Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 13(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38256659

RESUMO

Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical implantation and its implementation is progressively increasing worldwide. We routinely perform pre-procedural aortic angiography CT to assess aortic dimensions and vascular anatomy. This study aims to evaluate the image quality of CTA for TAVI planning using dual-layer spectral CT, with virtual monoenergetic image reconstructions at 40 keV. Thirty-one patients underwent a CTA protocol with the injection of 20 mL of contrast media. Image quality was assessed by measuring the mean density in Hounsfield Units (HU), the signal-to-noise ratio, and the contrast-to-noise ratio in VMI reconstructions. Additionally, a blinded subjective analysis was conducted by two observers. The results showed significant enhancement at all sampled vascular levels with a gradual decrease in HU from proximal to distal regions. Favourable subjective ratings were given for all parameters, with greater variability in the evaluation of iliac axes. A significant negative correlation (p < 0.05) was observed between BMI and CA at all vascular levels, indicating reduced contrast enhancement with increasing BMI. Spectral CT, along with reducing iodine load, allows for obtaining high-quality images without a significant increase in noise. The reduction in iodine load can have positive implications in clinical practice, improving patient safety and resource efficiency.

2.
Heart Rhythm ; 9(8): 1280-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22516184

RESUMO

BACKGROUND: Currently, training in interventional electrophysiology is based on conventional methodologies, and a paucity of data on the usefulness of simulation in this field is available. OBJECTIVE: The purpose of this study was to evaluate the impact of simulator training on trainees' performance in electrophysiologic catheter placement during the early phase of their learning curve. METHODS: Inexperienced electrophysiology fellows were considered. A hybrid high-fidelity simulator (Procedicus VIST, version 7.0, Mentice AB Gothenburg, Sweden for Biosense Webster) was used. The following parameters were evaluated in 3 consecutive patient-based procedures before and after two training sessions of at least 1.5 hours on the simulator: (1) ability to place catheters in conventional recording/pacing sites (coronary sinus, His-bundle area, high right atrium, and right ventricular apex); (2) amount of help provided by the supervisor (scale from 1-3; 3 for maximal help); (3) fluoroscopy time; and (4) positioning time. RESULTS: Seven fellows performed 168 catheter placements during 42 patient-based procedures with no complications. Comparing parameters before and after simulator training, there was a significant reduction in the mean amount of help and in fluoroscopy and positioning times per placement: from 1.71 ± 1.24 to 0.42 ± 0.68 (P <.001), from 121 ± 88 seconds to 76 ± 54 seconds (P <.001), and from 175 ± 138 seconds to 102 ± 74 seconds (P <.001), respectively. Overall fluoroscopy time per patient decreased from 567 ± 220 seconds to 305 ± 111 seconds (P <.0001). Improvement appeared to be related to simulator training alone and not to the previously performed patient-based procedures. CONCLUSION: During the early phase of the trainees' learning curve, simulator training significantly improves the independent trainees' performance with reduction in radiation exposure.


Assuntos
Eletrofisiologia Cardíaca/educação , Cateterismo , Competência Clínica , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional , Adulto , Simulação por Computador , Feminino , Fluoroscopia , Humanos , Curva de Aprendizado , Masculino , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA