure and the opening of the mitochondrial potassium channel using nicorandil may prevent its dysfunction. Brain tissues from rats with vascular calcification were studied. Nicorandil (7.5 mg/kg b.wt.) was given either concomitantly or after the induction of calcification. The brain tissues were evaluated for antioxidant capacity, mitochondrial enzymes and oxidative phosphorylation efficiency along with the progression of calcification. The results suggested that renal failure, elevated the calcium, phosphorus product in the brain. The brain cytoplasm and mitochondrial fractions showed an elevated TBARS and a corresponding decline in the antioxidant enzymes, indicating a sev ere oxidative stress. The elevated brain mitochondrial enzymes like NADH dehydrogenase, and succinate dehydrogenase in the disease control groups, reversed to the near control level after nicorandil treatment. We observed that nicorandil was more effective when given after calcification. It reduced the biochemical alterations associated with calcium and phosphorous toxicity in the brain, by preserving mitochondria, the key target for treating neurodegenerative diseases.


Assuntos
Mitocôndrias/efeitos dos fármacos , Doenças Mitocondriais/tratamento farmacológico , Nicorandil/uso terapêutico , Estresse Oxidativo/efeitos dos fármacos , Calcificação Vascular/prevenção & controle , Complexo Vitamínico B/uso terapêutico , Animais , Aorta/patologia , Cálcio/metabolismo , Catalase/metabolismo , Esquema de Medicação , Sequestradores de Radicais Livres/metabolismo , Antígenos de Histocompatibilidade Classe I/metabolismo , Testes de Função Renal , Peroxidação de Lipídeos/efeitos dos fármacos , Mitocôndrias/metabolismo , Mitocôndrias/ultraestrutura , Doenças Mitocondriais/etiologia , Nicorandil/farmacologia , Fósforo/metabolismo , Ratos , Ratos Wistar , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Substâncias Reativas com Ácido Tiobarbitúrico/metabolismo , Calcificação Vascular/etiologia , Complexo Vitamínico B/farmacologia
10.
J Biol Rhythms ; 32(2): 165-176, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28367676

RESUMO

Within the human population, there is large interindividual variability in the timing of sleep and circadian rhythms. This variability has been attributed to individual differences in sleep physiology, circadian physiology, and/or light exposure. Recent experimental evidence suggests that the latter is necessary to evoke large interindividual differences in sleep and circadian timing. We used a validated model of human sleep and circadian physiology to test the hypothesis that intrinsic differences in sleep and circadian timing are amplified by self-selected use of artificial light sources. We tested the model under 2 conditions motivated by an experimental study (Wright et al., 2013): (1) a "natural" light cycle, and (2) a "realistic" light cycle that included attenuation of light due to living indoors when natural light levels are high and use of electric light when natural light levels are low. Within these conditions, we determined the relationship between intrinsic circadian period (within the range of 23.7-24.6 h) and timing of sleep onset, sleep offset, and circadian rhythms. In addition, we simulated a work week, with fixed wake time for 5 days and free sleep times on weekends. Under both conditions, a longer intrinsic period resulted in later sleep and circadian timing. Compared to the natural condition, the realistic condition evoked more than double the variation in sleep timing across the physiological range of intrinsic circadian periods. Model predictions closely matched data from the experimental study. We found that if the intrinsic circadian period was long (>24.2 h) under the realistic condition, there was significant mismatch in sleep timing between weekdays and weekends, which is known as social jetlag. These findings indicate that individual tendencies to have very delayed schedules can be greatly amplified by self-selected modifications to the natural light/dark cycle. This has important implications for therapeutic treatment of advanced or delayed sleep phase disorders.


Assuntos
Ritmo Circadiano , Individualidade , Iluminação , Sono , Relógios Biológicos , Temperatura Corporal , Humanos , Síndrome do Jet Lag/etiologia , Modelos Teóricos , Fotoperíodo , Vigília
11.
IEEE Trans Neural Syst Rehabil Eng ; 24(10): 1089-1099, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26929056

RESUMO

The MIT-Skywalker is a novel robotic device developed for the rehabilitation or habilitation of gait and balance after a neurological injury. It represents an embodiment of the concept exhibited by passive walkers for rehabilitation training. Its novelty extends beyond the passive walker quintessence to the unparalleled versatility among lower extremity devices. For example, it affords the potential to implement a novel training approach built upon our working model of movement primitives based on submovements, oscillations, and mechanical impedances. This translates into three distinct training modes: discrete, rhythmic, and balance. The system offers freedom of motion that forces self-directed movement for each of the three modes. This paper will present the technical details of the robotic system as well as a feasibility study done with one adult with stroke and two adults with cerebral palsy. Results of the one-month feasibility study demonstrated that the device is safe and suggested the potential advantages of the three modular training modes that can be added or subtracted to tailor therapy to a particular patient's need. Each participant demonstrated improvement in common clinical and kinematic measurements that must be confirmed in larger randomized control clinical trials.


Assuntos
Biorretroalimentação Psicológica/instrumentação , Paralisia Cerebral/reabilitação , Teste de Esforço/instrumentação , Transtornos Neurológicos da Marcha/reabilitação , Robótica/instrumentação , Reabilitação do Acidente Vascular Cerebral/instrumentação , Acidentes por Quedas/prevenção & controle , Paralisia Cerebral/complicações , Desenho de Equipamento , Análise de Falha de Equipamento , Transtornos Neurológicos da Marcha/etiologia , Humanos , Sistemas Homem-Máquina , Terapia Assistida por Computador/instrumentação , Resultado do Tratamento , Andadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA