Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ned Tijdschr Geneeskd ; 157(33): A6445, 2013.
Artigo em Holandês | MEDLINE | ID: mdl-23945435

RESUMO

Thrombocytopenia during pregnancy can be caused by a broad variety of disorders. An early diagnosis is essential for timely and adequate therapy. In cases of severe thrombocytopenia, a multidisciplinary approach by a team of obstetricians, haematologists and anaesthesiologists is needed. We describe a 30-year-old patient at a gestational age of 35 weeks who presented with preterm rupture of membranes. Coincidentally, she also had severe thrombocytopenia that proved to be due to immune thrombocytopenia (ITP). The severe thrombocytopenia persisted despite standard first-line treatment with corticosteroids and intravenous immunoglobulins. Based on this case report we discuss the differential diagnosis of thrombocytopenia during pregnancy with a focus on the management of ITP in pregnant women.


Assuntos
Complicações Hematológicas na Gravidez/diagnóstico , Trombocitopenia/diagnóstico , Corticosteroides/uso terapêutico , Adulto , Feminino , Ruptura Prematura de Membranas Fetais/etiologia , Ruptura Prematura de Membranas Fetais/prevenção & controle , Humanos , Imunoglobulinas/uso terapêutico , Trabalho de Parto Prematuro/etiologia , Contagem de Plaquetas , Gravidez , Complicações Hematológicas na Gravidez/epidemiologia , Complicações Hematológicas na Gravidez/terapia , Resultado da Gravidez , Cuidado Pré-Natal , Trombocitopenia/epidemiologia , Trombocitopenia/terapia
2.
Biophys Chem ; 60(3): 63-77, 1996 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-8679927

RESUMO

Evidence is presented that a compartmentalised protein exists in its native state only within a particular size of aqueous cavity. This behaviour is shown to exist in AOT reverse micelles using fluorescence quenching and circular dichroism (CD) studies of human serum albumin (HSA). In particular, far ultraviolet CD measurements show that a reduction in quencher accessibility to the fluorophore is consistent with the protein being nearest to its native conformation at a waterpool size of around 80 A diameter. We also show that the biexponential fluorescence decay of N-acetyl-L-tryptophanamide (NATA) in AOT reverse micelles arises from the probe being located in two distinct sites within the interfacial region. The more viscous of these two sites is located on the waterpool side of the interface and the other is located on the oil side of the interface.


Assuntos
Micelas , Albumina Sérica/química , Triptofano/análogos & derivados , Fenômenos Químicos , Físico-Química , Dicroísmo Circular , Polarização de Fluorescência , Humanos , Fotoquímica , Espectrometria de Fluorescência , Triptofano/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA