Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38708449

RESUMO

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/anatomia & histologia , Projetos Piloto , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/diagnóstico por imagem , Lágrimas/fisiologia , Ritmo Circadiano/fisiologia , Fatores de Tempo
2.
Ophthalmol Sci ; 3(4): 100334, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37920420

RESUMO

Purpose: To develop and evaluate a deep learning algorithm for Meibomian gland characteristics calculation. Design: Evaluation of diagnostic technology. Subjects: A total of 1616 meibography images of both the upper (697) and lower (919) eyelids from a total of 282 individuals. Methods: Images were collected using the LipiView II device. All the provided data were split into 3 sets: the training, validation, and test sets. Data partitions used proportions of 70/10/20% and included data from 2 optometry settings. Each set was separately partitioned with these proportions, resulting in a balanced distribution of data from both settings. The images were divided based on patient identifiers, such that all images collected for one participant could end up only in one set. The labeled images were used to train a deep learning model, which was subsequently used for Meibomian gland segmentation. The model was then applied to calculate individual Meibomian gland metrics. Interreader agreement and agreement between manual and automated methods for Meibomian gland segmentation were also carried out to assess the accuracy of the automated approach. Main Outcome Measures: Meibomian gland metrics, including length ratio, area, tortuosity, intensity, and width, were measured. Additionally, the performance of the automated algorithms was evaluated using the aggregated Jaccard index. Results: The proposed semantic segmentation-based approach achieved average aggregated Jaccard index of mean 0.4718 (95% confidence interval [CI], 0.4680-0.4771) for the 'gland' class and a mean of 0.8470 (95% CI, 0.8432-0.8508) for the 'eyelid' class. The result for object detection-based approach was a mean of 0.4476 (95% CI, 0.4426-0.4533). Both artificial intelligence-based algorithms underestimated area, length ratio, tortuosity, widthmean, widthmedian, width10th, and width90th. Meibomian gland intensity was overestimated by both algorithms compared with the manual approach. The object detection-based algorithm seems to be as reliable as the manual approach only for Meibomian gland width10th calculation. Conclusions: The proposed approach can successfully segment Meibomian glands; however, to overcome problems with gland overlap and lack of image sharpness, the proposed method requires further development. The study presents another approach to utilizing automated, artificial intelligence-based methods in Meibomian gland health assessment that may assist clinicians in the diagnosis, treatment, and management of Meibomian gland dysfunction. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

3.
Clin Exp Optom ; : 1-11, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37989323

RESUMO

CLINICAL RELEVANCE: Evaluating how Meibomian glands can change in appearance has the potential to advance the understanding of Meibomian gland health and may lead to enhanced diagnosis and therapy. BACKGROUND: This work aimed to investigate Meibomian gland appearance after therapeutic Meibomian gland expression. METHODS: Fifteen subjects attended three study visits over a two-week period. Meibography was performed before and after therapeutic Meibomian gland expression, the following day, and 2 weeks after expression. Six central glands were used to calculate Meibomian gland morphological parameters such as gland length ratio, gland width, gland area, gland tortuosity, and gland contrast. A custom semi-automated image analysis software was used to calculate Meibomian gland metrics. Furthermore, a high-resolution imaging system was developed to capture clear images of the Meibomian glands, free of any artefacts, which were used for precise calculations of Meibomian gland contrast. RESULTS: The expression procedure had a significant impact on Meibomian gland contrast and length ratio immediately afterwards. The least square mean difference (95% CI) from baseline for Michelson contrast was -0.006 (-0.010, -0.001) and -1.048 (-2.063, -0.033) for simple contrast. The least square mean ratio of the gland length ratio immediately after the expression to baseline was 0.758 (0.618, 0.931). CONCLUSIONS: Following therapeutic expression, Meibomian glands exhibit reduced brightness and length. However, within 24 h, they appear to recover and return to their baseline state, indicating a relatively short recovery time. This sheds light on whether meibography is solely focused on capturing gland structure or if it also captures acinar activity. The hyperreflective properties of lipids suggest that the decrease in contrast observed after expression could be attributed to a reduction in the visualisation of acini activity. A decrease in Meibomian gland length ratio implies that the loss of gland structure following treatment may be indicative of a temporary structural alteration.

4.
Transl Vis Sci Technol ; 12(2): 9, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36749580

RESUMO

Purpose: To develop and evaluate a custom imaging system to provide high-resolution, wide depth-of-field, reflection-free, multispectral infrared (IR) imaging of the Meibomian glands. Methods: Lower eyelids of 15 volunteers were everted to obtain multispectral images of the Meibomian glands with custom imaging setup. Photographs were captured at 10 different ISO settings (from underexposure to overexposure) and using nine IR imaging filters (ranging from 600 nm to 1000 nm in 50-nm steps). Meibomian gland contrast (simple and Michelson) was calculated for the images to choose an optimal wavelength for Meibomian gland imaging and to determine differences in contrast across individuals. Results: The overall linear regression model showed a significant effect of wavelength on Meibomian gland contrast (Simple contrast: F = 7.24, P < 0.0001; Michelson contrast: F = 7.19, P < 0.0001). There was a significant negative correlation between Meibomian gland contrast and Meibomian gland depth for 750-nm IR filter (ρs= -0.579; P = 0.026). Conclusions: Meibomian gland contrast varies across individuals and depends on Meibomian gland depth. IR filter of 750 nm is the optimal choice for Meibomian gland imaging because it provides images of greatest contrast. Translational Relevance: This study adds to our understanding of Meibomian gland imaging. It has successfully demonstrated that Meibomian glands that are deeper in the tarsal plate require longer wavelengths for imaging.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem
5.
Ocul Surf ; 25: 119-128, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35724917

RESUMO

Meibography is a visualisation technique that has been used for over 40 years. There have been significant improvements in image quality, examination technique and image interpretation over this period. Although meibography has received sporadic reviews in the past, an updated review is timely due to the rapid recent rise of relevant technology and advances in both image processing and artificial intelligence. The primary aim of this paper is to review recent research into Meibomian gland imaging and update the community about the most relevant technologies and approaches used in the field.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Inteligência Artificial , Síndromes do Olho Seco/diagnóstico , Doenças Palpebrais/diagnóstico , Humanos , Processamento de Imagem Assistida por Computador , Glândulas Tarsais/diagnóstico por imagem , Lágrimas
6.
Cont Lens Anterior Eye ; 44(2): 192-219, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33775377

RESUMO

This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.


Assuntos
Conjuntivite , Lentes de Contato Hidrofílicas , Piscadela , Túnica Conjuntiva , Córnea , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA