Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 103(20): e38194, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758875

RESUMO

This study aimed to compare the postimplantation clinical outcomes of 2 types of posterior chamber phakic intraocular lenses (IOLs): Visian™ implantable collamer lenses (ICL; EVO+ V5; Staar Surgical, Monrovia, CA) and an implantable phakic contact lens (IPCL) (IPCL V2.0, Care Group Sight Solution, India) to correct high myopia and myopic astigmatism. This retrospective study included patients who had undergone phakic IOL implantation performed by a single surgeon between March 2021 and March 2022. Preoperative assessments included slit-lamp examination, fundus examination, spherical equivalent, uncorrected distant visual acuity (UDVA), corrected distant visual acuity (CDVA), specular microscope parameters, and optical quality analysis system parameters. Postoperative assessments after 1 year included slit-lamp examination to detect adverse effects and spherical equivalent, UDVA, CDVA, specular microscope, optical quality analysis system, and anterior-segment optical coherence tomography. Eighty eyes from 42 patients (47 eyes from 24 patients in the ICL group and 33 eyes from 18 patients in the IPCL group) were included. No statistically significant differences were observed between the 2 groups regarding preoperative parameters. At 1-year postoperatively, the mean UDVA in the ICL and IPCL groups was 0.019 ±â€…0.040 logMAR and 0.019 ±â€…0.041 logMAR, respectively. The mean CDVA was 0.001 ±â€…0.008 logMAR and 0.001 ±â€…0.007 logMAR in the ICL and IPCL groups, respectively, showing no statistically significant differences. The postoperative parameters did not differ significantly between the 2 groups. The visual acuity and refractive results of both groups were excellent, and both groups exhibited similar efficacy and safety profiles.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Fácicas , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Retrospectivos , Adulto , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Adulto Jovem , Astigmatismo/cirurgia , Miopia/cirurgia , Resultado do Tratamento
2.
Sci Rep ; 14(1): 9020, 2024 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641638

RESUMO

This study aimed to evaluate the changes in intraocular pressure (IOP) before and after femtosecond laser capsulorhexis and lens fragmentation for cataract surgery. We measured the IOP before, immediately, 30 min, and 1 h after the laser procedure in 47 eyes of 47 patients who underwent the femtosecond laser procedure. The mean IOP was 17.51 ± 3.28 mmHg, 30.23 ± 6.70 mmHg, 17.96 ± 3.75 mmHg, and 21.77 ± 5.88 mmHg before, immediately after, 30 min after, and 1 h after the laser procedure, respectively. The mean IOP significantly increased immediately (adjusted P < 0.001) and 1 h (adjusted P = 0.001) after the laser procedure compared with the pre-laser IOP. The mean IOP at 30 min after the laser procedure was significantly lower than that immediately after the procedure (adjusted P < 0.001). However, the IOP 1 h after the laser procedure became higher than that 30 min after the laser procedure. Additionally, the IOP 1 h after the laser procedure was positively correlated with the baseline IOP and negatively correlated with the axial length. In conclusion, this study demonstrated that cataract surgery should be commenced within 30 min after the femtosecond laser procedure to ensure a safe cataract surgery that reduces the risk of increased intraocular pressure.


Assuntos
Extração de Catarata , Catarata , Oftalmopatias , Terapia a Laser , Facoemulsificação , Humanos , Pressão Intraocular , Terapia a Laser/métodos , Extração de Catarata/métodos , Lasers
3.
Korean J Ophthalmol ; 38(2): 129-136, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38414249

RESUMO

PURPOSE: To assess long-term clinical results following bilateral Tecnis Symfony ZXR00 intraocular lens implantation with mini-monovision. METHODS: The medical records of cataract patients who underwent bilateral implantation of ZXR00 with intended mini-monovision (target refraction of -0.3 diopters [D] in dominant eye and -0.6 D in nondominant eye) between April 2019 and March 2021 were assessed. Postoperative uncorrected distance visual acuity (UDVA), corrected distance VA (CDVA), uncorrected intermediate VA (UIVA), uncorrected near VA (UNVA), and rate of spectacle dependence for near distance were investigated at 3 months and 2 years after surgery. RESULTS: This study included 61 patients (122 eyes) with average age of 61.8 ± 7.7 years. At 2 years postoperatively, binocular logarithm of the minimum angle of resolution UDVA, UIVA, UNVA, and CDVA were 0.086 ± 0.094, 0.056 ± 0.041, 0.140 ± 0.045, and 0.012 ± 0.024, respectively. The monocular manifest refraction spherical equivalent was -0.31 ± 0.38 in the dominant eye and -0.53 ± 0.47 in the nondominant eye at 3 months postoperatively, and -0.38 ± 0.43 in the dominant eye and -0.61 ± 0.54 in the nondominant eye at 2 years postoperatively. Eight out of 61 patients (13.1%) needed glasses 3 months after surgery, and nine out of 61 patients (14.8%) needed glasses 2 years after surgery. CONCLUSIONS: The bilateral implantation of ZXR00s with mini-monovision allows for a good VA at wide range of distance from far to near, thereby resulting in high rate of spectacle independence. These results have held up well even after 2 years after surgery.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Visão Monocular , Acuidade Visual , Refração Ocular , Desenho de Prótese , Satisfação do Paciente , Visão Binocular
4.
Int Ophthalmol ; 44(1): 54, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38341384

RESUMO

OBJECTIVE: To compare the visual performance of two presbyopia-correcting intraocular lenses (IOLs) that combine both bifocal and extended depth-of-focus profiles, Artis® Symbiose® Plus (Symbiose Plus; Cristalens Industrie, Lannion, France) and Tecnis® Synergy® (Synergy; Johnson & Johnson Vision, Santa Ana, CA, USA). METHODS: The medical records of patients with cataract bilaterally implanted with either Symbiose Plus or Synergy between January 2022 and January 2023 were assessed. The principal measures of postoperative findings included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near (40 and 33 cm) visual acuity (UNVA), objective optical quality (OOQ) parameters, distance-corrected defocus curve analysis, and surveys of subjective satisfaction. RESULTS: Total of 96 eyes from 48 patients were enrolled. Each group was equally composed of 24 patients, 48 eyes. There were no significant differences between the two groups on baseline characteristics. Both IOLs displayed excellent binocular UDVA, CDVA, and UNVA (40 and 33 cm) with no statistical difference (p = 0.467(UDVA), p = 0.584(CDVA), p = 0.096(40-cm UNVA), and p = 0.621(33-cm UNVA)). However, with regard to UIVA, the Synergy group showed significantly superior results (p < 0.001). In contrast, the Symbiose Plus group showed significantly better results on OOQ parameters and patient-reported quality of vision survey outcomes (both p < 0.001). CONCLUSIONS: Both IOLs provided a decent continuous range of vision from near to far distance.


Assuntos
Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Refração Ocular , Implante de Lente Intraocular/métodos , Presbiopia/cirurgia , Satisfação do Paciente , Desenho de Prótese , Visão Binocular
5.
Korean J Ophthalmol ; 38(1): 9-16, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38110185

RESUMO

PURPOSE: We aimed to compare the accuracy of the intraocular lens (IOL) calculation formula using the standard keratometry (K) and total K (TK) during the femtosecond laser-assisted cataract surgery (FLACS) with a monofocal IOL with enhanced intermediate function using currently used formulas. METHODS: A retrospective review of 125 eyes from 125 patients who had undergone FLACS with implantation of monofocal IOL with enhanced intermediate function was conducted. The predicted refractive power was calculated using an optical biometer (IOLmaster 700) according to the K and TK in the Barrett Universal II, SRK/T, Haigis, and Holladay 2 formulas. Absolute prediction error (APE) obtained from the actual postoperative refractive outcomes and the refractive error predicted in each formula was compared one month after surgery. RESULTS: Mean APE ranged between 0.29 and 0.39 diopters (D) regardless of the calculation formula and the method of measuring corneal curvature. Significant differences were observed in the APE from the four formulas and the two keratometric measurements (p = 0.014). In a total of 125 eyes from 125 patients, the mean APE was lowest with the Barrett Universal II formula. Across all formulas, both the mean APE and the median APE tended to be lower for K than for TK, although there was no significant difference. Approximately 70% to 80% of the patients were included within 0.5 D of the refractive error across all formulas. The percentage of eyes within 0.5 D of APE outcomes was not statistically different between the K and TK data when using each formula. CONCLUSIONS: Keratometric measurements considering the poster corneal curvature did not show any additional advantages when implanting the monofocal IOL with enhanced intermediate function during the FLACS.


Assuntos
Catarata , Hominidae , Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Animais , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Refração Ocular , Estudos Retrospectivos , Biometria/métodos , Lasers
6.
Front Med (Lausanne) ; 10: 1260298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38249986

RESUMO

Purpose: We evaluated the clinical outcomes after implantation of a new monofocal intraocular lens (IOL) with enhanced intermediate function in patients with preperimetric glaucoma and compared those with patients without retinal nerve fiber layer (RNFL) defects. Methods: All patients were implanted bilaterally a new monofocal IOL with enhanced intermediate function. Patients with bilateral RNFL defects and no glaucomatous visual field defects were classified as the preperimetric glaucoma group. A total of 60 eyes of 30 patients with preperimetric glaucoma were compared with 60 eyes of 30 patients without RNFL defects. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), defocus curve, contrast sensitivity, and questionnaire were evaluated 1 month and 3 months after surgery. Results: No difference in binocular UDVA, UIVA, and UNVA was evident between the two groups at 1 and 3 months postoperatively. Additionally, there were no significant differences between the two groups regarding the proportion of severe or very severe photic phenomena, such as glare and halos, or the overall satisfaction. Conclusion: Bilateral implantation of a new monofocal IOL with enhanced intermediate function in patients with preperimetric glaucoma demonstrated commensurate clinical outcomes and could be considered a feasible alternative.

7.
Front Med (Lausanne) ; 10: 1300778, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38269321

RESUMO

Purpose: We aimed to evaluate the effect of visit-to-visit variability in blood pressure (BP) on the risk of open-angle glaucoma (OAG) in individuals without systemic hypertension using a population-based retrospective cohort study design. Methods: The Korean National Health Insurance Service-National Health Screening Cohort database, which collected data of 209,226 individuals between 2002 and 2015, was used to analyze the data of 140,910 eligible participants. The mean follow-up duration was 8.3 years. Visit-to-visit BP variability was assessed using standard deviation (SD), coefficient of variation (CV), and variability independent of the mean (VIM). Participants were categorized into four groups according to BP variability quartiles. We verified the effect of BP variability by comparing participants of the first to third quartiles of BP variability groups with those belonging to the fourth quartile group. A Cox proportional hazards model was used to determine the hazard ratio (HR) of BP variability in cases of newly diagnosed OAG. Moreover, we conducted subgroup analyses using baseline characteristics. Results: In the multivariable analyses, BP variability did not significantly increase the risk of OAG development. However, subgroup analyses revealed significant interactions between age and systolic BP variability in the development of OAG (CV: p = 0.008; SD: p = 0.007). For participants aged <60 years, the risk of OAG development significantly increased with high systolic BP variability (CV: HR, 1.18; 95% confidence interval [CI], 1.00-1.39; p = 0.049). We observed a similar trend using the SD and VIM as the parameters for systolic BP variability. Conclusion: Higher visit-to-visit systolic BP variability was associated with an increased risk of OAG development in participants younger than 60 years of age without systemic hypertension. These results suggest that BP variability can be the considerable factor when assessing the risk of OAG, especially in relatively young people without systemic hypertension.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA