Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
PLoS One ; 19(3): e0299597, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38452034

RESUMO

BACKGROUND: Extrusion of electrodes outside the cochlea and tip fold overs may lead to suboptimal outcomes in cochlear implant (CI) recipients. Intraoperative measures such as Trans-Impedance Matrix (TIM) measurements may enable clinicians to identify electrode malposition and direct surgeons to correctly place the electrode array during surgery. OBJECTIVES: To assess the current literature on the effectiveness of TIM measurements in identifying extracochlear electrodes and tip fold overs. METHODS: A scoping review of studies on TIM-based measurements were carried out using the Databases-Medline/PubMed, AMED, EMBASE, CINAHL and the Cochrane Library following PRISMA guidelines. Eleven full texts articles met the inclusion criteria. Only human studies pertaining to TIM as a tool used in CI were included in the review. Further, patient characteristics, electrode design, and TIM measurement outcomes were reported. RESULTS: TIM measurements were available for 550 implanted ears with the subjects age ranged between 9 months to 89 years. Abnormal TIM measurements were reported for 6.55% (36). Tip fold over was detected in 3.64% (20) of the cases, extracochlear electrodes in 1.45% (8), and 1.45% (8) were reported as buckling. Slim-modiolar electrode array designs were more common (54.71%) than pre-curved (23.34%) or lateral wall (21.95%) electrode array. Abnormal cochlear anatomy was reported for five ears (0.89%), with normal cochlear anatomy for all other patients. CONCLUSION: TIM measurement is a promising tool for the intraoperative detection of electrode malposition. TIM measurement has a potential to replace intraoperative imaging in future. Though, TIM measurement is in its early stages of clinical utility, intuitive normative data sets coupled with standardised criteria for detection of abnormal electrode positioning would enhance its sensitivity.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Cóclea/cirurgia , Implante Coclear/métodos , Impedância Elétrica , Eletrodos Implantados , Resultado do Tratamento
2.
Clin Otolaryngol ; 47(6): 641-649, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35833359

RESUMO

OBJECTIVE: To investigate the value of scalp surface potentials to identify and manage partial short circuits to ground in cochlear implant electrodes. DESIGN: A retrospective review of patients with suspected partial short circuits. MAIN OUTCOME MEASURE: Electrical output of individual electrodes was measured using scalp surface potentials for patients reporting a change in hearing function. Electrical output was compared to functional performance and impedance measurements to determine if devices with suspected partial short circuits were experiencing a decrease in performance as a result of reduced electrical output. Electrical output was checked in an artificial cochlea for two implants following explant surgery to confirm scalp surface potential results. RESULTS: All patients with suspected partial short circuits (n = 49) had reduced electrical output, a drop in impedances to approximately ½ of previously stable measurements or to below 2 kΩ, an atypical electrical field measurement (EFI) and a decline in hearing function. Only devices with an atypical EFI showed reduced electrical output. Results of scalp based surface potentials could be replicated in an artificial cochlea following explantation of the device. All explant reports received to date (n = 42) have confirmed partial short circuits, with an additional four devices failing integrity tests. CONCLUSION: Surface potential measurements can detect partial shorts and had 100% correlation with atypical EFI measurements, which are characteristic of a partial short to ground in this device. Surface potentials can help determine the degree to which the electrode array is affected, particularly when behavioural testing is limited or not possible.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea , Implante Coclear/métodos , Impedância Elétrica , Testes Auditivos , Humanos , Couro Cabeludo/cirurgia
3.
Otol Neurotol ; 43(4): 452-459, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35085112

RESUMO

OBJECTIVES: To investigate the combined effect of changing pulse shape and grounding configuration to manage facial nerve stimulation (FNS) in cochlear implant (CI) recipients. PATIENTS: Three adult CI recipients with severe FNS were offered a replacement implant when standard stimulation strategies and programming adjustments did not resolve symptoms. Our hypothesis was that the facial nerve was less likely to be activated when using anodic pulses with "mixed-mode" intra-cochlear and extra-cochlear current return. INTERVENTION: All patients were reimplanted with an implant that uses a pseudo-monophasic anodic pulse shape, with mixed-mode grounding (stimulus mixed-mode anodic)-the Neuro Zti CI (Oticon Medical). This device also allows measurements of neural function and loudness with monopolar, symmetric biphasic pulses (stimulus MB), the clinical standard used by most CIs as a comparison. MAIN OUTCOME MEASURES: The combined effect of pulse shape and grounding configuration on FNS was monitored during surgery. Following CI activation, FNS symptoms and performance with the Neuro Zti implant were compared with outcomes before reimplantation. RESULTS: FNS could only be recorded using stimulus MB for all patients. In clinical use, all patients reported reduced FNS and showed an improvement in Bamford-Kowal-Bench sentences recognition compared with immediately before reimplantation. Bamford-Kowal-Bench scores with a male speaker were lower compared with measurements taken before the onset of severe FNS for patients 1 and 2. CONCLUSIONS: In patients where CI auditory performance was severely limited by FNS, charge-balanced pseudo-monophasic stimulation mode with a mixed-mode grounding configuration limited FNS and improved loudness percept compared with standard biphasic stimulation with monopolar grounding.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Cóclea , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Nervo Coclear , Estimulação Elétrica , Nervo Facial/cirurgia , Humanos , Masculino , Reimplante
4.
Nat Commun ; 12(1): 6260, 2021 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-34716306

RESUMO

Cochlear implants restore hearing in patients with severe to profound deafness by delivering electrical stimuli inside the cochlea. Understanding stimulus current spread, and how it correlates to patient-dependent factors, is hampered by the poor accessibility of the inner ear and by the lack of clinically-relevant in vitro, in vivo or in silico models. Here, we present 3D printing-neural network co-modelling for interpreting electric field imaging profiles of cochlear implant patients. With tuneable electro-anatomy, the 3D printed cochleae can replicate clinical scenarios of electric field imaging profiles at the off-stimuli positions. The co-modelling framework demonstrated autonomous and robust predictions of patient profiles or cochlear geometry, unfolded the electro-anatomical factors causing current spread, assisted on-demand printing for implant testing, and inferred patients' in vivo cochlear tissue resistivity (estimated mean = 6.6 kΩcm). We anticipate our framework will facilitate physical modelling and digital twin innovations for neuromodulation implants.


Assuntos
Materiais Biomiméticos , Cóclea/fisiopatologia , Implantes Cocleares , Aprendizado de Máquina , Impressão Tridimensional , Cóclea/diagnóstico por imagem , Implante Coclear , Espectroscopia Dielétrica , Humanos , Redes Neurais de Computação , Medicina de Precisão/métodos , Reprodutibilidade dos Testes , Microtomografia por Raio-X
5.
Otol Neurotol ; 42(7): 1014-1021, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33710152

RESUMO

OBJECTIVE: To determine if cochlear implantation without removal of inner ear schwannomas (IES) is an effective treatment option for Neurofibromatosis 2 (NF2) patients. To determine how the presence of an intracochlear schwannoma might impact cochlear implant (CI) outcomes and programming parameters. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary center for cochlear and auditory brainstem implantation. PATIENTS: Of 10 NF2 patients with IES, 8 are reported with no previous tumor removal on the implanted ear. INTERVENTIONS: Cochlear implant without tumor removal. MAIN OUTCOME MEASURES: Performance outcomes with CI at least 1-year post intervention. Programming parameters, including impedances, for patients with IES. RESULTS: All patients had full insertion of the electrode arrays with round window approaches. Performance outcomes ranged from 0 to 100% for Bamford-Kowal-Bench sentences. Impedance measurements for active electrodes for patients with IES were comparable to those measured in patients without vestibular schwannoma (VS). Only patients who had radiation treatment before receiving their implant had elevated threshold requirements for CI programming compared with CI recipients without VS. CONCLUSION: Cochlear implantation without tumor removal is an effective option for treating NF2 patients with IES. The presence of an intracochlear tumor did not have an impact on CI performance or programming requirements compared with patients without VS; however, previous treatment with radiation may be related to elevated current requirements in the CI settings.


Assuntos
Implante Auditivo de Tronco Encefálico , Implante Coclear , Implantes Cocleares , Neurofibromatose 2 , Humanos , Neurofibromatose 2/complicações , Neurofibromatose 2/cirurgia , Estudos Retrospectivos
6.
Otol Neurotol ; 41(5): e556-e562, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31985706

RESUMO

OBJECTIVE: To assess the complication rate of magnetic resonance imaging (MRI) using 1.5 T scanners on cochlear implant (CI) and auditory brainstem implant (ABI) recipients over 14.5 years. METHODS: Prospective study conducted in a tertiary referral center for cochlear and auditory brainstem implantation, including patients with neurofibromatosis 2. The primary outcome was complications related to MRI scanning in implant recipients, including failure to complete MRI sessions. The secondary outcome was magnet void size due to MRI scanning with magnet in situ. RESULTS: Ninety-seven patients (21 ABI recipients, 76 CI recipients of whom 23 were bilateral) underwent a total of 428 MRI sessions consisting of 680 MRI procedures, which generated 2,601 MRI sequences (excluding localizers). Of these, 28/428 (6.5%) MRI sessions were performed with magnet removed, and the remaining 400/428 (93.4%) with the magnet in situ. The overall complication rate per session was 15/428 (3.5%). The majority of complications were accounted for by patient discomfort, in some cases requiring abandoning the scan session, but 5 magnet dislocations were also recorded. There were no cases of implant device failure or excessive demagnetization of the receiver stimulator magnet.For CI and ABI recipients, the implant caused large voids of around 110 mm × 60 mm with the magnet in situ which reduced to 60 mm × 30 mm when the magnet was removed. However, it was usually possible to visualize the internal acoustic meatus and cerebellopontine angle by positioning the implant package higher and further forward compared with conventional positioning. CONCLUSION: MRI scanning in ABI and CI recipients is generally safe and well tolerated without magnet removal, and carries a low rate of complications. However, patients should be fully informed of the possibility of discomfort, and precautions such as local anesthetic injection and head bandaging may reduce the likelihood of adverse events.


Assuntos
Implantes Auditivos de Tronco Encefálico , Implante Coclear , Implantes Cocleares , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Estudos Retrospectivos
7.
Otol Neurotol ; 40(10): e966-e974, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31524762

RESUMO

HYPOTHESIS: A novel cochlea implant (CI) device magnet providing alignment to the static field of a magnetic resonance imaging (MRI) will lead to reduced torque, longitudinal forces, and demagnetization effects. The image void and distortion will be comparable to those obtained with standard CI magnets. BACKGROUND: MRI investigations of CI users pose several challenges such as magnet dislocation, demagnetization, and may cause pain. The presence of a CI magnet within MRI field causes image distortions and may diminish the diagnostic value of an MRI procedure. Objective of this work is to evaluate magnetic forces and imaging properties of the novel CI magnet within 1.5 and 3T MRI. METHODS: Forces and torque of the novel CI magnet were measured in both 1.5 and 3T MRI and compared with the standard magnet in 1.5T. One cadaver head was implanted with the CI devices containing the novel and standard magnets in different configurations reflecting clinical scenarios and imaging properties were assessed and compared. RESULTS: In particular the torque has been reduced with the novel CI magnet in comparison to the standard one. Both CI magnets have not shown any signs of demagnetization. The image void and distortion was comparable between the two magnets for the main MRI clinical scanning protocols in 1.5T MRI. CONCLUSIONS: The novel CI magnet is safe to use for MRI investigations of CI users in 3T MRI without a need for bandaging and has acceptable level of image artefacts.


Assuntos
Artefatos , Implantes Cocleares , Imageamento por Ressonância Magnética , Cadáver , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Imãs , Torque
8.
J Neurol Surg Rep ; 80(1): e1-e9, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30723658

RESUMO

Objectives A decision on whether to insert a cochlear implant can be made in neurofibromatosis 2 (NF2) if there is objective evidence of cochlear nerve (CN) function post vestibular schwannoma (VS) excision. We aimed to develop intraoperative CN monitoring to help in this decision. Design We describe the intraoperative monitoring of a patient with NF2 and our stimulating and recording set up. A novel test electrode is used to stimulate the CN electrically. Setting This study was set at a tertiary referral center for skull base pathology. Main outcome measure Preserved auditory brainstem responses leading to cochlear implantation. Results Electrical auditory brainstem response (EABR) waveforms will be displayed from different stages of the operation. A cochlear implant was inserted at the same sitting based on the EABR. Conclusion Electrically evoked CN monitoring can provide objective evidence of CN function after VS excision and aid in the decision-making process of hearing rehabilitation in patients who will be rendered deaf.

9.
J Assoc Res Otolaryngol ; 20(2): 169-185, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30543016

RESUMO

A series of experiments investigated potential changes in temporal processing during the months following activation of a cochlear implant (CI) and as a function of stimulus level. Experiment 1 tested patients on the day of implant activation and 2 and 6 months later. All stimuli were presented using direct stimulation of a single apical electrode. The dependent variables were rate discrimination ratios (RDRs) for pulse trains with rates centred on 120 pulses per second (pps), obtained using an adaptive procedure, and a measure of the upper limit of temporal pitch, obtained using a pitch-ranking procedure. All stimuli were presented at their most comfortable level (MCL). RDRs decreased from 1.23 to 1.16 and the upper limit increased from 357 to 485 pps from 0 to 2 months post-activation, with no overall change from 2 to 6 months. Because MCLs and hence the testing level increased across sessions, two further experiments investigated whether the performance changes observed across sessions could be due to level differences. Experiment 2 re-tested a subset of subjects at 9 months post-activation, using current levels similar to those used at 0 months. Although the stimuli sounded softer, some subjects showed lower RDRs and/or higher upper limits at this re-test. Experiment 3 measured RDRs and the upper limit for a separate group of subjects at levels equal to 60 %, 80 % and 100 % of the dynamic range. RDRs decreased with increasing level. The upper limit increased with increasing level for most subjects, with two notable exceptions. Implications of the results for temporal plasticity are discussed, along with possible influences of the effects of level and of across-session learning.


Assuntos
Percepção Auditiva , Implantes Cocleares , Idoso , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
10.
Cochlear Implants Int ; 18(3): 171-179, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28335700

RESUMO

OBJECTIVE: Review of cochlear implant (CI) outcomes in patients with Neurofibromatosis Type 2 (NF2), implanted in the presence of an ipsilateral vestibular schwannoma (VS). Hearing restoration was combined in some cases with a Bevacizumab regime. METHOD: Retrospective review of 12 patients, managed over the period 2009-2016, at a tertiary referral multidisciplinary NF2 clinic. The patients are grouped by hearing outcomes to explore likely protective factors, and to generate a proposed decision-making tool for the selection of either CI or Auditory Brainstem Implant (ABI). RESULTS: Four of the 12 patients achieved speech discrimination without lip-reading. In these individuals there is reason to think that the mechanism of their hearing loss was cochlear dysfunction. A further four patients received benefit to lip-reading and awareness of environmental sound. For such patients their hearing loss may have been due to both cochlear and neural dysfunction. Two patients gained access to environmental sound only from their CI. Two patients derived no benefit from their CIs, which were subsequently explanted. Both these latter patients had had prior ipsilateral tumour surgery, one just before the CI insertion. CONCLUSION: Cochlear implantation can lead to open set speech discrimination in patients with NF2 in the presence of a stable VS. Use of promontory stimulation and intraoperative electrically evoked auditory brainstem response testing, along with case history, can inform the decision whether to implant an ABI or CI.


Assuntos
Implante Coclear/métodos , Implantes Cocleares , Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva/cirurgia , Neurofibromatose 2/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Implante Auditivo de Tronco Encefálico/métodos , Feminino , Perda Auditiva/etiologia , Perda Auditiva/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Neurofibromatose 2/fisiopatologia , Seleção de Pacientes , Estudos Retrospectivos , Percepção da Fala , Resultado do Tratamento , Adulto Jovem
11.
Otol Neurotol ; 36(9): 1472-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26375968

RESUMO

OBJECTIVE: To assess differences in pitch-ranking ability across a range of speech understanding performance levels and as a function of electrode position. STUDY DESIGN: An observational study of a cross-section of cochlear implantees. SETTING: Tertiary referral center for cochlear implantation. PATIENTS: A total of 22 patients were recruited. All three manufacturers' devices were included (MED-EL, Innsbruck, Austria, n = 10; Advanced Bionics, California, USA, n = 8; and Cochlear, Sydney, Australia, n = 4) and all patients were long-term users (more than 18 months). Twelve of these were poor performers (scores on BKB sentence lists <60%) and 10 were excellent performers (BKB >90%). INTERVENTION: After measurement of threshold and comfort levels, and loudness balancing across the array, all patients underwent thorough pitch-ranking assessments at 80% of comfort levels. MAIN OUTCOME MEASURE: Ability to discriminate pitch across the electrode array, measured by consistency in discrimination of adjacent pairs of electrodes, as well as an assessment of the pitch order across the array using the midpoint comparison task. RESULTS: Within the poor performing group there was wide variability in ability to pitch rank, from no errors, to a complete inability to reliably and consistently differentiate pitch change across the electrode array. Good performers were overall significantly more accurate at pitch ranking (p = 0.026). Consistent pitch ranking was found to be a significant independent predictor of BKB score, even after adjusting for age. Users of the MED-EL implant experienced significantly more pitch confusions at the apex than at more basal parts of the electrode array. CONCLUSIONS: Many cochlear implant users struggle to discriminate pitch effectively. Accurate pitch ranking appears to be an independent predictor of overall outcome. Future work will concentrate on manipulating maps based upon pitch discrimination findings in an attempt to improve speech understanding.


Assuntos
Implante Coclear , Surdez/reabilitação , Discriminação da Altura Tonal , Idoso , Implantes Cocleares , Estudos Transversais , Surdez/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Percepção da Altura Sonora
12.
Otol Neurotol ; 35(5): 821-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24608375

RESUMO

OBJECTIVE: To assess the impact on image quality of MRI without magnet removal in cochlear implant (CI) and auditory brainstem implant (ABI) users with neurofibromatosis type 2 (NF2). STUDY DESIGN: Prospective cohort. SETTING: Tertiary center for cochlear and auditory brainstem implantation. PATIENTS: Thirteen patients (10 ABI, 3CI) with NF2 underwent a total of 76 MRI scans. INTERVENTIONS: MRI without magnet removal. MAIN OUTCOME MEASURE: Ability to visualize the ipsilateral and contralateral cerebellopontine angles (CPAs) and internal auditory meati (IAM) with head MRI. RESULTS: Of the 76 scans, 40 were of the head, 28 of the spine and 8 of other regions. Scanning was performed with a tight head bandage and plastic card. There were no cases of altered implant function or demagnetization of the device magnet.A grading system was used to assess the view of the ipsilateral IAM-CPA. In 85% of head scans, the view was unimpaired (Grade 0). In 13%, there was distortion (Grade 1). In 2% (1 case), the view was entirely obscured by artifact (Grade 2). Views of the contralateral CPA and IAM were unimpaired in all cases. The best 3 sequences for the depiction of the ipsilateral IAM-CPA (percent graded as 0) were as follows: axial 3D inversion recovery prepared fast spoiled gradient echo (100%), 2 mm coronal T1W of the IAM-CPA (88.9%), and 2 mm axial T1W of the IAM-CPA (76.9%). CONCLUSION: MRI scanning without magnet removal is safe and well tolerated in NF2 patients with auditory implants. With appropriate MRI sequences, the image quality is not significantly impaired.


Assuntos
Implantes Auditivos de Tronco Encefálico , Encéfalo/patologia , Implantes Cocleares , Imageamento por Ressonância Magnética/métodos , Neurofibromatose 2/patologia , Adolescente , Adulto , Idoso , Neoplasias Cerebelares/patologia , Ângulo Cerebelopontino/patologia , Feminino , Humanos , Imãs , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/patologia , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA