1.
J Orthop Sci ; 29(2): 559-565, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36801090

RESUMO

BACKGROUND: This study evaluated the accuracy of the cup alignment angles and spatial cup positioning on computed tomography (CT) images in patients with osteoarthritis secondary to developmental dysplasia of the hip (DDH) who underwent total hip arthroplasty (THA) using a minimally invasive technique via an anterolateral approach in the supine position according to whether a robotic arm-assisted system or a CT-based navigation system was used. METHODS: We reviewed 60 robotic arm-assisted (RA)-THA cases and 174 navigation-assisted (NA)-THA cases. After propensity score matching, there were 52 hips in each group. Postoperative cup alignment angles and position were assessed by superimposition of a three-dimensional cup template onto the actual implanted cup using postoperative CT images with pelvic coordinates matching the preoperative planning. RESULTS: The mean absolute error of the inclination angle and the anteversion angle between the preoperative planning and the postoperative measurement was significantly smaller in the RA-THA group (inclination, 1.1° ± 0.9; anteversion, 1.3° ± 1.0) than in the NA-THA group (inclination, 2.2° ± 1.5; anteversion, 3.3° ± 2.5). For acetabular cup positioning, the mean discrepancy between the preoperative planning and the postoperative measurement was 1.3 ± 1.3 mm on the transverse axis, 2.0 ± 2.0 mm on the longitudinal axis, and 1.3 ± 1.7 mm on the sagittal axis in the RA-THA group and 1.6 ± 1.4 mm, 2.6 ± 2.3 mm, and 1.8 ± 1.3 mm, respectively, in the NA-THA group. High precision of cup positioning was observed in both groups with no statistically significant difference. CONCLUSION: Robotic arm-assisted THA using a minimally invasive technique via an anterolateral approach in the supine position allows accurate cup placement in patients with DDH.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia de Quadril/métodos , Decúbito Dorsal , Acetábulo/cirurgia , Cirurgia Assistida por Computador/métodos
2.
J Bone Miner Metab ; 42(1): 60-68, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38057602

RESUMO

INTRODUCTION: Trabecular bone score (TBS) is partially independent of fracture risk. Reference values for TBS have not been established in official guidelines, and thus clinicians often have difficulty interpreting TBS results. This study aimed to investigate whether reference values for TBS could be a valid indicator for clinical vertebral fracture (CVF). MATERIALS AND METHODS: This cross-sectional study involved 231 women with CVF and 563 women without CVF aged 60-90 years who underwent dual-energy X-ray absorptiometry during 2019-2023. They were divided into osteoporosis, osteopenia, and normal groups according to bone mineral density of the lumbar spine. Reference values for TBS were defined as low (≤ 1.23), intermediate (1.23-1.31), and high (≥ 1.31). RESULTS: Among patients without anti-osteoporosis treatment (n = 476), the proportion with low TBS was 36.7% in the CVF group and 10.7% in the control group. The proportion with CVF was higher in the low TBS group than in the intermediate and high TBS groups, especially in the osteoporosis group (p < 0.001). The odds ratio for CVF was higher in the low TBS group than in the intermediate and high especially in patients with normal BMD and osteoporosis. The TBS cut-off values for incidence of CVF in the osteoporosis, osteopenia, and normal groups were 1.224, 1.319, and 1.322, respectively. CONCLUSIONS: The reference value for low TBS (≤ 1.23) was useful as an indicator for CVF, especially in patients with osteoporosis. It is expected that reference values for TBS will be established in official guidelines in the future.


Assuntos
Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Feminino , Fraturas da Coluna Vertebral/epidemiologia , Estudos Transversais , Valores de Referência , Osso Esponjoso , Osteoporose/diagnóstico por imagem , Osteoporose/complicações , Densidade Óssea , Absorciometria de Fóton , Vértebras Lombares/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia
3.
J Occup Med Toxicol ; 18(1): 27, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38037166

RESUMO

BACKGROUND: Fluoroscopy is indispensable when determining appropriate and effective interventions in orthopedic surgery. On the other hand, there is growing concern about the health hazards of occupational radiation exposure. The aim of this cadaveric simulation study was to measure radiation exposure doses to the surgical team during hip surgery. METHODS: We reproduced the intraoperative setting of hip surgery using 7 fresh frozen cadavers (5 male, 2 female) to simulate patients and mannequins to simulate the surgeon, scrub nurse, and anesthesiologist. Six real-time dosimeters were mounted at sites corresponding to the optic lens, thyroid gland, chest, gonads, foot, and hand on each mannequin. The radiation exposure dose to each team member was measured during posteroanterior and lateral fluoroscopic imaging. RESULTS: Radiation exposure doses to the surgeon were significantly higher during 3 min of lateral imaging than during 3 min of posteroanterior imaging at the optic lens (8.1 times higher), thyroid gland (10.3 times), chest (10.8 times), and hand (19.8 times) (p = 0.018, p = 0.018, p = 0.018, and p = 0.018, respectively). During lateral imaging, the radiation doses to the nurse were 0.16, 0.12, 0.09, 0.72, and 0.38 times those to the surgeon at the optic lens, thyroid, chest, gonads, and foot, respectively. The radiation dose to the anesthesiologist was zero at all anatomic sites during posteroanterior imaging and very small during lateral imaging. CONCLUSIONS: Radiation exposure dose was significantly higher during lateral imaging up to 19.8 times comparing to the posteroanterior imaging. It is effective to reduce the lateral imaging time for reducing the intraoperative radiation exposure. In addition, appropriate distance from fluoroscopy resulted in very low exposure for nurses and anesthesiologists. Surgeon should pay attention that surgical staff do not get closer than necessary to the irradiation field.

4.
J Robot Surg ; 17(6): 2831-2839, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37755679

RESUMO

The purpose of this study was to directly compare implant placement accuracy and postoperative limb alignment between robotic-assisted total knee arthroplasty and navigation-assisted total knee arthroplasty. This retrospective case-control study included a consecutive series of 182 knees (robotic-assisted group, n = 103 knees; navigation-assisted group, n = 79). An image-free handheld robotic system (NAVIO) or an image-free navigation system (Precision N) was used. Component and limb alignment were evaluated on three-dimensional computed tomography scans and full-length standing anterior-posterior radiographs. We compared the errors between the final intraoperative plan and the postoperative coronal and sagittal alignment of the components and the hip-knee-ankle angle between the two groups. The orientation of the femoral and tibial components in the coronal plane were more accurate in the robotic-assisted group than in the navigation-assisted group (p < 0.05). There was no significant difference in the orientation of the femoral and tibial component in the sagittal plane between the two groups. There were fewer outliers in the tibial coronal plane in the robotic-assisted group (p < 0.05). There was also no significant difference in the frequency of outlying values for coronal or sagittal alignment of the femoral component or sagittal alignment of the tibial component or the hip-knee-ankle angle between the two groups. Robotic-assisted total knee arthroplasty using a handheld image-free system improved component alignment in the coronal plane compared with total knee arthroplasty using an image-free navigation system. Robotic surgery helps surgeons to achieve personalised alignment that may result in better clinical outcomes.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia Assistida por Computador/métodos
5.
Spine Surg Relat Res ; 7(4): 341-349, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37636144

RESUMO

Introduction: The harmful effects of long-term low-dose radiation have been well known. There are few comprehensive reports evaluating concrete real exposure doses for each part of a surgeon, assistant surgeon, scrub nurse, and anesthesiologist associated with fluoroscopic spinal procedures. This research aimed to quantify the radiation exposure dose to surgical team members during C-arm fluoroscopy-guided spinal surgery. Methods: Seven fresh cadavers were irradiated for 1 and 3 min with C-arm fluoroscopy. The position of the X-ray source was under the table, over the table, and laterally. The radiation exposure doses were measured at the optic lens, thyroid gland, and hand in mannequins used to simulate surgical team members. Results: A significant difference was observed in the radiation exposure dose according to the position of the X-ray source and the irradiated body area. The risk of scatter radiation exposure was the biggest for the lateral position (nearly 30-fold that for the position under the table). All radiation exposure doses were positively correlated with irradiation time. Conclusions: The occupational radiation exposure dose to surgical team members during C-arm fluoroscopy-guided lumbar spinal procedures varies according to the X-ray source position. Our findings would help surgical team members to know the risk of radiation exposure during various fluoroscopic procedures. Surgeons in particular need to reduce their radiation exposure by using appropriate shielding and technique.

6.
J Surg Case Rep ; 2023(6): rjad355, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37342523

RESUMO

Klebsiella pneumoniae has the ability to form biofilm; therefore, the treatment of prosthetic joint infection involving K. pneumoniae is often challenging. This report describes the first case of acute hematogenous prosthetic knee joint infection with K. pneumoniae that occurred as a result of an asymptomatic gallbladder abscess. The patient was a 78-year-old man who underwent bilateral total knee arthroplasty 6 years ago. He had pain and swelling in his right knee. The synovial fluid culture of the right knee revealed K. pneumoniae and prosthetic joint infection was diagnosed. Computed tomography revealed a gallbladder abscess in the absence of right upper abdominal pain. The patient underwent simultaneous debridement of the knee and open cholecystectomy. The treatment was successful and the prosthesis was retained. In cases of hematogenous prosthetic joint infection with K. pneumoniae, other sources of infection should be suspected and investigated regardless of whether they are symptomatic.

7.
Knee ; 42: 289-296, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37120864

RESUMO

BACKGROUND: Although bicruciate stabilized total knee arthroplasty (BCS-TKA) is expected to provide kinematics similar to those of the normal knee, there are limited data available for comparison of the kinematics of the knee after BCS-TKA with those of the normal knee. The purpose of this study was to confirm whether the knee after BCS-TKA are the same as those of the native knee. METHODS: Seven fresh-frozen cadavers underwent TKA using a BCS-type prosthesis with navigation system. Anteroposterior translation of the femur and internal rotation of the tibia were evaluated using the navigation system. RESULTS: There was no statistically significant difference in anteroposterior translation of the femur between the native knee and the knee after BCS-TKA in the early flexion phase (0°-30°) or in the deep flexion phase (over 100°). In the middle flexion phase (40°-90°), the knee after BCS-TKA was placed significantly more anteriorly than the native knee. The knee after BCS-TKA also showed a gradual internal rotation pattern similar to that of the native knee but the total tibial internal rotation angle was significantly smaller than that of the native knee. At each angle from 0° to 120° of flexion, internal rotation of the knee after BCS-TKA was significantly greater than that of the native knee. CONCLUSION: Kinematics of BCS-TKA is close to that of the native knee. However, there is a statistically significant difference in AP position of the femur during mid flexion and initial rotational position of the tibia between the BCS-TKA knee and the native knee.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Fenômenos Biomecânicos , Cadáver , Joelho/cirurgia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia
8.
J Orthop Sci ; 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37055272

RESUMO

PURPOSE: Patient-perceived leg length discrepancy (PLLD) is one of the major postoperative complications of total hip arthroplasty (THA). This study aimed to identify factors that cause PLLD following THA. MATERIALS AND METHODS: This retrospective study included a series of consecutive patients who underwent unilateral THA between 2015 and 2020. Ninety-five patients who underwent unilateral THA with postoperative radiographic leg length discrepancy (RLLD) ≤1 cm were classified into two groups according to the direction of preoperative pelvic obliquity (PO). Standing radiographs of the hip joint and whole spine were obtained before and one year after THA. The clinical outcomes and the presence or absence of PLLD was confirmed one year after THA. RESULTS: Sixty-nine patients were classified as having type 1 PO (rising toward the unaffected side) and 26 were classified as having type 2 PO (rising toward the affected side). Eight patients with type 1 PO and seven with type 2 PO had PLLD postoperatively. In the type 1 group, patients with PLLD had larger preoperative and postoperative PO values and larger preoperative and postoperative RLLD than those without PLLD (p = 0.01, p < 0.001, p = 0.01, and p = 0.007, respectively). In the type 2 group, patients with PLLD had larger preoperative RLLD, larger amount of leg correction, and a larger preoperative L1-L5 angle than those without PLLD (p = 0.03, p = 0.03, and p = 0.03, respectively). In type 1, postoperative PO was significantly associated with postoperative PLLD (p = 0.005), but spinal alignment was not an indicator of postoperative PLLD. The area under the curve (AUC) for postoperative PO was 0.883 (good accuracy) with a cut-off value was 1.90° CONCLUSION: Rigidity of the lumbar spine might lead to postoperative PO as a compensatory movement, resulting in PLLD after THA in type 1. Further research on the relationship between flexibility of the lumbar spine and PLLD is needed.

9.
Sci Rep ; 13(1): 3492, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859708

RESUMO

Iliopsoas impingement after total hip arthroplasty is caused by the implant irritating the iliopsoas muscle, but changes in the iliopsoas muscle have not been quantitatively evaluated. This study assessed changes in the surface pressure of the iliopsoas muscle when the implant alignment was varied. Total hip arthroplasty was performed in 10 fresh-frozen cadaveric hips. We evaluated the maximum and mean surface pressure of the iliopsoas muscle with the hip in 20° and 10° extension, the neutral position, and 10° flexion when the anterior cup protrusion length (ACPL), stem version, and stem offset were varied. When the ACPL was changed to 0, 3, and 6 mm in 20° extension, the maximum surface pressure was significantly increased for ACPL of 6 mm compared with 0 mm. Decreased stem anteversion resulted in a significant reduction in both the maximum and mean surface pressure compared with native anteversion from 20° extension to the neutral position. Increased stem offset resulted in significant increases in the maximum and mean surface pressure of the iliopsoas muscle compared with decreased stem offset in 20° extension. Not only large ACPL but also changes in stem version and offset affected the maximum surface pressure of the iliopsoas muscle.


Assuntos
Artroplastia de Quadril , Humanos , Cadáver , Músculos , Próteses e Implantes
10.
Hip Int ; 33(6): 985-991, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36210742

RESUMO

BACKGROUND: Iliopsoas impingement (IPI) is a known complication of total hip arthroplasty (THA). The aim of this study was to identify risk factors and the cut-off cup protrusion length for symptomatic IPI. METHODS: We retrospectively reviewed 218 hips (46 men, 172 women) of 190 consecutive Japanese patients who underwent primary THA at our institution. Hips with IPI (n = 24) and control hips (n = 194) were compared according to age, body mass index, and clinical scores. We evaluated leg-length discrepancy, global offset, implant alignment angles, pelvic inclination, and anterior cup protrusion on plain radiographs and computed tomography scans. RESULTS: Symptomatic IPI had an incidence of 11.0% and a predilection for hips with osteonecrosis. Pre- and postoperative hip flexion angles were significantly greater in hips with symptomatic IPI (p = 0.013 and p = 0.006, respectively). Cup protrusion length was significantly greater in hips with IPI (4.7 mm vs. 1.4 mm; p = 0.001). Receiver-operating characteristic curve analysis identified a threshold cup protrusion length of 3.9 mm (sensitivity 0.89, specificity 0.63) for symptomatic IPI. The incidence of symptomatic IPI tended to be lower in patients with greater posterior pelvic sagittal inclination despite the cup protrusion length being greater. CONCLUSIONS: An increased hip flexion angle and protrusion of the anterior acetabular component predicted symptomatic IPI. The threshold cup protrusion length suggesting mild IPI might be about 3.9 mm and could be useful for identifying candidates for conservative treatment.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Masculino , Humanos , Feminino , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Quadril/cirurgia , Músculo Esquelético/cirurgia , Prótese de Quadril/efeitos adversos
11.
J Orthop Res ; 40(12): 2885-2893, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35266582

RESUMO

An adequate soft tissue balance is important in total hip arthroplasty (THA). This study assessed the contribution of the iliofemoral ligament, ischiofemoral ligament, and conjoined tendon to the range of hip rotation after THA and hip stability in response to axial traction. THA was performed in eight fresh-frozen cadaveric specimens via an anterolateral approach using a navigation system. The ischiofemoral ligament, the medial arm of the iliofemoral ligament, and the conjoined tendon were resected in that order. The ranges of external and internal rotation and the amount of movement of the femoral head in response to axial traction were measured with the hip in 10° of extension, the neutral position, and in 10°, 30°, and 60° of flexion. Resection of the medial arm of the iliofemoral ligament significantly increased the range of external rotation in 10° of extension, the neutral position, and in 10°, 30°, and 60° of flexion. The conjoined tendon was the most important inhibitor of internal rotation from 10° of extension to 30° of flexion. Although each single element had a minor role in stabilizing the hip when axial traction was applied, resection of two or more elements significantly affected joint stability. The iliofemoral ligament and conjoined tendon are the main inhibitors of external rotation and internal rotation, respectively, when THA is performed using an anterior or anterolateral approach. Resection of two or more elements could greatly affect hip stability when axial traction is applied.


Assuntos
Artroplastia de Quadril , Humanos , Fenômenos Biomecânicos , Cadáver , Ligamentos Articulares/cirurgia , Ligamentos Articulares/fisiologia , Amplitude de Movimento Articular/fisiologia , Tendões
12.
J Orthop Sci ; 27(1): 163-168, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33341353

RESUMO

BACKGROUND: A highly porous titanium cup has a unique structure that mimics human trabecular bone and is expected to achieve better outcomes due to rigid fixation and extensive bone ingrowth. Several manufacturers have developed a highly porous titanium cup; however, some have shown a high incidence of radiolucent lines (RLLs) on early postoperative radiographs. In this study, we compared the clinical and radiological outcomes of total hip arthroplasty (THA) using a highly porous titanium cup (OsseoTi, Zimmer Biomet) with those after THA using a conventional hydroxyapatite-coated titanium cup (Trident HA, Stryker). METHODS: A total of 201 hips that underwent THA using an OsseoTi cup (n = 101) or Trident cup (n = 100) were enrolled in the study. Patient characteristics, cup alignment, clinical outcome (determined by the Japanese Orthopedic Association [JOA] score), and incidence of RLLs around the cup were evaluated at 3, 6, 12, and 24 months postoperatively. RESULTS: The clinical outcome was excellent in both groups. The incidence of RLLs was 12.9% at 3 months, 20.8% at 6 months, 23.8% at 12 months, and 22.8% at 24 months after surgery in the OsseoTi group; there were no cases of RLL at any time after surgery in the Trident group. The RLLs were mainly distributed in zone 2. Despite the high rate of RLL in the OsseoTi group, the RLL were narrow and only 5% had a width of >1 mm at 24 months postoperatively. There were no cases with RLLs in all three zones. CONCLUSIONS: Despite excellent clinical outcomes in both study groups, the incidence of RLLs was higher in the OsseoTi group than in the Trident group. Although none of our cases with RLL have required revision surgery for aseptic loosening so far, these patients require careful follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Durapatita , Humanos , Japão/epidemiologia , Porosidade , Desenho de Prótese , Estudos Retrospectivos , Titânio
13.
Knee ; 28: 311-318, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33477002

RESUMO

BACKGROUND: Soft tissue balancing in bicruciate-retaining (BCR) total knee arthroplasty (TKA) is a challenge that must be overcome to achieve excellent clinical outcomes. However, the optimal degree of joint laxity has yet to be clarified. This cadaveric study sought to examine joint laxity after BCR TKA using a navigation system. METHODS: Knee joint laxity was quantified using an image-free navigation system in 8 intact fresh frozen cadavers under three conditions: the native knee, BCR TKA knee, and BCR TKA knee after anterior cruciate ligament resection. Rotational kinematics in the BCR TKA knee during flexion were compared according to whether joint laxity was increased or decreased. RESULTS: Knee joint laxity after BCR TKA under varus-valgus movement, anterior translation, and internal-external rotation loadings was similar to that of the native knee. However, lateral joint laxity was decreased during flexion in some cases. BCR TKA-treated knees with decreased lateral joint laxity at 90° of flexion demonstrated more limited tibial internal rotation in deep flexion than the native knee (p < 0.05). The loss of internal rotation in deep flexion was partly recovered by using a lateral insert with a posterior slope of +3°. CONCLUSIONS: Restoring optimal joint laxity was not always straightforward in BCR TKA if the 4 ligaments were preserved. Lateral joint laxity was potentially decreased in BCR TKA and may result in kinematic conflict during flexion. Surgeons should be aware of the need to achieve sufficient lateral joint laxity in this type of BCR TKA.


Assuntos
Artroplastia do Joelho/efeitos adversos , Instabilidade Articular/etiologia , Articulação do Joelho/fisiopatologia , Prótese do Joelho/efeitos adversos , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Articulação do Joelho/cirurgia , Masculino
14.
BMC Musculoskelet Disord ; 21(1): 828, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33298008

RESUMO

BACKGROUND: An understanding of the insertional footprints of the capsular ligaments of the hip is important for preserving hip function and stability given the increasing number of minimally invasive hip surgeries being performed under a limited surgical view. However, it is difficult to detect these ligaments intraoperatively and many surgeons may not fully appreciate their complex anatomy. The aims of this study were to quantify the proximal and distal footprints of the iliofemoral ligament (ILFL) and ischiofemoral ligament (ISFL) and to estimate the location of the corresponding osseous landmarks on the proximal femur, which can be detected easily during surgery. METHODS: Twelve hip joints from Japanese fresh frozen cadavers were used. All muscle, fascia, nerve tissue, and vessels were removed to expose the intact capsular ligaments of the hip. The length and width of the proximal and distal footprints of the ILFL and ISFL were measured and their relationship to osseous structures was evaluated, including the intertrochanteric line, femoral neck, and lesser trochanter. RESULTS: The mean length of the distal medial arm of the ILFL footprint was 17.9 mm and the mean width was 9.0 mm. The mean length of the distal lateral arm of the ILFL footprint was 23.0 mm and the mean width was 9.7 mm. For the footprint of the medial arm, the insertion was in the distal third of the intertrochanteric line and that of the lateral arm was in the proximal 42% of this line. The mean distance from the lesser trochanter to the footprint of the medial arm was 24.6 mm. The mean length of the distal ISFL footprint was 11.3 mm and the mean width was 6.9 mm. The footprint of the distal ISFL was located forward of the femoral neck axis in all specimens. CONCLUSIONS: Understanding the size and location of each capsular ligament footprint in relation to an osseous landmark may help surgeons to manage the hip capsule intraoperatively even under a narrow surgical view. The findings of this study underscore the importance of recognizing that the distal ISFL footprint is located relatively forward and very close to the distal lateral arm footprint.


Assuntos
Articulação do Quadril , Ligamentos Articulares , Cadáver , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Humanos , Ligamentos Articulares/cirurgia
15.
J Med Invest ; 67(1.2): 214-216, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32378613

RESUMO

The Rotational osteotomy for femoral retroversion has been extremely rare despite the known association between femoral neck retroversion, hip pain, and osteoarthritis. Here, we describe a case of femoral neck retroversion for which proximal femoral rotation osteotomy. A 16-year-old boy with a past history of developmental dysplasia of the both hip treated conservatively presented with a complaint of pain in left hips. On physical examination, flexion of the left hip was limited to 90° with terminal pain. Internal rotation was also limited to 10°. Computed tomography (CT) showed -7.1° anteversion of the left femur. We performed rotational osteotomy to increase femoral anteversion because conservative treatment was not effective. The postoperative course was uneventful. At 12 postoperative months, his left hip pain was completely disappeared and femoral anteversion was 34° on CT scans. Retroversion of the femur is a distinct dynamic factor that should be considered in the evaluation of mechanical causes of hip pain. Restoring the normal rotational alignment of the hip resulted in cure of the impingement due to femoral retroversion. J. Med. Invest. 67 : 214-216, February, 2020.


Assuntos
Retroversão Óssea/cirurgia , Impacto Femoroacetabular/cirurgia , Colo do Fêmur/patologia , Osteotomia/métodos , Adolescente , Retroversão Óssea/diagnóstico por imagem , Impacto Femoroacetabular/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Humanos , Masculino , Tomografia Computadorizada por Raios X
16.
Case Rep Orthop ; 2019: 9378632, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31772803

RESUMO

Lesions of the anterior cruciate ligament (ACL) are rare entities in clinical practice. Here, we present the case of an intraligamentous hematoma of the ACL. A 20-year-old man (height 173 cm, weight 62.9 kg, body mass index 21) with no significant past medical history developed progressively worsening pain and limitation of range of motion in the left knee due to minor trauma. No abnormality was found on plain radiography; however, magnetic resonance imaging revealed a cystic lesion in the intercondylar fossa that was hypointense on T1-weighted imaging and hyperintense on T2-weighted imaging. We performed knee arthroscopy, made a longitudinal incision in the anterior aspect of the ACL, and identified a hematoma. The patient's postoperative course was uneventful. There is no evidence of recurrence at one year after surgery. Although the ACL is a relatively hypovascular structure, it does contain microscopic blood vessels. In this case, we speculate that the intraligamentous hematoma was the result of rupture of these very small blood vessels in response to a minor injury.

17.
Spine Surg Relat Res ; 2(4): 299-303, 2018 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-31435538

RESUMO

INTRODUCTION: A high-intensity zone (HIZ) in an intervertebral disc of the lumbar spine is a high-intensity signal located in the posterior annulus fibrosus on T2-weighted magnetic resonance imaging (MRI). There is limited information on the prevalence of HIZ in the lumbar spine according to age. The aim of this cross-sectional study was to investigate the prevalence of HIZ in the lumbar spine by age and the correlation between HIZ and other degenerative findings, such as disc degeneration, disc bulging and herniation, and changes in adjacent vertebral endplates on lumbar MRI. METHODS: We retrospectively reviewed MRI studies of 305 patients (1525 discs) with low back pain, leg pain, or numbness. The prevalence of HIZ was calculated in 5 age groups (<20, 20-39, 40-59, 60-79, 80-91 years). RESULTS: The number of patients in the 5 age groups was 19, 38, 69, 145, and 36, respectively. The prevalence of HIZ in the 5 age groups was 11.8%, 47.3%, 52.2%, 42.8%, and 50.0%, respectively. Disc degeneration was observed in 58.1% and 39.2% of discs with and without HIZ, respectively; disc bulging and herniation was observed in 63.9% and 41.1% and intensity changes at adjacent end plates in 11.6% and 10.0%, respectively. CONCLUSIONS: Prevalence of HIZ from the third decade of life onward was around 50%, with no significant change in prevalence beyond the age of 20 years. HIZ was correlated with disc degeneration, disc bulging, and disc herniation in patients with LBP, leg pain, or numbness.

18.
Case Rep Orthop ; 2017: 2594902, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29098102

RESUMO

Here we present a case of pseudotumor following total hip arthroplasty (THA) that resulted in a circulatory disturbance caused by compression of the femoral vasculature. A 63-year-old man presented with pain, swelling, and redness of the left leg 5 years after primary metal-on-metal THA using the AML-Plus stem, Pinnacle® acetabular cup, and 36 mm diameter Ultamet™ metal head system (DePuy Orthopaedics, Warsaw, IN). Enhanced computed tomography and magnetic resonance imaging revealed a large cystic lesion extending from the left hip anteriorly to the intrapelvic region and compressing the left femoral vessels. Percutaneous puncture of the lesion yielded a dark red aspirate and the patient was diagnosed to have a pseudotumor causing compression of the femoral vessels. We performed revision surgery to replace the metal head and metal liner with a smaller ceramic head and polyethylene liner without removal of the stem. Corrosion of the head-neck junction was identified intraoperatively with no obvious wear on the bearing surfaces. The left leg swelling and redness improved immediately postoperatively. A large pseudotumor should be kept in mind as a cause of vascular compression with unilateral leg edema in a patient who has undergone metal-on-metal THA.

19.
J Orthop Sci ; 22(4): 722-725, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28431804

RESUMO

AIMS: The common treatment for an undisplaced femoral neck fracture is osteosynthesis. Two major complications of osteosynthesis are non-union and late collapse of the femoral head. We speculated that femoral head perfusion is one of the most important factors that affect the outcome of osteosynthesis after femoral neck fracture. We have preoperatively estimated femoral head perfusion by dynamic MRI positive enhancement integral color mapping (PEICM). The purpose of this study was to evaluate the outcomes of undisplaced femoral neck fractures based on PEICM. PATIENTS AND METHODS: Sixty-eight patients participated in this prospective study. All patients underwent PEICM in a 1.5-Tesla MRI machine using coronal fast spoiled gradient echo imaging sequences with gadopentetate dimeglumine as the contrast agent. Femoral head perfusion was displayed via color mapping using PEICM. Three types were distinguished. For type A, the color was identical to unaffected side indicated normal perfusion. For type B, the color was darker than unaffected side indicated decreased perfusion. For type C, the color was black indicated complete absence of perfusion. All patients underwent osteosynthesis with three cannulated screws. The rates of non-union and late collapse for each type were calculated. RESULTS: Sixteen patients were classified as Type A, 43 as Type B, and 6 as Type C. The non-union rates were 0% for Type A, 6.7% for Type B, and 50.0% for Type C. The late collapse rates were 0% for Type A, 4.4% for Type B, and 0% for Type C. CONCLUSION: PEICM precisely detected femoral head perfusion. Primary prosthetic replacement should be considered for older patients with Type C to minimize the chances of revision surgery, even in undisplaced femoral neck fractures.


Assuntos
Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas , Imageamento por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Cabeça do Fêmur/irrigação sanguínea , Cabeça do Fêmur/diagnóstico por imagem , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Falha de Tratamento
20.
Am J Emerg Med ; 35(9): 1314-1316, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28412162

RESUMO

INTRODUCTION: A sacral insufficiency fracture (SIF) often manifests as low back pain or sciatica in the absence of any antecedent trauma. These fractures may be missed because of lack of appropriate imaging. The purpose of this study was to clarify the incidence and clinical features of SIF as well as the characteristic findings on magnetic resonance imaging (MRI) of the lumbar spine. MATERIALS AND METHODS: The study participants comprised 250 patients (132 male, 118 female; mean age 58.6years) with pelvic trauma. SIF was identified on computed tomography or MRI. The incidence, initial symptoms, and time delay between the first visit and an accurate diagnosis of SIF were recorded. RESULTS: We detected 11 cases of SIF. Initial symptoms of SIF were low back pain (36.4%), gluteal pain (63.6%), and coxalgia (18.2%). Two patients complained of both low back pain and gluteal pain. The mean delay between the first visit and an accurate diagnosis of SIF was 23.9days. This time interval was significantly longer than in patients with other types of pelvic fracture. Four patients underwent MRI targeting the lumbar spine to investigate their symptoms. In all 4 patients, the signal intensity on T1-weighted and fat-suppressed images of the second sacral segment was low and high, respectively. CONCLUSION: This study demonstrates that accurate diagnosis of SIF may be delayed because of difficulties in detecting this type of fracture on plain X-ray and the non-specific nature of the presenting complaints. Emergency physicians should keep SIF in mind when investigating patients who complain of low back pain or gluteal pain. Findings at the second sacral segment on MRI targeting the lumbar spine may aid early diagnosis of this type of pelvic fracture.


Assuntos
Diagnóstico Tardio , Fraturas de Estresse/diagnóstico por imagem , Vértebras Lombares/lesões , Sacro/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Humanos , Japão , Dor Lombar/etiologia , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Osteoporose/complicações , Estudos Retrospectivos , Sacro/diagnóstico por imagem , Tomografia Computadorizada por Raios X