Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cornea ; 43(10): 1264-1271, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39288344

RESUMO

PURPOSE: The purpose of this study was to investigate the effects of artificial tears (AT) on the sublayers of the tear film assessed by a novel tear film imaging (TFI) device. METHODS: The mucoaqueous layer thickness (MALT) and lipid layer thickness (LLT) of 198 images from 11 healthy participants, 9 of whom had meibomian gland disease, were prospectively measured before and after exposure to 3 different AT preparations (Refresh Plus; Retaine [RTA]; Systane Complete PF [SYS]), using a novel nanometer resolution TFI device (AdOM, Israel). Participants were assessed at baseline and at 1, 5, 10, 30, and 60 minutes after instilling 1 drop of AT during 3 sessions on separate days. Repeated-measures analysis of variances were used for comparisons with P < 0.05 considered significant. RESULTS: For all ATs, the mean MALT was greatest 1 minute after drop instillation, with an increase of 67%, 55%, and 11% above the baseline for SYS, Refresh Plus, and RTA, respectively. The SYS formulation demonstrated the highest percentage increases in mean MALT and LLT at most postdrop time points. The MALT differences were significantly higher in the SYS than in the RTA ( P = 0.014). After 60 minutes, no AT group demonstrated statistically significant changes in MALT or LLT compared with baseline. CONCLUSIONS: We report, for the first time, the effects of AT on MALT and LLT using a high-resolution TFI. A substantial acute mean MALT increase occurs 1 minute after AT instillation with all agents tested, but there were clear differences in response and durability, suggesting the benefits of choosing specific AT according to the needs of each patient.


Assuntos
Lubrificantes Oftálmicos , Lágrimas , Humanos , Projetos Piloto , Lágrimas/química , Masculino , Feminino , Estudos Prospectivos , Adulto , Lubrificantes Oftálmicos/administração & dosagem , Pessoa de Meia-Idade , Adulto Jovem , Disfunção da Glândula Tarsal/diagnóstico , Glândulas Tarsais/metabolismo , Glândulas Tarsais/efeitos dos fármacos , Glândulas Tarsais/diagnóstico por imagem
2.
Cornea ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416674

RESUMO

PURPOSE: The purpose of this study was to investigate the effects of artificial tears (AT) on the sublayers of the tear film assessed by a novel tear film imaging (TFI) device. METHODS: The mucoaqueous layer thickness (MALT) and lipid layer thickness (LLT) of 198 images from 11 healthy participants, 9 of whom had meibomian gland disease, were prospectively measured before and after exposure to 3 different AT preparations (Refresh Plus; Retaine [RTA]; Systane Complete PF [SYS]), using a novel nanometer resolution TFI device (AdOM, Israel). Participants were assessed at baseline and at 1, 5, 10, 30, and 60 minutes after instilling 1 drop of AT during 3 sessions on separate days. Repeated-measures analysis of variances were used for comparisons with P < 0.05 considered significant. RESULTS: For all ATs, the mean MALT was greatest 1 minute after drop instillation, with an increase of 67%, 55%, and 11% above the baseline for SYS, Refresh Plus, and RTA, respectively. The SYS formulation demonstrated the highest percentage increases in mean MALT and LLT at most postdrop time points. The MALT differences were significantly higher in the SYS than in the RTA (P = 0.014). After 60 minutes, no AT group demonstrated statistically significant changes in MALT or LLT compared with baseline. CONCLUSIONS: We report, for the first time, the effects of AT on MALT and LLT using a high-resolution TFI. A substantial acute mean MALT increase occurs 1 minute after AT instillation with all agents tested, but there were clear differences in response and durability, suggesting the benefits of choosing specific AT according to the needs of each patient.

3.
J Kidney Cancer VHL ; 9(2): 13-18, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35582346

RESUMO

Renal angiomyolipomas (AMLs) are a subset of perivascular epithelioid cell neoplasms (PEComas) that are associated with tuberous sclerosis complex (TSC). Epithelioid angiomyolipomas (EAMLs) are a rare variant of AML with more aggressive propensities. EAMLs with malignant potential can be difficult to distinguish from relatively benign AMLs and other renal tumors. Although there are no established criteria for predicting EAML malignancy, there are proposed histologic parameters that are associated with higher tumor risk. EAML can be treated with surgical resection as well as mTOR inhibitors. Here, we present a unique case of a patient with a 36-cm renal EAML metastatic to the lungs that was treated with complete surgical resection of the primary lesion and mTOR inhibition.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA