Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

3.
Pharmacol Res ; 195: 106882, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37543096

RESUMO

Type 1 diabetes (T1D) is the most frequent form of diabetes in pediatric age, affecting more than 1.5 million people younger than age 20 years worldwide. Early and intensive control of diabetes provides continued protection against both microvascular and macrovascular complications, enhances growth, and ensures normal pubertal development. In the absence of definitive reversal therapy for this disease, achieving and maintaining the recommended glycemic targets is crucial. In the last 30 years, enormous progress has been made using technology to better treat T1D. In spite of this progress, the majority of children, adolescents and young adults do not reach the recommended targets for glycemic control and assume a considerable burden each day. The development of promising new therapeutic advances, such as more physiologic insulin analogues, pioneering diabetes technology including continuous glucose monitoring and closed loop systems as well as new adjuvant drugs, anticipate a new paradigm in T1D management over the next few years. This review presents insights into current management of T1D in youths.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto Jovem , Humanos , Adolescente , Criança , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Controle Glicêmico , Automonitorização da Glicemia , Glicemia , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
4.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
5.
Wien Klin Wochenschr ; 135(Suppl 1): 53-61, 2023 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-37101025

RESUMO

This Guideline represents the recommendations of the Austrian Diabetes Association (ÖDG) on the use of diabetes technology (insulin pump therapy; continuous glucose monitoring, CGM; hybrid closed-loop systems, HCL; diabetes apps) and access to these technological innovations for people with diabetes mellitus based on current scientific evidence.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glicemia , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Hipoglicemiantes/uso terapêutico
6.
JAMA Netw Open ; 6(2): e230077, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36808243

RESUMO

Importance: Continuous glucose monitoring (CGM) devices have demonstrated efficacy in adults and more recently in youths and older adults with type 1 diabetes. In adults with type 1 diabetes, the use of real-time CGM compared with intermittently scanned CGM was associated with improved glycemic control, but there are limited data available for youths. Objective: To assess real-world data on achievement of time in range clinical targets associated with different treatment modalities in youths with type 1 diabetes. Design, Setting, and Participants: This multinational cohort study included children, adolescents, and young adults younger than 21 years (hereinafter referred to collectively as youths) with type 1 diabetes for a duration of at least 6 months who provided CGM data between January 1, 2016, and December 31, 2021. Participants were enrolled from the international Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) registry. Data from 21 countries were included. Participants were divided into 4 treatment modalities: intermittently scanned CGM with or without insulin pump use and real-time CGM with or without insulin pump use. Exposures: Type 1 diabetes and the use of CGM with or without an insulin pump. Main Outcomes and Measures: Proportion of individuals in each treatment modality group achieving recommended CGM clinical targets. Results: Among the 5219 participants (2714 [52.0%] male; median age, 14.4 [IQR, 11.2-17.1] years), median duration of diabetes was 5.2 (IQR, 2.7-8.7) years and median hemoglobin A1c level was 7.4% (IQR, 6.8%-8.0%). Treatment modality was associated with the proportion of individuals achieving recommended clinical targets. Adjusted for sex, age, diabetes duration, and body mass index standard deviation score, the proportion achieving the recommended greater than 70% time in range target was highest with real-time CGM plus insulin pump use (36.2% [95% CI, 33.9%-38.4%]), followed by real-time CGM plus injection use (20.9% [95% CI, 18.0%-24.1%]), intermittently scanned CGM plus injection use (12.5% [95% CI, 10.7%-14.4%]), and intermittently scanned CGM plus insulin pump use (11.3% [95% CI, 9.2%-13.8%]) (P < .001). Similar trends were observed for less than 25% time above (real-time CGM plus insulin pump, 32.5% [95% CI, 30.4%-34.7%]; intermittently scanned CGM plus insulin pump, 12.8% [95% CI, 10.6%-15.4%]; P < .001) and less than 4% time below range target (real-time CGM plus insulin pump, 73.1% [95% CI, 71.1%-75.0%]; intermittently scanned CGM plus insulin pump, 47.6% [95% CI, 44.1%-51.1%]; P < .001). Adjusted time in range was highest among real-time CGM plus insulin pump users (64.7% [95% CI, 62.6%-66.7%]). Treatment modality was associated with the proportion of participants experiencing severe hypoglycemia and diabetic ketoacidosis events. Conclusions and Relevance: In this multinational cohort study of youths with type 1 diabetes, concurrent use of real-time CGM and an insulin pump was associated with increased probability of achieving recommended clinical targets and time in range target as well as lower probability of severe adverse events compared with other treatment modalities.


Assuntos
Diabetes Mellitus Tipo 1 , Insulinas , Adulto Jovem , Humanos , Masculino , Adolescente , Criança , Idoso , Feminino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Glicemia , Estudos de Coortes , Automonitorização da Glicemia , Insulinas/uso terapêutico
7.
Children (Basel) ; 9(12)2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36553394

RESUMO

Background: The aim of this study was to assess and compare the time in range (TIR) of children with type 1 diabetes (T1D) before and during a diabetes summer camp using different therapy modalities. Methods: A retrospective analysis of continuous glucose monitoring (CGM) data collected from 26 children with T1D (mean age: 11.0 ± 1.4 years; 62% female; 62% on insulin pump; Hb1Ac 7.3 ± 0.8% (56.3 ± 8.7 mmol/mol) before and during a 14-day summer camp. CGM methods: 50% intermittently scanned CGM (isCGM) and 50% real-time CGM (rtCGM). No child was using a hybrid closed loop system. Results: Mean TIR during camp was significantly higher than before camp ((67.0 ± 10.7%) vs. 58.2% ± 17.4%, p = 0.004). There was a significant reduction in time above range (TAR) (p = 0.001) and increase in time below range (TBR) (p < 0.001), Children using isCGM showed a more pronounced improvement in TIR during camp compared to rtCGM-users (p = 0.025). The increase in TIR strongly correlated with numbers of scans per day in isCGM-users (r = 0.751, p = 0.003). Compared to isCGM-users, rtCGM-users showed significantly less TBR. The TIR target was met by 30.8% of participants during camp. Conclusion: Glycemic control improved significantly during the camp. However, on average, the therapy goal (TIR > 70%) could not be achieved despite great professional effort.

8.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

10.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35837984

RESUMO

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Insulina/uso terapêutico , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Pais/psicologia
11.
Lancet Digit Health ; 4(4): e245-e255, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272971

RESUMO

BACKGROUND: Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. METHODS: In a multicentre, multinational, parallel randomised controlled trial, participants aged 6-18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0-10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. FINDINGS: Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference -3·5 mmol/mol (95% CI -6·5 to -0·5 [-0·32 percentage points, -0·59 to -0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26-53]), but consistently high with CamAPS FX (93% [88-96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. INTERPRETATION: The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Algoritmos , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino
12.
Pediatr Diabetes ; 23(3): 330-340, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35084795

RESUMO

OBJECTIVE: Continuous subcutaneous insulin infusion (CSII) in youths with type 1 diabetes (T1D) is often associated with lower HbA1c, lower total daily insulin dose (TDD), and lower body mass index (BMI) compared with multiple daily injections (MDI). Individual responses to CSII are diverse. The aim was to identify unique three-variate patterns of HbA1c, BMI standard deviation score (SDS), and TDD after switching to CSII. METHODS: Five thousand one hundred and thirty-three youths (≤20 years; 48% boys; median age at pump start 12.5 years) with T1D duration ≥3 years at CSII initiation were selected from the multicenter DPV registry. We applied group-based multitrajectory modeling to identify groups of individuals following similar trajectories. Measurements were aggregated quarterly during a 3-year follow-up period. Trajectory variables were changes of HbA1c, BMI-SDS, and TDD from baseline (delta = quarterly aggregated values at each time point [i] minus the respective baseline value). RESULTS: Four groups of diverging Delta-HbA1c, Delta-BMI-SDS, and Delta-TDD patterns were identified. All showed improvements in HbA1c during the first 3 months. Group 1 (12%) was characterized by modest HbA1c increase thereafter, TDD reduction, and stable BMI-SDS. In Group 2 (39%), increasing HbA1c, decreasing BMI-SDS, and stable TDD were found. By contrast, sustainably improved HbA1c, increasing BMI-SDS, and stable TDD were observed in Group 3 (32%). Group 4 (17%) was characterized by increasing levels for HbA1c, BMI-SDS, and TDD. Between-group differences in baseline HbA1c, BMI-SDS, TDD as well as in sex ratio, age at diabetes onset and at pump start were observed. CONCLUSIONS: Definite trajectories of glycemic control, BMI, and TDD over 3 years after CSII initiation were identified in youths with T1D allowing a more personalized treatment recommendation.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Índice de Massa Corporal , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemiantes/uso terapêutico , Insulina , Sistemas de Infusão de Insulina , Masculino
13.
N Engl J Med ; 386(3): 209-219, 2022 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-35045227

RESUMO

BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico/instrumentação , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Algoritmos , Glicemia/análise , Criança , Pré-Escolar , Estudos Cross-Over , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Humanos , Hiperglicemia/diagnóstico , Lactente , Masculino
14.
Diabetes Obes Metab ; 24 Suppl 1: 43-57, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34658126

RESUMO

Insulin pumps and glucose sensors are effective in improving diabetes therapy and reducing acute complications. The combination of both devices using an algorithm-driven interoperable controller makes automated insulin delivery (AID) systems possible. Many AID systems have been tested in clinical trials and have proven safety and effectiveness. However, currently, none of these systems are available for routine use in children younger than 6 years in Europe. For continued use, both users and prescribers must have sound knowledge of the features of the individual AID systems. Presently, all systems require various user interactions (e.g. meal announcements) because fully automated systems are not yet developed. Open-source systems are non-regulated variants to circumvent existing regulatory conditions. There are risks here for both users and prescribers. To evaluate AID therapy, the metric data of the glucose sensors, 'time in target range' and 'glucose management index', are novel recognized and suitable parameters allowing a consultation based on real glucose and insulin pump download data from the daily life of people with diabetes. Read out via cloud-based software or automatic download of such individual treatment data provides the ideal technical basis for shared decision-making through telemedicine, which must be further evaluated for general use.


Assuntos
Diabetes Mellitus , Pâncreas Artificial , Automonitorização da Glicemia , Criança , Diabetes Mellitus/terapia , Humanos , Sistemas de Infusão de Insulina
15.
Front Endocrinol (Lausanne) ; 12: 721028, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34456876

RESUMO

Background: Type 1 diabetes in young children is a heavy parental burden. As part of pilot phase of the KIDSAP01 study, we conducted a baseline assessment in parents to study the association between hypoglycemia fear, parental well-being and child behavior. Methods: All parents were invited to fill in baseline questionnaires: hypoglycemia fear survey (HFS), WHO-5, Epworth Sleepiness Scale and Strength and Difficulties Questionnaire (SDQ). Results: 24 children (median age: 5-year, range 1-7 years, 63% male, mean diabetes duration: 3 ± 1.7 years) participated. 23/24 parents filled out the questionnaires. We found a higher score for the hypoglycemia fear behavior 33.9 ± 5.6 compared to hypoglycemia worry 34.6 ± 12.2. Median WHO-5 score was 16 (8 - 22) with poor well-being in two parents. Median daytime sleepiness score was high in five parents (>10). For six children a high total behavioral difficulty score (>16) was reported. Pro social behavior score was lower than normal in six children (<6). Parental well-being was negatively associated with HFS total (r = - 0.50, p <.05) and subscale scores (r = - 0.44, p <.05 for HFS-Worry and HFS-Behavior), child behavior (r = - 0.45, p = .05) and positively with child age and diabetes duration (r = 0.58, p <.01, r = 0.6, p <.01). HFS, parental well-being nor daytime sleepiness are associated with the HbA1c. Conclusion: Regular screening of parental well-being, hypoglycemia fear and child behavior should be part of routine care to target early intervention.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Pais/psicologia , Adulto , Idade de Início , Ansiedade/epidemiologia , Ansiedade/psicologia , Criança , Comportamento Infantil/psicologia , Pré-Escolar , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Europa (Continente)/epidemiologia , Medo/psicologia , Feminino , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemia/psicologia , Lactente , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Masculino , Inquéritos e Questionários
16.
J Clin Med ; 10(11)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072900

RESUMO

The aim of this systematic review and meta-analysis was to compare time in range (TIR) (70-180 mg/dL (3.9-10.0 mmol/L)) between fully closed-loop systems (CLS) and standard of care (including hybrid systems) during physical exercise in people with type 1 diabetes (T1D). A systematic literature search was conducted in EMBASE, PubMed, Cochrane Central Register of Controlled Trials, and ISI Web of Science from January 1950 until January 2020. Randomized controlled trials including studies with different CLS were compared against standard of care in people with T1D. The meta-analysis was performed using the random effects model and restricted maximum likelihood estimation method. Six randomized controlled trials involving 153 participants with T1D of all age groups were included. Due to crossover test designs, studies were included repeatedly (a-d) if CLS or physical exercise interventions were different. Applying this methodology increased the comparisons to a total number of 266 participants. TIR was higher with an absolute mean difference (AMD) of 6.18%, 95% CI: 1.99 to 10.38% in favor of CLS. In a subgroup analysis, the AMD was 9.46%, 95% CI: 2.48% to 16.45% in children and adolescents while the AMD for adults was 1.07% 95% CI: -0.81% to 2.96% in favor of CLS. In this systematic review and meta-analysis CLS moderately improved TIR in comparison to standard of care during physical exercise in people with T1D. This effect was particularly pronounced for children and adolescents showing that the use of CLS improved TIR significantly compared to standard of care.

18.
BMJ Open ; 11(2): e042790, 2021 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-33579766

RESUMO

INTRODUCTION: Diabetes management in very young children remains challenging. Glycaemic targets are achieved at the expense of high parental diabetes management burden and frequent hypoglycaemia, impacting quality of life for the whole family. Our objective is to assess whether automated insulin delivery can improve glycaemic control and alleviate the burden of diabetes management in this particular age group. METHODS AND ANALYSIS: The study adopts an open-label, multinational, multicentre, randomised, crossover design and aims to randomise 72 children aged 1-7 years with type 1 diabetes on insulin pump therapy. Following screening, participants will receive training on study insulin pump and study continuous glucose monitoring devices. Participants will be randomised to 16-week use of the hybrid closed-loop system (intervention period) or to 16-week use of sensor-augmented pump therapy (control period) with 1-4 weeks washout period before crossing over to the other arm. The order of the two study periods will be random. The primary endpoint is the between-group difference in time spent in the target glucose range from 3.9 to 10.0 mmol/L based on sensor glucose readings during the 16-week study periods. Analyses will be conducted on an intention-to-treat basis. Key secondary endpoints are between group differences in time spent above and below target glucose range, glycated haemoglobin and average sensor glucose. Participants' and caregivers' experiences will be evaluated using questionnaires and qualitative interviews, and sleep quality will be assessed. A health economic analysis will be performed. ETHICS AND DISSEMINATION: Ethics approval has been obtained from Cambridge East Research Ethics Committee (UK), Ethics Committees of the University of Innsbruck, the University of Vienna and the University of Graz (Austria), Ethics Committee of the Medical Faculty of the University of Leipzig (Germany) and Comité National d'Ethique de Recherche (Luxembourg). The results will be disseminated by peer-reviewed publications and conference presentations. TRIAL REGISTRATION NUMBER: NCT03784027.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Áustria , Automonitorização da Glicemia , Criança , Pré-Escolar , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Lactente , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Luxemburgo , Estudos Multicêntricos como Assunto , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
19.
Diabetologia ; 63(12): 2501-2520, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33047169

RESUMO

Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (i.e. before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes. Graphical abstract.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Glicemia/metabolismo , Automonitorização da Glicemia , Exercício Físico/fisiologia , Humanos , Qualidade de Vida
20.
Pediatr Diabetes ; 21(8): 1375-1393, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33047481

RESUMO

Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (ie, before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Exercício Físico , Controle Glicêmico/métodos , Adolescente , Adulto , Glicemia , Criança , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA