Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Water Res ; 254: 121388, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38430759

RESUMO

The periodate (PI)-based advanced oxidation process is valued for environmental remediation, but current activation methods involve high costs, secondary contamination risks, and limited applicability due to external energy inputs (e.g., UV), catalyst incorporation (e.g., Fe2+), or environmental modifications (e.g., freezing). In this work, novel bioelectric activation of PI using the electrons generated by electroactive bacteria was developed and investigated for rapid removal of carbamazepine (CBZ), achieving 100 %, 100 %, and 76 % removal efficiency for 4.22 µM of CBZ in 20 min at pH 2, 120 min at pH 6.4, and HRT of 30 min at pH 8.5, respectively, with a 1 mM PI dose and without an input voltage. It was deduced that electrons derived from bacteria could directly activate PI using Ti mesh electrodes and generate •IO3 via single electron transfer under strongly acidic conditions (e.g., pH 2). Nevertheless, under weak alkaline conditions (e.g., pH 8.5), biogenic electrons indirectly activated PI by generating OH-via 4e-reduction at the Ti mesh cathode, resulting in the formation of •O2- and 1O2. In addition to the metal cathode, a carbon-based cathode finely modulates the 2e-reduction, yielding H2O2 and activating PI to mainly form •OH. Moreover, primarily non-toxic IO3- was produced during treatment, while no detectable reactive iodine species (HOI, I2, and I3-) were observed. Furthermore, the bioelectric activation of PI demonstrated its capability to remove various micropollutants present in secondary-treated municipal wastewater, showcasing its broad-spectrum degradation ability. This study introduces a novel, cost-effective, and environmentally friendly PI activation technique with promising applicability for micropollutant elimination in water treatment.


Assuntos
Peróxido de Hidrogênio , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Águas Residuárias , Ácido Periódico , Oxirredução , Carbamazepina
2.
Polymers (Basel) ; 11(11)2019 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-31703261

RESUMO

Microfabricated devices have been introduced as a promising approach to overcome some of the challenges related to oral administration of drugs and, thereby, improve their oral bioavailability. In this study, we fabricate biodegradable microcontainers with different polymers, namely poly-ɛ-caprolactone (PCL), poly(lactic-co-glycolic acid) (PLGA) 50:50 and PLGA 75:25 by hot punching. The mucoadhesion of the microcontainers is assessed with an ex vivo retention model on porcine intestinal tissue. Finally, in vitro degradation studies of the biodegradable microcontainers are completed for six weeks in simulated intestinal medium with the addition of pancreatic enzymes. Through SEM inspection, the PLGA 50:50 microcontainers show the first signs of degradation already after two weeks and complete degradation within four weeks, while the other polymers slowly degrade in the medium over several weeks.

3.
Int J Pharm ; 570: 118658, 2019 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-31491485

RESUMO

Micro fabricated delivery systems have shown promise in increasing oral bioavailability of drugs. Micrometer-sized polymeric devices (microcontainers) have the potential to facilitate unidirectional drug release directly into the intestinal mucosa whereby, drug absorption can be enhanced. The aim of this study was to develop an ex vivo model to investigate mucosal adhesion and orientation of microcontainers. Furthermore, to investigate how microcontainers with varying height, shape and material behave in regards to mucoadhesion and orientation. Microcontainers were placed at the top of an inclined piece of porcine small intestine. The tissue was perfused with biorelevant medium followed by microscopic examination to observe the orientation and amount of microcontainers on the tissue. The mucoadhesion of the microcontainers were evaluated based on the observed position on the tissue after being exposed to flow. When comparing the varying types of microcontainers, good adhesion was in general observed since most of the microcontainers were located in the beginning of the intestine. Microcontainers fabricated from the epoxy-based photoresist SU-8 had a slightly better adherence than those fabricated from poly-ɛ-caprolactone (PCL). The orientation of the microcontainers appeare to be dictated mainly by the height. In general, the model showed promising results in evaluating mucoadhesion and orientation.


Assuntos
Mucosa Intestinal/metabolismo , Preparações Farmacêuticas/química , Preparações Farmacêuticas/metabolismo , Administração Oral , Animais , Disponibilidade Biológica , Caproatos/química , Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos/efeitos dos fármacos , Lactonas/química , Polímeros/química , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA