Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Kyobu Geka ; 76(5): 388-391, 2023 May.
Artigo em Japonês | MEDLINE | ID: mdl-37150920

RESUMO

A 45-year-old man complaining of chest and back pain due to acute aortic dissection was referred to our department. A contrast enhanced computed tomography( CT) scan showed Stanford type B aortic dissection with Kommerell diverticulum and aberrant right subclavian artery. The patient underwent antihypertensive treatment for one month. Despite the successful treatment, CT scan revealed a 5 mm false lumen dilatation in this period. We decided to close the primary entry. The operation was performed through median sternotomy;after establishing cardio-pulmonary bypass, the ostium of the aberrant right subclavian artery( ARSA) was sutured closed and anastomosed the ARSA and right common carotid artery. Total arch replacement was performed using frozen elephant trunk technique. His postoperative course was uneventful.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Anormalidades Cardiovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Anormalidades Cardiovasculares/complicações , Anormalidades Cardiovasculares/diagnóstico por imagem , Anormalidades Cardiovasculares/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos
2.
J Vasc Surg Cases Innov Tech ; 8(4): 625-628, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36248389

RESUMO

Neurofibromatosis type 1 is associated with vascular fragility, and vascular disease is the second leading cause of death in these patients. A 42-year-old woman with neurofibromatosis type 1 was transferred to our hospital owing to shock. A computed tomography scan revealed a ruptured celiac artery aneurysm, which had expanded from 14 to 26 mm in 1 day. The survival rate of patients with celiac artery rupture is extremely low, and there is no consensus on treatment. Here, we successfully performed a hybrid procedure with emergent implantation of aortic stent grafts for life-saving treatment and subsequent laparotomy for complete hemostasis.

3.
Vasc Endovascular Surg ; : 15385744221095921, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-35532352

RESUMO

PURPOSE: To describe the efficiency of the candy-plug technique using an Excluder aortic extender and obtain optimal aortic remodeling. CASE: A 46-year-old male patient had a history of acute type B aortic dissection and progressive dilation of the descending aorta (53 mm diameter) with a patent false lumen. He was treated with the candy-plug technique, using an Excluder aortic extender of 32-45 mm was placed and a 16-mm Amplatzer Vascular Plug II. No technical complications were observed in the patient. Good aortic remodeling was observed after 6 months, CT showed complete thrombosis of the false lumen and reduction of the maximum perpendicular diameter of the descending aorta from 53 to 47 mm. The diameter of the other proximal zones of the descending aorta was 45-47 mm, and the Excluder aortic extender changed into an elliptical shape. This is the first report of good aortic remodeling with an elliptical shape by performing the candy-plug technique. DISCUSSION: The candy-plug technique using an Excluder aortic extender is an improved method for occluding the false lumen as it provides improved aortic remodeling. The 2 indications for this surgery are limited. A large entry point in the descending abdominal aorta that is more peripheral than the candy-plug position must be visible on contrast-enhanced CT and the false lumen is not too large. We consider candy-plug placement in the true lumen central to the TEVAR to avoid occluding the artery of Adamkiewicz, since we have to avoid the thrombosis of the peripheral false lumen where a candy-plug was placed. Since it is unclear whether long-term results are satisfactory, we must continue to study chronic aortic type B dissection.

5.
Opt Express ; 15(13): 7974-83, 2007 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-19547125

RESUMO

High transmission of slow-light in a photonic crystal (PC) waveguide (WG) using a hetero group-velocity (Ht-V(g)) PC-WG was proposed and experimentally investigated. The Ht-V(g) WG, which comprises a low-group-velocity (L-V(g)) PC-WG section between two identical high-group- velocity (H-V(g)) PC-WGs, is designed to decrease the impedance mismatch of the L-V(g) PC-WG. The increase in transmittance of a propagating pulse was confirmed in the Ht-V(g) PC-WG even in the vicinity of the band-gap, whereas the homogeneous PC-WG showed a gradual decrease in transmittance with the pulse wavelength approaching the band-gap. The group index (n(g)) of the L-V(g) region in the Ht-V(g) PC-WG was measured by the cross-correlation method and attained a value above 20. On the other hand, the transmittance of the Ht-V(g) structure recovered approximately 16dB compared to the homogeneous L-V(g) WG having same n(g), 17. This recovery is mainly dominated by the coupling improvement due to the Ht-V(g) structure, around 12dB. These results indicate the effectiveness of the Ht-V(g) structure to use slow light in a PC-WG, which leads to various applications in PC-based optical devices.

6.
Opt Express ; 14(20): 9502-7, 2006 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-19529337

RESUMO

Topology optimization has been used to design intersections in two-dimensional photonic crystal slab waveguides. We have experimentally confirmed that the optimized intersection displays high-transmittance with low-crosstalk for the straightforward beam-propagation line.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA