Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Zhongguo Gu Shang ; 36(10): 926-31, 2023 Oct 25.
Artigo em Chinês | MEDLINE | ID: mdl-37881923

RESUMO

OBJECTIVE: To compare the posterior cruciate ligament(PCL) index with six different measurement methods, and analyze and verify its clinical diagnostic value in anterior cruciate ligament (ACL) injury. METHODS: The Magnetic resonance imaging (MRI) data of 225 knee joints in our hospital from May 2018 to March 2022 were retrospectively analyzed, aged from 18 to 60 years old, with a median of 32 years old. On the sagittal MRI images of 114 patients with ACL injury and 111 patients with intact ACL, Measure the straight-line distance (A) between the femoral attachment point and the tibial attachment point of the PCL on the MRI sagittal image and the maximum vertical distance (B) between the straight line and the arcuate mark point of the PCL on the sagittal image, calculate the PCL index and evaluate the diagnostic value of the PCL index for ACL injury. RESULTS: The PCL index of the ACL normal group and the ACL injury group were statistically described. There was no significant difference in PCL index 1, 2, 3 and 6 between the two groups(P>0.05). The difference of PCL index 4 and 5 between the two groups was statistically significant (P<0.001). This study only found that the PCL index 2, 6 in the ACL normal group had a negative correlation with the patient's age (correlation coefficient=-0.213, -0.819;P<0.05), and the PCL index 5 in the ACL injury group was significantly correlated with the patient's body mass index(BMI)had a negative correlation (correlation coefficient=-0.277, P<0.05). CONCLUSION: The change of PCL index is helpful for the diagnosis of ACL injury, PCL index 4 and 5 can be used as effective reference indexes for diagnosing ACL injury in clinic.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Posterior , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior , Estudos Retrospectivos , Articulação do Joelho , Imageamento por Ressonância Magnética/métodos
2.
Quant Imaging Med Surg ; 13(8): 5195-5206, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37581068

RESUMO

Background: The graft bending angle created by the graft and the tibial tunnel has inevitably occurred during the transtibial posterior cruciate ligament (PCL) reconstruction. However, few studies quantitively analyzed this angle. This study aimed to (I) explore the optimal tibial tunnel placement to maximize the graft bending angle in the PCL reconstruction; (II) reveal the effect of the tibial tunnel placement on the graft bending angle. Methods: This was an in-vitro surgical simulation study based on the three-dimensional (3D) computed tomography (CT). A total of 55 patients who took CT scanning for knee injuries were selected (April 2020 to January 2022) from the local hospital database for review. The 3D knee models were established on the Mimics software based on the knees' CT data. Using the Rhinoceros software to simulate the transtibial PCL reconstruction on the 3D CT knee model. The anteromedial and anterolateral tibial tunnel approaches were simulated with different tibial tunnel angle. The graft bending angle and tibial tunnel length (TTL) with different tibial tunnel angles were quantitively analyzed. Results: The graft bending angle in anterolateral approach with a 50° tibial tunnel angle was significantly greater than it in anteromedial approach with a 60° tibial tunnel angle (P<0.001). There was no difference of the graft bending angle between the anterolateral approach with a 40° tibial tunnel angle and the anteromedial approach with a 60° tibial tunnel angle (P>0.05). The graft bending angle showed a strong correlation with the tibial tunnel angle (for anteromedial approach: r=0.759, P<0.001; for anterolateral approach: r=0.702, P<0.001). The best-fit equation to calculate the graft bending angle based on the tibial tunnel angle was Y = 0.89*X + 59.05 in anteromedial tibial tunnel approach (r2=0.576), and was Y = 0.78*X + 80.21 anterolateral tibial tunnel approach (r2=0.493). Conclusions: The graft bending angle and TTL will significantly increase as the tibial tunnel angle becomes greater. Maximizing the tibial tunnel angle (50° tibial tunnel angle) in the anterolateral approach could provide the greatest graft bending angle in the PCL reconstruction. No matter how the tibial tunnel angle is changed in the anteromedial approach, using anterolateral approach might reduce the killer turn effect more effectively than using anteromedial approach.

3.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 4035-4042, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37191693

RESUMO

PURPOSE: To biomechanically compare the initial fixation strength of grafts among three tibial tunnel angles (30°/45°/60°) in transtibial posterior cruciate ligament (PCL) reconstruction. METHODS: A series of transtibial PCL reconstruction models were established with porcine tibias and bovine tendons. Specimens were randomly assigned to three groups according to the angles between the tibial tunnel and the perpendicular line of the tibial shaft: Group A (30°, n = 12), Group B (45°, n = 12), and Group C (60°, n = 12). The area of the tunnel entrance, the segmental bone mineral density (sBMD) of the graft fixation site of the tibia and the maximum insertion torque of the interference screw were measured. Finally, load to failure tests were carried out on the graft-screw-tibia constructs at the same rate. RESULTS: Ultimate load to failure in Group C (335.2 ± 107.5 N) was significantly lower than that in Group A (584.1 ± 127.9 N, P < 0.01) and Group B (521.9 ± 95.9 N, P < 0.01). There were no significant differences between biomechanical properties of Groups A and B (n.s.). The posterior part fractures of the tibial tunnel exit occurred in eight specimens of Group C. In addition, the ultimate load was proven to be related to insertion torque (rho = 0.7, P < 0.01), sBMD (rho = 0.7, P < 0.01), and the area of the tunnel entrance (rho =- 0.4, P = 0.01). CONCLUSION: The ultimate load to failure was significantly lower in tibial PCL interference screw fixation for tunnels drilled at 60° compared to 30°/45°. In addition, the ultimate load was significantly correlated with insertion torque, sBMD and the area of the tunnel entrance. Given that the load to failure of distal fixation may not be sufficient for early postoperative rehabilitation, a 60° tunnel should not be recommended to drill in tibia during PCL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Posterior , Animais , Bovinos , Fenômenos Biomecânicos , Parafusos Ósseos , Ligamento Cruzado Posterior/cirurgia , Suínos , Tíbia/cirurgia
4.
Front Bioeng Biotechnol ; 11: 1118468, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36777256

RESUMO

Tendon-bone insertion (TBI) injuries are common, primarily involving the rotator cuff (RC) and anterior cruciate ligament (ACL). At present, repair surgery and reconstructive surgery are the main treatments, and the main factor determining the curative effect of surgery is postoperative tendon-bone healing, which requires the stable combination of the transplanted tendon and the bone tunnel to ensure the stability of the joint. Fibrocartilage and bone formation are the main physiological processes in the bone marrow tract. Therefore, therapeutic measures conducive to these processes are likely to be applied clinically to promote tendon-bone healing. In recent years, biomaterials and compounds, stem cells, cell factors, platelet-rich plasma, exosomes, physical therapy, and other technologies have been widely used in the study of promoting tendon-bone healing. This review provides a comprehensive summary of strategies used to promote tendon-bone healing and analyses relevant preclinical and clinical studies. The potential application value of these strategies in promoting tendon-bone healing was also discussed.

5.
J Orthop Surg (Hong Kong) ; 31(1): 10225536221151131, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36688346

RESUMO

BACKGROUND: The anatomical positioning of the graft during anterior cruciate ligament reconstruction (ACLR) is of great significance for restoring normal knee kinematics and preventing early joint degeneration. Therefore, the adjustment of the mispositioned guide pin becomes extremely important. Our research aims to test the time-zero biomechanical properties in adjusting inaccurate guide pins to the center of the tibial footprint in anatomical anterior cruciate ligament single-bundle reconstruction. METHODS: Porcine tibias and bovine extensor tendons were used to simulate a transtibial ACL reconstruction in vitro. Load-to failure testing was carried out in 4 groups: control group (n = 45): the guide pin was drilled at the center of the ACL footprint; group I, group II and group III (n = 45, respectively): the guide pin was respectively drilled 1 mm, 2 mm and 3 mm away from the center of the ACL footprint. In the experimental groups, a small tunnel with a 4.5 mm reamer is made and the guide pin is shifted to the center of the footprint. All the reamed tibias were scanned by CT to measure the area of the tunnel in the footprint, and time-zero biomechanical properties were recorded. RESULTS: All graft-tibia complexes failed because the grafts slipped past the interference screws. Compare to control group, the ultimate load, yield load, and tunnel exit area in group III decreased significantly (p < 0.05). Regarding to the ultimate load, yield load, tensile stiffness, twisting force and tunnel exit area, t-test showed no significant differences between control group and group I, group II respectively (p > 0.05). Pearson test showed that tunnel exit area was negatively correlated with other characteristics (p < 0.05). CONCLUSIONS: Surgical adjustment of the guide pin to the center of the tibial footprint may have significant influence in time-zero biomechanical properties in anatomical anterior cruciate ligament single-bundle reconstruction when the adjusted tibial tunnel was significantly enlarged compare to the standard tibial tunnel.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Animais , Bovinos , Suínos , Tíbia/cirurgia , Ligamento Cruzado Anterior/cirurgia , Cadáver , Articulação do Joelho/cirurgia , Fenômenos Biomecânicos , Lesões do Ligamento Cruzado Anterior/cirurgia
6.
Orthop Surg ; 15(3): 851-857, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36597708

RESUMO

OBJECTIVE: In order to reduce the "killer turn" effect, various tibial tunnels have been developed. However, few studies investigated the biomechanical effects of different tibial tunnels during PCL reconstruction. This study aims to compare the time-zero biomechanical properties of anteromedial, anterolateral, lower anteromedial, and lower anterolateral tibial tunnels in transtibial posterior cruciate ligament (PCL) reconstruction under load-to-failure loading. METHODS: Porcine tibias and bovine extensor tendons were used to simulate in vitro transtibial PCL reconstruction. Forty bovine extensor tendons and 40 porcine tibias were randomly divided into four experimental groups: anteromedial tunnel group (AM group, n = 10), anterolateral tunnel group (AL group, n = 10), lower anteromedial tunnel group (L-AM group, n = 10), and lower anterolateral tunnel group (L-AL group, n = 10). The biomechanical test was then carried out in each group using the load-to-failure test. The ultimate load (in newtons), yield load (in newtons), tensile stiffness (in newtons per millimeter), load-elongation curve, failure mode, and tibial tunnel length (in millimeter) were recorded for each specimen. One-way analysis of variance (ANOVA) was used to compare the mean differences among the four groups. RESULTS: The biomechanical outcomes showed that there were no differences in the mean tensile stiffness and failure mode among four groups. The ultimate load and yield load of the L-AM group were significantly higher than those of other three groups (P < 0.05). For the AM group, its ultimate load is significantly higher than that of the L-AL group (P < 0.05), and its yield load is higher than that of the AL group and L-AL group (P < 0.05). However, we found no significant differences in either ultimate load or yield load between AL group and L-AL group (P > 0.05). There was significant statistical difference in the length of tibial tunnel between anatomic groups (AM and AL) and lower groups (L-AM and L-AL) (P < 0.05). CONCLUSION: Compared with the anteromedial, anterolateral, and lower anterolateral tibial tunnel, the lower anteromedial tibial tunnel showed better time-zero biomechanical properties including ultimate load and yield load in transtibial PCL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Ligamento Cruzado Posterior , Animais , Bovinos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Suínos , Tendões , Tíbia/cirurgia
7.
Proc Inst Mech Eng H ; 237(1): 104-112, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36426874

RESUMO

No consensus has been reached on the optimal position of PCL tibial tunnel. The purpose of this study was to compare the biomechanical properties of proximal, distal and anatomic tibial tunnel in transtibial posterior cruciate ligament reconstruction. An in-vitro model of transtibial posterior cruciate ligament reconstruction was simulated using porcine tibias and bovine extensor tendons. Two models of biomechanical testing, load-to-failure loading, and cyclic loading, were performed in this study. The load-to-failure loading found that distal tibial tunnel resulted in greater ultimate load and yield load than the anatomic and proximal tunnel group (p < 0.05), whereas there were no significant differences in mean tensile stiffness among three groups (p > 0.05). The cyclic loading found no differences in the graft displacement at 250, 500, and 1000 cycles among three groups (p > 0.05). It was found that distal tibial tunnel showed superior ultimate load and yield load in load-to-failure loading testing compared with proximal and anatomic tibial tunnels, whereas no significant difference was found in terms of the mean displacement of the survived grafts in cyclic loading testing among three groups.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Ligamento Cruzado Posterior , Animais , Bovinos , Suínos , Tíbia/cirurgia , Reconstrução do Ligamento Cruzado Posterior/métodos , Fenômenos Biomecânicos , Tendões/cirurgia , Ligamento Cruzado Posterior/cirurgia
8.
Orthop J Sports Med ; 10(11): 23259671221137051, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36452338

RESUMO

Background: Patellar dislocation is attracting considerable research interest. Purpose: To assess studies on patellar dislocation using a scientometric method to better understand the current status of research and explore future study directions. Study Design: Scoping review. Methods: The Web of Science Core Collection database was selected to retrieve publications on patellar dislocation. Articles and reviews written in English with patellar dislocation as the main topic were included. Conference abstracts, notes, letters, expert opinions, and animal studies were excluded. A total of 4632 articles were identified in our initial search. In addition, Excel 2019, CiteSpace 6.1.R1, and VOSviewer 1.6.9 were used to analyze the h-index, the most highly cited publication, publication essentials, and research themes. Results: A total of 1485 articles were included in our analysis, with 36,608 citations and an h-index of 93. Overall, 1494 institutions and 195 journals were identified from these studies. The United States (n = 531) was the most productive country. The institution and journal with the largest number of articles were the Hospital for Special Surgery (n = 59) and Knee Surgery, Sports Traumatology, Arthroscopy (n = 212), respectively. The article "Scoring of Patellofemoral Disorders" by Kujala et al in 1993 was the most highly cited reference. The most commonly found terms used were patellar dislocation, patellar instability, medial patellofemoral ligament, knee, recurrent patellar dislocation, and soft tissue restraints. Four topics were identified after clustering analysis of key terms: risk factors, medial patellofemoral ligament reconstruction, patellar dislocation in skeletally immature patients, and lateral retinacular release. Conclusion: This scientometric review of articles on patellar dislocation summarized the current status of research (countries, institutions, and authors) and identified potential research directions.

9.
Orthop Surg ; 14(9): 2298-2306, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35920590

RESUMO

OBJECTIVE: During the transtibial posterior cruciate ligament (PCL) reconstruction, surgeons commonly pay more attention to the graft turning angle in the sagittal plane (GASP), but the graft turning angle in the coronal plane (GACP) is always neglected. This study hypothesized that the three-dimensional (3D) killer turn angle was determined by both the GASP and GACP, and aimed to quantitively analyze the effects of the GASP and GACP on the 3D killer turn angle. METHODS: This was an in-vitro computer simulation study of transtibial PCL reconstruction using 3D knee models. Patients with knee injuries who were CT scanned were selected from the CT database (April 2019 to January 2021) at a local hospital for reviewing. A total of 60 3D knees were simulated based on the knees' CT data. The femoral and tibial PCL attachment were located on the 3D knee model using the Rhinoceros software. The tibial tunnels were simulated based on different GASP and GACP. The effects of the GASP and GACP on the 3D killer turn angle were quantitatively analyzed. One-way analysis of variance was used to compare the outcomes in different groups. The regression analysis was performed to identify variables of the GASP and GACP which significantly affected 3D killer turn angle. RESULTS: The 3D killer turn angle showed a significant proportional relationship not only with the GASP (r2 > 0.868, P < 0.001), but also with the GACP (r2 > 0.467, P < 0.001). Every 10° change of the GACP caused 2.8° to 4.4° change of the 3D killer turn angle, whereas every 10° change of the GASP caused 6.4° to 9.2° change of the 3D killer turn angle. CONCLUSIONS: The 3D killer turn angle was significantly affected by both the GASP and GACP. During the transtibial PCL reconstruction, the proximal anterolateral tibial tunnel approach could increase the 3D killer turn angle more obviously compared with the most distal anteromedial tibial tunnel approach. To minimize the killer turn effect, both the GASP and GACP were required to be considered to increase.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Ligamento Cruzado Posterior , Simulação por Computador , Fêmur/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Posterior/cirurgia , Reconstrução do Ligamento Cruzado Posterior/métodos , Tíbia/cirurgia
10.
Orthop Surg ; 14(6): 1193-1202, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35478490

RESUMO

OBJECTIVE: To determine the permissive safe angle (PSA) of the tibial tunnel in transtibial posterior cruciate ligament (PCL) reconstruction based on a three-dimensional (3D) simulation study. METHODS: This was a computer simulation study of transtibial PCL reconstruction using 3D knee models. CT images of 90 normal knee joints from 2017 to 2020 were collected in this study, and 3D knee models were established based on CT data. The tunnel approaches were subdivided into the anterior 1/3 of the anteromedial tibia (T1), middle 1/2 of the anteromedial tibia (T2), the tibial crest (T3), anterior 1/3 of the anterolateral tibia (T4), middle 1/2 of the anterolateral tibia (T5). Five tibial tunnels (T1-T5) were simulated on the 3D knee models. The PSAs, in different tibial tunnel approaches were measured, and subgroup analyses of sex, age and height were also carried out. RESULTS: The mean PSAs of the tibial tunnels with 5 different approaches (T1-T5) were 58.49° ± 6.82°, 61.14° ± 6.69°, 56.12° ± 7.53°, 52.01° ± 8.89° and 49.90° ± 10.53°, respectively. The differences of the mean PSAs between the anteromedial and anterolateral approaches were significant (P < 0.05). However, there was no significant difference of the mean PSA value between the two anteromedial tibial tunnel approaches (T1-T2) (P > 0.05), as well as between the two anterolateral tibial tunnel approaches (T4-T5). The patient's anthropomorphic characteristics of sex, age, and height were not associated with the PSAs. CONCLUSIONS: The PSA varied with the anteromedial, tibial crest and anterolateral approaches for transtibial PCL reconstruction, and surgeons should limit the PCL drill guide by referring to the specific PSA for different surgical approaches.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Ligamento Cruzado Posterior , Simulação por Computador , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/diagnóstico por imagem , Ligamento Cruzado Posterior/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
11.
Knee Surg Sports Traumatol Arthrosc ; 30(7): 2377-2387, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35124715

RESUMO

PURPOSE: The posterior tibial slope (PTS) is considered a risk factor for anterior cruciate ligament (ACL) injury. However, the influence of PTS on graft failure following ACL reconstruction remains relatively unknown. Therefore, this systematic review was conducted to investigate whether PTS could be a potential risk factor for graft failure after ACL reconstruction. METHODS: PubMed, EMBASE, Cochrane Library, Web of Science, China National Knowledge Infrastructure Database, and Wanfang Database were comprehensively searched from inception to March 31, 2021. Observational studies reporting the associations of medial tibial plateau slope (MTPS) or lateral tibial plateau slope (LTPS) with graft failure after ACL reconstruction were evaluated. RESULTS: Twenty studies involving 12 case-control studies, 4 retrospective studies and 4 cross-sectional studies including 5326 patients met the final inclusion criteria. The high heterogeneity and the characteristics of nonrandomized controlled trials limited data synthesis. Fifteen of the 20 included studies detected a significant association between increased PTS and ACL graft failure, while 5 studies concluded that increased PTS was not associated with ACL graft failure. Ten studies suggested that MTPS is associated with ACL graft failure, and six studies suggested that LTPS is associated with ACL graft failure. The mean MTPS values for nonfailure group ranged from 3.5° ± 2.5° to 14.4° ± 2.8°. For the graft failure group, MTPS ranged from 4.71° ± 2.41° to 17.2° ± 2.2°. The mean LTPS values for nonfailure group ranged from 2.9° ± 2.1° to 11.9° ± 3.0°. For the graft failure group, LTPS ranged from 5.5° ± 3.0° to 13.3° ± 3.0°. The reported PTS values that caused ACL graft failure was greater than 7.4° to 17°. CONCLUSION: Based on the current clinical evidence, increased PTS is associated with a higher risk of ACL graft failure after ACL reconstruction. Despite various methods of measuring PTS have high reliability, there is still vast disagreement in the actual value of PTS. LEVEL OF EVIDENCE: IV.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos , Estudos Transversais , Humanos , Articulação do Joelho/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tíbia/cirurgia
12.
Clin Orthop Relat Res ; 480(5): 918-928, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35023873

RESUMO

BACKGROUND: To minimize the killer turn caused by the sharp margin of the tibial tunnel exit in transtibial PCL reconstruction, surgeons tend to maximize the angle of the tibial tunnel in relation to the tibial plateau. However, to date, no consensus has been reached regarding the maximum angle for the PCL tibial tunnel. QUESTIONS/PURPOSES: In this study we sought (1) to determine the maximum tibial tunnel angle for the anteromedial and anterolateral approaches in transtibial PCL reconstruction; (2) to compare the differences in the maximum angle based on three measurement methods: virtual radiographs, CT images, and three-dimensional (3D) knee models; and (3) to conduct a correlation analysis to determine whether patient anthropomorphic factors (age, sex, height, and BMI) are associated with the maximum tibial tunnel angle. METHODS: Between January 2018 and December 2020, 625 patients who underwent CT scanning for knee injuries were retrospectively reviewed in our institution. Inclusion criteria were patients 18 to 60 years of age with a Kellgren-Lawrence grade of knee osteoarthritis less than 1 and CT images that clearly showed the PCL tibial attachment. Exclusion criteria were patients with a history of tibial plateau fracture, PCL injuries, tumor, and deformity around the knee. Finally, 104 patients (43 males and 61 females, median age: 38 [range 24 to 56] years, height: 165 ± 9 cm, median BMI: 23 kg/cm2 [range 17 to 31]) were included for analysis. CT data were used to create virtual 3D knee models, and virtual true lateral knee radiographs were obtained by rotating the 3D knee models. Virtual 3D knee models were used as an in vitro standard method to assess the true maximum tibial tunnel angle of anteromedial and anterolateral approaches in transtibial PCL reconstruction. The tibial tunnel's entry was placed 1.5 cm anteromedial and anterolateral to the tibial tubercle for the two approaches. To obtain the maximum angle, a 10-mm- diameter tibial tunnel was simulated by making the tibial tunnel near the posterior tibial cortex. The maximum tibial tunnel angle, tibial tunnel lengths, and perpendicular distances of the tunnel's entry point to the tibial plateau were measured on virtual radiographs, CT images, and virtual 3D knee models. One-way ANOVA was used to compare the differences in the maximum angle among groups, and correlation analysis was performed to identify the relationship of the maximum angle and anthropomorphic factors (age, sex, height, and BMI). RESULTS: The maximum angle of the PCL tibial tunnel relative to the tibial plateau was greater in the anteromedial group than the anterolateral group (58° ± 8° versus 50° ± 8°, mean difference 8° [95% CI 6° to 10°]; p < 0.001). The maximum angle of the PCL tibial tunnel was greater in the virtual radiograph group than the CT image (68° ± 6° versus 49° ± 5°, mean difference 19° [95% CI 17° to 21°]; p < 0.001), the anteromedial approach (68° ± 6° versus 58° ± 8°, mean difference 10° [95% CI 8° to 12°]; p < 0.001), and the anterolateral approach (68° ± 6° versus 50° ± 8°, mean difference 18° [95% CI 16° to 20°]; p < 0.001), but no difference was found between the CT image and the anterolateral groups (49° ± 5° versus 50° ± 8°, mean difference -1° [95% CI -4° to 1°]; p = 0.79). We found no patient anthropomorphic characteristics (age, sex, height, and BMI) that were associated with the maximum angle. CONCLUSION: Surgeons should note that the mean maximum angle of the tibial tunnel relative to the tibial plateau was greater in the anteromedial than anterolateral approach in PCL reconstruction, and the maximum angle might be overestimated on virtual radiographs and underestimated on CT images. CLINICAL RELEVANCE: To perform PCL reconstruction more safely, the findings of this study suggest that the PCL drill system should be set differently for the anteromedial and anterolateral approaches, and the maximum angle measured by intraoperative fluoroscopy should be reduced 10° for the anteromedial approach and 18° for the anterolateral approach. Future clinical or cadaveric studies are needed to validate our findings.


Assuntos
Articulação do Joelho , Tíbia , Adulto , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X/efeitos adversos , Adulto Jovem
13.
BMC Musculoskelet Disord ; 22(1): 571, 2021 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-34158018

RESUMO

BACKGROUND: Interference screw is commonly used for graft fixation in anterior cruciate ligament (ACL) reconstruction. However, previous studies had reported that the insertion of interference screws significantly caused graft laceration. The purposes of this study were to (1) quantitatively evaluate the graft laceration from one single insertion of PEEK interference screws; and (2) determine whether different types of sutures reduced the graft laceration after one single insertion of interference screws in ACL reconstruction. METHODS: The in-vitro ACL reconstruction model was created using porcine tibias and bovine extensor digitorum tendons of bovine hind limbs. The ends of grafts were sutured using three different sutures, including the bioabsorbable, Ethibond and ultra-high molecular weight polyethylene (UHMWPE) sutures. Poly-ether-ether-ketone (PEEK) interference screws were used for tibial fixation. This study was divided into five groups (n = 10 in each group): the non-fixed group, the non-sutured group, the absorbable suture group, the Ethibond suture group and the UHMWPE suture group. Biomechanical tests were performed using the mode of pull-to-failure loading tests at 10 mm/min. Tensile stiffness (newtons per millimeter), energy absorbed to failure (in joules) and ultimate load (newtons) were recorded for analysis. RESULTS: All prepared tendons and bone specimens showed similar characteristics (length, weight, and pre-tension of the tendons, tibial bone mineral density) among all groups (P > 0.05). The biomechanical tests demonstrated that PEEK interference screws significantly caused the graft laceration (P < 0.05). However, all sutures (the bioabsorbable, Ethibond and UHMWPE sutures) did not reduce the graft laceration in ACL reconstruction (P > 0.05). CONCLUSIONS: Our biomechanical study suggested that the ultimate failure load of grafts was reduced of approximately 25 % after one single insertion of a PEEK interference screw in ACL reconstruction. Suturing the ends of the grafts using different sutures (absorbable, Ethibond and UHMWPE sutures) did not decrease the graft laceration caused by interference screws.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Lacerações , Animais , Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Fenômenos Biomecânicos , Parafusos Ósseos/efeitos adversos , Bovinos , Lacerações/etiologia , Lacerações/prevenção & controle , Lacerações/cirurgia , Suturas/efeitos adversos , Suínos , Tíbia/cirurgia
14.
Channels (Austin) ; 15(1): 339-359, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33775217

RESUMO

Articular cartilage consists of an extracellular matrix including many proteins as well as embedded chondrocytes. Articular cartilage formation and function are influenced by mechanical forces. Hind limb unloading or simulated microgravity causes articular cartilage loss, suggesting the importance of the healthy mechanical environment in articular cartilage homeostasis and implying a significant role of appropriate mechanical stimulation in articular cartilage degeneration. Mechanosensitive ion channels participate in regulating the metabolism of articular chondrocytes, including matrix protein production and extracellular matrix synthesis. Mechanical stimuli, including fluid shear stress, stretch, compression and cell swelling and decreased mechanical conditions (such as simulated microgravity) can alter the membrane potential and regulate the metabolism of articular chondrocytes via transmembrane ion channel-induced ionic fluxes. This process includes Ca2+ influx and the resulting mobilization of Ca2+ that is due to massive released Ca2+ from stores, intracellular cation efflux and extracellular cation influx. This review brings together published information on mechanosensitive ion channels, such as stretch-activated channels (SACs), voltage-gated Ca2+ channels (VGCCs), large conductance Ca2+-activated K+ channels (BKCa channels), Ca2+-activated K+ channels (SKCa channels), voltage-activated H+ channels (VAHCs), acid sensing ion channels (ASICs), transient receptor potential (TRP) family channels, and piezo1/2 channels. Data based on epithelial sodium channels (ENaCs), purinergic receptors and N-methyl-d-aspartate (NMDA) receptors are also included. These channels mediate mechanoelectrical physiological processes essential for converting physical force signals into biological signals. The primary channel-mediated effects and signaling pathways regulated by these mechanosensitive ion channels can influence the progression of osteoarthritis during the mechanosensory and mechanoadaptive process of articular chondrocytes.


Assuntos
Condrócitos , Cartilagem Articular , Matriz Extracelular/metabolismo , Osteoartrite , Transdução de Sinais , Estresse Mecânico
15.
Arthroscopy ; 37(7): 2191-2201, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33581296

RESUMO

PURPOSE: The purpose of this 3-dimensional (3D) surgical simulation study was to investigate the effects of axial and sagittal hinge axes (hinge axes in the axial and sagittal planes) on medial and lateral posterior tibial slope (PTS) in medial open-wedge high tibial osteotomy (OWHTO), and evaluate the quantitative relationship between hinge axis and PTS change. METHODS: Preoperative computed tomography data from patients with varus knee deformity were collected. A standard hinge axis (0°) and 12 different hinge axes (6 axial hinge axes and 6 sagittal hinge axes: ±10°, ±20°, and ±30°) were defined in a 3D surgical simulation of OWHTO using a bone model. The differences between before and after simulation surgery in medial and lateral PTS, medial proximal tibial angle, opening gap, and opening wedge angle were measured. RESULTS: In total, 93 varus knees in 93 patients were included for study. Compared with the standard hinge axis, axial hinge axis significantly affected medial and lateral PTS (P < .001). In contrast, sagittal hinge axis had no significant effect on medial and lateral PTS (P > .05). Every 10° change in axial hinge axis with a mean coronal valgus correction of 10° might result in approximately 1.6° of alteration in PTS. Stepwise regression analysis showed that axial hinge axis is the most significant factors affecting PTS (ß coefficient = 0.78, P < .001), followed by opening wedge angle (ß coefficient = 0.36, P < .001) and gap ratio (ß coefficient = 0.12, P < 0.001). CONCLUSION: Based on our findings of 3D OWHTO simulation, axial hinge axis significantly influences medial and lateral PTS in OWHTO, but sagittal hinge axis has no effect on change in PTS. Every 10° change of axial hinge axis with a 10° coronal valgus correction caused approximately 1.6° change of PTS. CLINICAL RELEVANCE: Hinge axis in the axial plane significantly affects PTS, but hinge axis in the sagittal plane has no effect on PTS. To maintain PTS, surgeons should make hinge axis at the true lateral position of the tibia in the axial plane. To intentionally alter PTS, an anterolateral axial hinge axis could be used to decrease PTS or a posterolateral axial hinge axis could be used to increase PTS. Opening wedge angle or gap ratio is also useful for intentional modification of PTS.


Assuntos
Osteoartrite do Joelho , Osteotomia , Humanos , Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Próteses e Implantes , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
16.
Arthroscopy ; 35(6): 1667-1673, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31072718

RESUMO

PURPOSE: To compare the time-zero biomechanical properties of 3 graft fixation techniques (proximal, distal, and combined fixation) within the tibial tunnel in transtibial posterior cruciate ligament (PCL) reconstruction. METHODS: Porcine tibias and bovine extensor tendons were used to simulate a transtibial PCL reconstruction in vitro. Load-to-failure testing was carried out in 3 groups: distal fixation alone (group I, n = 10), proximal fixation alone (group II, n = 10), and combined fixation (group III, n = 10). The load-elongation curve, tensile stiffness (in newtons per millimeter), ultimate load (in newtons), yield load (in newtons), energy absorbed to failure (in joules), and failure mode were recorded. RESULTS: All graft-tibia complexes failed because the grafts slipped past the interference screws. The tensile stiffness, yield load, and energy absorption in group I were significantly lower than those in group II and group III (tensile stiffness, 19.25 ± 9.68 N/mm in group I vs 34.92 ± 16.48 N/mm in group II [P = .016] and 32.31 ± 13.79 N/mm in group III [P = .041]; yield load, 265.36 ± 144.52 N in group I vs 398.23 ± 57.04 N in group II [P = .006] and 424.94 ± 74.00 N in group III [P = .001]; and energy absorption, 5.16 ± 2.35 J in group I vs 19.95 ± 3.48 J in group II [P < .001] and 21.09 ± 4.29 J in group III [P < .001]). No statistically significant differences in biomechanical properties were found between group II and group III (P > .05). CONCLUSIONS: Compared with distal fixation in transtibial PCL reconstruction, proximal fixation and combined fixation showed superior time-zero biomechanical properties. CLINICAL RELEVANCE: Proximal fixation and combined fixation produced superior biomechanical properties to distal fixation in transtibial PCL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Posterior/métodos , Ligamento Cruzado Posterior/cirurgia , Técnicas de Sutura , Tendões/transplante , Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Bovinos , Modelos Animais , Ligamento Cruzado Posterior/fisiopatologia , Suínos
17.
Front Pharmacol ; 10: 1671, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32082164

RESUMO

BACKGROUND: Although combination therapy with immune checkpoint inhibitors (ICIs) provides a promising efficacy in multiple cancers, their use is facing challenges for a high incidence of adverse effects. This meta-analysis was conducted to compare the risks of organ-specific immune-related adverse events (IRAEs) associated with ICI monotherapy versus combination therapy among cancer patients. METHODS: Electronic databases were systematically searched to include eligible randomized controlled trials (RCTs). Any-grade and 3-5 grade IRAEs (colitis, pneumonitis, hepatitis, hypothyroidism, hyperthyroidism, and hypophysitis) were extracted for meta-analysis. Two reviewers independently assessed the methodological quality. The RevMan 5.3.5 software was used for meta-analysis. RESULTS: A total of 10 studies involving 8 RCTs with 2716 patients were included in this study. The most common any-grade adverse event was colitis (14.5%), followed by hypothyroidism (13.8%), hepatitis (10.4%), hypophysitis (10.0%), hyperthyroidism (9.3%), and pneumonitis (4.6%). Meta-analysis showed that ICI combination therapy significantly increased the risks of any-grade IRAEs in colitis [relative risk (RR), 3.56; 95% confidence interval (CI), 1.56-8.12; p < 0.05], pneumonitis (RR, 2.31; 95% CI, 1.54-3.45; p < 0.05), hepatitis (RR, 2.54; 95% CI, 1.65-3.91; p < 0.05), hypothyroidism (RR, 2.17; 95% CI, 1.71-2.76; p < 0.05), hyperthyroidism (RR, 3.13; 95% CI, 2.08-4.70; p < 0.05), and hypophysitis (RR, 3.54; 95% CI, 2.07-6.07; p < 0.05) compared with ICI monotherapy, as well as 3-5 grade IRAEs in colitis (RR, 2.50; 95% CI, 1.62-3.86; p < 0.05), pneumonitis (RR, 1.99; 95% CI, 1.00-3.93; p = 0.05), and hepatitis (RR, 2.70; 95% CI, 1.29-5.63; p < 0.05). CONCLUSIONS: This meta-analysis demonstrated that, compared with ICI monotherapy, patients receiving ICI combination therapy significantly increased organ-specific IRAEs in colitis, hypothyroidism, hepatitis, hypophysitis, hyperthyroidism, and pneumonitis. The incidence and severity of organ-specific IRAEs were drug and dose independent.

18.
Arch Orthop Trauma Surg ; 139(4): 547-552, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30535809

RESUMO

INTRODUCTION: Excessive angle of the tibial tunnel may cause breakage of the posterior cortex in transtibial anatomic posterior cruciate ligament (PCL) reconstruction. However, a few studies have determined the permissible maximum angle of the tibial tunnel. The purpose of this study was to determine the permissible maximum angle of the tibial tunnel relative to the tibial plateau in transtibial anatomic PCL reconstruction and characterize the anatomic parameters of the tibial PCL attachment position. MATERIALS AND METHODS: Computed tomography (CT) scans of a consecutive series of 408 adult knees with normal PCL attachment were measured. The parameters measured were the permissible maximum angle (PMA) of the 10 mm-diameter tibial tunnel relative to the tibial plateau, the distance from the anterior orifice of the tibial tunnel to the tibial tuberosity (OTD), the anterior-posterior diameter (APD) of the tibial plateau, the distance from the center of PCL attachment site to the posterior edge of the tibial plateau (PPED), and the angle between the tibial plateau and the posterior tibial slope where the PCL insertion site was (PSA). Subgroup analysis was performed to determine the correlations between parameters, and sex, age, and height. The measurement reliability was evaluated by intraclass correlation coefficients (ICCs). RESULTS: The average value of PMA was 48.2 ± 5.4°, and it was not affected by sex, age, and height (P > 0.05). The values of OTD, APD, PPED, PSA, and height were significantly higher in males than females (OTD, P < 0.01; APD, P < 0.01; PPED, P < 0.01; PSA, P = 0.019; height, P < 0.01). With regard to age, we stratified the cases into three groups: the young (18-30 years old), the middle-aged (31-45 years old), and the elderly (46-60 years old). The mean value of OTD, APD, and height were significantly lower in the elderly than that in the middle-aged (P < 0.01, P < 0.01, P < 0.01, respectively). With regard to height, we stratified the cases into three groups: ~ 1.65 m (1), 1.66 ~ 1.75 m (2), and 1.76 m ~ (3). The mean value of OTD, APD, and PPED significantly increased with height, P < 0.05. The mean value of PSA was significant higher in II group than that in I group (P = 0.034). CONCLUSIONS: There should be a limit to the angle of the tibial tunnel in transtibial anatomic PCL reconstruction to prevent the fracture of posterior tunnel wall. The permissible maximum angle (PMA) of the 10 mm-diameter tibial tunnel relative to the tibial plateau was 48.2°. Besides, the determination of the value of OTD, APD, PPED, and PSA could provide a clinical reference to insertion site, depth, and angle of the tibial drill guide in PCL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Posterior , Tíbia , Estudos de Coortes , Humanos , Reprodutibilidade dos Testes , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
19.
BMC Musculoskelet Disord ; 19(1): 436, 2018 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-30522472

RESUMO

BACKGROUND: "Killer turn" effect is a critical explanation for the recurrent posterior laxity following transtibial posterior cruciate ligament (PCL) reconstruction, which affected by the angle of the tibial tunnel. Meanwhile, excessive tunnel angle would have an adverse impact on the healing of tendon to bone. The purpose was to evaluate the theoretical optimal angle of the tibial tunnel in transtibial anatomic PCL reconstruction. METHODS: The measurements were performed on CT sagittal plane, including the thickness of cancellous bone (L1), the theoretical optimal angle of the tibial tunnel (TOA, which was measured between tibial plateau and the extension cord connecting the center of PCL insertion site with a point 5 mm superior from marrow cavity vertex), L2 - the distance from anterior tunnel aperture to anterior end of tibial plateau, L3 - the distance from anterior tunnel aperture to tibial tuberosity (lowest edge of patellar ligament attachment). RESULTS: The value of TOA and L3 were 35.4 ± 7.9 ° and 26.8 ± 11.4 mm, respectively. L1 and L2 were higher in males than females (L1, P = 0.002; L2, P = 0.046). Regarding age, L1, TOA, L2 and L3 were higher in the 46-60 years group than 31-45 years group (P = 0.02, P = 0.001, P = 0.038, P = 0.032, respectively). With regard to height, L1 was lower in group I - < 1.66 m than group II - 1.66 to 1.75 m and group III - > 1.75 m (I v II, P = 0.015, I v III, P = 0.026). L2 was also lower in group I than group II and group III (I v II, P = 0.026, I v III, P = 0.006). TOA and L3 showed no significant differences among sex and height groups (P > 0.05). CONCLUSIONS: TOA (35.4 ° ± 7.9 °) and L3 (26.8 ± 11.4 mm) could be used as a reference for ideal tibial tunnel placement in transtibial anatomic PCL reconstruction, so as to prevent recurrent PCL laxity and ensure good graft healing. However, further clinical validation is needed.


Assuntos
Reconstrução do Ligamento Cruzado Posterior/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X , Adulto , Osso Esponjoso/anatomia & histologia , Osso Esponjoso/diagnóstico por imagem , Osso Esponjoso/cirurgia , Feminino , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Reconstrução do Ligamento Cruzado Posterior/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Prevenção Secundária , Tíbia/anatomia & histologia
20.
BMC Musculoskelet Disord ; 17(1): 384, 2016 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-27595993

RESUMO

BACKGROUND: Consistent reference data used for anatomic posterior cruciate ligament (PCL) reconstruction is not well defined. Quantitative guidelines defining the location of PCL attachment would aid in performing anatomic PCL reconstruction. The purpose was to characterize anatomic parameters of the PCL tibial attachment based on magnetic resonance imaging (MRI) in a large population of adult knees. METHODS: The PCL tibial attachment site was examined in 736 adult knees with an intact PCL using 3.0-T proton density-weighted sagittal MRI. The outcomes measured were the anterior-posterior diameter (APD) of the tibial plateau; angle between the tibial plateau and the posterior tibial 'shelf' (the slope where the PCL tibial attachment site was) (PTS); length of the PTS; proximal, central, and distal PCL attachment positions as well as the width of the PCL attachment site; and vertical dimension of the PCL attachment site inferior from the tibial plateau. RESULTS: The average APD of the tibia plateau was 33.6 ± 3.5 mm, yielding significant differences between males (35.5 ± 3.0 mm) and females (31.6 ± 2.7 mm), P <.05, and there was a significantly decreasing trend with increasing age in males (P <.05). Mean angle between the tibial plateau and the PTS was 122.4° ± 8.1°, and subgroup analysis showed that the young group had a differently smaller angle (120.9° ± 7.5°) than the middle-aged (123.7° ± 8.2°) and the old (123.4° ± 7.7°) in males population, while there were no significant differences between sexes (P >.05). The proximal, central positions and width of the PCL attachment site were 13.4 ± 3.0 mm, 17.8 ± 3.0 mm and 9.6 ± 2.4 mm along the PTS, with significant differences between males and females (P <.05), and accounted for 60.0 % ± 9.1 %, 80.0 % ± 4.6 % and 43.3 % ± 9.7 % of the PTS respectively, with no significant differences between sexes and among age groups (all P >.05). CONCLUSIONS: This study provides reference data of the tibial PCL attachment based on MRI in the sagittal orientation. In analysis of retrospective data from a large population of adult patients, the quantitative values can be used as references to define the inserted angle and depth of the drill guide, and the exact position and size of the tibial PCL tunnel for performing arthroscopic anatomic PCL reconstruction.


Assuntos
Ligamento Cruzado Posterior/diagnóstico por imagem , Adolescente , Adulto , Idoso , Artroscopia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/anatomia & histologia , Ligamento Cruzado Posterior/cirurgia , Valores de Referência , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA