Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 17(5): e0268925, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35605005

RESUMO

Magnetic Resonance images (MRIs) are employed in brain Stereotactic Radiosurgery and Radiotherapy (SRS/SRT) for target and/or critical organ localization and delineation. However, MRIs are inherently distorted, which also impacts the accuracy of the Magnetic Resonance Imaging/Computed Tomography (MRI/CT) co-registration process. In this phantom-based study, geometric distortion is assessed in 3T T2-weighted images (T2WIs), while the efficacy of an MRI distortion correction technique is also evaluated. A homogeneous polymer gel-filled phantom was CT-imaged before being irradiated with 26 4-mm Gamma Knife shots at predefined locations (reference control points). The irradiated phantom was MRI-scanned at 3T, implementing a T2-weighted protocol suitable for SRS/SRT treatment planning. The centers of mass of all shots were identified in the 3D image space by implementing an iterative localization algorithm and served as the evaluated control points for MRI distortion detection. MRIs and CT images were spatially co-registered using a mutual information algorithm. The inverse transformation matrix was applied to the reference control points and compared with the corresponding MRI-identified ones to evaluate the overall spatial accuracy of the MRI/CT dataset. The mean image distortion correction technique was implemented, and resulting MRI-corrected control points were compared against the corresponding reference ones. For the scanning parameters used, increased MRI distortion (>1mm) was detected at areas distant from the MRI isocenter (>5cm), while median radial distortion was 0.76mm. Detected offsets were slightly higher for the MRI/CT dataset (0.92mm median distortion). The mean image distortion correction improves geometric accuracy, but residual distortion cannot be considered negligible (0.51mm median distortion). For all three datasets studied, a statistically significant positive correlation between detected spatial offsets and their distance from the MRI isocenter was revealed. This work contributes towards the wider adoption of 3T imaging in SRS/SRT treatment planning. The presented methodology can be employed in commissioning and quality assurance programmes of corresponding treatment workflows.


Assuntos
Radiocirurgia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X
2.
J Appl Clin Med Phys ; 23(5): e13580, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35285583

RESUMO

PURPOSE: In frame-based Gamma Knife (GK) stereotactic radiosurgery two treatment planning workflows are commonly employed; one based solely on magnetic resonance (MR) images and the other based on magnetic resonance/computed tomography (MR/CT) co-registered images. In both workflows, target localization accuracy (TLA) can be deteriorated due to MR-related geometric distortions and/or MR/CT co-registration uncertainties. In this study, the overall TLA following both clinical workflows is evaluated for cases of multiple brain metastases. METHODS: A polymer gel-filled head phantom, having the Leksell stereotactic headframe attached, was CT-imaged and irradiated by a GK Perfexion unit. A total of 26 4-mm shots were delivered at 26 locations directly defined in the Leksell stereotactic space (LSS), inducing adequate contrast in corresponding T2-weighted (T2w) MR images. Prescribed shot coordinates served as reference locations. An additional MR scan was acquired to implement the "mean image" distortion correction technique. The TLA for each workflow was assessed by comparing the radiation-induced target locations, identified in MR images, with corresponding reference locations. Using T1w MR and CT images of 15 patients (totaling 81 lesions), TLA in clinical cases was similarly assessed, considering MR-corrected data as reference. For the MR/CT workflow, both global and region of interest (ROI)-based MR/CT registration approaches were studied. RESULTS: In phantom measurements, the MR-corrected workflow demonstrated unsurpassed TLA (median offset of 0.2 mm) which deteriorated for MR-only and MR/CT workflows (median offsets of 0.8 and 0.6 mm, respectively). In real-patient cases, the MR-only workflow resulted in offsets that exhibit a significant positive correlation with the distance from the MR isocenter, reaching 1.1 mm (median 0.6 mm). Comparable results were obtained for the MR/CT-global workflow, although a maximum offset of 1.4 mm was detected. TLA was improved with the MR/CT-ROI workflow resulting in median/maximum offsets of 0.4 mm/1.1 mm. CONCLUSIONS: Subpixel TLA is achievable in all workflows. For the MR/CT workflow, a ROI-based MR/CT co-registration approach could considerably increase TLA and should be preferred instead of a global registration.


Assuntos
Radiocirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Radiocirurgia/métodos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA