Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Bioengineering (Basel) ; 11(3)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38534547

RESUMO

Ophthalmological services face global inadequacies, especially in low- and middle-income countries, which are marked by a shortage of practitioners and equipment. This study employed a portable slit lamp microscope with video capabilities and cloud storage for more equitable global diagnostic resource distribution. To enhance accessibility and quality of care, this study targets corneal opacity, which is a global cause of blindness. This study has two purposes. The first is to detect corneal opacity from videos in which the anterior segment of the eye is captured. The other is to develop an AI pipeline to detect corneal opacities. First, we extracted image frames from videos and processed them using a convolutional neural network (CNN) model. Second, we manually annotated the images to extract only the corneal margins, adjusted the contrast with CLAHE, and processed them using the CNN model. Finally, we performed semantic segmentation of the cornea using annotated data. The results showed an accuracy of 0.8 for image frames and 0.96 for corneal margins. Dice and IoU achieved a score of 0.94 for semantic segmentation of the corneal margins. Although corneal opacity detection from video frames seemed challenging in the early stages of this study, manual annotation, corneal extraction, and CLAHE contrast adjustment significantly improved accuracy. The incorporation of manual annotation into the AI pipeline, through semantic segmentation, facilitated high accuracy in detecting corneal opacity.

2.
PLoS One ; 17(3): e0264390, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35275919

RESUMO

Cardiovascular and cerebrovascular diseases are frequently interconnected due to underlying pathology involving atherosclerosis and thromboembolism. The aim of this study was to investigate the impact of clinical interactions among cardiovascular and cerebrovascular diseases on patient outcomes using a large-scale nationwide claims-based dataset. Cardiovascular diseases were defined as myocardial infarction, heart failure, atrial fibrillation, and aortic dissection. Cerebrovascular diseases were defined as cerebral infarction, intracerebral hemorrhage, and subarachnoid hemorrhage. This retrospective study included 2,736,986 inpatient records (1,800,255 patients) at 911 hospitals from 2015 to 2016 from Japanese registry of all cardiac and vascular disease-diagnostic procedure combination dataset. Interactions among comorbidities and complications, rehospitalization, and clinical outcomes including in-hospital mortality were investigated. Among hospitalization records that involved cardiovascular disease, 5.9% (32,686 records) had cerebrovascular disease as a comorbidity and 2.1% (11,362 records) included an incident cerebrovascular complication after hospitalization. Cerebrovascular disease as a comorbidity or complication was associated with higher in-hospital mortality than no cerebrovascular disease (adjusted odds ratio (OR) [95% confidence interval]: 1.10 [1.06-1.14], 2.02 [1.91-2.13], respectively). Among 367,904 hospitalization records that involved cerebrovascular disease, 17.7% (63,647 records) had cardiovascular disease listed as comorbidity and 3.3% (11,834 records) as a complication. Only cardiovascular disease as a complication was associated with higher in-hospital mortality (adjusted OR [95% confidence interval]: 1.29 [1.22-1.37]). In addition, in-hospital mortality during rehospitalization due to the other disease was significantly higher than mortality during the hospitalization due to the first disease. In conclusion, substantial associations were observed between cardiovascular and cerebrovascular disease in a large-scale nationwide claims-based dataset; these associations had a significant impact on clinical outcomes. More intensive prevention and management of cardiovascular and cerebrovascular disease might be crucial.


Assuntos
Fibrilação Atrial , Doenças Cardiovasculares , Infarto do Miocárdio , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/epidemiologia , Hemorragia Cerebral/complicações , Hemorragia Cerebral/epidemiologia , Mortalidade Hospitalar , Hospitalização , Humanos , Estudos Retrospectivos , Fatores de Risco
3.
Surg Endosc ; 36(5): 2869-2878, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34076770

RESUMO

BACKGROUND AND AIMS: Endoscopic biliary drainage (EBD) is essential for the management of malignant hilar biliary obstruction (MHBO). We prospectively evaluated the efficacy and safety of "inside-stent" therapy, where a plastic stent is placed above the sphincter of Oddi without endoscopic sphincterotomy, in patients with inoperable MHBO. METHODS: This study was a multicenter, single-blinded, randomized controlled trial at three centers. Patients with inoperable MHBO were enrolled in this study, and randomly assigned to receive an inside-stent or conventional-stent therapy. The primary endpoint was cumulative stent patency of the initial stent. The secondary endpoints were second stent patency, technical and clinical success rate, adverse events, re-intervention rate, and overall patient survival. RESULTS: Forty-three patients were randomly assigned to the inside-stent group (n = 21) or the conventional-stent group (n = 22). The median cumulative stent patency of the initial stent was 123 days in the inside-stent group and 51 days in the conventional-stent group (P = .031). For patients with the initial stent dysfunction in the conventional-stent group, the inside-stent was placed as a second stent, and its patency was significantly longer than that of the initial stent (P = .0001). The technical and clinical success rate, re-intervention rate, second stent patency, adverse events, and survival probability did not differ between the groups. CONCLUSIONS: Inside-stent therapy appears to be useful not only as an initial stent but also as a second stent for patients with inoperable MHBO. TRIAL REGISTRATION NUMBER: UMIN000004587.


Assuntos
Neoplasias dos Ductos Biliares , Colestase , Esfíncter da Ampola Hepatopancreática , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/cirurgia , Colestase/etiologia , Colestase/cirurgia , Drenagem , Humanos , Estudos Retrospectivos , Esfíncter da Ampola Hepatopancreática/cirurgia , Stents/efeitos adversos , Resultado do Tratamento
4.
Gastrointest Endosc ; 91(2): 373-381.e2, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31654634

RESUMO

BACKGROUND AND AIMS: Histologic diagnosis of autoimmune pancreatitis (AIP) using EUS-guided FNA (EUS-FNA) is difficult. To address this issue, new fine-needle biopsy (FNB) needles were recently developed. Here, we prospectively evaluated 2 newly designed EUS-FNB needles for histologic evaluation in patients with type 1 AIP. METHODS: This was a prospective, randomized, multicenter trial comparing biopsy specimens obtained with a 22-gauge Franseen needle or a 20-gauge forward-bevel needle in patients with suspected type 1 AIP. AIP was diagnosed according to international consensus diagnostic criteria. The primary endpoint was the sensitivity of EUS-FNB needles, and secondary endpoints were the amount of specimen obtained, histology of the pancreas based on evaluation of lymphoplasmacytic sclerosing pancreatitis (LPSP), and contribution of histologic findings to the diagnosis of AIP. RESULTS: One hundred ten patients were randomly assigned to the Franseen group (22-gauge Franseen needle) or the forward-bevel group (20-gauge forward-bevel needle). EUS-FNB sampling was successful in all patients. Nine patients were excluded because of diagnoses other than AIP. Compared with the forward-bevel needle, the Franseen needle obtained a significantly greater number of high-power fields. Of 101 patients, 39 patients (78%) in the Franseen group and 23 patients (45%) in the Forward-bevel group were diagnosed with level 1 or 2 LPSP (P = .001). Thirty-six patients could not be diagnosed with type 1 AIP without EUS-FNB specimen results. CONCLUSIONS: The 22-gauge Franseen needle should be routinely used for histologic diagnosis of type 1 AIP. (Clinical trial registration number: UMIN 000027668.).


Assuntos
Pancreatite Autoimune/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Adulto , Idoso , Idoso de 80 Anos ou mais , Pancreatite Autoimune/diagnóstico , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
J Med Syst ; 44(1): 21, 2019 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-31823092

RESUMO

The amount and complexity of data accumulated in electronic health record (EHR) is quite large, and the quantity of information that clinicians can examine and handle is very limited. Thus, it is necessary to enhance the accessibility of EHR by improving the user experience (UX). To apply information visualization that turns EHR data into an understandable visual format, we propose following five screen design principles when designing UX interfaces. #1: One view should contain single patient data. #2: Data should be summarized or titled for overview and details should be given on-demand. #3: Data should be displayed in time-series. #4: Data should be categorized by primary type. #5: More data should be displayed at the same time. Three screen designs are plausible utilizing the above-mentioned principles. To measure the UX of screen designs and validate the design principles, we built an EHR viewer system that has three windows corresponding to these screen designs and had it tested by medical staff. The results of the test revealed that the UX of the screen design is proportional to the number of design principles that the screen design incorporates. It shows that the proposed screen design principles improve the UX of EHR.


Assuntos
Apresentação de Dados/normas , Registros Eletrônicos de Saúde , Melhoria de Qualidade , Interface Usuário-Computador , Humanos
6.
Stud Health Technol Inform ; 264: 1662-1663, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31438281

RESUMO

The amount of text of electronic medical records and its changes over time are not clear. In designing an electronic medical records system, prediction of the amount of text is important. We analyzed the number of characters described in the electronic medical records. As a result, it became clear that the annual text quantity of electronic medical records follows the lognormal distribution, and also the amount has been increasing year by year.


Assuntos
Registros Eletrônicos de Saúde
7.
Stud Health Technol Inform ; 264: 1966-1967, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31438431

RESUMO

Physical inactivity is a social problem related to health. Based on the concept of health communication, this study aims to construct a mechanism to provide continuous information to improve physical activity. We built a "home digital signage system" which consists of a function of collecting the localized information from the websites and distributing to the tablets. The results of the introduction of this system have been suggested to promote walking by increasing media exposure.


Assuntos
Exercício Físico , Caminhada , Humanos , Atividade Motora
8.
Endoscopy ; 51(9): 852-857, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30759467

RESUMO

BACKGROUND: Selective biliary cannulation (SBC) is the first challenge of endoscopic retrograde cholangiopancreatography (ERCP), especially for trainees, and a rotatable sphincterotome may be useful to guide the directional axis of the scope and SBC. METHODS: We performed a prospective randomized single-center trial, enrolling 200 patients with a native papilla who required therapeutic biliary ERCP. Patients were randomly assigned to the rotatable sphincterotome group (n = 100) or the conventional sphincterotome group (n = 100). The primary endpoint was successful SBC by the trainees within 10 minutes. RESULTS: The early and late cannulation success rates did not differ significantly between the groups (P = 0.46 and P > 0.99, respectively). For the patients in whom trainees failed to achieve SBC, the rotatable sphincterotome was used as a rescue cannulation technique in four patients from the conventional group; in no patients in the rotatable group was the conventional sphincterotome used for SBC. Post-ERCP pancreatitis (PEP) occurred in 11 patients (5.5 %; 6 mild, 5 moderate); the incidence did not differ significantly between the two groups (rotatable group 3 %, conventional group 8 %; P = 0.21). The two groups were thus combined for evaluation of the factors relating to cannulation difficulty for trainees, which revealed that orientation of the papilla was a significant factor (P < 0.001). CONCLUSIONS: The type of sphincterotome used did not affect the success of SBC by trainees. However, orientation of the papilla was revealed to be a significant factor relating to cannulation difficulty for trainees overall.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica/instrumentação , Esfinterotomia Endoscópica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Ductos Biliares , Cateterismo , Competência Clínica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Adulto Jovem
9.
Stud Health Technol Inform ; 225: 858-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27332378

RESUMO

Access logs for electronic medical records (EMRs) are a useful source of data for understanding how nurses' perform their duties. The purpose of this study was to understand how nurses' used an EMR system, by inspecting and analyzing from one week EMR access logs (394,708) of accessing 'outcome Input' screen. Anytime day and night, nurses accessed 'outcome Input' screen. Viewing and information input obtained from observations, in order to monitor patients' conditions over tasks such as keeping nursing records.


Assuntos
Registros Eletrônicos de Saúde/estatística & dados numéricos , Armazenamento e Recuperação da Informação/métodos , Processo de Enfermagem/estatística & dados numéricos , Registros de Enfermagem/estatística & dados numéricos , Recursos Humanos de Enfermagem Hospitalar/estatística & dados numéricos , Padrões de Prática em Enfermagem/estatística & dados numéricos , Japão , Cuidados de Enfermagem/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde
10.
Stud Health Technol Inform ; 216: 198-201, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26262038

RESUMO

A sensor network is key infrastructure for advancing a hospital information system (HIS). The authors proposed a method to provide roaming functionality for Bluetooth to realize a Bluetooth-based sensor network, which is suitable to connect clinical devices. The proposed method makes the average response time of a Bluetooth connection less than one second by making the master device repeat the inquiry process endlessly and modifies parameters of the inquiry process. The authors applied the developed sensor network for daily clinical activities in an university hospital, and confirmed the stabilitya and effectiveness of the sensor network. As Bluetooth becomes a quite common wireless interface for medical devices, the proposed protocol that realizes Bluetooth-based sensor network enables HIS to equip various clinical devices and, consequently, lets information and communication technologies advance clinical services.


Assuntos
Redes de Comunicação de Computadores/instrumentação , Registros Eletrônicos de Saúde/organização & administração , Sistemas de Informação Hospitalar/organização & administração , Armazenamento e Recuperação da Informação/métodos , Sistemas de Identificação de Pacientes , Tecnologia sem Fio/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Japão , Miniaturização , Registros de Enfermagem
11.
Artigo em Inglês | MEDLINE | ID: mdl-26262228

RESUMO

In Japan, most of all the university and advanced hospitals have implemented both electronic order entry systems and electronic charting. In addition, all medical records are subjected to inspector audit for quality assurance. The record of informed consent (IC) is very important as this provides evidence of consent from the patient or patient's family and health care provider. Therefore, we developed an automatic audit system for a hospital information system (HIS) that is able to evaluate IC automatically using machine learning.


Assuntos
Consentimento Livre e Esclarecido , Aprendizado de Máquina , Auditoria Médica/métodos , Registros Eletrônicos de Saúde , Humanos , Sistemas Computadorizados de Registros Médicos
12.
Artigo em Inglês | MEDLINE | ID: mdl-26262246

RESUMO

Hospital administration is very important and many hospitals carry out activity-based costing under comprehensive medicine. However, nursing cost is unclear, because nursing practice is expanding both quantitatively and qualitatively and it is difficult to grasp all nursing practices, and nursing cost is calculated in many cases comprehensively. On the other hand, a nursing information system (NIS) is implemented in many hospitals in Japan and we are beginning to get nursing practical data. In this paper, we propose a nursing cost accounting model and we simulate a cost by nursing contribution using NIS data.


Assuntos
Contabilidade/métodos , Custos Hospitalares/estatística & dados numéricos , Sistemas de Informação Hospitalar/organização & administração , Processo de Enfermagem/estatística & dados numéricos , Economia da Enfermagem/estatística & dados numéricos , Sistemas de Informação Hospitalar/estatística & dados numéricos , Humanos , Japão , Processo de Enfermagem/economia , Recursos Humanos de Enfermagem Hospitalar/economia , Recursos Humanos de Enfermagem Hospitalar/estatística & dados numéricos
13.
Artigo em Inglês | MEDLINE | ID: mdl-26262268

RESUMO

To improve UX of EMR/EHR, the screen design principles for the visualization are required. Through the study of common attributes of medical records, we present four principles and show three screen designs by applying them.


Assuntos
Apresentação de Dados , Registros Eletrônicos de Saúde , Design de Software , Apresentação de Dados/normas , Registros Eletrônicos de Saúde/normas , Humanos
14.
Int J Health Plann Manage ; 29(3): e207-32, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23785010

RESUMO

Comparison of financial indices helps to illustrate differences in operations and efficiency among similar hospitals. Outlier data tend to influence statistical indices, and so detection of outliers is desirable. Development of a methodology for financial outlier detection using information systems will help to reduce the time and effort required, eliminate the subjective elements in detection of outlier data, and improve the efficiency and quality of analysis. The purpose of this research was to develop such a methodology. Financial outliers were defined based on a case model. An outlier-detection method using the distances between cases in multi-dimensional space is proposed. Experiments using three diagnosis groups indicated successful detection of cases for which the profitability and income structure differed from other cases. Therefore, the method proposed here can be used to detect outliers.


Assuntos
Economia Hospitalar , Administração Financeira de Hospitais , Modelos Estatísticos , Discrepância de GDH/economia , Algoritmos , Benchmarking , Humanos
15.
Artigo em Inglês | MEDLINE | ID: mdl-24110770

RESUMO

The aim of this research is to develop an information support system for tele-auscultation. In auscultation, a doctor requires to understand condition of applying a stethoscope, in addition to auscultatory sounds. The proposed system includes intuitive navigation system of stethoscope operation, in addition to conventional audio streaming system of auscultatory sounds and conventional video conferencing system for telecommunication. Mixed reality technology is applied for intuitive navigation of the stethoscope. Information, such as position, contact condition and breath, is overlaid on a view of the patient's chest. The contact condition of the stethoscope is measured by e-textile contact sensors. The breath is measured by a band type breath sensor. In a simulated tele-auscultation experiment, the stethoscope with the contact sensors and the breath sensor were evaluated. The results show that the presentation of the contact condition was not understandable enough for navigating the stethoscope handling. The time series of the breath phases was usable for the remote doctor to understand the breath condition of the patient.


Assuntos
Auscultação/instrumentação , Auscultação/métodos , Sistemas de Informação em Saúde , Testes Respiratórios , Desenho de Equipamento , Humanos , Médicos , Estetoscópios , Telemedicina/métodos , Tórax
16.
Stud Health Technol Inform ; 192: 1031, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23920805

RESUMO

In Japan, medical staff must select a diagnosis procedure combination (DPC) code for each inpatient upon admission. We report on the development and evaluation of a supporting system for DPC code selection. This system, based on a machine learning method developed by Okamoto et al., makes DPC code suggestions that are derived from medical practice information pertaining to inpatients. The use of the suggestions helps medical staff select an appropriate DPC code for each inpatient. We asked health information management professionals to evaluate the system and to compare the suggested DPC codes with those selected by doctors. They reported that the system was generally useful and that using this system they could find some cases of hospitalized patients whose DPC codes needed correction. However, they also determined the precision of the system needs improvement.


Assuntos
Inteligência Artificial , Sistemas de Apoio a Decisões Clínicas/organização & administração , Grupos Diagnósticos Relacionados/classificação , Grupos Diagnósticos Relacionados/organização & administração , Sistemas Computadorizados de Registros Médicos/organização & administração , Admissão do Paciente , Sumários de Alta do Paciente Hospitalar , Japão , Processamento de Linguagem Natural , Qualidade da Assistência à Saúde , Revisão da Utilização de Recursos de Saúde
17.
Stud Health Technol Inform ; 192: 1212, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23920986

RESUMO

This paper designed and prototyped a networked hospital management serious game for education, and evaluated the prototype. A player, the president of each hospital, makes management decisions under various clinical indicators, and the decision affects condition of the other hospitals as well as of his/her own. The interaction makes the players compete, and, at the same time, exchange their findings each other.


Assuntos
Instrução por Computador/métodos , Teoria dos Jogos , Administração Hospitalar/educação , Design de Software , Software , Interface Usuário-Computador , Jogos de Vídeo , Modelos Organizacionais
18.
Stud Health Technol Inform ; 184: 242-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23400164

RESUMO

Virtual reality (VR) simulation is expected to be advantageous to surgical training for invasive operations such as incision and dissection that are unrepeatable in the real world. This study focuses on ablation in order to provide a simulation model for soft tissue rupture progression. To simulate soft tissue handling by two or more manipulators, the model must calculate the stress accumulation at the tip of a rupture. This stress accumulation is affected by the stress condition caused by the manipulators. Herein, the authors propose a method to integrate multiple stresses with two different hypotheses. The proposed model was evaluated through the simulation of primitive board ablation.


Assuntos
Tecido Conjuntivo/fisiologia , Tecido Conjuntivo/cirurgia , Modelos Biológicos , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador , Simulação por Computador , Humanos , Pressão , Estresse Mecânico , Integração de Sistemas
19.
IEEE Trans Inf Technol Biomed ; 16(6): 1216-23, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22855229

RESUMO

A Hospital Information Systems (HIS) have turned a hospital into a gigantic computer with huge computational power, huge storage and wired/wireless local area network. On the other hand, a modern medical device, such as echograph, is a computer system with several functional units connected by an internal network named a bus. Therefore, we can embed such a medical device into the HIS by simply replacing the bus with the local area network. This paper designed and developed two embedded systems, a ubiquitous echograph system and a networked digital camera. Evaluations of the developed systems clearly show that the proposed approach, embedding existing clinical systems into HIS, drastically changes productivity in the clinical field. Once a clinical system becomes a pluggable unit for a gigantic computer system, HIS, the combination of multiple embedded systems with application software designed under deep consideration about clinical processes may lead to the emergence of disruptive innovation in the clinical field.


Assuntos
Redes de Comunicação de Computadores , Sistemas de Informação Hospitalar , Software , Engenharia Biomédica , Humanos , Ultrassonografia
20.
J Med Syst ; 36(4): 2213-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21455698

RESUMO

The movement of create medical information systems that is now taking place involves both progress in EMR (Electronic Medical Records)-computerization of records at hospitals and clinics, and also in EHR (Electronic Health Records) in which information is shared with individual regions. However, the geographical coming and going of people in modern society is extremely active. Naturally the places these people move to are not necessarily within the same region. For this reason, even if the basic unit for the health care supply system is in practical terms limited to the local level, if services are restricted to only one region, many persons may be unable to receive the benefits of health care cooperation. In this study, we constructed a mechanism for a medical cooperation system which links the EHR systems of individual regions and is able to create a one-patient, one-record system on the national level. In this paper, we will provide a report of this mechanism and of the 4-year operational trial.


Assuntos
Redes de Comunicação de Computadores/organização & administração , Sistemas Computadorizados de Registros Médicos/organização & administração , Desenvolvimento de Programas , Japão , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA