1.
J Nucl Cardiol ; 25(6): 1948-1957, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-28353213

RESUMO

OBJECTIVES: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. METHODS: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. RESULTS: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. CONCLUSIONS: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Eletrocardiografia , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Reprodutibilidade dos Testes
2.
J Nucl Cardiol ; 25(6): 2029-2038, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-28608184

RESUMO

BACKGROUND: The U-shaped left ventricular (LV) contraction pattern, identified by MRI or echocardiography, is associated with improved CRT response. Gated SPECT MPI can measure both myocardial viability and mechanical dyssynchrony in a single scan. The aim of this study is to examine the relationship of the LV contraction pattern and the response of CRT in patients with left bundle branch block (LBBB). METHODS: Fifty-eight patients who met CRT guidelines and who had pre-CRT MPI were enrolled. Myocardial segments with tracer uptake < 50% of maximum were considered as scar. The LV contraction pattern was considered as U-shaped or non-U-shaped (U-shaped has a block line in the direction of contraction propagation). CRT response was defined as an increase in left ventricular ejection fraction ≥ 5% after 6-month follow-up. RESULTS: Twenty-eight patients (48%) had a U-shaped contraction pattern and thirty patients (52%) had a non-U-shaped contraction pattern. The U-shaped group showed a significantly higher response rate than the non-U-shaped group (90% vs. 57%; P = 0.005). By univariate and multivariate logistic regression analysis, the U-shaped pattern was an independent predictor of CRT response. CONCLUSION: Non-invasive gated SPECT MPI can characterize LV mechanical contraction patterns. A U-shaped contraction pattern identified is associated with improved CRT response. This may prove useful for improved patient selection for CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Contração Miocárdica , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade