Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 48(5): 550-558, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38409825

RESUMO

BACKGROUND: In conventional left ventricular assist devices (LVAD), a separate outflow graft is sutured to the ascending aorta. Novel device designs may include a transventricular outflow cannula crossing the aortic valve (AV). While transversal ventricular dimensions are well investigated in patients with severe heart failure, little is known about the longitudinal dimensions. These dimensions are, however, particularly critical for the design and development of mechanical circulatory support (MCS) devices with transaortic outflow cannula. METHODS: In an explorative retrospective cohort study at the University Medical Center Freiburg, Germany, the longitudinal cardiac dimensions of patients undergoing computed tomography angiography (CTA) before and, if available, after LVAD implantation were analyzed. Among others, the following dimensions were assessed: (a) apex to AV, (b) apex to mitral valve, (c) AV to sinotubular junction (STJ), (d) apex to STJ, (e) apex to brachiocephalic artery (BCA), and (f) AV to BCA. RESULTS: In total, 44 LVAD patients (36 male, age 55.8 years, height 1.75 m) were included. The longitudinal cardiac dimensions were (a) 114.5 ± 12.1 mm, (b) 108.0 ± 12.4 mm, (c) 20.9 ± 2.9, (d) 135.4 ± 13.4 mm, (e) 206.0 ± 18.3, and (f) 91.5 ± 9.8 mm. Postoperatively, (a) and (b) decreased by 31.5% and 39.5%, respectively (N = 14). CONCLUSIONS: Longitudinal cardiac dimensions may be reduced by up to 40% after LVAD implantation. A better knowledge of these dimensions and their postoperative alterations in LVAD patients may improve surgical planning and help to design MCS devices with transventricular outflow cannula.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Aorta Torácica/cirurgia , Aorta , Valva Aórtica , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
2.
Sci Rep ; 14(1): 1869, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253776

RESUMO

Pigs are frequently applied as animal models in cardiovascular research due to their anatomical and physiological similarity to humans. For study planning and refinement, precise knowledge of the cardioaortic dimensions is essential. In a retrospective single-center study, the cardioaortic dimensions and left ventricular function of German Landrace pigs were assessed using cardiac MRI. All parameters were compared between male and female pigs and analyzed for correlation with body weight. In total, 15 pigs were included (7 male and 8 female, weight 60.9 ± 7.0 kg). The left ventricle revealed an end-diastolic diameter of 50.5 ± 4.4 mm and an ejection fraction of 51.2 ± 9.8%. The diameters of the ascending and descending aorta were 21.3 ± 2.3 and 16.2 ± 1.4 mm, respectively. There were no significant differences between male and female pigs, except that males had a smaller end-diastolic left ventricular volume (p = 0.041). A moderate correlation was found between body weight and the aortic annulus diameter (R = 0.57, p = 0.027). In conclusion, cardiac MRI allows precise quantification of porcine cardioaortic dimensions. For medical device testing, size differences between pigs and humans should be considered.


Assuntos
Coração , Imageamento por Ressonância Magnética , Humanos , Feminino , Masculino , Suínos , Animais , Estudos Retrospectivos , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Peso Corporal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA