Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Endovasc Ther ; : 15266028241257106, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38818806

RESUMO

INTRODUCTION: Thoracic endovascular aortic repair (TEVAR) in chronic dissection is associated with a risk for distal stent-graft-induced new entry (dSINE) in up to a quarter of cases. We assess the mid-term outcome of a novel dissection-specific stent-graft (DSSG), which is a custom-made device based on the Cook Alpha platform, with a modified graft design and a distal endovascular elephant trunk without any supporting stent to reduce the radial force on the dissection membrane at the distal landing zone. METHODS: A retrospective single-center study of chronic dissection patients at high risk of dSINE who received an elective endovascular repair with DSSG from January 2017 to June 2023. The primary outcome is Kaplan-Meier (KM) estimated freedom from dSINE during follow-up. Secondary outcomes included technical success, aortic remodeling, and anatomical evaluation of the distal landing zone in cases with dSINE during follow-up versus those without. RESULTS: Thirty patients (24 males) with a median age of 66 years [range=31-78] underwent elective TEVAR with the DSSG. The majority, n=27 (90%), had previous aortic repair; 7 (23%) had established connective tissue disease, and 6 (20%) had established dSINE after previous stent-graft implantation as an indication for TEVAR. Technical success was achieved in n=29 (97%). Median follow-up was 38.5 months (4.3-76.4), and KM estimated freedom from dSINE at 1 and 3 years was 95.6% (SE 0.043) and 89% (SE 0.081), respectively Four cases developed dSINE during follow-up. The median distance from the distal stent-graft to the coeliac trunk was 74mm (range=18-123) in the dSINE group versus 26mm (range=0-74) in the non-dSINE group (p=0.049). Median proximal tangential aortic angulation in the distal landing zone was 38.5° (range=26°-50°) in the dSINE group compared to 21° (range=3-61°) in the non-dSINE group (p=0.052). CONCLUSIONS: The Use of a novel DSSG with low radial force for TEVAR in the setting of chronic dissection is safe and feasible, with remodeling outcomes comparable with standard TEVAR. The reduced distal radial force in the DSSG does not eliminate the risk for dSINE over time, with new entries occurring, particularly in cases where the distal landing zone is in a tortuous aortic segment and not close to the coeliac trunk. CLINICAL IMPACT: Using the novel dissection-specific stent-graft with reduced radial force is safe and feasible but does not completely eliminate the risk of dSINE occurring over time. The exact positioning of the distal stent-graft in a straight aortic segment, close to the coeliac trunk, may be of importance to further mitigate the risk.

2.
J Vasc Surg Cases Innov Tech ; 10(2): 101426, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38375347

RESUMO

In situ laser fenestration (ISLF) has emerged as a promising technique for emergent revascularization of the left subclavian artery in the case of thoracic endovascular aortic repair coverage, presenting excellent technical success rates in most studies. We describe a case of ISLF of the Thoraflex Hybrid frozen elephant trunk device to achieve immediate left subclavian artery revascularization. We demonstrate the feasibility and technical success of using ISLF in this setting, providing a less invasive alternative to conventional surgical revascularization when required.

3.
Eur J Vasc Endovasc Surg ; 66(3): 323-331, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37247689

RESUMO

OBJECTIVE: The significance of the inflammatory response in the natural course of acute type B aortic dissection (ATBAD) is unknown. The aim was to characterise inflammation and its transformation over time in ATBAD using 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) with contrast enhanced magnetic resonance imaging (MRI). METHODS: Ten patients underwent FDG-PET/MRI within two weeks of ATBAD (acute phase), three to four months (subacute phase), nine to 12 months (early chronic phase), and 21 to 24 months (late chronic phase) after ATBAD. Target background ratios (TBRs) were measured in the ascending aorta, aortic arch, and descending aorta. MRI inflammatory markers were assessed in the descending aorta. RESULTS: Ten patients were included: median age 69 years, median clinical follow up 32 months. In the acute phase there was increased FDG uptake in the descending aorta (maximum TBR 5.8, SD [standard deviation] 1.3) compared with the ascending aorta (TBR 3.3, SD 0.8, p < .010) and arch (TBR 4.2, SD 0.6, p = .010). The maximum TBR of the descending aorta decreased from the acute to subacute phase (TBR 3.5, SD 0.6, p = .010) and further to the early chronic phase (TBR 2.9, SD 0.4, p = .030) but was stable thereafter. The acute phase maximum TBR in the ascending aorta (TBR 3.3) and arch (TBR 4.2) decreased to the subacute phase (ascending: TBR 2.8, SD 0.6, p = .020; arch: TBR 2.7, SD 0.4, p = .010) and was stable thereafter. Four patients underwent surgical aortic repair (three for aortic dilatation at one, five, and 28 months and one for visceral ischaemia at three weeks). MRI signs of inflammation were present in all surgically treated patients vs. two of six of medically treated patients (p= .048). CONCLUSION: ATBAD is associated with increased FDG uptake in the acute phase primarily in the descending aorta, but also involving the aortic arch and ascending aorta, indicating an inflammatory response in the whole aorta. Inflammation subsides early in the ascending aorta and arch (three months), whereas it stabilised later in the descending aorta (nine to 12 months). MRI signs of inflammation were more frequent in patients who later needed surgical treatment and merit further investigation.


Assuntos
Dissecção Aórtica , Fluordesoxiglucose F18 , Humanos , Idoso , Dissecção Aórtica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Aorta Torácica , Imageamento por Ressonância Magnética , Inflamação/diagnóstico por imagem
4.
J Vasc Surg ; 77(6): 1815-1821, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36400361

RESUMO

OBJECTIVE: Pre-emptive embolization of aortic side branches may be effective in preventing type II endoleaks (T2EL) based on a previous systematic review and meta-analysis by our group. Data up to 2019 was, however, only based on retrospective studies. The aim of the current study was to update the meta-analysis and evaluate the current evidence on this treatment strategy. METHODS: A systematic literature search was performed with the same keywords and strategies used in the previous study. The complementary search included all articles published from January 1, 2019, through May 29, 2022. The incidence of aneurysm sac growth was the primary outcome of interest. RESULTS: Four new studies were identified, including one randomized controlled study and one nationwide registry-based retrospective study. Overall, the incidence of sac size enlargement was 4.3% in the embolization group compared with 6.8% in the control group (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.26-0.55), the incidence of T2EL was 19.7% vs 37.4% (OR, 0.38; 95% CI, 0.30-0.47), and the incidence of reintervention for T2EL was 1.2% vs 11.2% (OR, 0.12; 95% CI, 0.06-0.23). CONCLUSIONS: Current evidence confirms lower incidence of aneurysm sac growth, T2EL, and reinterventions when pre-emptive embolization of aortic side branches is performed in conjunction with endovascular aneurysm repair, compared with no embolization. However, a higher level of evidence is still required to support a broad change of practice, including data on cost-effectiveness and on the potential effect on rupture.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Humanos , Endoleak/epidemiologia , Endoleak/etiologia , Endoleak/prevenção & controle , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Embolização Terapêutica/efeitos adversos
5.
J Endovasc Ther ; : 15266028221121746, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36113080

RESUMO

PURPOSE: The aim of this study was to present a new technique for fenestrated endovascular aortic aneurysm repair (FEVAR) and to review its preliminary results. The SiMplified bARe-wire Target vessel (SMART) technique for FEVAR aims to simplify the procedure by avoiding guiding sheaths into visceral arteries during the main graft deployment. MATERIALS AND METHODS: The SMART technique requires a 12 to 16Fr contralateral introducer, depending on number of fenestrations-compared with standard 18 to 22Fr for 3 to 4 FEVAR-to achieve target vessel catheterization and stenting during FEVAR by avoiding the use of parallel 6 to 7Fr guiding sheaths into each visceral vessel. Fenestrations are sequentially catheterized, assisted by a steerable sheath. A Rosen wire is maintained in each fenestration, with a single sheath parked in the final target vessel while releasing the fenestrated graft. Data on patients treated for pararenal or thoracoabdominal aortic aneurysms with FEVAR, adopting the SMART technique, were retrospectively reviewed. End points were technical success, intraprocedural variables, 90-day mortality, major adverse events (MAEs), and target vessel patency. RESULTS: From May 2018 to December 2020, 57 consecutive patients were treated for pararenal or thoracoabdominal aortic aneurysms. Median total procedure time and total fluoroscopy time were 223 (196-271) minutes and 81 (71-94) minutes, respectively. Primary technical success was 96.4% (55/57). No misalignment occurred from graft deployment. The total number of fenestrations was 169, including 54 left and 53 right renal arteries, 43 superior mesenteric arteries and 18 celiac trunks (3.0±0.9 vessels/patient), with target vessel technical success of 98.2%. During the first 90 days, there were no deaths (0%). The MAEs included acute kidney injury (AKI) in 3 patients (5%) with no new dialysis onset, respiratory failure requiring prolonged ventilation in 2 patients (4%), myocardial ischemia in 1 patient (2%), but no lower limb ischemia, stroke, or spinal cord ischemia (SCI) occurred. After a mean follow-up of 14±10 months, there was 1 aortic-related death. Primary and assisted primary target vessel patency was 94.6%±1.8 and 97.0%±1.3% respectively. CONCLUSIONS: The SMART technique proved to be a safe alternative to standard FEVARs, with excellent technical result and acceptable target vessel patency at mid-term, while reducing the risk for introducer-induced lower limb ischemia, related complications, and morbidity. CLINICAL IMPACT: This study evalautes the outcome of fenestrated endovascular aortic repair (FEVAR) procedures at Uppsala university hospital using a simplified bare-wire Target vessel (SMART) technique. The SMART technique requires a smaller contralateral introducer compared to standard 18-22Fr for 3-4 FEVAR to achieve target vessel catetherization and stenting. Fifty-seven consecutive patients were treated for pararenal or thoracoabdominal aortic aneurysms. The SMART technique proved to be a safe alternative to standard FEVARs with excellent technical result and acceptable target vessel patency at mid-term, while reducing the risk for introducer-induced lower limb ischemia, related complications, and morbidity.

6.
Nucl Med Biol ; 106-107: 62-71, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35066391

RESUMO

INTRODUCTION: Neutrophils are part of the innate immune system and function as a first line of defense against invading microorganisms. Overactivity of the immune system may result in a devastating immuno-inflammation with extensive damage to tissue leading to organ damage and/or failure. The literature suggests several human diseases in which neutrophil elastase (NE) is postulated to be important in the pathophysiology including inflammatory bowel disease (IBD), chronic obstructive pulmonary disorder (COPD), abdominal aortic aneurysms (AAA), breast and lung cancer, and recently also in Sars-cov-2 virus infection (Covid-19). In particular, the lungs are affected by the destructive power of the protease neutrophil elastase (NE). In this paper, we report the pre-clinical development of a selective and specific positron emission tomography (PET) tracer, [11C]GW457427, as an in vivo biomarker for the study of NE, now available for human studies. METHODS: [11C]GW457427 was produced by methylation of GW447631 using [11C]methyl triflate and GMP validated production and quality control methods were developed. Chemical purity was high with no traces of the precursor GW611437 or other uv-absorbing compounds. A method for the determination of intact [11C]GW457427 in plasma was developed and the binding characteristics were evaluated in vitro and in vivo. An animal model for lung inflammation was used to investigate the specificity and sensitivity of the [11C]GW457427 tracer for neutrophil elastase (NE) in pulmonary inflammation, verified by blockade using two structurally different elastase inhibitors. RESULTS: [11C]GW457427 was obtained in approximately 45% radiochemical yield and with a radiochemical purity higher than 98%. Molar activity was in the range 130-360 GBq/µmol. Binding to NE was shown to be highly specific both in vitro and in vivo and a significantly higher uptake of tracer was found in a lipopolysaccharide mouse model of pulmonary inflammation compared with control animals. The uptake in lung tissue measured as standardized uptake value (SUV) strongly correlated with tissue NE content as measured by ELISA. In vitro studies also showed specific tracer binding in aortic tissue of patients with abdominal aorta aneurysm (AAA). The rate of metabolism in rats was appropriate considering the critical balance between available tracer for binding and requirement for blood clearance with about 40% and 20% intact [11C]GW457427 in plasma at 5 and 40 min, respectively. Radioactivity was cleared from blood and organs in control animals with mainly hepatobiliary excretion with distribution in the intestines and the urinary bladder; but without retention of the tracer in healthy organs of interests such as the lung, liver, kidneys or in the cardiovascular system. A dosimetry study in rat indicated that the whole-body effective dose was 2.2 µSv/MBq with bone marrow as the limiting organ. It is estimated that up to five PET-CT investigations could be performed in humans without exceeding a total dose of 10 mSv. CONCLUSION: [11C]GW457427 is a promising in vivo PET-biomarker for NE with high specific binding demonstrated both in vitro and in vivo. A GMP validated production method including quality control has been developed and a microdosing toxicity study performed with no adverse signs. [11C]GW457427 is currently being evaluated in a First-In-Man PET study.


Assuntos
COVID-19 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Animais , Humanos , Elastase de Leucócito , Camundongos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Ratos , SARS-CoV-2
7.
J Vasc Surg ; 75(2): 740-752.e1, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34634422

RESUMO

OBJECTIVE: We have summarized the available in situ laser fenestration (ISLF) literature, including experimental studies with their subsequent recommendations regarding the optimal fenestration technique and fabric, and the short- and mid-term results of clinical studies. METHODS: A systematic search for English-language reports was performed in MEDLINE, the Cochrane Database, and EMBASE in accordance with the PRISMA (preferred reporting items for systematic reviews and meta-analysis) guidelines by two investigators (C.F.P. and D.L.). The search period was from inception of the databases to August 31, 2020. The search terms included in situ, laser, fenestration, and endograft. A quality assessment of the studies was performed using the Newcastle-Ottawa scale by two other investigators (G.T. and A.W.) independently. RESULTS: A total of 19 clinical studies were included, with a total of 428 patients (390 cases of supra-aortic trunk ISLF, 38 cases of visceral vessel ISLF). The technical success rate was 96.9% and 95.6% for supra-aortic and visceral vessel ISLF, respectively. Most studies had reported <12 months of follow-up. The longest available follow-up was in one study at 5 years for left subclavian artery ISLF and 17 months for visceral vessel ISLF. Overall, the quality of the evaluated clinical studies was low. Six experimental studies were included, with the highest level of evidence suggesting fenestration of multifilament polyethylene terephthalate grafts, followed by dilation with either a 6- or 8-mm noncompliant balloon. CONCLUSIONS: The results from experimental studies favor the use of multifilament polyethylene terephthalate, followed by dilation with noncompliant balloons as the most durable in vitro technique for ISLF. The short-term outcomes for arch and visceral vessel revascularization have been promising, with low rates of in-hospital mortality, stroke, and end-organ ischemia. Nonetheless, the long-term durability of ISLF has not yet been determined, and ISLF should be limited to selected symptomatic and urgent cases.


Assuntos
Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Terapia a Laser/métodos , Complicações Pós-Operatórias/cirurgia , Humanos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Reoperação
8.
Ann Vasc Surg ; 81: 36-47, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34785340

RESUMO

BACKGROUND: The aim was to report short and mid-term outcomes of a novel, investigational, dissection-specific stent-graft (DSSG), specifically designed to address the features of chronic type B aortic dissection (CTBAD) and reduce the risk of distal stent-graft-induced new entry tears (dSINE). MATERIALS AND METHODS: A retrospective single center cohort study of all patients undergoing TEVAR with the DSSG for CTBAD from January 1, 2017 to January 31, 2020. The DSSG, which is a modified stent-graft based on the Cook Zenith Alpha Thoracic platform, has no proximal barbs, and a customized longer body length with substantial taper. The second and third distal Z-stents are sited internally to avoid any contact of the metal skeleton with the dissection membrane and have reduced radial force, while the most distal stent was removed creating a distal 30 mm unsupported Dacron graft. RESULTS: Sixteen patients (13 males, 3 females) with a median age of 66 years (range 31-79 years) underwent elective TEVAR of CTBAD using the DSSG. Six patients (38%) had an underlying connective tissue disorder. The median tapering was 10 mm (range 4 mm-21 mm) and median length 270 mm (range 210-380 mm). Technical success was achieved in all but one case (96%). One patient died within 30 days, due to retrograde type A dissection with cardiac tamponade. The 30-day rate of stroke, spinal cord ischemia, and re-interventions was 0%. After median imaging follow-up time of 17 months (range 1-31 months), one patient developed a dSINE 4 months after the index procedure. After median survival follow-up of 23 months (range 2-35 months), one late death occurred due to traumatic brain injury, while no aortic-related death occurred during follow-up. Complete false lumen (FL) thrombosis was achieved in 9 patients while the remaining 6 showed partial FL thrombosis. No instances of diameter increase at the level oftreated aortic segment were noted with serial measurements showing either stable (n = 7) or decreased (n = 8) maximal transverse diameter. CONCLUSIONS: Use of a novel DSSG with low radial force for TEVAR in the setting of CTBAD is safe and feasible. This early real-world experience shows promising mid-term effectiveness with low rates of dSINE or unplanned re-interventions and satisfactory aortic remodeling during follow-up. Longer follow-up is needed, however, before any firm conclusions can be drawn.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Adulto , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento
9.
Eur J Vasc Endovasc Surg ; 62(6): 859-868, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34716095

RESUMO

OBJECTIVE: To review experience of fenestrated-branched endovascular aortic repair (F-BEVAR) for pararenal/thoraco-abdominal aortic aneurysms (PRAA/TAAA) and to assess the association between pre-operative moderate to severe chronic kidney disease (CKD) and post-operative outcomes. METHODS: All consecutive patients undergoing (elective and non-elective) F-BEVAR at a single centre (1 January 2011 - 1 July 2019) were identified. Renal function was calculated as the estimated glomerular filtration rate (eGFR) using the Modification of Diet in Renal Disease formula. Accordingly, presence of moderate to severe CKD was defined as eGFR < 60 mL/min/1.73m2. RESULTS: Overall, 202 consecutive patients (mean age 72 ± 8 years; 25% women) underwent F-BEVAR for the treatment of PRAA/TAAA during the study period. Of these, 51 had a history of moderate to severe CKD (none on chronic haemodialysis). No statistically significant differences were found in demographics and major comorbidities between patients with or without a history of CKD. The overall peri-operative mortality rate was 2%, without statistically significant differences between study groups (p = .26). Patients with prior CKD had statistically significantly higher rates of acute kidney injury (AKI) (37% vs. 12%, p < .001). At three years, overall survival was statistically significantly lower in patients with history of CKD compared with those without pre-operative CKD (57% vs. 82%, p = .010). Similarly, freedom from renal function decline at three years was statistically significantly poorer in patients with prior history of CKD compared with those without pre-operative CKD (43% vs. 80%, p = .020). In a multivariable analysis CKD was independently associated with higher odds of peri-operative AKI (OR 2.8, 95% CI 1.9 - 5.8, p = .030), renal function decline (OR 4.9, 95% CI 1.7 - 9.2, p = .003), and all cause mortality (HR 3.2, 95% CI 1.2 - 8.6, p = .020). CONCLUSION: Despite low peri-operative mortality rates that are comparable to patients with unimpaired renal function, occurrence of AKI was statistically significantly higher in subjects with pre-existing moderate to severe CKD. History of CKD was independently associated to renal function decline and poorer midterm survival.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Taxa de Filtração Glomerular , Rim/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Progressão da Doença , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
10.
Ann Vasc Surg ; 72: 114-123, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33160054

RESUMO

BACKGROUND: This study aimed to examine outcomes after use of the native infrarenal aorta as distal landing zone for fenestrated-branched endovascular aortic repair (F-BEVAR) of pararenal-thoracoabdominal aortic aneurysms (PRAA-TAAA). METHODS: All F-BEVAR procedures for treatment of PRAA-TAAA (2011-2019) at 2 aortic centers were examined. The outcomes of interest were as follows: i) technical success, ii) perioperative morbidity, iii) preservation of lumbar arteries and the inferior mesenteric artery, iv) type IB endoleaks, v) reinterventions, vi) survival, vii) aneurysm sac behavior, and viii) infrarenal aortic changes. RESULTS: Twenty consecutive patients with distal landing in the native infrarenal aorta were included (median age 71 years; 25% men). The median number of visible lumbar arteries at baseline was 7, and a patent inferior mesenteric artery (IMA) before the operation was present in 19 (95%) of the cases. There were no deaths within 30 days. One patient (5%), operated on with a 4-BEVAR for a type 2 TAAA, experienced spinal cord ischemia (permanent paraplegia). The median decrease in the number of visible lumbar arteries at the first postoperative scan was 3 from the baseline value, whereas a patent IMA was preserved in 12 out of 19 patients. Only in one case (5%), a type IB endoleak was noted for an overall technical success rate of 95%, which required a standard EVAR 20 months after the initial operation. The median follow-up duration for the study cohort was 491 days; all patients were alive at the longest available individual follow-up, and no instances of new-onset type IB endoleaks were observed. Another 3 late reinterventions (in addition to the one mentioned previously) were performed during midterm follow-up, all because of target vessel instability. In patients with ≥12 months of follow-up after the index procedure (n = 12, 60% of the entire cohort), no instances of aneurysm sac increase >5 mm were noted; the median largest aortic diameter was 51 mm with a median difference from baseline of -6 mm. The median distal landing zone diameter increase was 4 mm from baseline but never beyond the nominal stent-graft diameter, whereas the median aortic bifurcation diameter differed 1 mm from baseline. CONCLUSIONS: This preliminary experience shows that the use of the native infrarenal aorta as a distal landing zone for F-BEVAR is safe in the short term and midterm in patients with suitable anatomy, allowing the sparing of collateral vessels. Longer follow-up is warranted to assess durability.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Dinamarca , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Paraplegia/etiologia , Desenho de Prótese , Estudos Retrospectivos , Isquemia do Cordão Espinal/etiologia , Suécia , Fatores de Tempo , Resultado do Tratamento
11.
J Vasc Surg ; 73(5): 1573-1582.e1, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33068767

RESUMO

OBJECTIVE: Chronic aortic dissection with aneurysm development that includes the aortic arch and/or thoracoabdominal aorta (TAAA) is traditionally treated with open or hybrid surgery. Total endovascular treatment with fenestrated and branched aortic repair (F/B-EVAR) has recently been introduced as a less invasive alternative. The aim was to report the short- and midterm outcomes from a single tertiary vascular center. METHODS: All patients with chronic aortic dissection treated with F/B-EVAR from 2010 to 2019 at Uppsala University Hospital were identified. Perioperative and postoperative parameters were analyzed, with focus on short- (<30 days) and midterm survival, complication, and reintervention rates. RESULTS: F/B-EVAR was performed on 26 patients (median age, 63 years; range, 33-87 years; 18 men; median aortic diameter, 70 mm; range, 50-98 mm); with a median follow-up of 23 months (range, 0.5-118.0 months). One patient underwent both arch and TAAA repair. Overall, 13 arch repairs (arch group) after type A (n = 8) and type B (n = 5) dissection (all elective) were performed, and 14 TAAA repairs (TAAA group) after type A (n = 5) and type B (n = 9) dissection (one rupture). A total of 72 aortic branches were targeted (22 arch, 50 TAAA). Short-term technical success was achieved in 24 of 27 procedures (89%). Failures were related to one intraoperative retrograde type A dissection (RTAD) requiring open conversion (arch group), one persistent type IC endoleak on completion angiography (arch group), and one persistent type III endoleak (TAAA group). Mortality was 4% (n = 1) at 30 days and related to a second RTAD that occurred after discharge and was found on autopsy. Both RTADs occurred in patients with chronic type B dissection undergoing fenestrated arch repair. Paraplegia occurred in three cases (two arch, one TAAA) (11%), none permanent, and stroke in three cases (one arch, one TAAA) (11%); one was permanent. In the midterm, endoleaks were detected in 12 patients (44%); persistent false lumen flow (n = 3), type IB (n = 1), type IC (n = 3), type II (n = 7), and type IIIC (n = 2). The 3-year survival (Kaplan-Meier) of the arch repair was 75% and for the TAAA, 93%. Freedom from reintervention at 3 years were 100% for arch repairs and 48% for TAAA. In patients with a follow-up of more than 6 months (n = 23), all had stable or decreased aortic diameters and complete false lumen thrombosis at the level of stent graft was present in 65% (n = 15). CONCLUSIONS: Endovascular treatment of postdissection aneurysms is feasible, with acceptable short-term and midterm outcomes. RTAD after fenestrated and branched endovascular arch repair warrants caution when performed on patients with native ascending aortas, and reinterventions are frequent in TAAA repair.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Doença Crônica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Suécia , Fatores de Tempo , Resultado do Tratamento
12.
N Engl J Med ; 383(26): 2538-2546, 2020 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-33296560

RESUMO

BACKGROUND: The results of a recent meta-analysis aroused concern about an increased risk of death associated with the use of paclitaxel-coated angioplasty balloons and stents in lower-limb endovascular interventions for symptomatic peripheral artery disease. METHODS: We conducted an unplanned interim analysis of data from a multicenter, randomized, open-label, registry-based clinical trial. At the time of the analysis, 2289 patients had been randomly assigned to treatment with drug-coated devices (the drug-coated-device group, 1149 patients) or treatment with uncoated devices (the uncoated-device group, 1140 patients). Randomization was stratified according to disease severity on the basis of whether patients had chronic limb-threatening ischemia (1480 patients) or intermittent claudication (809 patients). The single end point for this interim analysis was all-cause mortality. RESULTS: No patients were lost to follow-up. Paclitaxel was used as the coating agent for all the drug-coated devices. During a mean follow-up of 2.49 years, 574 patients died, including 293 patients (25.5%) in the drug-coated-device group and 281 patients (24.6%) in the uncoated-device group (hazard ratio, 1.06; 95% confidence interval, 0.92 to 1.22). At 1 year, all-cause mortality was 10.2% (117 patients) in the drug-coated-device group and 9.9% (113 patients) in the uncoated-device group. During the entire follow-up period, there was no significant difference in the incidence of death between the treatment groups among patients with chronic limb-threatening ischemia (33.4% [249 patients] in the drug-coated-device group and 33.1% [243 patients] in the uncoated-device group) or among those with intermittent claudication (10.9% [44 patients] and 9.4% [38 patients], respectively). CONCLUSIONS: In this randomized trial in which patients with peripheral artery disease received treatment with paclitaxel-coated or uncoated endovascular devices, the results of an unplanned interim analysis of all-cause mortality did not show a difference between the groups in the incidence of death during 1 to 4 years of follow-up. (Funded by the Swedish Research Council and others; ClinicalTrials.gov number, NCT02051088.).


Assuntos
Angioplastia com Balão , Stents Farmacológicos/efeitos adversos , Paclitaxel/administração & dosagem , Doença Arterial Periférica/terapia , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Feminino , Seguimentos , Humanos , Isquemia/terapia , Masculino , Paclitaxel/efeitos adversos , Doença Arterial Periférica/mortalidade , Modelos de Riscos Proporcionais , Stents/efeitos adversos
13.
J Vasc Surg ; 72(5): 1783-1792.e1, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32442608

RESUMO

OBJECTIVE: Type II endoleaks are the most common type of endoleak after endovascular aneurysm repair (EVAR) and may cause late sac expansion and rupture. To prevent this, prophylactic embolization of aortic side branches has been suggested. The aim of this review was to assess the current evidence for this prophylactic treatment and its association with sac size enlargement as well as rate of and reintervention for type II endoleak. METHODS: This was a systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The MEDLINE and Scopus databases were used to search for related articles until March 2019. After screening, original studies reporting outcome comparing patients having prophylactic embolization with those undergoing EVAR without prophylactic embolization were included. An assessment of the quality of the included studies as well as data extraction was performed by two independent observers. Statistical analysis was performed using Review Manager 5.3 (The Nordic Cochrane Center, Copenhagen, Denmark). RESULTS: There were 3777 publications identified. After elimination of duplicate entries and review of titles and abstracts, 13 retrospective cohort studies including 1427 patients comparing prophylactic embolization with standard EVAR therapy were identified. No randomized trials were available. Five of these 13 studies reported sac growth, with a frequency of 7.4% (14/90) in the embolization group vs 13.4% in controls (odds ratio [OR], 0.54; 95% confidence interval [CI], 0.29-1). The rate of type II endoleak was 18.5% (100/540) in the embolization group vs 38.6% in the control group (342/887; OR, 0.34; 95% CI, 0.26-0.44). Based on 10 studies, the rate of reintervention was 1.5% (7/468) in the embolization group vs 12.4% (80/646) in the control group (OR, 0.12; 95% CI, 0.06-0.24). Nine of these 13 studies showed that technical success of inferior mesenteric artery and lumbar artery embolization was 82.3% and 69.1%, respectively. Regarding complications, 10 of 108 patients (9.3%) in one study reported nonspecific abdominal pain after embolization, and all resolved with overnight rehydration. Only one patient, who previously had right hemicolectomy, died after inferior mesenteric artery embolization of ischemic colitis. CONCLUSIONS: This systematic review and meta-analysis suggests that prophylactic aortic side branch embolization may be associated with lower rate of sac enlargement, incidence of type II endoleaks, and reinterventions. However, high-quality unbiased studies are lacking in this field, and this review and meta-analysis may be affected by selection bias and residual confounders remaining in the retrospective studies. To conclude whether prophylactic embolization should be routinely performed, a prospective, randomized trial is required.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Embolização Terapêutica , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Endoleak/etiologia , Humanos
14.
Eur J Vasc Endovasc Surg ; 59(3): 464-471, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31708339

RESUMO

OBJECTIVE: This study aimed to evaluate the feasibility of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) combined with contrast enhanced magnetic resonance imaging (MRI) to identify inflammation in asymptomatic abdominal aortic aneurysms (AAA). METHODS: FDG PET/MRI was performed on 15 patients with asymptomatic infrarenal AAAs >45 mm diameter. Prevalence of FDG uptake and MRI findings of inflammatory changes (oedema, wall thickening, and late gadolinium enhancement [LGE]) in the aortic wall were investigated at three levels: suprarenal aorta; non-aneurysmal aortic neck; and AAA. RESULTS: The median diameter of the AAAs was 54 mm (range 47-65 mm) and the median expansion rate in the last 12 months was 3 mm (range 1-13 mm). The standard uptake value (SUV) of FDG in the aneurysmal wall (SUVmax 2.5) was higher than the blood pool (SUVmax 1.0; p < .001). The maximum target to background ratio was higher in the suprarenal aorta (mean ± SD; 3.1 ± 0.6) and aortic neck (2.7 ± 0.5) than in the aneurysmal aorta (2.5 ± 0.5; p < .001). Thirty-six FDG hotspots were observed in the aneurysmal wall of 13 patients. Wall thickening and LGE were identified in eight patients. The number of FDG hotspots correlated with recent AAA growth (r = 0.62, p = .01). The recent aneurysm expansion rate was higher in aneurysms with LGE than in those without (7 mm vs. 2 mm; p = .03). MRI inflammatory changes were observed in nine of 36 hot spots (25%) and in three of 13 patients with focal FDG uptake. CONCLUSION: Fully integrated FDG PET/MRI can be used to study inflammation in asymptomatic AAAs. Heterogenous uptake of FDG in the aneurysmal wall indicates increased glucose metabolism, suggesting an ongoing inflammation. However, these FDG hotspots rarely correspond to MRI findings of inflammation, raising the question of which type of cellular activity is present in these areas. The presence of LGE and FDG hotspots both correlated to recent aneurysm growth, and their usefulness as clinical markers of aneurysm growth warrant additional investigation.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortite/diagnóstico por imagem , Fluordesoxiglucose F18/administração & dosagem , Angiografia por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Progressão da Doença , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Valor Preditivo dos Testes , Prognóstico
15.
J Cardiovasc Surg (Torino) ; 59(6): 789-796, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29781592

RESUMO

Progress of aortic disease after stent-graft treatment of aortic dissection includes the risk of stent graft-induced new entry (SINE). In this paper we review the incidence and mechanisms thought to be responsible for retrograde ascending and distal SINE after thoracic endovascular aortic repair (TEVAR) for type B dissection, and examine potential techniques for treatment and prevention. Although the risk of proximal SINE is low, the fatality of this complication requires vigilance in patients who develop new onset symptoms in the early period after TEVAR treatment. Careful technique, minimal oversizing, and use of disease specific stent grafts may reduce the risk for proximal SINE. Distally, SINE is more frequently seen during follow-up in patients treated for chronic dissection. The most important risk factor is oversizing of the stent-graft compared to the true lumen distal landing zone. Development of new disease specific stent grafts with reduced distal radial force may reduce the risk for distal SINE.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/cirurgia , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Resultado do Tratamento
16.
Eur J Vasc Endovasc Surg ; 56(1): 110-118, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29656960

RESUMO

OBJECTIVE: Abdominal aortic aneurysm (AAA) is characterised by enhanced proteolytic activity, and extracellular matrix (ECM) remodelling in the vascular wall. Type IV and XVIII collagen/endostatin are structural proteins in vascular basement membrane (VBM), a specialised ECM structure. Here the association between plasma levels of these collagens with the aortic diameter and expansion rate is studied, and their expression in aortic tissue characterised. METHODS: This was a retrospective population based cohort study. Type IV and XVIII collagen/endostatin were analysed in plasma by ELISA assay in 615 men, divided into three groups based on the aortic diameter: 1) normal aorta ≤ 25 mm, 2) sub-aneurysmal aorta (SAA) 26-29 mm, and 3) AAA ≥ 30 mm. Follow up data were available for 159 men. The association between collagen levels and aortic diameter at baseline, and with the expansion rate at follow up were analysed in ordinal logistic regression and linear regression models, controlling for common confounding factors. Tissue expression of the collagens was analysed in normal aorta (n = 6) and AAA (n = 6) by immunofluorescence. RESULTS: Plasma levels of type XVIII collagen/endostatin (136 ng/mL [SD 29] in individuals with a normal aorta diameter, 154 ng/ml [SD 45] in SAA, and 162 ng/ml [SD 46] in AAA; p = .001) and type IV collagen (105 ng/mL [SD 42] normal aorta, 124 ng/ml [SD 46] SAA, and 127 ng/ml [SD 47] AAA; p = .037) were associated with a larger aortic diameter. A significant association was found between the baseline levels of type XVIII/endostatin and the aortic expansion rate (p = .035), but in the multivariable model, only the initial aortic diameter remained significantly associated with expansion (p = .005). Altered expression patterns of both collagens were observed in AAA tissue. CONCLUSION: Plasma levels of circulating type IV and XVIII collagen/endostatin increase with AAA diameter. The expression pattern of VBM proteins is altered in the aneurysm wall.


Assuntos
Aorta Abdominal/química , Aneurisma da Aorta Abdominal/sangue , Membrana Basal/química , Colágeno Tipo IV/sangue , Colágeno Tipo XVIII/sangue , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Biomarcadores/sangue , Dilatação Patológica , Progressão da Doença , Endostatinas/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Imunofluorescência , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Remodelação Vascular
17.
Ups J Med Sci ; 119(3): 229-35, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24555564

RESUMO

OBJECTIVE: The aetiology and early pathophysiological mechanisms of aortic aneurysm formation are still unknown and challenging to study in vivo. Positron emission tomography (PET) is a potentially valuable instrument for non-invasive in vivo pathophysiological studies. No specific tracer to identify the pathophysiological process of aneurysmal dilatation is yet available, however. The aim of this study was to explore if different PET tracers could be useful to image aneurysmal disease. METHODS AND RESULTS: Human aneurysmal aortic tissue, collected during elective resection of abdominal aortic aneurysm (AAA) of asymptomatic patients, was investigated in vitro by means of autoradiography with [(68)Ga]CRP-binder targeting C-reactive protein, [(11)C]DAA1106 targeting translocator protein (18 kDa), [(11)C]D-deprenyl with unknown target receptor, [(11)C]deuterium-L-deprenyl targeting astrocytes, [(18)F]fluciclatide targeting integrin αVß3, [(68)Ga]IMP461 and bi-specific antibody TF2 052107 targeting carcinoembryonic antigen, [(18)F]F-metomidate targeting mitochondrial cytochrome P-450 species in the adrenal cortex, and [(18)F]vorozole targeting aromatase. Of the investigated tracers, only [(18)F]fluciclatide exhibited specific binding, whereas the other PET tracers failed to show specific uptake in the investigated tissue and are probably not useful for the intended purpose. CONCLUSION: It seems likely that αVß3 integrin expression in AAA can be visualized with PET and that the αVß3 selective tracer, [(18)F]fluciclatide, may be suitable for in vivo molecular imaging of asymptomatic AAA. Additional evaluation of [(18)F]fluciclatide and αVß3 integrin expression in AAA will be performed in vitro as well as in vivo.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Autorradiografia , Humanos , Masculino
18.
J Vasc Surg ; 56(3): 802-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22854268

RESUMO

OBJECTIVE: We hypothesized that the general inflammation observed in the wall of large, asymptomatic abdominal aortic aneurysms (AAAs) could be detected in vivo by 18-fluorodeoxglucose (FDG) positron-emission tomography (PET) and, if so, that this method could be used to study if active inflammation is an early pathogenetic finding in small AAAs detected by screening. METHODS: In this prospective clinical study, 12 men were examined with FDG-PET computed tomography. Seven had large asymptomatic AAAs (range, 52-66 mm) that required surgery, and five had small AAAs (range, 34-40 mm) under surveillance. In the surgery group, biopsy specimens were taken from the aneurysm wall for histologic examinations. RESULTS: Compared with normal segments of the aorta, liver, and blood and compared with healthy controls matched for age and sex, no increased FDG uptake, measured as standardized uptake value, was detected in any of the large or small AAAs. The SUV(mean) difference between infrarenal aorta and blood was -0.3 for cases and -0.1 for controls (P = .06). The corresponding differences between the infrarenal aorta and liver was -0.8 and -0.8 (P = .91) and between infrarenal aorta and suprarenal aorta was -0.2 and -0.1 for cases and controls, respectively (P = .20). The histologic examination of the aneurysm walls showed high inflammatory cell infiltration with T lymphocytes, B lymphocytes, and macrophages. CONCLUSIONS: The chronic inflammation observed in the wall of asymptomatic AAAs was not sufficiently metabolically active to result in an increased glucose metabolism detectable by FDG-PET by means of this standard protocol. To study the importance of inflammation in the pathogenesis of AAAs in vivo, PET tracers other than FDG need to be developed.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortite/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Idoso , Aorta Abdominal/imunologia , Aorta Abdominal/metabolismo , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/imunologia , Aneurisma da Aorta Abdominal/metabolismo , Aneurisma da Aorta Abdominal/patologia , Aortite/imunologia , Aortite/metabolismo , Aortite/patologia , Doenças Assintomáticas , Biópsia , Estudos de Casos e Controles , Fluordesoxiglucose F18/metabolismo , Humanos , Linfócitos/diagnóstico por imagem , Linfócitos/imunologia , Linfócitos/metabolismo , Linfócitos/patologia , Macrófagos/diagnóstico por imagem , Macrófagos/imunologia , Macrófagos/metabolismo , Macrófagos/patologia , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Compostos Radiofarmacêuticos/metabolismo , Suécia
19.
J Vasc Surg ; 45(4): 828-30, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17398393

RESUMO

Functional in vivo molecular imaging is provided with 18-fluorodeoxyglucose positron emission tomography (FDG-PET), which can detect cells with high glucose turnover. FDG-PET is an established imaging tool in oncology but has also been used in infectious and inflammatory diseases. PET combined with computed tomography (PET/CT) shows the metabolic activity with precise anatomic localization. More than 2000 scanners have now been installed worldwide, and with better availability, this hybrid method has the potential to become an important imaging tool in the management of suspected aortic graft infections, especially in patients with low-grade graft infection. We report a patient with a suspected aortic graft infection that was confirmed and anatomically localized by FDG-PET/CT. An extra-anatomic bypass and extirpation of the aortic graft was performed. The perioperative location of the graft infection coincided exactly with the place of FDG uptake shown on PET/CT. The patient had an uneventful postoperative recovery and did well during 6 months of follow-up.


Assuntos
Implante de Prótese Vascular , Prótese Vascular/efeitos adversos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Infecções Relacionadas à Prótese/diagnóstico , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Aorta/cirurgia , Remoção de Dispositivo , Enterococcus faecium/isolamento & purificação , Escherichia coli/isolamento & purificação , Humanos , Artéria Ilíaca/cirurgia , Klebsiella pneumoniae/isolamento & purificação , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/microbiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA