1.
Ann Nucl Med ; 30(6): 435-44, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27154308

RESUMO

OBJECTIVE: The optimization of medical exposure is one of the major issues regarding radiation protection in the world, and The International Committee of Radiological Protection and the International Atomic Energy Agency recommend establishing diagnostic reference levels (DRLs) as tools for dose optimization. Therefore, the development of DRLs based on the latest survey has been required for nuclear medicine-related societies and organizations. This prompted us to conduct a nationwide survey on the actual administered radioactivity to adults for the purpose of developing DRLs in nuclear medicine. METHODS: A nationwide survey was conducted from November 25, 2014 to January 16, 2015. The questionnaire was sent to all of the 1249 nuclear medicine facilities in Japan, and the responses were collected on a website using an answered form. RESULTS: Responses were obtained from 516 facilities, for a response rate of 41 %. 75th percentile of (99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy, (99m)Tc-HM-PAO, (99m)Tc-ECD and (123)I-IMP: cerebral blood flow scintigraphy, (99m)Tc-Tetrofosmin, (99m)Tc-MIBI and (201)Tl-Cl; myocardial perfusion scintigraphy and (18)F-FDG: oncology PET (in-house-produced or delivery) in representative diagnostic nuclear medicine scans were 932, 937, 763, 775, 200, 831, 818, 180, 235 and 252, respectively. More than 90 % of the facilities were within the range of 50 % from the median of these survey results in representative diagnostic nuclear medicine facilities in Japan. Responses of the administered radioactivities recommended by the package insert, texts and guidelines such as 740 MBq ((99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy), 740 MBq ((99m)Tc-ECD and (99m)Tc-HM-PAO: cerebral blood flow scintigraphy) and 740 MBq ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI: myocardial perfusion scintigraphy), etc. were numerous. The administered activity of many radiopharmaceuticals of bone scintigraphy ((99m)Tc-MDP and (99m)Tc-HMDP), cerebral blood flow scintigraphy ((99m)Tc-HM-PAO) and myocardial perfusion scintigraphy ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI), etc. were within the range of the EU DRLs and almost none of the administered radioactivity in Japan exceeded the upper limit of SNMMI standard administered radioactivity. CONCLUSIONS: This survey indicated that the administered radioactivity in diagnostic nuclear medicine in Japan had been in the convergence zone and nuclear medicine facilities in Japan show a strong tendency to adhere to the texts and guidelines. Furthermore, the administered radioactivities in Japan were within the range of variation of the EU and the SNMMI administered radioactivities.


Assuntos
Diagnóstico por Imagem/normas , Compostos Radiofarmacêuticos/química , Inquéritos e Questionários , Adulto , Humanos , Japão , Radioatividade , Compostos Radiofarmacêuticos/administração & dosagem , Padrões de Referência , Sociedades Médicas
2.
Artigo em Japonês | MEDLINE | ID: mdl-22277821

RESUMO

Changing into slippers when entering the nuclear medicine management district prevented pollution expansion. Accidents involving patients falling occurred in university facilities. It was thought that changing slippers was the cause. The pollution situation was measured in three facilities by using the smear method and the direct technique to examine the effect of changing slippers. The current state was measured. After pollution prevention guidance was continuously done, pollution expansion was measured; three weeks of measurements were compared. Pollution was detected in the first period of weeks at a frequency of 19 times. For the latter period, it was detected 6 times. Half the pollution was in the restroom. Pollution was reduced by doing pollution prevention guidance for the restroom. Patients' falls occur even if they change slippers. Falling accidents can be decreased.


Assuntos
Acidentes por Quedas/prevenção & controle , Poluição Ambiental/prevenção & controle , Instalações de Saúde , Serviço Hospitalar de Medicina Nuclear , Poluentes Radioativos , Sapatos , Acidentes por Quedas/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Poluição Ambiental/análise , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Poluentes Radioativos/análise , Radiometria/métodos , Sapatos/efeitos adversos , Adulto Jovem
3.
Artigo em Japonês | MEDLINE | ID: mdl-22026982

RESUMO

(123)I-MIBG Heart-to-Mediastinum activity ratio (H/M) is commonly used as an indicator of relative myocardial (123)I-MIBG uptake. H/M ratios reflect myocardial sympathetic nerve function, therefore it is a useful parameter to assess regional myocardial sympathetic denervation in various cardiac diseases. However, H/M ratio values differ by site, gamma camera system, position and size of region of interest (ROI), and collimator. In addition to these factors, 529 keV scatter component may also affect (123)I-MIBG H/M ratio. In this study, we examined whether the H/M ratio shows correlation between two different gamma camera systems and that sought for H/M ratio calculation formula. Moreover, we assessed the feasibility of (123)I Dual Window (IDW) method, which is a scatter correction method, and compared H/M ratios with and without IDW method. H/M ratio displayed a good correlation between two gamma camera systems. Additionally, we were able to create a new H/M calculation formula. These results indicated that the IDW method is a useful scatter correction method for calculating (123)I-MIBG H/M ratios.


Assuntos
3-Iodobenzilguanidina , Calibragem , Câmaras gama , Coração/diagnóstico por imagem , Radioisótopos do Iodo , Mediastino/diagnóstico por imagem , Cintilografia/métodos , Compostos Radiofarmacêuticos , Espalhamento de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Coração/inervação , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Cintilografia/instrumentação , Sistema Nervoso Simpático/fisiopatologia , Adulto Jovem
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 65(6): 755-64, 2009 Jun 20.
Artigo em Japonês | MEDLINE | ID: mdl-19602800

RESUMO

Angiographic cone-beam CT, called DynaCT by SIEMENS, is a 3D imaging tool reconstructed from projection data by a rotational C-arm with a flat panel detector. It can visualize low-contrast objects such as soft tissue or small vessels as well as high-contrast structures such as enhanced vessels or bone. We need to understand its image characteristics and dose distribution during 200 degree rotation around a patient. In this research, we evaluated fundamental characteristics and dose effectiveness for optimized clinical images. DynaCT, including soft tissue information and isochronal voxel data along the z-axis, could provide enough CT-like image quality for IVR use. In addition, evaluation of accumulated dose distribution helped us to predict and avoid the occurrence of radiodermatitis. Thus, DynaCT is useful as a support and navigation tool for IVR.


Assuntos
Angiografia , Tomografia Computadorizada de Feixe Cônico , Angiografia/instrumentação , Angiografia/métodos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Radiografia Intervencionista/instrumentação , Radiografia Intervencionista/métodos , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA