Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur Heart J Digit Health ; 5(3): 295-302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38774378

RESUMO

Aims: Cardiac amyloidosis (CA) is common in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Cardiac amyloidosis has poor outcomes, and its assessment in all TAVR patients is costly and challenging. Electrocardiogram (ECG) artificial intelligence (AI) algorithms that screen for CA may be useful to identify at-risk patients. Methods and results: In this retrospective analysis of our institutional National Cardiovascular Disease Registry (NCDR)-TAVR database, patients undergoing TAVR between January 2012 and December 2018 were included. Pre-TAVR CA probability was analysed by an ECG AI predictive model, with >50% risk defined as high probability for CA. Univariable and propensity score covariate adjustment analyses using Cox regression were performed to compare clinical outcomes between patients with high CA probability vs. those with low probability at 1-year follow-up after TAVR. Of 1426 patients who underwent TAVR (mean age 81.0 ± 8.5 years, 57.6% male), 349 (24.4%) had high CA probability on pre-procedure ECG. Only 17 (1.2%) had a clinical diagnosis of CA. After multivariable adjustment, high probability of CA by ECG AI algorithm was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.01-1.96, P = 0.046] and higher rates of major adverse cardiovascular events (transient ischaemic attack (TIA)/stroke, myocardial infarction, and heart failure hospitalizations] (HR 1.36, 95% CI 1.01-1.82, P = 0.041), driven primarily by heart failure hospitalizations (HR 1.58, 95% CI 1.13-2.20, P = 0.008) at 1-year follow-up. There were no significant differences in TIA/stroke or myocardial infarction. Conclusion: Artificial intelligence applied to pre-TAVR ECGs identifies a subgroup at higher risk of clinical events. These targeted patients may benefit from further diagnostic evaluation for CA.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38669204

RESUMO

AIMS: Doppler mean gradient (MG) can underestimate aortic stenosis (AS) severity in patients with atrial fibrillation (AF) compared to patients in sinus rhythm (SR), potentially delaying intervention in AF. This study compared outcomes in patients with AF and SR following transcatheter aortic valve replacement (TAVR) and investigated delay in TAVR based on computed tomography aortic valve calcium score (AVCS). METHODS AND RESULTS: Patients who underwent TAVR from 2013 to 2017 for native valve severe AS were identified from an institutional database. Baseline characteristics and overall survival were compared between those in SR and AF. There were 820 patients (mean age 81 years; 41.6% female) included. AF was present in 356 patients. Patients in AF were older (82.2 vs. 80.5, p = 0.003), had lower MG compared to SR patients (42.0 vs. 44.9, p = 0.002) with similar indexed aortic valve area (0.4 vs. 0.4, p = 0.17). Median AVCS was higher in AF (males: AF 2850.0 vs. SR 2561.0, p = 0.044; females: AF 1942.0 vs. SR 1610.5, p = 0.025). Projected AVCS assuming same age of diagnosis was similar between AF and SR. Median survival post-TAVR was worse in AF compared to SR (3.2 vs 5.4 years, log rank p < 0.001). AF, lower MG, higher RVSP, dialysis, diabetes, and significant TR were associated with higher mortality (p < 0.05 for all). CONCLUSION: Older age and higher AVCS in patients with AF compared to SR suggests that AS was both underestimated and more advanced at TAVR referral.

3.
J Am Heart Assoc ; 13(8): e030895, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38587138

RESUMO

BACKGROUND: Percutaneous heart valve procedures have been increasingly performed over the past decade, yet real-world mortality data on valvular heart disease (VHD) in the United States remain limited. METHODS AND RESULTS: We queried the Centers for Disease Control and Prevention's Wide-Ranging Online Data for Epidemiologic Research database among patients ≥15 years old from 1999 to 2020. VHD and its subtypes were listed as the underlying cause of death. We calculated age-adjusted mortality rate (AAMR) per 100 000 individuals and determined overall trends by estimating the average annual percent change using the Joinpoint regression program. Subgroup analyses were performed based on demographic and geographic factors. In the 22-year study, there were 446 096 VHD deaths, accounting for 0.80% of all-cause mortality (56 014 102 people) and 2.38% of the total cardiovascular mortality (18 759 451 people). Aortic stenosis recorded the highest mortality of VHD-related death in both male (109 529, 61.74%) and female (166 930, 62.13%) populations. The AAMR of VHD has declined from 8.4 (95% CI, 8.2-8.5) to 6.6 (95% CI, 6.5-6.7) per 100 000 population. Similar decreasing AAMR trends were also seen for the VHD subtypes. Men recorded higher AAMR for aortic stenosis and aortic regurgitation, whereas women had higher AAMR for mitral stenosis and mitral regurgitation. Mitral regurgitation had the highest change in average annual percent change in AAMR. CONCLUSIONS: The mortality rate of VHD among the US population has declined over the past 2 decades. This highlights the likely efficacy of increasing surveillance and advancement in the management of VHD, resulting in improved outcomes.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Masculino , Feminino , Estados Unidos/epidemiologia , Adolescente , Doenças das Valvas Cardíacas/epidemiologia
4.
Int J Cardiol Heart Vasc ; 51: 101361, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38379633

RESUMO

Background: Atrial fibrillation (AF) is a known complication following patent foramen ovale (PFO) closure. AI-enabled ECG (AI-ECG) acquired during normal sinus rhythm has been shown to identify individuals with AF by noting high-risk ECG features invisible to the human eye. We sought to characterize the value of AI-ECG in predicting AF development following PFO closure and investigate key clinical and procedural characteristics possibly associated with post-procedural AF. Methods: We performed a retrospective analysis of patients who underwent PFO closure at our hospital from January 2011 to December 2022. We recorded the probability (%) of AF using the Mayo Clinic AI-ECG dashboard from pre- and post-procedure ECGs. The cut-off point of ≥ 11 %, which was found to optimally balance sensitivity and specificity in the original derivation paper (the Youden index) was used to label an AI-ECG "positive" for AF. Pre-procedural transesophageal echocardiography (TEE) and pre- and post-procedure transcranial doppler (TCD) data was also recorded. Results: Out of 93 patients, 49 (53 %) were male, mean age was 55 ± 15 years with mean post-procedure follow up of 29 ± 3 months. Indication for PFO closure in 69 (74 %) patients was for secondary prevention of transient ischemic attack (TIA) and/or stroke. Twenty patients (22 %) developed paroxysmal AF post-procedure, with the majority within the first month post-procedure (15 patients, 75 %). Patients who developed AF were not significantly more likely to have a positive post-procedure AI-ECG than those who did not develop AF (30 % AF vs 27 % no AF, p = 0.8).Based on the PFO-Associated Stroke Causal Likelihood (PASCAL) classification, patients who had PFO closure for secondary prevention of TIA and/or stroke in the "possible" group were significantly more likely to develop AF than patients in "probable" and "unlikely" groups (p = 0.034). AF-developing patients were more likely to have post-procedure implantable loop recorder (ILR) (55 % vs 9.6 %, p < 0.001), and longer duration of ILR monitoring (121 vs 92.5 weeks, p = 0.035). There were no significant differences in TCD and TEE characteristics, device type, or device size between those who developed AF vs those who did not. Conclusions: In this small, retrospective study, AI-ECG did not accurately distinguish patients who developed AF post-PFO closure from those who did not. Although AI-ECG has emerged as a valuable tool for risk prediction of AF, extrapolation of its performance to procedural settings such as PFO closure requires further investigation.

5.
Heart ; 110(4): 299-305, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37643771

RESUMO

OBJECTIVES: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration. METHODS: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration. RESULTS: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001). CONCLUSIONS: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Lipoproteína(a) , Estenose da Valva Aórtica/complicações , Ecocardiografia , Insuficiência da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento
6.
J Cardiovasc Dev Dis ; 10(5)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37233159

RESUMO

BACKGROUND: Post-transcatheter aortic valve replacement (TAVR) patient outcome is an important research topic. To accurately assess post-TAVR mortality, we examined a family of new echo parameters (augmented systolic blood pressure (AugSBP) and arterial mean pressure (AugMAP)) derived from blood pressure and aortic valve gradients. METHODS: Patients in the Mayo Clinic National Cardiovascular Diseases Registry-TAVR database who underwent TAVR between 1 January 2012 and 30 June 2017 were identified to retrieve baseline clinical, echocardiographic and mortality data. AugSBP, AugMAP and valvulo-arterial impedance (Zva) (Zva) were evaluated using Cox regression. Receiver operating characteristic curve analysis and the c-index were used to assess the model performance against the Society of Thoracic Surgeons (STS) risk score. RESULTS: The final cohort contained 974 patients with a mean age of 81.4 ± 8.3 years old, and 56.6% were male. The mean STS risk score was 8.2 ± 5.2. The median follow-up duration was 354 days, and the one-year all-cause mortality rate was 14.2%. Both univariate and multivariate Cox regression showed that AugSBP and AugMAP parameters were independent predictors for intermediate-term post-TAVR mortality (all p < 0.0001). AugMAP1 < 102.5 mmHg was associated with a 3-fold-increased risk of all-cause mortality 1-year post-TAVR (hazard ratio 3.0, 95%confidence interval 2.0-4.5, p < 0.0001). A univariate model of AugMAP1 surpassed the STS score model in predicting intermediate-term post-TAVR mortality (area under the curve: 0.700 vs. 0.587, p = 0.005; c-index: 0.681 vs. 0.585, p = 0.001). CONCLUSIONS: Augmented mean arterial pressure provides clinicians with a simple but effective approach to quickly identify patients at risk and potentially improve post-TAVR prognosis.

7.
Pharmacogenomics J ; 22(5-6): 303-307, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35449399

RESUMO

Loss-of-function CYP2C19 variants are associated with increased cumulative ischemic outcomes warranting CYP2C19 genotyping prior to clopidogrel administration. TAILOR-PCI was an international, multicenter (40 sites), prospective, randomized trial comparing rapid point of care (POC) genotype-guided vs. conventional anti-platelet therapy. The performance of buccal-based rapid CYP2C19 genotyping performed by non-laboratory-trained staff in TAILOR-PCI was assessed. Pre-trial training and evaluation involved rapid genotyping of 373 oral samples, with 99.5% (371/373) concordance with Sanger sequencing. During TAILOR-PCI, 5302 patients undergoing PCI were randomized to POC rapid CYP2C19 *2, *3, and *17 genotyping versus no genotyping. At 12 months post-PCI, TaqMan genotyping determined 99.1% (2,364/2,385) concordance with the POC results, with 90.7-98.8% sensitivity and 99.2-99.6% specificity. In conclusion, non-laboratory personnel can be successfully trained for on-site instrument operation and POC rapid genotyping with analytical accuracy and precision across multiple international centers, thereby supporting POC genotyping in patient-care settings, such as the cardiac catheterization laboratory.Clinical Trial Registration: https://www.clinicalTrials.gov (Identifier: NCT01742117).


Assuntos
Intervenção Coronária Percutânea , Humanos , Citocromo P-450 CYP2C19/genética , Inibidores da Agregação Plaquetária/uso terapêutico , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Genótipo , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
8.
J Cardiovasc Dev Dis ; 10(1)2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36661896

RESUMO

BACKGROUND: Prior studies have reported conflicting results of persistent iatrogenic atrial septal defect (iASD) and its impact following a transcatheter edge-to-edge repair (TEER) procedure. This study aims to evaluate the incidence of iASD and its clinical and hemodynamic impact after a TEER. METHODS: Consecutive patients who underwent a TEER procedure from June 2014 to September 2020 at the Mayo Clinic were identified. The presence of iASD was retrospectively identified on post-procedure transthoracic echocardiography (TTE) to group patients into an iASD+ group and an iASD- group for comparison of prognosis and cardiac function. RESULTS: A total of 316 patients were included; the mean age was 79.1 ± 9.1 years, and 67.7% were male. Persistent iASD was diagnosed in 108 (34.2%) patients. There was no difference concerning all-cause mortality, heart failure hospitalization, and stroke/TIA between groups at follow-up (median follow-up of 9 months). Post-procedure TTE demonstrated no differences regarding right ventricle (RV) and left ventricle (LV) dimensions and function, including TAPSE (15.2 ± 4.6 vs. 15.4 ± 5.5 mm, p = 0.875), and LV ejection fraction (51.1 ± 14.0% vs. 51.3 ± 13.9%, p = 0.933). However, patients with iASD had higher RV systolic pressure (48.7 ± 14.4 vs. 45.5 ± 14.5 mmHg, p = 0.042) compared with patients without iASD. CONCLUSION: Notwithstanding higher RV pressures, patients with persistent iASD had no hemodynamic compromise and an equal prognosis compared with those without a residual atrial defect after a TEER procedure. These findings support the mid-term safety of procedures in which an interatrial defect needs to be created and would argue against the need for interventional closure.

10.
Neurologist ; 23(5): 175-180, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30169372

RESUMO

BACKGROUND: The clinical benefit of patent foramen ovale (PFO) closure in patients with cryptogenic stroke (CS) for recurrent stroke prevention has been a subject of extensive debate. Prior clinical trials failed to show superiority of PFO closure versus medical therapy. Meta-analyses suggested a possible benefit of PFO closure in select patients. OBJECTIVE: The objective of this study was to critically assess current evidence regarding the efficacy of PFO closure compared with medical therapy for recurrent stroke prevention in patients with CS. METHODS: The objective was addressed through the development of a structured critically appraised topic. This included a clinical scenario with a clinical question, literature search strategy, critical appraisal, results, evidence summary, commentary, and bottom line conclusions. Participants included consultant and resident neurologists, medical librarian, and vascular neurology and interventional cardiology content experts. RESULTS: A randomized, controlled trial was selected for critical appraisal. This trial compared the efficacy of PFO closure and medical therapy in recurrent stroke prevention. A total of 663 patients who had a recent CS attributed to PFO, with a large interatrial shunt or with an associated atrial septal aneurysm were included. No stroke occurred among the 238 patients in the PFO closure group, whereas 14 of the 235 patients in the antiplatelet therapy group had recurrent strokes. CONCLUSIONS: Among patients who had a recent CS attributed to PFO with a large interatrial shunt or with an associated atrial septal aneurysm, the rate of stroke recurrence was lower among those assigned to PFO closure combined with antiplatelet therapy than among those assigned to antiplatelet therapy alone.


Assuntos
Forame Oval Patente/complicações , Forame Oval Patente/terapia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/uso terapêutico , Ecocardiografia , Forame Oval Patente/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Metanálise como Assunto , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
11.
J Ultrasound Med ; 37(1): 217-224, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28741721

RESUMO

OBJECTIVES: Left ventricular (LV) septal hypertrophy in aortic stenosis raises diagnostic and therapeutic questions. However, the etiology and clinical consequences of this finding have not been well studied. The aim of this study was to perform a morphologic evaluation of the LV in aortic stenosis and to investigate the contributing factors and consequences of septal hypertrophy. METHODS: Patients with moderate or severe aortic stenosis were prospectively enrolled. Patients with previous myocardial infarction, wall motion abnormalities, at least moderate valvular regurgitation, known cardiomyopathy, an LV ejection fraction of less than 50%, and age younger than 65 years were excluded. RESULTS: Forty-one patients underwent a final analysis. Septal hypertrophy (LV septal wall thickness ≥15 mm) was confirmed in 21 of 41 patients. The septal hypertrophy group had higher peak aortic valve velocity, a higher diabetes mellitus rate, and a higher rate and longer duration of hypertension than those without septal hypertrophy. The peak aortic valve velocity (odds ratio, 7.1; 95% confidence interval, 1.4-37.1) and diabetes mellitus (odds ratio, 7.4; 95% confidence interval, 1.2-46.2) were the significant factors associated with septal hypertrophy by multivariate analysis. Intraventricular conduction disturbance on electrocardiography was more frequent in the septal hypertrophy group (P = .021). CONCLUSIONS: Left ventricular septal hypertrophy was commonly observed in elderly patients with aortic stenosis, and a higher aortic valve velocity, hypertension, and diabetes mellitus were associated factors. Intraventricular conduction disturbance occurred more often in patients with septal hypertrophy than those without, which implies the pathophysiologic consequence. Further studies are needed to determine the impact of septal hypertrophy and intraventricular conduction disturbance on the prognosis of patients after aortic valve interventions.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Eletrocardiografia/métodos , Avaliação Geriátrica/métodos , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/fisiopatologia , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Estudos Prospectivos
12.
Ann Card Anaesth ; 19(Supplement): S6-S11, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27762242

RESUMO

BACKGROUND: The surgical and procedural specialties are continually evolving their methods to include more complex and technically difficult cases. These cases can be longer and incorporate multiple teams in a different model of operating room synergy. Patients are frequently older, with comorbidities adding to the complexity of these cases. Recording of this environment has become more feasible recently with advancement in video and audio capture systems often used in the simulation realm. AIMS: We began using live capture to record a new procedure shortly after starting these cases in our institution. This has provided continued assessment and evaluation of live procedures. The goal of this was to improve human factors and situational challenges by review and debriefing. SETTING AND DESIGN: B-Line Medical's LiveCapture video system was used to record successive transcatheter aortic valve replacement (TAVR) procedures in our cardiac catheterization/laboratory. An illustrative case is used to discuss analysis and debriefing of the case using this system. RESULTS AND CONCLUSIONS: An illustrative case is presented that resulted in long-term changes to our approach of these cases. The video capture documented rare events during one of our TAVR procedures. Analysis and debriefing led to definitive changes in our practice. While there are hurdles to the use of this technology in every institution, the role for the ongoing use of video capture, analysis, and debriefing may play an important role in the future of patient safety and human factors analysis in the operating environment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Gravação de Videoteipe , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Humanos , Tempo de Internação , Salas Cirúrgicas , Segurança do Paciente , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
Tex Heart Inst J ; 43(2): 171-4, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27127438

RESUMO

Patent foramen ovale is a common clinical finding that generally becomes a concern in the presence of transient ischemic attack or stroke. Rarely, patent foramen ovale is associated with hypoxemia in the presence of substantial right-to-left atrial shunting. We present the case of an 86-year-old woman with a pacemaker, who was initially asymptomatic notwithstanding a patent foramen ovale. Over 1.5 years, her symptoms progressed in a stepwise fashion, in the setting of progressive pacemaker-associated tricuspid regurgitation. Ultimately, the patient's symptoms and her hypoxemia resolved after percutaneous closure of her patent foramen ovale with use of a 25-mm "Cribriform" occluder device. This case highlights the fact that clinically significant right-to-left shunting requires an anatomic lesion, such as patent foramen ovale, together with elevated right atrial pressure, which in this case was contributed by severe tricuspid regurgitation.


Assuntos
Forame Oval Patente/diagnóstico , Átrios do Coração/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/métodos , Progressão da Doença , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Humanos , Dispositivo para Oclusão Septal , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia
14.
Ann Card Anaesth ; 18(2): 246-51, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25849702

RESUMO

Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Risco , Resultado do Tratamento , Ultrassonografia
15.
Heart Views ; 15(4): 124-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25774255

RESUMO

Paradoxical coronary artery embolism is a rare, but often an underdiagnosed cause of acute myocardial infarction. It should be considered in patient who presents with chest pain and otherwise having a low risk profile for atherosclerosis coronary artery disease. We describe a case of paradoxical coronary artery embolism causing ST segment elevation myocardial infarction in a patient with upper extremity venous thrombosis. Echocardiography demonstrated a patent foramen ovale (PFO) with bidirectional shunt. In addition to treatment of acute coronary event closure of the PFO should be considered to prevent a recurrence.

16.
J Vasc Surg ; 55(1): 237-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21820840

RESUMO

Intra-aortic inferior vena cava filter placement is a rare event. We describe a case in which a permanent vena caval filter was retrieved from the aorta with endovascular techniques. Knowledge of filter design, catheters, and available wires is important to perform this procedure safely.


Assuntos
Aorta/cirurgia , Procedimentos Endovasculares , Filtros de Veia Cava/efeitos adversos , Adulto , Anticoagulantes/uso terapêutico , Aortografia/métodos , Remoção de Dispositivo , Humanos , Masculino , Desenho de Prótese , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
J Invasive Cardiol ; 22(8): 377-81, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20679675

RESUMO

The buddy wire is a useful technique for difficult-to-cross lesions that are typically identified by poor guide support, vessel tortuosity, calcification and/or prior stent placement. We present 5 cases of percutaneous coronary interventional success involving difficult-to-cross lesions using the "crooked buddy" technique, a unique combination of the Wiggle guidewire as the rail and an extra support guidewire as the buddy wire. From our experience, we recommend that when difficult-to-cross lesions are identified, moving quickly to the crooked buddy technique may avoid unnecessary equipment, contrast and procedure time.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Angiopatias Diabéticas/complicações , Feminino , Humanos , Hiperlipidemias/complicações , Hipertensão/complicações , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações
19.
J Invasive Cardiol ; 22(2): 76-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20124593

RESUMO

OBJECTIVES: Compare outcomes of hybrid bare-metal stent (BMS)/sirolimus-eluting stent (SES) to BMS alone for the treatment of stenoses in small coronary arteries. BACKGROUND: One approach to potentially reduce the risk of restenosis in long lesions with smaller distal reference diameters is to use a small (2.0-2.5 mm) "BMS cap" (BMC) distally, telescoped in tandem with a SES(s) proximally, matched to a proximal segment where the diameter is > or = 2.5 mm (creating a BMC/SES hybrid stent). Results from previous reports using "hybrid" drug-eluting stents and BMS are mixed. METHODS: We performed a retrospective analysis of BMC/SES cases in small vessels at our institution and compared the outcomes with a control group (BMS) consisting of patients treated with at least one 2.0-2.5 mm BMS. RESULTS: During the years 2003-2006, 41 BMC/SES and 62 BMS cases were identified and follow up was available in 33 and 49 patients, respectively. Baseline demographics, procedure indications and pertinent discharge medications for the two groups were similar. Despite the use of more stents and longer total stent length in the BMC/SES group compared to the BMS group (2.9 +/- 0.79 vs. 1.4 +/- 0.69 and 64 +/- 21 mm vs. 26 +/- 18 mm; p < 0.0001 for both comparisons), there was a significant decrease in the composite of restenosis, myocardial infarction and cardiac death (9% vs. 29%; p = 0.033). CONCLUSIONS: The use of a "BMS cap" distally, telescoped in tandem with SES more proximally, may be a reasonable approach in treating long lesions in coronary arteries with distal reference diameters < or = 2.5 mm.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários , Stents Farmacológicos , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
IEEE Trans Biomed Eng ; 56(2): 513-7, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19272945

RESUMO

The aim of this project is to improve the detection of coronary occlusions using an approach based on the recording and analysis of isolated diastolic heart sounds associated with turbulent blood flow in occluded coronary arteries. The nonlinear dynamic analysis method based on approximate entropy has been proposed for the analysis of diastolic heart sounds. A commercially available electronic stethoscope was used to record the diastolic heart sounds from patients diagnosed with or without coronary artery disease (CAD) based on their coronary angiography examination. The nonlinear dynamical analysis (approximate entropy) measures of the diastolic heart sounds recorded from 30 patients with coronary occlusions and ten normal subjects were estimated. Results suggest the presence of the high nonlinear (approximate entropy) values of diastolic heart sounds associated with CAD (p < 0.05). This approach led to a sensitivity of 77%, a specificity of 80%, and an overall accuracy of 78%. As a summary, 23 out of 30 abnormal patients and eight out of ten normal patients were correctly detected.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Oclusão Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Auscultação Cardíaca/instrumentação , Sopros Cardíacos/fisiopatologia , Erros de Diagnóstico , Eletrônica Médica/instrumentação , Humanos , Dinâmica não Linear , Sensibilidade e Especificidade , Estetoscópios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA