Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sci Adv ; 10(3): eadj1984, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38241380

RESUMO

Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Suínos , Animais , Procedimentos Cirúrgicos Robóticos/métodos , Laparoscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos
2.
Sci Rep ; 14(1): 1027, 2024 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-38200062

RESUMO

Instantaneous, continuous, and reliable information on the molecular biology of surgical target tissue could significantly contribute to the precision, safety, and speed of the intervention. In this work, we introduced a methodology for chemical tissue identification in robotic surgery using rapid evaporative ionisation mass spectrometry. We developed a surgical aerosol evacuation system that is compatible with a robotic platform enabling consistent intraoperative sample collection and assessed the feasibility of this platform during head and neck surgical cases, using two different surgical energy devices. Our data showed specific, characteristic lipid profiles associated with the tissue type including various ceramides, glycerophospholipids, and glycerolipids, as well as different ion formation mechanisms based on the energy device used. This platform allows continuous and accurate intraoperative mass spectrometry-based identification of ablated/resected tissue and in combination with robotic registration of images, time, and anatomical positions can improve the current robot-assisted surgical platforms and guide surgical strategy.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Fenômenos Físicos , Ceramidas , Espectrometria de Massas
3.
Biomedicines ; 11(7)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37509647

RESUMO

In recent years, steerable needles have attracted significant interest in relation to minimally invasive surgery (MIS). Specifically, the flexible, programmable bevel-tip needle (PBN) concept was successfully demonstrated in vivo in an evaluation of the feasibility of convection-enhanced delivery (CED) for chemotherapeutics within the ovine model with a 2.5 mm PBN prototype. However, further size reductions are necessary for other diagnostic and therapeutic procedures and drug delivery operations involving deep-seated tissue structures. Since PBNs have a complex cross-section geometry, standard production methods, such as extrusion, fail, as the outer diameter is reduced further. This paper presents our first attempt to demonstrate a new manufacturing method for PBNs that employs thermal drawing technology. Experimental characterisation tests were performed for the 2.5 mm PBN and the new 1.3 mm thermally drawn (TD) PBN prototype described here. The results show that thermal drawing presents a significant advantage in miniaturising complex needle structures. However, the steering behaviour was affected due to the choice of material in this first attempt, a limitation which will be addressed in future work.

5.
Adv Sci (Weinh) ; 10(2): e2204016, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36414395

RESUMO

Soft robots are envisioned as the next generation of safe biomedical devices in minimally invasive procedures. Yet, the difficulty of processing soft materials currently limits the size, aspect-ratio, manufacturing throughput, as well as, the design complexity and hence capabilities of soft robots. Multi-material thermal drawing is introduced as a material and processing platform to create soft robotic fibers imparted with multiple actuations and sensing modalities. Several thermoplastic and elastomeric material options for the fibers are presented, which all exhibit the rheological processing attributes for thermal drawing but varying mechanical properties, resulting in adaptable actuation performance. Moreover, numerous different fiber designs with intricate internal architectures, outer diameters of 700 µm, aspect ratios of 103 , and a fabrication at a scale of 10s of meters of length are demonstrated. A modular tendon-driven mechanism enables 3-dimensional (3D) motion, and embedded optical guides, electrical wires, and microfluidic channels give rise to multifunctionality. The fibers can perceive and autonomously adapt to their environments, as well as, probe electrical properties, and deliver fluids and mechanical tools to spatially distributed targets.


Assuntos
Robótica , Robótica/métodos , Elasticidade , Movimento (Física) , Microfluídica
6.
Biomed Mater ; 15(5): 055011, 2020 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-32330920

RESUMO

To achieve regeneration of long sections of damaged nerves, restoration methods such as direct suturing or autologous grafting can be inefficient. Solutions involving biohybrid implants, where neural stem cells are grown in vitro on an active support before implantation, have attracted attention. Using such an approach, combined with recent advancements in microfabrication technology, the chemical and physical environment of cells can be tailored in order to control their behaviors. Herein, a neural stem cell polycarbonate fiber scaffold, fabricated by 3D printing and thermal drawing, is presented. The combined effect of surface microstructure and chemical functionalization using poly-L-ornithine (PLO) and double-walled carbon nanotubes (DWCNTs) on the biocompatibility of the scaffold, induced differentiation of the neural stem cells (NSCs) and channeling of the neural cells was investigated. Upon treatment of the fiber scaffold with a suspension of DWCNTs in PLO (0.039 g l-1) and without recombinants a high degree of differentiation of NSCs into neuronal cells was confirmed by using nestin, galactocerebroside and doublecortin immunoassays. These findings illuminate the potential use of this biohybrid approach for the realization of future nerve regenerative implants.


Assuntos
Regeneração Nervosa , Células-Tronco Neurais/citologia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Materiais Biocompatíveis/química , Diferenciação Celular , Membrana Celular/metabolismo , Sobrevivência Celular , Células Cultivadas , Proteína Duplacortina , Fator 2 de Crescimento de Fibroblastos/metabolismo , Humanos , Imunoensaio , Nanotubos de Carbono/química , Nestina/química , Neurônios/citologia , Sistema Nervoso Periférico/patologia , Fenótipo , Impressão Tridimensional , Próteses e Implantes , Ratos , Propriedades de Superfície , Alicerces Teciduais/química
7.
Soft Robot ; 7(4): 421-443, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32077810

RESUMO

The development of miniaturized continuum robots has a wide range of applications in minimally invasive endoluminal interventions. To navigate inside tortuous lumens without impinging on the vessel wall and causing tissue damage or the risk of perforation, it is necessary to have simultaneous shape sensing of the continuum robot and its tip contact force sensing with the surrounding environment. Miniaturization and size constraint of the device have precluded the use of conventional sensing hardware and embodiment schemes. In this study, we propose the use of optical fibers for both actuation and tension/shape/force sensing. It uses a model-based method with structural compensation, allowing direct measurement of the cable tension near the base of the manipulator without increasing the dimensions. It further structurally filters out disturbances from the flexible shaft. In addition, a model is built by considering segment differences, cable interactions/cross talks, and external forces. The proposed model-based method can simultaneously estimate the shape of the manipulator and external force applied onto the robot tip. Detailed modeling and validation results demonstrate the accuracy and reliability of the proposed method for the miniaturized continuum robot for endoluminal intervention.


Assuntos
Robótica , Desenho de Equipamento , Lasers , Fibras Ópticas , Reprodutibilidade dos Testes
8.
Sci Rep ; 9(1): 3006, 2019 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-30816263

RESUMO

The accurate and timely identification of the causative organism of infection is important in ensuring the optimum treatment regimen is prescribed for a patient. Rapid evaporative ionisation mass spectrometry (REIMS), using electrical diathermy for the thermal disruption of a sample, has been shown to provide fast and accurate identification of microorganisms directly from culture. However, this method requires contact to be made between the REIMS probe and microbial biomass; resulting in the necessity to clean or replace the probes between analyses. Here, optimisation and utilisation of ambient laser desorption ionisation (ALDI) for improved speciation accuracy and analytical throughput is shown. Optimisation was completed on 15 isolates of Escherichia coli, showing 5 W in pulsatile mode produced the highest signal-to-noise ratio. These parameters were used in the analysis of 150 clinical isolates from ten microbial species, resulting in a speciation accuracy of 99.4% - higher than all previously reported REIMS modalities. Comparison of spectral data showed high levels of similarity between previously published electrical diathermy REIMS data. ALDI does not require contact to be made with the sample during analysis, meaning analytical throughput can be substantially improved, and further, increases the range of sample types which can be analysed in potential direct-from-sample pathogen detection.


Assuntos
Infecções por Escherichia coli/microbiologia , Escherichia coli/química , Lipídeos/análise , Técnicas de Diagnóstico Molecular/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Escherichia coli/classificação , Escherichia coli/patogenicidade , Infecções por Escherichia coli/diagnóstico , Humanos , Lasers , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/normas , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/normas
9.
IEEE Trans Biomed Eng ; 66(1): 208-216, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993497

RESUMO

OBJECTIVE: Probe-based confocal endomicroscopy is an emerging high-magnification optical imaging technique that provides in vivo and in situ cellular-level imaging for real-time assessment of tissue pathology. Endomicroscopy could potentially be used for intraoperative surgical guidance, but it is challenging to assess a surgical site using individual microscopic images due to the limited field-of-view and difficulties associated with manually manipulating the probe. METHODS: In this paper, a novel robotic device for large-area endomicroscopy imaging is proposed, demonstrating a rapid, but highly accurate, scanning mechanism with image-based motion control, which is able to generate histology-like endomicroscopy mosaics. The device also includes, for the first time in robotic-assisted endomicroscopy, the capability to ablate tissue without the need for an additional tool. RESULTS: The device achieves preprogrammed trajectories with positioning accuracy of less than 30 [Formula: see text], while the image-based approach demonstrated that it can suppress random motion disturbances up to [Formula: see text]. Mosaics are presented from a range of ex vivo human and animal tissues, over areas of more than [Formula: see text], scanned in approximate [Formula: see text]. CONCLUSION: This paper demonstrates the potential of the proposed instrument to generate large-area, high-resolution microscopic images for intraoperative tissue identification and margin assessment. SIGNIFICANCE: This approach presents an important alternative to current histology techniques, significantly reducing the tissue assessment time, while simultaneously providing the capability to mark and ablate suspicious areas intraoperatively.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Confocal/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Algoritmos , Animais , Mama/diagnóstico por imagem , Colo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Suínos
10.
Eur Arch Otorhinolaryngol ; 274(5): 2273-2279, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28190091

RESUMO

To compare intra-operative and post-operative effectiveness of fiber delivered CO2 laser to monopolar electrocautery in robot assisted tongue base surgery. Prospective non-randomized clinical study. Twenty moderate to severe obstructive sleep apnea (OSA) patients, non-compliant with Continuous Positive Airway Pressure (CPAP), underwent Transoral Robotic Surgery (TORS) using the Da Vinci surgical robot in our University Hospital. OSA was treated with monopolar electrocautery in 10 patients, and with flexible CO2 laser fiber in another 10 patients. The following parameters in the two sets are analyzed: Intraoperative bleeding that required cauterization, robot operating time, need for tracheotomy, postoperative self-limiting bleeding, length of hospitalization, duration until start of oral intake, pre-operative and post-operative minimum arterial oxygen saturation, pre-operative and post-operative Epworth Sleepiness Scale score, postoperative airway complication and postoperative pain. Mean follow-up was 12 months. None of the patients required tracheotomy and there were no intraoperative complications related to the use of the robot or the CO2 laser. The use of CO2 laser in TORS-assisted tongue base surgery resulted in less intraoperative bleeding that required cauterization, shorter robot operating time, shorter length of hospitalization, shorter duration until start of oral intake and less postoperative pain, when compared to electrocautery. Postoperative apnea-hypopnea index scores showed better efficacy of CO2 laser than electrocautery. Comparison of postoperative airway complication rates and Epworth sleepiness scale scores were found to be statistically insignificant between the two groups. The use of CO2 laser in robot assisted tongue base surgery has various intraoperative and post-operative advantages when compared to monopolar electrocautery.


Assuntos
Eletrocoagulação , Lasers de Gás , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos , Apneia Obstrutiva do Sono/cirurgia , Adulto , Pesquisa Comparativa da Efetividade , Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Feminino , Humanos , Lasers de Gás/efeitos adversos , Lasers de Gás/uso terapêutico , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Língua/cirurgia , Resultado do Tratamento , Turquia
11.
Chest ; 133(4): 892-6, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18198247

RESUMO

BACKGROUND: Thermal ablation is one of the most commonly used modalities to treat central airway obstruction. Both laser and argon plasma coagulation (APC) have been reported to cause gas emboli and cardiac arrest. We sought to determine whether bronchoscopic ablation therapy can result in systemic gas emboli, correlate their presence with the rate of gas flow, and establish whether a zero-flow (ZF) modality would result in the significant reduction or elimination of emboli. METHODS: CO(2) laser delivered through a photonic bandgap fiber (PBF) and APC were applied in the trachea and mainstem bronchi of six anesthetized sheep at varying dosages and gas flow rates. Direct epicardial echocardiography was used to obtain a four-chamber view and detect gas emboli. RESULTS: The presence of gas flow accompanying APC and the CO(2) laser with forward flow correlated significantly with the appearance of gas bubbles in the atria. A definite dose response was observed between the gas flow rate and the number of bubbles seen. When the CO(2) laser was delivered through a PBF with ZF to the trachea or bronchi, no bubbles were observed. CONCLUSION: Bronchoscopic thermal ablation therapy using gas flow is associated with gas emboli in a dose-dependent fashion. The use of the flexible PBF with ZF is not associated with the development of gas emboli. Further study is required to determine whether a clinically safe threshold of gas emboli exists, and the relationships among the pathologic depth of tissue destruction, gas flow, pulse duration, and the development of gas emboli.


Assuntos
Broncoscopia/métodos , Embolia Aérea/complicações , Embolia Aérea/etiologia , Parada Cardíaca/etiologia , Terapia a Laser/efeitos adversos , Lasers de Gás/efeitos adversos , Obstrução das Vias Respiratórias/cirurgia , Animais , Brônquios/diagnóstico por imagem , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Eletrocardiografia , Lasers de Gás/uso terapêutico , Ovinos , Traqueia/diagnóstico por imagem , Ultrassonografia
12.
Nature ; 420(6916): 650-3, 2002 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-12478288

RESUMO

Conventional solid-core optical fibres require highly transparent materials. Such materials have been difficult to identify owing to the fundamental limitations associated with the propagation of light through solids, such as absorption, scattering and nonlinear effects. Hollow optical fibres offer the potential to minimize the dependence of light transmission on fibre material transparency. Here we report on the design and drawing of a hollow optical fibre lined with an interior omnidirectional dielectric mirror. Confinement of light in the hollow core is provided by the large photonic bandgaps established by the multiple alternating submicrometre-thick layers of a high-refractive-index glass and a low-refractive-index polymer. The fundamental and high-order transmission windows are determined by the layer dimensions and can be scaled from 0.75 to 10.6 micro m in wavelength. Tens of metres of hollow photonic bandgap fibres for transmission of carbon dioxide laser light at 10.6 micro m wavelength were drawn. The transmission losses are found to be less than 1.0 dB m(-1), orders of magnitude lower than those of the intrinsic fibre material, thus demonstrating that low attenuation can be achieved through structural design rather than high-transparency material selection.

13.
Science ; 296(5567): 510-3, 2002 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-11964473

RESUMO

We report the design and fabrication of a multilayered macroscopic fiber preform and the subsequent drawing and optical characterization of extended lengths of omnidirectional dielectric mirror fibers with submicrometer layer thickness. A pair of glassy materials with substantially different indices of refraction, but with similar thermomechanical properties, was used to construct 21 layers of alternating refractive index surrounding a tough polymer core. Large directional photonic band gaps and high reflection efficiencies comparable to those of the best metallic reflectors were obtained. Potential applications of these fibers include woven fabrics for radiation barriers, spectral authentication of cloth, and filters for telecommunications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA