Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Respir Res ; 25(1): 203, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730430

RESUMO

BACKGROUND: Although electronic nose (eNose) has been intensively investigated for diagnosing lung cancer, cross-site validation remains a major obstacle to be overcome and no studies have yet been performed. METHODS: Patients with lung cancer, as well as healthy control and diseased control groups, were prospectively recruited from two referral centers between 2019 and 2022. Deep learning models for detecting lung cancer with eNose breathprint were developed using training cohort from one site and then tested on cohort from the other site. Semi-Supervised Domain-Generalized (Semi-DG) Augmentation (SDA) and Noise-Shift Augmentation (NSA) methods with or without fine-tuning was applied to improve performance. RESULTS: In this study, 231 participants were enrolled, comprising a training/validation cohort of 168 individuals (90 with lung cancer, 16 healthy controls, and 62 diseased controls) and a test cohort of 63 individuals (28 with lung cancer, 10 healthy controls, and 25 diseased controls). The model has satisfactory results in the validation cohort from the same hospital while directly applying the trained model to the test cohort yielded suboptimal results (AUC, 0.61, 95% CI: 0.47─0.76). The performance improved after applying data augmentation methods in the training cohort (SDA, AUC: 0.89 [0.81─0.97]; NSA, AUC:0.90 [0.89─1.00]). Additionally, after applying fine-tuning methods, the performance further improved (SDA plus fine-tuning, AUC:0.95 [0.89─1.00]; NSA plus fine-tuning, AUC:0.95 [0.90─1.00]). CONCLUSION: Our study revealed that deep learning models developed for eNose breathprint can achieve cross-site validation with data augmentation and fine-tuning. Accordingly, eNose breathprints emerge as a convenient, non-invasive, and potentially generalizable solution for lung cancer detection. CLINICAL TRIAL REGISTRATION: This study is not a clinical trial and was therefore not registered.


Assuntos
Aprendizado Profundo , Nariz Eletrônico , Neoplasias Pulmonares , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Respiratórios/métodos , Neoplasias Pulmonares/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Science ; 384(6693): 325-332, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38669568

RESUMO

Artificial intelligence (AI) edge devices prefer employing high-capacity nonvolatile compute-in-memory (CIM) to achieve high energy efficiency and rapid wakeup-to-response with sufficient accuracy. Most previous works are based on either memristor-based CIMs, which suffer from accuracy loss and do not support training as a result of limited endurance, or digital static random-access memory (SRAM)-based CIMs, which suffer from large area requirements and volatile storage. We report an AI edge processor that uses a memristor-SRAM CIM-fusion scheme to simultaneously exploit the high accuracy of the digital SRAM CIM and the high energy-efficiency and storage density of the resistive random-access memory memristor CIM. This also enables adaptive local training to accommodate personalized characterization and user environment. The fusion processor achieved high CIM capacity, short wakeup-to-response latency (392 microseconds), high peak energy efficiency (77.64 teraoperations per second per watt), and robust accuracy (<0.5% accuracy loss). This work demonstrates that memristor technology has moved beyond in-lab development stages and now has manufacturability for AI edge processors.

3.
IEEE Trans Biomed Circuits Syst ; 17(5): 1097-1110, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37436854

RESUMO

This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 µVrms, and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 µm standard CMOS technology and consumes 4.5 µW while occupying 1.125 mm2.


Assuntos
Eletrocardiografia , Telemetria , Monitorização Fisiológica , Amplificadores Eletrônicos , Algoritmos , Tecnologia sem Fio , Processamento de Sinais Assistido por Computador , Desenho de Equipamento
5.
IEEE Trans Biomed Circuits Syst ; 17(2): 286-298, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37027648

RESUMO

Inspired by the human brain, spiking neuron networks are promising to realize energy-efficient and low-latency neuromorphic computing. However, even state-of-the-art silicon neurons are orders of magnitude worse than biological neurons in terms of area and power consumption due to the limitations. Moreover, limited routing in typical CMOS processes is another challenge for realizing the fully-parallel high-throughput synapse connections compared to biological synapses. This paper presents an SNN circuit that utilizes resource-sharing techniques to address the two challenges. Firstly, a comparator sharing neuron circuit with a background calibration technique is proposed to shrink the size of a single neuron without performance degradation. Secondly, a time-modulated axon-sharing synapse system is proposed to realize a fully-parallel connection with limited hardware overhead. To validate the proposed approaches, a CMOS neuron array is designed and fabricated under a 55-nm process. It consists of 48 LIF neurons with 3125 neurons/mm 2 area density, power consumption of 5.3 pJ/spike, and equivalent 2304 fully parallel synapses providing a unit throughput of 5500 events/s/neuron. It proves the proposed approaches are promising to realize a high-throughput high-efficiency SNN with CMOS technology.


Assuntos
Redes Neurais de Computação , Neurônios , Humanos , Calibragem , Neurônios/fisiologia , Axônios , Sinapses/fisiologia
6.
IEEE Trans Biomed Circuits Syst ; 16(6): 1075-1094, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36459601

RESUMO

Conventional electromagnetic (EM) sensing techniques such as radar and LiDAR are widely used for remote sensing, vehicle applications, weather monitoring, and clinical monitoring. Acoustic techniques such as sonar and ultrasound sensors are also used for consumer applications, such as ranging and in vivo medical/healthcare applications. It has been of long-term interest to doctors and clinical practitioners to realize continuous healthcare monitoring in hospitals and/or homes. Physiological and biopotential signals in real-time serve as important health indicators to predict and prevent serious illness. Emerging electromagnetic-acoustic (EMA) sensing techniques synergistically combine the merits of EM sensing with acoustic imaging to achieve comprehensive detection of physiological and biopotential signals. Further, EMA enables complementary fusion sensing for challenging healthcare settings, such as real-world long-term monitoring of treatment effects at home or in remote environments. This article reviews various examples of EMA sensing instruments, including implementation, performance, and application from the perspectives of circuits to systems. The novel and significant applications to healthcare are discussed. Three types of EMA sensors are presented: (1) Chip-based radar sensors for health status monitoring, (2) Thermo-acoustic sensing instruments for biomedical applications, and (3) Photoacoustic (PA) sensing and imaging systems, including dedicated reconstruction algorithms were reviewed from time-domain, frequency-domain, time-reversal, and model-based solutions. The future of EMA techniques for continuous healthcare with enhanced accuracy supported by artificial intelligence (AI) is also presented.


Assuntos
Inteligência Artificial , Tecnologia de Sensoriamento Remoto , Acústica , Fenômenos Eletromagnéticos , Atenção à Saúde
7.
Micromachines (Basel) ; 10(9)2019 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-31514357

RESUMO

Metal-oxide (MOX) gas sensors are widely used for gas concentration estimation and gas identification due to their low cost, high sensitivity, and stability. However, MOX sensors have low selectivity to different gases, which leads to the problem of classification for mixtures and pure gases. In this study, a square wave was applied as the heater waveform to generate a dynamic response on the sensor. The information of the dynamic response, which includes different characteristics for different gases due to temperature changes, enhanced the selectivity of the MOX sensor. Moreover, a polynomial interaction term mixture model with a dynamic response is proposed to predict the concentration of the binary mixtures and pure gases. The proposed method improved the classification accuracy to 100%. Moreover, the relative error of quantification decreased to 1.4% for pure gases and 13.0% for mixtures.

8.
Micromachines (Basel) ; 10(4)2019 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-31022928

RESUMO

The objective of this research was to develop a surface-acoustic-wave (SAW) sensor of cigarette smoke to prevent tobacco hazards and to detect cigarette smoke in real time through the adsorption of an ambient tobacco marker. The SAW sensor was coated with oxidized hollow mesoporous carbon nanospheres (O-HMC) as a sensing material of a new type, which replaced a polymer. O-HMC were fabricated using nitric acid to form carboxyl groups on carbon frameworks. The modified conditions of O-HMC were analyzed with Scanning Electron Microscopy (SEM), Fourier transform infrared spectrometry (FTIR), and X-ray diffraction (XRD). The appropriately modified O-HMC are more sensitive than polyacrylic acid and hollow mesoporous carbon nanospheres (PAA-HMC), which is proven by normalization. This increases the sensitivity of a standard tobacco marker (3-ethenylpyridine, 3-EP) from 37.8 to 51.2 Hz/ppm and prevents the drawbacks of a polymer-based sensing material. On filtering particles above 1 µm and using tar to prevent tar adhesion, the SAW sensor detects cigarette smoke with sufficient sensitivity and satisfactory repeatability. Tests, showing satisfactory selectivity to the cigarette smoke marker (3-EP) with interfering gases CH4, CO, and CO2, show that CO and CO2 have a negligible role during the detection of cigarette smoke.

9.
Sensors (Basel) ; 18(10)2018 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-30262785

RESUMO

Electronic nose (E-nose) systems have become popular in food and fruit quality evaluation because of their rapid and repeatable availability and robustness. In this paper, we propose an E-nose system that has potential as a non-destructive system for monitoring variation in the volatile organic compounds produced by fruit during the maturing process. In addition to the E-nose system, we also propose a camera system to monitor the peel color of fruit as another feature for identification. By incorporating E-nose and camera systems together, we propose a non-destructive solution for fruit maturity monitoring. The dual E-nose/camera system presents the best Fisher class separability measure and shows a perfect classification of the four maturity stages of a banana: Unripe, half-ripe, fully ripe, and overripe.

10.
Sensors (Basel) ; 16(11)2016 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-27792131

RESUMO

An electronic nose (E-Nose) is one of the applications for surface acoustic wave (SAW) sensors. In this paper, we present a low-noise complementary metal-oxide-semiconductor (CMOS) readout application-specific integrated circuit (ASIC) based on an SAW sensor array for achieving a miniature E-Nose. The center frequency of the SAW sensors was measured to be approximately 114 MHz. Because of interference between the sensors, we designed a low-noise CMOS frequency readout circuit to enable the SAW sensor to obtain frequency variation. The proposed circuit was fabricated in Taiwan Semiconductor Manufacturing Company (TSMC) 0.18 µm 1P6M CMOS process technology. The total chip size was nearly 1203 × 1203 µm². The chip was operated at a supply voltage of 1 V for a digital circuit and 1.8 V for an analog circuit. The least measurable difference between frequencies was 4 Hz. The detection limit of the system, when estimated using methanol and ethanol, was 0.1 ppm. Their linearity was in the range of 0.1 to 26,000 ppm. The power consumption levels of the analog and digital circuits were 1.742 mW and 761 µW, respectively.

11.
Biomicrofluidics ; 10(1): 011907, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26909119

RESUMO

Third-hand smoke (THS) is a new cigarette-related issue defined as the residual contamination from cigarette smoke after a cigarette is extinguished. To detect THS on three commonly used clothing fibers-wool, cotton, and polyester, we applied two methods to measure the adsorption of THS: one was the gain of mass with an analytical balance after exposure to cigarette smoke; and the other was to detect the THS chemical compounds such as nicotine and 3-ethenylpyridine with a surface acoustic wave (SAW) sensor composed of coated oxidized hollow mesoporous carbon nanospheres. In the mass measurement, the gain of mass decreased in the order wool, cotton, and polyester; the latter gain was about one tenth that of wool. In the SAW detection, the frequency shift decreased in the same order-wool, cotton, and polyester. The residence period of THS on natural fiber (wool and cotton) is greater than on synthetic polyester fiber. These two tests provide quantitative results of THS on varied clothing fibers, to assess their risk after exposure to cigarette smoke.

12.
IEEE Trans Biomed Circuits Syst ; 10(1): 98-112, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25838526

RESUMO

Although deep brain stimulation (DBS) has been a promising alternative for treating several neural disorders, the mechanisms underlying the DBS remain not fully understood. As rat models provide the advantage of recording and stimulating different disease-related regions simultaneously, this paper proposes a battery-less, implantable neuro-electronic interface suitable for studying DBS mechanisms with a freely-moving rat. The neuro-electronic interface mainly consists of a microsystem able to interact with eight different brain regions bi-directionally and simultaneously. To minimize the size of the implant, the microsystem receives power and transmits data through a single coil. In addition, particular attention is paid to the capability of recording neural activities right after each stimulation, so as to acquire information on how stimulations modulate neural activities. The microsystem has been fabricated with the standard 0.18 µm CMOS technology. The chip area is 7.74 mm (2) , and the microsystem is able to operate with a single supply voltage of 1 V. The wireless interface allows a maximum power of 10 mW to be transmitted together with either uplink or downlink data at a rate of 2 Mbps or 100 kbps, respectively. The input referred noise of recording amplifiers is 1.16 µVrms, and the stimulation voltage is tunable from 1.5 V to 4.5 V with 5-bit resolution. After the electrical functionality of the microsystem is tested, the capability of the microsystem to interface with rat brain is further examined and compared with conventional instruments. All experimental results are presented and discussed in this paper.


Assuntos
Encéfalo/fisiologia , Estimulação Encefálica Profunda/instrumentação , Eletrodos Implantados , Animais , Desenho de Equipamento , Ratos , Tecnologia sem Fio
13.
IEEE Trans Biomed Circuits Syst ; 10(2): 435-44, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26285218

RESUMO

This paper presents a capacitorless low-dropout (LDO) regulator with fast transient response and data reverse telemetry circuit for fully implantable wireless transmission applications. We propose a novel hybrid feedback structure using high-frequency compensation technology to achieve a rapid transient response for the LDO regulator. To reduce the size of the implant and transmit neural recordings through the same coil without interfering with power transmission, the load-shift-key (LSK) modulation technique is adopted for back data telemetry. The proposed implantable chip, fabricated using commercial 0.18 µm complementary metal oxide semiconductor technology, yielded an output power of 15 mW. Under 1.15 V operation voltage, the maximum overshoot and undershoot voltages were less than 45 mV and 55 mV, respectively, for a 15 mA full-load current whose rising and falling time were less than 100 ns. The proposed LSK transceiver uses a digitized demodulator to improve bandwidth efficiency for low carrier frequency operation.


Assuntos
Próteses e Implantes , Telemetria/instrumentação , Tecnologia sem Fio/instrumentação , Fontes de Energia Elétrica , Desenho de Equipamento , Humanos , Processamento de Sinais Assistido por Computador
14.
Sensors (Basel) ; 15(3): 5390-401, 2015 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-25751078

RESUMO

In this paper, we propose a bio-inspired, two-layer, multiple-walled carbon nanotube (MWCNT)-polypeptide composite sensing device. The MWCNT serves as a responsive and conductive layer, and the nonselective polypeptide (40 mer) coating the top of the MWCNT acts as a filter into which small molecular gases pass. Instead of using selective peptides to sense specific odorants, we propose using nonselective, peptide-based sensors to monitor various types of volatile organic compounds. In this study, depending on gas interaction and molecular sizes, the randomly selected polypeptide enabled the recognition of certain polar volatile chemical vapors, such as amines, and the improved discernment of low-concentration gases. The results of our investigation demonstrated that the polypeptide-coated sensors can detect ammonia at a level of several hundred ppm and barely responded to triethylamine.


Assuntos
Amônia/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Gases/isolamento & purificação , Compostos Orgânicos Voláteis/isolamento & purificação , Amônia/química , Gases/química , Nanotubos de Carbono/química , Peptídeos/química , Compostos Orgânicos Voláteis/química
15.
Anal Bioanal Chem ; 406(16): 3985-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24385138

RESUMO

This article introduces a power-efficient, miniature electronic nose (e-nose) system. The e-nose system primarily comprises two self-developed chips, a multiple-walled carbon nanotube (MWNT)-polymer based microsensor array, and a low-power signal-processing chip. The microsensor array was fabricated on a silicon wafer by using standard photolithography technology. The microsensor array comprised eight interdigitated electrodes surrounded by SU-8 "walls," which restrained the material-solvent liquid in a defined area of 650 × 760 µm(2). To achieve a reliable sensor-manufacturing process, we used a two-layer deposition method, coating the MWNTs and polymer film as the first and second layers, respectively. The low-power signal-processing chip included array data acquisition circuits and a signal-processing core. The MWNT-polymer microsensor array can directly connect with array data acquisition circuits, which comprise sensor interface circuitry and an analog-to-digital converter; the signal-processing core consists of memory and a microprocessor. The core executes the program, classifying the odor data received from the array data acquisition circuits. The low-power signal-processing chip was designed and fabricated using the Taiwan Semiconductor Manufacturing Company 0.18-µm 1P6M standard complementary metal oxide semiconductor process. The chip consumes only 1.05 mW of power at supply voltages of 1 and 1.8 V for the array data acquisition circuits and the signal-processing core, respectively. The miniature e-nose system, which used a microsensor array, a low-power signal-processing chip, and an embedded k-nearest-neighbor-based pattern recognition algorithm, was developed as a prototype that successfully recognized the complex odors of tincture, sorghum wine, sake, whisky, and vodka.


Assuntos
Nariz Eletrônico , Nanotubos de Carbono/química , Odorantes/análise , Vinho/análise , Algoritmos , Desenho de Equipamento , Polímeros/química , Semicondutores , Software
16.
IEEE Trans Biomed Circuits Syst ; 8(6): 765-78, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25576573

RESUMO

Ventilator-associated pneumonia (VAP) still lacks a rapid diagnostic strategy. This study proposes installing a nose-on-a-chip at the proximal end of an expiratory circuit of a ventilator to monitor and to detect metabolite of pneumonia in the early stage. The nose-on-a-chip was designed and fabricated in a 90-nm 1P9M CMOS technology in order to downsize the gas detection system. The chip has eight on-chip sensors, an adaptive interface, a successive approximation analog-to-digital converter (SAR ADC), a learning kernel of continuous restricted Boltzmann machine (CRBM), and a RISC-core with low-voltage SRAM. The functionality of VAP identification was verified using clinical data. In total, 76 samples infected with pneumonia (19 Klebsiella, 25 Pseudomonas aeruginosa, 16 Staphylococcus aureus, and 16 Candida) and 41 uninfected samples were collected as the experimental group and the control group, respectively. The results revealed a very high VAP identification rate at 94.06% for identifying healthy and infected patients. A 100% accuracy to identify the microorganisms of Klebsiella, Pseudomonas aeruginosa, Staphylococcus aureus, and Candida from VAP infected patients was achieved. This chip only consumes 1.27 mW at a 0.5 V supply voltage. This work provides a promising solution for the long-term unresolved rapid VAP diagnostic problem.


Assuntos
Candidíase/diagnóstico , Nariz Eletrônico , Pneumonia Bacteriana/diagnóstico , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Candidíase/metabolismo , Humanos , Pneumonia Bacteriana/metabolismo , Pneumonia Associada à Ventilação Mecânica/metabolismo
17.
Sensors (Basel) ; 13(10): 14214-47, 2013 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-24152879

RESUMO

Electronic noses have potential applications in daily life, but are restricted by their bulky size and high price. This review focuses on the use of chemiresistive gas sensors, metal-oxide semiconductor gas sensors and conductive polymer gas sensors in an electronic nose for system integration to reduce size and cost. The review covers the system design considerations and the complementary metal-oxide-semiconductor integrated technology for a chemiresistive gas sensor electronic nose, including the integrated sensor array, its readout interface, and pattern recognition hardware. In addition, the state-of-the-art technology integrated in the electronic nose is also presented, such as the sensing front-end chip, electronic nose signal processing chip, and the electronic nose system-on-chip.


Assuntos
Condutometria/instrumentação , Nariz Eletrônico , Eletrônica/instrumentação , Gases/análise , Gases/química , Transdutores , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Integração de Sistemas
18.
Artigo em Inglês | MEDLINE | ID: mdl-24110077

RESUMO

This article presents a novel AC to DC converter implemented by standard CMOS technology, applied for wireless power transmission. This circuit combines the functions of the rectifier and DC to DC converter, rather than using the rectifier to convert AC to DC and then supplying the required voltage with regulator as in the transitional method. This modification can reduce the power consumption and the area of the circuit. This circuit also transfers the loading condition back to the external circuit by the load shift keying(LSK), determining if the input power is not enough or excessive, which increases the efficiency of the total system. The AC to DC converter is fabricated with the TSMC 90nm CMOS process. The circuit area is 0.071mm(2). The circuit can produce a 1V DC voltage with maximum output current of 10mA from an AC input ranging from 1.5V to 2V, at 1MHz to 10MHz.


Assuntos
Fontes de Energia Elétrica , Próteses e Implantes , Conversão Análogo-Digital , Computadores , Eletricidade , Desenho de Equipamento , Retroalimentação , Processamento de Sinais Assistido por Computador , Software , Interface Usuário-Computador , Tecnologia sem Fio
19.
Artigo em Inglês | MEDLINE | ID: mdl-24110111

RESUMO

This paper presents the design and implementation of a low-power delta-sigma modulator for biomedical application with a standard 90 nm CMOS technology. The delta-sigma architecture is implemented as 2nd order feedforward architecture. A low quiescent current operational transconductance amplifier (OTA) is utilized to reduce power consumption. This delta-sigma modulator operated in 1V power supply, and achieved 64.87 dB signal to noise distortion ratio (SNDR) at 10 KHz bandwidth with an oversampling ratio (OSR) of 64. The power consumption is 17.14 µW, and the figure-of-merit (FOM) is 0.60 pJ/conv.


Assuntos
Tecnologia Biomédica/instrumentação , Desenho de Equipamento/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Amplificadores Eletrônicos , Fontes de Energia Elétrica , Razão Sinal-Ruído
20.
Artigo em Inglês | MEDLINE | ID: mdl-24110112

RESUMO

The initial resistance of chemiresistive gas sensors could be affected by temperature, humidity, and background odors. In a sensing system, the traditional interface circuit always requires an ADC to convert analog signal to digital signal. In this paper, we propose an ADC-free adaptive interface circuit for a resistive gas sensor to read sensor signal and cancel the baseline drift. Furthermore, methanol was used to test the proposed interface circuit, which was connected with a FIGARO® gas sensor. This circuit was fabricated by TSMC 0.18 µm CMOS process, and consumed 86.41 µW under 1 V supply voltage.


Assuntos
Técnicas Biossensoriais/instrumentação , Nariz Eletrônico , Humanos , Umidade , Temperatura , Transdutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA