Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Sleep Biol Rhythms ; 21(1): 85-95, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38468906

RESUMO

Automatic algorithms are a proposed alternative to manual assessment of polysomnography data for analyzing sleep structure; however, none are acceptably accurate for clinical use. We investigated the feasibility of an automated sleep stage scoring system called Sleep Scope, which is intended for use with portable 1-channel electroencephalograph, and compared it with the traditional polysomnography scoring method. Twenty-six outpatients and fourteen healthy volunteers underwent Sleep Scope and polysomnography assessments simultaneously. Polysomnography records were manually scored by three sleep experts. Sleep Scope records were scored using a dedicated auto-staging algorithm. Sleep parameters, including total sleep time, sleep latency, wake after sleep onset, and sleep efficiency, were calculated. The epoch-by-epoch pairwise concordance based on the classification of sleep into five stages (i.e., wake, rapid eye movement, N1, N2, and N3) was also evaluated after validating homogeneity and bias between Sleep Scope and polysomnography. Compared with polysomnography, Sleep Scope seemed to overestimate sleep latency by approximately 3 min, but there was no consistent tendency in bias in other sleep parameters. The Κ values ranged from 0.66 to 0.75 for experts' inter-rater polysomnography scores and from 0.62 to 0.67 for Sleep Scope versus polysomnography scores, which indicated sufficient agreement in the determination of sleep stages based on the Landis and Koch criteria. We observed sufficient concordance between Sleep Scope and polysomnography despite lower concordance in sleep disorder patients. Thus, this auto-staging system might serve as a novel clinical tool for reducing the time and expenses required of medical staff and patients. Supplementary Information: The online version contains supplementary material available at 10.1007/s41105-022-00421-5.

3.
NPJ Genom Med ; 7(1): 29, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35414074

RESUMO

Idiopathic hypersomnia (IH) is a rare, heterogeneous sleep disorder characterized by excessive daytime sleepiness. In contrast to narcolepsy type 1, which is a well-defined type of central disorders of hypersomnolence, the etiology of IH is poorly understood. No susceptibility loci associated with IH have been clearly identified, despite the tendency for familial aggregation of IH. We performed a variation screening of the prepro-orexin/hypocretin and orexin receptors genes and an association study for IH in a Japanese population, with replication (598 patients and 9826 controls). We identified a rare missense variant (g.42184347T>C; p.Lys68Arg; rs537376938) in the cleavage site of prepro-orexin that was associated with IH (minor allele frequency of 1.67% in cases versus 0.32% in controls, P = 2.7 × 10-8, odds ratio = 5.36). Two forms of orexin (orexin-A and -B) are generated from cleavage of one precursor peptide, prepro-orexin. The difference in cleavage efficiency between wild-type (Gly-Lys-Arg; GKR) and mutant (Gly-Arg-Arg; GRR) peptides was examined by assays using proprotein convertase subtilisin/kexin (PCSK) type 1 and PCSK type 2. In both PCSK1 and PCSK2 assays, the cleavage efficiency of the mutant peptide was lower than that of the wild-type peptide. We also confirmed that the prepro-orexin peptides themselves transmitted less signaling through orexin receptors than mature orexin-A and orexin-B peptides. These results indicate that a subgroup of IH is associated with decreased orexin signaling, which is believed to be a hallmark of narcolepsy type 1.

4.
Sleep Biol Rhythms ; 20(1): 137-148, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38469065

RESUMO

Idiopathic hypersomnia (IH) is a rare sleep disorder characterized by excessive daytime sleepiness, great difficulty upon awakening, and prolonged sleep time. In contrast to narcolepsy type 1, which is a well-recognized hypersomnia, the etiology of IH remains poorly understood. No susceptibility loci for IH have been identified, although familial aggregations have been observed among patients with IH. Narcolepsy type 1 is strongly associated with human leukocyte antigen (HLA)-DQB1*06:02; however, no significant associations between IH and HLA alleles have been reported. To identify genetic variants that affect susceptibility to IH, we performed a genome-wide association study (GWAS) and two replication studies involving a total of 414 Japanese patients with IH and 6587 healthy Japanese individuals. A meta-analysis of the three studies found no single-nucleotide polymorphisms (SNPs) that reached the genome-wide significance level. However, we identified several candidate SNPs for IH. For instance, a common genetic variant (rs2250870) within an intron of PDE9A was suggestively associated with IH. rs2250870 was significantly associated with expression levels of PDE9A in not only whole blood but also brain tissues. The leading SNP in the PDE9A region was the same in associations with both IH and PDE9A expression. PDE9A is a potential target in the treatment of several brain diseases, such as depression, schizophrenia, and Alzheimer's disease. It will be necessary to examine whether PDE9A inhibitors that have demonstrated effects on neurophysiologic and cognitive function can contribute to the development of new treatments for IH, as higher expression levels of PDE9A were observed with regard to the risk allele of rs2250870. The present study constitutes the first GWAS of genetic variants associated with IH. A larger replication study will be required to confirm these associations. Supplementary Information: The online version contains supplementary material available at 10.1007/s41105-021-00349-2.

5.
J Hum Genet ; 63(12): 1259-1267, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30266950

RESUMO

Essential hypersomnia (EHS) is a lifelong disorder characterized by excessive daytime sleepiness without cataplexy. EHS is associated with human leukocyte antigen (HLA)-DQB1*06:02, similar to narcolepsy with cataplexy (narcolepsy). Previous studies suggest that DQB1*06:02-positive and -negative EHS are different in terms of their clinical features and follow different pathological pathways. DQB1*06:02-positive EHS and narcolepsy share the same susceptibility genes. In the present study, we report a genome-wide association study with replication for DQB1*06:02-negative EHS (408 patients and 2247 healthy controls, all Japanese). One single-nucleotide polymorphism, rs10988217, which is located 15-kb upstream of carnitine O-acetyltransferase (CRAT), was significantly associated with DQB1*06:02-negative EHS (P = 7.5 × 10-9, odds ratio = 2.63). The risk allele of the disease-associated SNP was correlated with higher expression levels of CRAT in various tissues and cell types, including brain tissue. In addition, the risk allele was associated with levels of succinylcarnitine (P = 1.4 × 10-18) in human blood. The leading SNP in this region was the same in associations with both DQB1*06:02-negative EHS and succinylcarnitine levels. The results suggest that DQB1*06:02-negative EHS may be associated with an underlying dysfunction in energy metabolic pathways.


Assuntos
Carnitina O-Acetiltransferase/genética , Cromossomos Humanos Par 9/genética , Distúrbios do Sono por Sonolência Excessiva/genética , Cadeias beta de HLA-DQ/genética , Polimorfismo de Nucleotídeo Único , Distúrbios do Sono por Sonolência Excessiva/enzimologia , Feminino , Estudo de Associação Genômica Ampla , Humanos , Masculino
6.
Hum Genome Var ; 2: 15031, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27081540

RESUMO

Narcolepsy without cataplexy (NA w/o CA) (narcolepsy type 2) is a lifelong disorder characterized by excessive daytime sleepiness and rapid eye movement (REM) sleep abnormalities, but no cataplexy. In the present study, we examined the human leukocyte antigen HLA-DQB1 in 160 Japanese patients with NA w/o CA and 1,418 control subjects. Frequencies of DQB1*06:02 were significantly higher in patients with NA w/o CA compared with controls (allele frequency: 16.6 vs. 7.8%, P=1.1×10(-7), odds ratio (OR)=2.36; carrier frequency: 31.3 vs. 14.7%, P=7.6×10(-8), OR=2.64). Distributions of HLA-DQB1 alleles other than DQB1*06:02 were compared between NA w/o CA and narcolepsy with cataplexy (NA-CA) to assess whether the genetic backgrounds of the two diseases have similarities. The distribution of the HLA-DQB1 alleles in DQB1*06:02-negative NA w/o CA was significantly different from that in NA-CA (P=5.8×10(-7)). On the other hand, the patterns of the HLA-DQB1 alleles were similar between DQB1*06:02-positive NA w/o CA and NA-CA. HLA-DQB1 analysis was also performed in 186 Japanese patients with idiopathic hypersomnia (IHS) with/without long sleep time, but no significant associations were observed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA