Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Anal Chim Acta ; 1325: 343135, 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39244297

RESUMO

BACKGROUND: Mass spectrometry (MS)-based proteomics is a powerful tool for identifying and quantifying proteins. However, chimeric spectra caused by the fragmentation of multiple precursors within the same isolation window impair the accuracy of peptide identification and isobaric mass tag-based quantification. While there have been advances in computational deconvolution of chimeric spectra and methods to further separate the peptides by ion mobility or through MSn, the use of narrower isolation windows to decrease the fraction of chimeric species remains to be fully explored. RESULTS: We present results obtained on a SCIEX TripleTOF instrument where the quadrupole was optimized and tuned for precursor isolation at 0.1 Da (FWHH). Using a three-proteome model (trypsin digest of protein lysates from yeast, human and E. coli) and 8-plex iTRAQ labeling to document the interference effect, we investigated the impact of co-fragmentation on spectral purity, identification accuracy and quantification accuracy. The narrow quadrupole isolation window significantly improved the spectral purity and reduced the interference of non-target precursors on quantification accuracy. The high-resolution isolation strategy also reduced the number of false identifications caused by chimeric spectra. While these improvements came at the cost of sensitivity loss, combining high-resolution isolation with other advanced techniques, including ion mobility, may result in improved accuracy in identification and quantification. SIGNIFICANCE: Compared to standard-resolution quadrupole isolation (0.7 Da), high-resolution quadrupole isolation (0.1 Da) significantly improved the spectral purity and quantification accuracy while reducing the number of potential false identifications caused by chimeric spectra, thus showing excellent potential for further development to analyze clinical proteomics samples, for which high accuracy is essential.


Assuntos
Proteômica , Proteômica/métodos , Humanos , Íons/química , Escherichia coli/química , Saccharomyces cerevisiae/química , Peptídeos/química , Peptídeos/análise , Espectrometria de Massas/métodos
2.
Elife ; 112022 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-36449390

RESUMO

The possibility to record proteomes in high throughput and at high quality has opened new avenues for biomedical research, drug discovery, systems biology, and clinical translation. However, high-throughput proteomic experiments often require high sample amounts and can be less sensitive compared to conventional proteomic experiments. Here, we introduce and benchmark Zeno SWATH MS, a data-independent acquisition technique that employs a linear ion trap pulsing (Zeno trap pulsing) to increase the sensitivity in high-throughput proteomic experiments. We demonstrate that when combined with fast micro- or analytical flow-rate chromatography, Zeno SWATH MS increases protein identification with low sample amounts. For instance, using 20 min micro-flow-rate chromatography, Zeno SWATH MS identified more than 5000 proteins consistently, and with a coefficient of variation of 6%, from a 62.5 ng load of human cell line tryptic digest. Using 5 min analytical flow-rate chromatography (800 µl/min), Zeno SWATH MS identified 4907 proteins from a triplicate injection of 2 µg of a human cell lysate, or more than 3000 proteins from a 250 ng tryptic digest. Zeno SWATH MS hence facilitates sensitive high-throughput proteomic experiments with low sample amounts, mitigating the current bottlenecks of high-throughput proteomics.


Assuntos
Pesquisa Biomédica , Proteômica , Humanos , Proteoma , Biologia de Sistemas , Descoberta de Drogas
3.
J Proteome Res ; 21(7): 1686-1693, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35653712

RESUMO

Scanning SWATH coupled with normal-flow LC has been recently introduced for high-content, high-throughput proteomics analysis, which requires a relatively large amount of sample injection. Here we established the microflow LC coupled with Scanning SWATH for samples with relatively small quantities. First, we optimized several key parameters of the LC and MS settings, including C18 particle size for the analytical column, LC gradient and flow rate, as well as effective ion accumulation time and isolation window width for MS acquisition. We then compared the optimized Scanning SWATH method with the conventional variable window SWATH (referred to as SWATH) method. Results showed that the total ion chromatogram signals in Scanning SWATH were 10 times higher than that of SWATH, and Scanning SWATH identified 12.2-22.2% more peptides than SWATH. Finally, we employed 120 min Scanning SWATH to acquire the proteomes of 62 formalin-fixed, paraffin-embedded (FFPE) tissue samples from 31 patients with hepatocellular carcinoma (HCC). Altogether, 92 334 peptides and 8516 proteins were quantified. Besides the reported biomarkers, including ANXA2, MCM7, SUOX, and AKR1B10, we identified new potential HCC biomarkers such as CST5, TP53, CEBPB, and E2F4. Taken together, we present an optimal workflow integrating microflow LC and Scanning SWATH that effectively improves the protein identification and quantitation.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Biomarcadores , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Peptídeos , Proteômica/métodos
4.
Sci Data ; 9(1): 126, 2022 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-35354825

RESUMO

In the last decade, a revolution in liquid chromatography-mass spectrometry (LC-MS) based proteomics was unfolded with the introduction of dozens of novel instruments that incorporate additional data dimensions through innovative acquisition methodologies, in turn inspiring specialized data analysis pipelines. Simultaneously, a growing number of proteomics datasets have been made publicly available through data repositories such as ProteomeXchange, Zenodo and Skyline Panorama. However, developing algorithms to mine this data and assessing the performance on different platforms is currently hampered by the lack of a single benchmark experimental design. Therefore, we acquired a hybrid proteome mixture on different instrument platforms and in all currently available families of data acquisition. Here, we present a comprehensive Data-Dependent and Data-Independent Acquisition (DDA/DIA) dataset acquired using several of the most commonly used current day instrumental platforms. The dataset consists of over 700 LC-MS runs, including adequate replicates allowing robust statistics and covering over nearly 10 different data formats, including scanning quadrupole and ion mobility enabled acquisitions. Datasets are available via ProteomeXchange (PXD028735).


Assuntos
Benchmarking , Proteômica , Animais , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas/métodos , Proteoma
5.
Nat Biotechnol ; 39(7): 846-854, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33767396

RESUMO

Accurate quantification of the proteome remains challenging for large sample series and longitudinal experiments. We report a data-independent acquisition method, Scanning SWATH, that accelerates mass spectrometric (MS) duty cycles, yielding quantitative proteomes in combination with short gradients and high-flow (800 µl min-1) chromatography. Exploiting a continuous movement of the precursor isolation window to assign precursor masses to tandem mass spectrometry (MS/MS) fragment traces, Scanning SWATH increases precursor identifications by ~70% compared to conventional data-independent acquisition (DIA) methods on 0.5-5-min chromatographic gradients. We demonstrate the application of ultra-fast proteomics in drug mode-of-action screening and plasma proteomics. Scanning SWATH proteomes capture the mode of action of fungistatic azoles and statins. Moreover, we confirm 43 and identify 11 new plasma proteome biomarkers of COVID-19 severity, advancing patient classification and biomarker discovery. Thus, our results demonstrate a substantial acceleration and increased depth in fast proteomic experiments that facilitate proteomic drug screens and clinical studies.


Assuntos
Proteômica/métodos , Espectrometria de Massas em Tandem , Arabidopsis/metabolismo , Biomarcadores/metabolismo , COVID-19/sangue , COVID-19/diagnóstico , Linhagem Celular , Humanos , Peptídeos/análise , Proteoma/análise , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo , Índice de Gravidade de Doença
6.
Sci Data ; 7(1): 263, 2020 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-32782267

RESUMO

Sequential window acquisition of all theoretical fragment-ion spectra (SWATH) is a data-independent acquisition (DIA) strategy that requires a specific spectral library to generate unbiased and consistent quantitative data matrices of all peptides. SWATH-MS is a promising approach for in-depth proteomic profiling of Chinese hamster Ovary (CHO) cell lines, improving mechanistic understanding of process optimization, and real-time monitoring of process parameters in biologics R&D and manufacturing. However, no spectral library for CHO cells is publicly available. Here we present a comprehensive CHO global spectral library to measure the abundance of more than 10,000 proteins consisting of 199,102 identified peptides from a CHO-K1 cell proteome. The robustness, accuracy and consistency of the spectral library were validated for high confidence in protein identification and reproducible quantification in different CHO-derived cell lines, instrumental setups and downstream processing samples. The availability of a comprehensive SWATH CHO global spectral library will facilitate detailed characterization of upstream and downstream processes, as well as quality by design (QbD) in biomanufacturing. The data have been deposited to ProteomeXchange (PXD016047).


Assuntos
Proteoma/química , Animais , Células CHO , Cricetulus , Biblioteca Gênica , Proteômica
7.
Mol Omics ; 16(5): 436-447, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-32519713

RESUMO

We have developed MetaboKit, a comprehensive software package for compound identification and relative quantification in mass spectrometry-based untargeted metabolomics analysis. In data dependent acquisition (DDA) analysis, MetaboKit constructs a customized spectral library with compound identities from reference spectral libraries, adducts, dimers, in-source fragments (ISF), MS/MS fragmentation spectra, and more importantly the retention time information unique to the chromatography system used in the experiment. Using the customized library, the software performs targeted peak integration for precursor ions in DDA analysis and for precursor and product ions in data independent acquisition (DIA) analysis. With its stringent identification algorithm requiring matches by both MS and MS/MS data, MetaboKit provides identification results with significantly greater specificity than the competing software packages without loss in sensitivity. The proposed MS/MS-based screening of ISFs also reduces the chance of unverifiable identification of ISFs considerably. MetaboKit's quantification module produced peak area values highly correlated with known concentrations in a DIA analysis of the metabolite standards at both MS1 and MS2 levels. Moreover, the analysis of Cdk1Liv-/- mouse livers showed that MetaboKit can identify a wide range of lipid species and their ISFs, and quantitatively reconstitute the well-characterized fatty liver phenotype in these mice. In DIA data, the MS1-level and MS2-level peak area data produced similar fold change estimates in the differential abundance analysis, and the MS2-level peak area data allowed for quantitative comparisons in compounds whose precursor ion chromatogram was too noisy for peak integration.


Assuntos
Mineração de Dados , Metabolômica , Software , Animais , Fígado/metabolismo , Camundongos Knockout , Padrões de Referência , Espectrometria de Massas em Tandem
8.
Sci Rep ; 9(1): 15240, 2019 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-31645615

RESUMO

Advances in gene editing now allow reverse genetics to be applied to a broad range of biological systems. Ultimately, any modification to coding sequences requires confirmation at the protein level, although immunoblotting is often hampered by antibody quality or availability especially in non-model species. Sequential Window Acquisition of All Theoretical Spectra (SWATH), a mass spectrometry (MS) technology with exceptional quantitative reproducibility and accuracy, offers an ideal alternative for protein-based confirmation. Here, using genome edits in mouse, zebrafish and Bicyclus anynana butterflies produced using either homologous recombination or targeted nucleases, we demonstrate absence of the targeted proteins using SWATH, thus confirming successful editing. We show that SWATH is a robust antibody-independent alternative for monitoring gene editing at the protein level and broadly applicable across diverse organisms and targeted genome manipulation techniques. Moreover, SWATH concomitantly defines the global proteome response in the edited organism, which may provide pertinent biological insights.


Assuntos
Edição de Genes , Espectrometria de Massas/métodos , Proteínas/genética , Sequência de Aminoácidos , Animais , Borboletas , Edição de Genes/métodos , Recombinação Homóloga , Camundongos , Proteínas/análise , Proteoma/análise , Proteoma/genética , Proteômica/métodos , Peixe-Zebra
9.
J Proteome Res ; 17(12): 4051-4060, 2018 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-30270626

RESUMO

The 2017 Dagstuhl Seminar on Computational Proteomics provided an opportunity for a broad discussion on the current state and future directions of the generation and use of peptide tandem mass spectrometry spectral libraries. Their use in proteomics is growing slowly, but there are multiple challenges in the field that must be addressed to further increase the adoption of spectral libraries and related techniques. The primary bottlenecks are the paucity of high quality and comprehensive libraries and the general difficulty of adopting spectral library searching into existing workflows. There are several existing spectral library formats, but none captures a satisfactory level of metadata; therefore, a logical next improvement is to design a more advanced, Proteomics Standards Initiative-approved spectral library format that can encode all of the desired metadata. The group discussed a series of metadata requirements organized into three designations of completeness or quality, tentatively dubbed bronze, silver, and gold. The metadata can be organized at four different levels of granularity: at the collection (library) level, at the individual entry (peptide ion) level, at the peak (fragment ion) level, and at the peak annotation level. Strategies for encoding mass modifications in a consistent manner and the requirement for encoding high-quality and commonly seen but as-yet-unidentified spectra were discussed. The group also discussed related topics, including strategies for comparing two spectra, techniques for generating representative spectra for a library, approaches for selection of optimal signature ions for targeted workflows, and issues surrounding the merging of two or more libraries into one. We present here a review of this field and the challenges that the community must address in order to accelerate the adoption of spectral libraries in routine analysis of proteomics datasets.


Assuntos
Bases de Dados de Proteínas/normas , Biblioteca de Peptídeos , Proteômica/métodos , Animais , Humanos , Espectrometria de Massas em Tandem/métodos , Fluxo de Trabalho
10.
Nat Methods ; 14(9): 921-927, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28825704

RESUMO

Liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is the main method for high-throughput identification and quantification of peptides and inferred proteins. Within this field, data-independent acquisition (DIA) combined with peptide-centric scoring, as exemplified by the technique SWATH-MS, has emerged as a scalable method to achieve deep and consistent proteome coverage across large-scale data sets. We demonstrate that statistical concepts developed for discovery proteomics based on spectrum-centric scoring can be adapted to large-scale DIA experiments that have been analyzed with peptide-centric scoring strategies, and we provide guidance on their application. We show that optimal tradeoffs between sensitivity and specificity require careful considerations of the relationship between proteins in the samples and proteins represented in the spectral library. We propose the application of a global analyte constraint to prevent the accumulation of false positives across large-scale data sets. Furthermore, to increase the quality and reproducibility of published proteomic results, well-established confidence criteria should be reported for the detected peptide queries, peptides and inferred proteins.


Assuntos
Interpretação Estatística de Dados , Ensaios de Triagem em Larga Escala/métodos , Espectrometria de Massas/métodos , Mapeamento de Peptídeos/métodos , Proteínas/química , Análise de Sequência de Proteína/métodos , Simulação por Computador , Modelos Estatísticos , Proteínas/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA