Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
Children (Basel) ; 8(9)2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34572258

RESUMO

The transcatheter closure of patent ductus arteriosus (TCPC) has been demonstrated to be feasible even in infants weighing ≤1000 g. However, other percutaneous cardiac interventions (PCI) for such small infants born with congenital heart defects (CHD) or acquired heart defects (AHD) have not been well described. The purpose of this study was to describe the feasibility and safety of PCI in infants ≤1000 g. A retrospective review was conducted between June 2015 and May 2021, looking at 148 consecutive PCIs performed on infants weighing ≤1000 g at the time of the procedure. The procedural success rate was 100%. The major adverse event (AE) rate for TCPC was 3%, while there were no major AEs for other PCI. It is feasible to perform PCIs in infants weighing ≤1000 g with CHD and AHD using currently available technologies.

3.
J Am Soc Echocardiogr ; 34(10): 1086-1094, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34139301

RESUMO

BACKGROUND: Transthoracic echocardiography (TTE) is increasingly utilized for guiding transcatheter closure of patent ductus arteriosus (PDA) in extremely low birth weight (ELBW) infants. The objectives of this study were to compare PDA size measurements by TTE with angiographic measurements and to describe TTE techniques used in guiding transcatheter PDA closure (TCPC) in ELBW infants. METHODS: One hundred twenty-five consecutive ELBW infants (gestational age < 27 weeks, birth weight < 1 kg) who underwent TCPC before 8 weeks of age under TTE guidance were included. Patent ductus arteriosus sizes were measured from the procedural TTE and angiograms retrospectively by blinded observers. The TTE PDA diameters at the aortic (ED1) and pulmonary end (ED2) were compared with the corresponding angiographic diameters (CD1 and CD2). The TTE PDA lengths, obtained by two techniques (EL1, a straight line between ED1 and ED2; and EL2, a curvilinear line along the PDA), were compared with the PDA length by angiography (CL). Transthoracic echocardiography was used to guide accurate device positioning within the PDA. RESULTS: The procedure weight was 600-1,460 g. The TTE and angiographic PDA diameters were comparable (mean ED1 vs CD1 = 4.5 ± 0.68 vs 4.4 ± 0.85 mm, P = .26; and mean ED2 vs CD2 = 3.1 ± 0.72 vs 3.2 ± 0.94 mm, P = .14). The angiographic length was underestimated by EL1 by 2.6 ± 1.6 mm (P < .0001), while EL2 estimated it better (mean EL2 vs CL = 11.0 ± 1.83 vs 10.8 ± 2.15 mm; P = .40). Transcatheter PDA closure was successful in 100% of the cases using TTE guidance. There were no intraprocedural complications. CONCLUSIONS: Transthoracic echocardiography guidance during TCPC in ELBW infants eliminates the need for aortograms via femoral arterial access, preventing the complications associated with it. Transthoracic echocardiography PDA measurements are comparable to angiographic measurements, thereby assisting in appropriate device size selection.


Assuntos
Permeabilidade do Canal Arterial , Angiografia , Cateterismo Cardíaco , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia , Humanos , Lactente , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Recém-Nascido , Estudos Retrospectivos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(1): 117-127, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33942962

RESUMO

OBJECTIVES: This study sought to obtain in vivo data on a new stent and delivery system specifically designed for implantation in infants with the ability to be enlarged to adult dimensions. BACKGROUND: There are no endovascular stents designed for or approved for use in infants, nor is there a stent capable of being implanted at infant vessel diameters and achieving adult size while maintaining structural integrity. The Minima stent was designed to address these needs. METHODS: This study was performed in 6 piglets who underwent implantation of 22 Minima stents into the following locations: aorta (n = 11), branch pulmonary arteries (n = 6), and central veins (n = 5). RESULTS: Successful deployment occurred in 21/22 attempts. Two instances of post-deployment migration occurred. Stents were re-expanded at 1, 2, 3 and 5 months after implant. All stents regardless of location could be re-dilated to the intended diameter to keep pace with somatic growth (implant diameter 6.9 +/- 1.2 mm; final diameter 16.1 mm +/- 1.4 mm). Histopathology at 1 and 5 months demonstrated widely patent vessel lumens with stent apposition to vessel wall, early mild inflammatory response surrounding stent struts, typical vascular damage and healing response to acute dilation and a progressive smooth neointimal growth covering stent struts over time. CONCLUSIONS: In this in vivo study of the Minima stent, there was high implant success, predictable re-dilatability to adult diameters and favorable histopathology. Further study is warranted.


Assuntos
Artéria Pulmonar , Stents , Adulto , Animais , Aorta , Humanos , Lactente , Neointima , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Suínos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA