Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38722382

RESUMO

Chimeric antigen receptor (CAR) cell therapies utilize CARs to redirect immune cells towards cancer cells expressing specific antigens like human epidermal growth factor receptor 2 (HER2). Despite their potential, CAR T cell therapies exhibit variable response rates and adverse effects in some patients. Non-invasive molecular imaging can aid in predicting patient outcomes by tracking infused cells post-administration. CAR-T cells are typically autologous, increasing manufacturing complexity and costs. An alternative approach involves developing CAR natural killer (CAR-NK) cells as an off-the-shelf allogeneic product. In this study, we engineered HER2-targeted CAR-NK cells co-expressing the positron emission tomography (PET) reporter gene human sodium-iodide symporter (NIS) and assessed their therapeutic efficacy and PET imaging capability in a HER2 ovarian cancer mouse model.NK-92 cells were genetically modified to express a HER2-targeted CAR, the bioluminescence imaging reporter Antares, and NIS. HER2-expressing ovarian cancer cells were engineered to express the bioluminescence reporter Firefly luciferase (Fluc). Co-culture experiments demonstrated significantly enhanced cytotoxicity of CAR-NK cells compared to naive NK cells. In vivo studies involving mice with Fluc-expressing tumors revealed that those treated with CAR-NK cells exhibited reduced tumor burden and prolonged survival compared to controls. Longitudinal bioluminescence imaging demonstrated stable signals from CAR-NK cells over time. PET imaging using the NIS-targeted tracer 18F-tetrafluoroborate ([18F]TFB) showed significantly higher PET signals in mice treated with NIS-expressing CAR-NK cells.Overall, our study showcases the therapeutic potential of HER2-targeted CAR-NK cells in an aggressive ovarian cancer model and underscores the feasibility of using human-derived PET reporter gene imaging to monitor these cells non-invasively in patients.

2.
MAGMA ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635150

RESUMO

Neurodegenerative disorders, including Multiple Sclerosis (MS), are heterogenous disorders which affect the myelin sheath of the central nervous system (CNS). Magnetic Resonance Imaging (MRI) provides a non-invasive method for studying, diagnosing, and monitoring disease progression. As an emerging research area, many studies have attempted to connect MR metrics to underlying pathophysiological presentations of heterogenous neurodegeneration. Most commonly, small animal models are used, including Experimental Autoimmune Encephalomyelitis (EAE), Theiler's Murine Encephalomyelitis (TMEV), and toxin models including cuprizone (CPZ), lysolecithin, and ethidium bromide (EtBr). A contrast and comparison of these models is presented, with focus on the cuprizone model, followed by a review of literature studying neurodegeneration using MRI and the cuprizone model. Conventional MRI methods including T1 Weighted (T1W) and T2 Weighted (T2W) Imaging are mentioned. Quantitative MRI methods which are sensitive to diffusion, magnetization transfer, susceptibility, relaxation, and chemical composition are discussed in relation to studying the CPZ model. Overall, additional studies are needed to improve both the sensitivity and specificity of MRI metrics for underlying pathophysiology of neurodegeneration and the relationships in attempts to clear the clinico-radiological paradox. We therefore propose a multiparametric approach for the investigation of MR metrics for underlying pathophysiology.

4.
EJNMMI Res ; 13(1): 90, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37823919

RESUMO

BACKGROUND: After myocardial infarction, fibrosis and an ongoing dysregulated inflammatory response have been shown to lead to adverse cardiac remodeling. FDG PET is an imaging modality sensitive to inflammation as long as suppression protocols are observed while gadolinium enhanced MRI can be used to determine extracellular volume (ECV), a measure of fibrosis. In patients, glucose suppression is achieved variously through a high fat diet, fasting and injection of heparin. To emulate this process in canines, a heparin injection and lipid infusion are used, leading to similar fatty acids in the blood. The aim of this study was to examine the effect of glucose suppression on the uptake of FDG in the infarcted myocardial tissue and also on the determination of ECV in both the infarcted tissue and in the myocardium remote to the zone of infarction during a long constant infusion of FDG and Gd-DTPA. RESULTS: Extracellular volume was affected neither by suppression nor the length of the constant infusion in remote and infarcted tissue. Metabolic rate of glucose in infarcted tissue decreased during and after suppression of glucose uptake by lipid infusion and heparin injection. An increase in fibrosis and inflammatory cells was found in the center of the infarct as compared to remote tissue. CONCLUSION: The decrease in the metabolic rate of glucose in the infarcted tissue suggests that inflammatory cells may be affected by glucose suppression through heparin injection and lipid infusion.

5.
J Magn Reson Imaging ; 2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37589418

RESUMO

BACKGROUND: Ischemic heart disease (IHD) is linked to brain white matter (WM) breakdown but how age or disease effects WM integrity, and whether it is reversible using cardiac rehabilitation (CR), remains unclear. PURPOSE: To assess the effects of brain aging, cardiovascular disease, and CR on WM microstructure in brains of IHD patients following a cardiac event. STUDY TYPE: Retrospective. POPULATION: Thirty-five IHD patients (9 females; mean age = 59 ± 8 years), 21 age-matched healthy controls (10 females; mean age = 59 ± 8 years), and 25 younger controls (14 females; mean age = 26 ± 4 years). FIELD STRENGTH/SEQUENCE: 3 T diffusion-weighted imaging with single-shot echo planar imaging acquired at 3 months and 9 months post-cardiac event. ASSESSMENT: Tract-based spatial statistics (TBSS) and tractometry were used to compare fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) in cerebral WM between: 1) older and younger controls to distinguish age-related from disease-related WM changes; 2) IHD patients at baseline (pre-CR) and age-matched controls to investigate if cardiovascular disease exacerbates age-related WM changes; and 3) IHD patients pre-CR and post-CR to investigate the neuroplastic effect of CR on WM microstructure. STATISTICAL TESTS: Two-sample unpaired t-test (age: older vs. younger controls; IHD: IHD pre-CR vs. age-matched controls). One-sample paired t-test (CR: IHD pre- vs. post-CR). Statistical threshold: P < 0.05 (FWE-corrected). RESULTS: TBSS and tractometry revealed widespread WM changes in older controls compared to younger controls while WM clusters of decreased FA in the fornix and increased MD in body of corpus callosum were observed in IHD patients pre-CR compared to age-matched controls. Robust WM improvements (increased FA, increased AD) were observed in IHD patients post-CR. DATA CONCLUSION: In IHD, both brain aging and cardiovascular disease may contribute to WM disruptions. IHD-related WM disruptions may be favorably modified by CR. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

6.
BMC Cancer ; 23(1): 362, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37081426

RESUMO

BACKGROUND: Isolated local failure (ILF) can occur in patients who initially receive definitive radiation therapy for prostate cancer. Salvage therapy for ILF includes high dose rate (HDR) brachytherapy. Prostate Specific Membrane Antigen (PSMA) Positron Emission Tomography (PET) can accurately detect ILF and can exclude extraprostatic disease. Lutetium-177 PSMA Radioligand Therapy (RLT) is a novel treatment for prostate cancer that can target prostate cancer accurately, while sparing radiation dose to normal tissues. METHODS: ROADSTER is a phase I/II randomized, single-institution study. Patients with an ILF of prostate cancer after definitive initial radiation therapy are eligible. The ILF will be confirmed with biopsy, magnetic resonance imaging (MRI) and PSMA PET. Patients will be randomized between HDR brachytherapy in two fractions (a standard of care salvage treatment at our institution) (cohort 1) or one treatment of intravenous Lutetium-177 PSMA RLT, followed by one fraction of HDR brachytherapy (cohort 2). The primary endpoints for the phase I portion of the study (n = 12) will be feasibility, defined as 10 or more patients completing the study protocol within 24 months of study activation; and safety, defined as zero or one patients in cohort 2 experiencing grade 3 or higher toxicity in the first 6 months post-treatment. If feasibility and safety are achieved, the study will expand to a phase II study (n = 30 total) where preliminary efficacy data will be evaluated. Secondary endpoints include changes in prostate specific antigen levels, acute toxicity, changes in quality of life, and changes in translational biomarkers. Translational endpoints will include interrogation of blood, urine, and tissue for markers of DNA damage and immune activation with each treatment. DISCUSSION: ROADSTER explores a novel salvage therapy for ILF after primary radiotherapy with combined Lutetium-177 PSMA RLT and HDR brachytherapy. The randomized phase I/II design will provide a contemporaneous patient population treated with HDR alone to facilitate assessment of feasibility, tolerability, and biologic effects of this novel therapy. TRIAL REGISTRATION: NCT05230251 (ClinicalTrials.gov).


Assuntos
Braquiterapia , Neoplasias da Próstata , Humanos , Masculino , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Próstata/patologia , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Qualidade de Vida , Tomografia Computadorizada por Raios X
7.
Nanoscale ; 15(7): 3408-3418, 2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36722918

RESUMO

Stem cell-based therapies have demonstrated significant potential in clinical applications for many debilitating diseases. The ability to non-invasively and dynamically track the location and viability of stem cells post administration could provide important information on individual patient response and/or side effects. Multi-modal cell tracking provides complementary information that can offset the limitations of a single imaging modality to yield a more comprehensive picture of cell fate. In this study, mesenchymal stem cells (MSCs) were engineered to express human sodium iodide symporter (NIS), a clinically relevant positron emission tomography (PET) reporter gene, as well as labeled with superparamagnetic iron oxide nanoparticles (SPIOs) to allow for detection with magnetic particle imaging (MPI). MSCs were additionally engineered with a preclinical bioluminescence imaging (BLI) reporter gene for comparison of BLI cell viability data to both MPI and PET data over time. MSCs were implanted into the hind limbs of immunocompromised mice and imaging with MPI, BLI and PET was performed over a 30-day period. MPI showed sensitive detection that steadily declined over the 30-day period, while BLI showed initial decreases followed by later rapid increases in signal. The PET signal of MSCs was significantly higher than the background at later timepoints. Early-phase imaging (day 0-9 post MSC injections) showed correlation between MPI and BLI data (R2 = 0.671), while PET and BLI showed strong correlation for late-phase (day 10-30 post MSC injections) imaging timepoints (R2 = 0.9817). We report the first use of combined MPI and PET for cell tracking and show the complementary benefits of MPI for sensitive detection of MSCs early after implantation and PET for longer-term measurements of cell viability.


Assuntos
Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Camundongos , Animais , Humanos , Transplante de Células-Tronco Mesenquimais/métodos , Tomografia por Emissão de Pósitrons/métodos , Genes Reporter , Fenômenos Magnéticos
8.
Mol Imaging Biol ; 25(2): 271-282, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36418769

RESUMO

INTRODUCTION: The reliance on glycolytic metabolism is a hallmark of tumor metabolism. Excess acid and protons are produced, leading to an acidic tumor environment. Therefore, we explored the relationship between the tumor glycolytic metabolism and tissue pH by comparing 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) and hyperpolarized [1-13C]pyruvate MR spectroscopy imaging (MRSI) to chemical exchange saturation transfer (CEST) MRI measurements of tumor pH. METHODS: 106 C6 glioma cells were implanted in the brains of male Wistar rats (N = 11) using stereotactic surgery. A 60-min PET acquisition after a bolus of FDG was performed at 11-13 days post implantation, and standardized uptake value (SUV) was calculated. CEST measurements were acquired the following day before and during constant infusion of glucose solution. Tumor intracellular pH (pHi) was evaluated using amine and amide concentration-independent detection (AACID) CEST MRI. The change of pHi (∆pHi) was calculated as the difference between pHi pre- and during glucose infusion. Rats were imaged immediately with hyperpolarized [1-13C]pyruvate MRSI. Regional maps of the ratio of Lac:Pyr were acquired. The correlations between SUV, Lac:Pyr ratio, and ∆pHi were evaluated using Pearson's correlation. RESULTS: A decrease of 0.14 in pHi was found after glucose infusion in tumor region. Significant correlations between tumor glycolysis measurements of Lac:Pyr and ∆pHi within the tumor (ρ = 0.83, P = 0.01) and peritumoral region (ρ = 0.76, P = 0.028) were observed. No significant correlations were found between tumor SUV and ∆pHi within the tumor (ρ = - 0.45, P = 0.17) and peritumor regions (ρ = - 0.6, P = 0.051). CONCLUSION: AACID detected the changes in pHi induced by glucose infusion. Significant correlations between tumor glycolytic measurement of Lac:Pyr and tumoral and peritumoral pHi and ∆pHi suggest the intrinsic relationship between tumor glycolytic metabolism and the tumor pH environment as well as the peritumor pH environment.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Ratos , Masculino , Animais , Glioblastoma/patologia , Neoplasias Encefálicas/patologia , Fluordesoxiglucose F18 , Glucose , Concentração de Íons de Hidrogênio , Ratos Wistar , Imageamento por Ressonância Magnética/métodos , Glicólise , Piruvatos
9.
Eur J Hybrid Imaging ; 6(1): 31, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36336748

RESUMO

BACKGROUND: Positron emission tomography (PET) in combination with magnetic resonance imaging (MRI) could allow inflammatory complications near total knee arthroplasty (TKA) to be studied early in their development. However, attenuation of the PET signal by the metal TKA implants imparts substantial error into measurements of tracer activity, and conventional MR-based attenuation correction (AC) methods have large signal voids in the vicinity of metal implants. PURPOSE: To evaluate a segmentation-based AC approach to measure tracer uptake from PET/MRI scans near TKA implants. METHODS: A TKA implant (Triathlon, Stryker, Mahwah, USA) was implanted into a cadaver. Four vials were filled with [18F]fluorodeoxyglucose with known activity concentration (4.68 MBq total, 0.76 MBq/mL) and inserted into the knee. Images of the knee were acquired using a 3T PET/MRI system (Biograph mMR, Siemens Healthcare, Erlangen, Germany). Models of the implant components were registered to the MR data using rigid-body transformations and the other tissue classes were manually segmented. These segments were used to create the segmentation-based map and complete the AC. Percentage error of the resulting measured activities was calculated by comparing the measured and known amounts of activity in each vial. RESULTS: The original AC resulted in a percentage error of 64.1% from the known total activity. Errors in the individual vial activities ranged from 40.2 to 82.7%. Using the new segmentation-based AC, the percentage error of the total activity decreased to 3.55%. Errors in the individual vials were less than 15%. CONCLUSIONS: The segmentation-based AC technique dramatically reduced the error in activity measurements that result from PET signal attenuation by the metal TKA implant. This approach may be useful to enhance the reliability of PET/MRI measurements for numerous applications.

10.
Phys Imaging Radiat Oncol ; 21: 115-122, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35359488

RESUMO

Brain metastases affect more breast cancer patients than ever before due to increased overall patient survival with improved molecularly targeted treatments. Approximately 25-34% of breast cancer patients develop brain metastases in their lifetime. Due to the blood-brain barrier (BBB), the standard treatment for breast cancer brain metastases (BCBM) is surgery, stereotactic radiosurgery (SRS) and/or whole brain radiation therapy (WBRT). At the cost of cognitive side effects, WBRT has proven efficacy in treating brain metastases when used with local therapies such as SRS and surgery. This review investigated the potential use of glial activation positron emission tomography (PET) imaging for radiation treatment of BCBM. In order to put these studies into context, we provided background on current radiation treatment approaches for BCBM, our current understanding of the brain microenvironment, its interaction with the peripheral immune system, and alterations in the brain microenvironment by BCBM and radiation. We summarized preclinical literature on the interactions between glial activation and cognition and clinical studies using translocator protein (TSPO) PET to image glial activation in the context of neurological diseases. TSPO-PET is not employed clinically in assessing and guiding cancer therapies. However, it has gained traction in preclinical studies where glial activation was investigated from primary brain cancer, metastases and radiation treatments. Novel glial activation PET imaging and its applications in preclinical studies using breast cancer models and glial immunohistochemistry are highlighted. Lastly, we discuss the potential clinical application of glial activation imaging to improve the therapeutic ratio of radiation treatments for BCBM.

11.
EJNMMI Res ; 11(1): 107, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34652551

RESUMO

PURPOSE: Localized prostate cancer (PCa) in patients is characterized by a dominant focus in the gland (dominant intraprostatic lesion, DIL). Accurate DIL identification may enable more accurate diagnosis and therapy through more precise targeting of biopsy, radiotherapy and focal ablative therapies. The goal of this study is to validate the performance of [18F]DCFPyL PET and CT perfusion (CTP) for detecting and localizing DIL against digital histopathological images. METHODS: Multi-modality image sets: in vivo T2-weighted (T2w)-MRI, 22-min dynamic [18F]DCFPyL PET/CT, CTP, and 2-h post-injection PET/MR were acquired in patients prior to radical prostatectomy. The explanted gland with implanted fiducial markers was imaged with T2w-MRI. All images were co-registered to the pathologist-annotated digital images of whole-mount mid-gland histology sections using fiducial markers and anatomical landmarks. Regions of interest encompassing DIL and non-DIL tissue were drawn on the digital histopathological images and superimposed on PET and CTP parametric maps. Logistic regression with backward elimination of parameters was used to select the most sensitive parameter set to distinguish DIL from non-DIL voxels. Leave-one-patient-out cross-validation was performed to determine diagnostic performance. RESULTS: [18F]DCFPyL PET and CTP parametric maps of 15 patients were analyzed. SUVLate and a model combining Ki and k4 of [18F]DCFPyL achieved the most accurate performance distinguishing DIL from non-DIL voxels. Both detection models achieved an AUC of 0.90 and an error rate of < 10%. Compared to digital histopathology, the detected DILs had a mean dice similarity coefficient of 0.8 for the Ki and k4 model and 0.7 for SUVLate. CONCLUSIONS: We have validated using co-registered digital histopathological images that parameters from kinetic analysis of 22-min dynamic [18F]DCFPyL PET can accurately localize DILs in PCa for targeting of biopsy, radiotherapy, and focal ablative therapies. Short-duration dynamic [18F]DCFPyL PET was not inferior to SUVLate in this diagnostic task. CLINICAL TRIAL REGISTRATION NUMBER: NCT04009174 (ClinicalTrials.gov).

12.
EJNMMI Phys ; 8(1): 24, 2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33683464

RESUMO

BACKGROUND: Accurate quantification of radioactivity, measured by an integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) system, is still a challenge. One aspect of such a challenge is to correct for the hardware attenuation, such as the patient table and radio frequency (RF) resonators. For PET/MRI systems, computed tomography (CT) is commonly used to produce hardware attenuation correction (AC) maps, by converting Hounsfield units (HU) to a linear attenuation coefficients (LAC) map at the PET energy level 511 keV, using a bilinear model. The model does not address beam hardening, nor higher density materials, which can lead to inaccurate corrections. PURPOSE: In this study, we introduce a transmission-based (TX-based) AC technique with a static Germanium-68 (Ge-68) transmission source to generate hardware AC maps using the PET/MRI system itself, without the need for PET or medical CT scanners. The AC TX-based maps were generated for a homogeneous cylinder, made of acrylic as a validator. The technique thereafter was applied to the patient table and posterior part of an RF-phased array used in cardiovascular PET/MRI imaging. The proposed TX-based, and the CT-based, hardware maps were used in reconstructing PET images of one cardiac patient, and the results were analysed and compared. RESULTS: The LAC derived by the TX-based method for the acrylic cylinder is estimated to be 0.10851 ± 0.00380 cm-1 compared to the 0.10698 ± 0.00321 cm-1 theoretical value reported in the literature. The PET photon counts were reduced by 8.7 ± 1.1% with the patient table, at the region used in cardiac scans, while the CT-based map, used for correction, over-estimated counts by 4.3 ± 1.3%. Reconstructed in vivo images using TX-based AC hardware maps have shown 4.1 ± 0.9% mean difference compared to those reconstructed images using CT-based AC. CONCLUSIONS: The LAC of the acrylic cylinder measurements using the TX-based technique was in agreement with those in the literature confirming the validity of the technique. The over-estimation of photon counts caused by the CT-based model used for the patient table was improved by the TX-based technique. Therefore, TX-based AC of hardware using the PET/MRI system itself is possible and can produce more accurate images when compared to the CT-based hardware AC in cardiac PET images.

13.
Mol Imaging Biol ; 23(4): 516-526, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33534038

RESUMO

PURPOSE: Chemical exchange saturation transfer MRI using an infusion of glucose (glucoCEST) is sensitive to the distribution of glucose in vivo; however, whether glucoCEST is more related to perfusion or glycolysis is still debatable. We compared glucoCEST to computed tomography perfusion (CTP), [18F] fluorodeoxyglucose positron emission tomography (FDG-PET), and hyperpolarized [1-13C] pyruvate magnetic resonance spectroscopy imaging (MRSI) in a C6 rat model of glioma to determine if glucoCEST is more strongly correlated with measurements of perfusion or glycolysis. METHODS: 106 C6 glioma cells were implanted in Wistar rat brains (n = 11). CTP (including blood volume, BV; blood flow, BF; and permeability surface area product, PS) and FDG-PET standardized uptake value (SUV) were acquired at 11 to 13 days post-surgery. GlucoCEST measurements (∆CEST) were acquired the following day on a 9.4 T MRI before and after an infusion of glucose solution. This was followed by MRSI on a 3.0 T MRI after the injection of hyperpolarized [1-13C] pyruvate to generate regional maps of the lactate:pyruvate ratio (Lac:Pyr). Pearson's correlations between glucoCEST, CTP, FDG-PET, and Lac:Pyr ratio were evaluated. RESULTS: Tumors had significantly higher SUV, BV, and PS than the contralateral brain. Tumor ∆CEST was most strongly correlated with CTP measurements of BV (ρ = 0.74, P = 0.01) and PS (ρ = 0.55, P = 0.04). No significant correlation was found between glycolysis measurements of SUV or Lac:Pyr with tumor ∆CEST. PS significantly correlated with SUV (ρ = 0.58, P = 0.005) and Lac:Pyr (ρ = 0.75, P = 0.005). BV significantly correlated with Lac:Pyr (ρ = 0.57, P = 0.02), and BF significantly correlated with SUV (ρ = 0.49, P = 0.02). CONCLUSION: This study determined that glucoCEST is more strongly correlated to measurements of perfusion than glycolysis. GlucoCEST measurements have additional confounds, such as sensitivity to changing pH, that merit additional investigation.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Glucose/metabolismo , Ácido Pirúvico/metabolismo , Animais , Apoptose/fisiologia , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Proliferação de Células/fisiologia , Fluordesoxiglucose F18 , Glioma/metabolismo , Glioma/patologia , Glicólise , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Imagem Multimodal/métodos , Perfusão , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Ratos , Ratos Wistar , Tomografia Computadorizada por Raios X/métodos , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
14.
Epilepsy Res ; 172: 106583, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636504

RESUMO

OBJECTIVE: Hybrid PET/MRI may improve detection of seizure-onset zone (SOZ) in drug-resistant epilepsy (DRE), however, concerns over PET bias from MRI-based attenuation correction (MRAC) have limited clinical adoption of PET/MRI. This study evaluated the diagnostic equivalency and potential clinical value of PET/MRI against PET/CT in DRE. MATERIALS AND METHODS: MRI, FDG-PET and CT images (n = 18) were acquired using a hybrid PET/MRI and a CT scanner. To assess diagnostic equivalency, PET was reconstructed using MRAC (RESOLUTE) and CT-based attenuation correction (CTAC) to generate PET/MRI and PET/CT images, respectively. PET/MRI and PET/CT images were compared qualitatively through visual assessment and quantitatively through regional standardized uptake value (SUV) and z-score assessment. Diagnostic accuracy and sensitivity of PET/MRI and PET/CT for SOZ detection were calculated through comparison to reference standards (clinical hypothesis and histopathology, respectively). RESULTS: Inter-reader agreement in visual assessment of PET/MRI and PET/CT images was 78 % and 81 %, respectively. PET/MRI and PET/CT were strongly correlated in mean SUV (r = 0.99, p < 0.001) and z-scores (r = 0.92, p < 0.001) across all brain regions. MRAC SUV bias was <5% in most brain regions except the inferior temporal gyrus, temporal pole, and cerebellum. Diagnostic accuracy and sensitivity were similar between PET/MRI and PET/CT (87 % vs. 85 % and 83 % vs. 83 %, respectively). CONCLUSION: We demonstrate here that PET/MRI with optimal MRAC can yield similar diagnostic performance as PET/CT. Nevertheless, further exploration of the potential added value of PET/MRI is necessary before clinical adoption of PET/MRI for epilepsy imaging.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Preparações Farmacêuticas , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Imagem Multimodal , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons
15.
EJNMMI Res ; 10(1): 113, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32990808

RESUMO

BACKGROUND: Accurate and sensitive imaging biomarkers are required to study the progression of white matter (WM) inflammation in neurodegenerative diseases. Radioligands targeting the translocator protein (TSPO) are considered sensitive indicators of neuroinflammation, but it is not clear how well the expression of TSPO coincides with major histocompatibility complex class II (MHCII) molecules in WM. This study aimed to test the ability of TSPO to detect activated WM microglia that are immunohistochemically positive for MHCII in rat models of prodromal Alzheimer's disease and acute subcortical stroke. METHODS: Fischer 344 wild-type (n = 12) and TgAPP21 (n = 11) rats were imaged with [18F]FEPPA PET and MRI to investigate TSPO tracer uptake in the corpus callosum, a WM region known to have high levels of MHCII activated microglia in TgAPP21 rats. Wild-type rats subsequently received an endothelin-1 (ET1) subcortical stroke and were imaged at days 7 and 28 post-stroke before immunohistochemistry of TSPO, GFAP, iNOS, and the MHCII rat antigen, OX6. RESULTS: [18F]FEPPA PET was not significantly affected by genotype in WM and only detected increases near the ET1 infarct (P = 0.033, infarct/cerebellum uptake ratio: baseline = 0.94 ± 0.16; day 7 = 2.10 ± 0.78; day 28 = 1.77 ± 0.35). Immunohistochemistry confirmed that only the infarct (TSPO cells/mm2: day 7 = 555 ± 181; day 28 = 307 ± 153) and WM that is proximal to the infarct had TSPO expression (TSPO cells/mm2: day 7 = 113 ± 93; day 28 = 5 ± 7). TSPO and iNOS were not able to detect the chronic WM microglial activation that was detected with MHCII in the contralateral corpus callosum (day 28 OX6% area: saline = 0.62 ± 0.38; stroke = 4.30 ± 2.83; P = .029). CONCLUSION: TSPO was only expressed in the stroke-induced insult and proximal tissue and therefore was unable to detect remote and non-insult-related chronically activated microglia overexpressing MHCII in WM. This suggests that research in neuroinflammation, particularly in the WM, would benefit from MHCII-sensitive radiotracers.

16.
Radiother Oncol ; 152: 34-41, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32827589

RESUMO

BACKGROUND: PSMA-PET1 has shown good concordance with histology, but there is a need to investigate the ability of PSMA-PET to delineate DIL2 boundaries for guided biopsy and focal therapy planning. OBJECTIVE: To determine threshold and margin combinations that satisfy the following criteria: ≥95% sensitivity with max specificity and ≥95% specificity with max sensitivity. DESIGN, SETTING AND PARTICIPANTS: We registered pathologist-annotated whole-mount mid-gland prostatectomy histology sections cut in 4.4 mm intervals from 12 patients to pre-surgical PSMA-PET/MRI by mapping histology to ex-vivo imaging to in-vivo imaging. We generated PET-derived tumor volumes using boundaries defined by thresholded PET volumes from 1-100% of SUV3max in 1% intervals. At each interval, we applied margins of 0-30 voxels in one voxel increments, giving 3000 volumes/patient. OUTCOME MEASUREMENTS: Mean and standard deviation of sensitivity and specificity for cancer detection within the 2D oblique histologic planes that intersected with the 3D PET volume for each patient. RESULTS AND LIMITATIONS: A threshold of 67% SUV max with an 8.4 mm margin achieved a (mean ± std.) sensitivity of 95.0 ± 7.8% and specificity of 76.4 ± 14.7%. A threshold of 81% SUV max with a 5.1 mm margin achieved sensitivity of 65.1 ± 28.4% and specificity of 95.1 ± 5.2%. CONCLUSIONS: Preliminary evidence of thresholding and margin expansion of PSMA-PET images targeted at DILs validated with histopathology demonstrated excellent mean sensitivity and specificity in the setting of focal therapy/boosting and guided biopsy. These parameters can be used in a larger validation study supporting clinical translation.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Carga Tumoral
17.
Eur J Hybrid Imaging ; 4(1): 7, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32626841

RESUMO

BACKGROUND: Simultaneous cardiovascular imaging with positron emission tomography (PET) and magnetic resonance imaging (MRI) requires tools such as radio frequency (RF) phased arrays to achieve high temporal and spatial resolution in the MRI, as well as accurate quantification of PET. Today, high-density phased arrays (> 16 channels) used for cardiovascular PET/MRI are not designed to achieve low PET attenuation, and correcting the PET attenuation they cause requires off-line reconstruction, extra time and resources. PURPOSE: Motivated by previous work assessing the MRI performance of a novel prospectively designed 32-channel phased array, this study assessed the PET image quality with this array in place. Guided by NEMA standards, PET performance was measured using global PET counts, regional background variation (BV), contrast recovery (CR) and contrast-to-noise ratio (CNR) for both the novel array and standard arrays (mMR 12-channel and MRI 32-channel). Nonattenuation-corrected (NAC) data from all arrays (and each part of the array) were processed and compared to no-array, and relative percentage difference (RPD) of the global means was estimated and reported for each part of the arrays. Attenuation correction (AC) of PET images (water in the phantom) using two approaches, MR-based AC map (MRAC) and dual-energy CT-based map (DCTAC), was performed, and RPD compared for each part of the arrays. Percent mean attenuation within regions of interests of the phantom images from each array were compared using a two-way analysis of variance (ANOVA). RESULTS: The NAC data of the anterior part of the novel array recorded the least PET attenuation (≤ 2%); while the full novel array (anterior and posterior together) AC data, produced by MRAC and DCTAC approaches, recorded attenuation of 1.5 ± 2.9% and 0.0 ± 2.5%, respectively. The novel array PET count loss was significantly lower (p = 0.001) than those caused by the standard arrays. CONCLUSIONS: Results of this novel 32-channel cardiac array PET performance evaluation, together with its previously reported MRI performance assessment, suggest the novel array to be a strong alternative to the standard arrays currently used for cardiovascular hybrid PET/MRI imaging. It enables accurate PET quantification and high-temporal and spatial resolution for MR imaging.

18.
Eur J Hybrid Imaging ; 4(1): 10, 2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34191151

RESUMO

BACKGROUND: Hybrid PET/MRI can non-invasively improve localization and delineation of the epileptic focus (EF) prior to surgical resection in medically refractory epilepsy (MRE), especially when MRI is negative or equivocal. In this study, we developed a PET-guided diffusion tractography (PET/DTI) approach combining 18F-fluorodeoxyglucose PET (FDG-PET) and diffusion MRI to investigate white matter (WM) integrity in MRI-negative MRE patients and its potential impact on epilepsy surgical planning. METHODS: FDG-PET and diffusion MRI of 14 MRI-negative or equivocal MRE patients were used to retrospectively pilot the PET/DTI approach. We used asymmetry index (AI) mapping of FDG-PET to detect the EF as brain areas showing the largest decrease in FDG uptake between hemispheres. Seed-based WM fiber tracking was performed on DTI images with a seed location in WM 3 mm from the EF. Fiber tractography was repeated in the contralateral brain region (opposite to EF), which served as a control for this study. WM fibers were quantified by calculating the fiber count, mean fractional anisotropy (FA), mean fiber length, and mean cross-section of each fiber bundle. WM integrity was assessed through fiber visualization and by normalizing ipsilateral fiber measurements to contralateral fiber measurements. The added value of PET/DTI in clinical decision-making was evaluated by a senior neurologist. RESULTS: In over 60% of the patient cohort, AI mapping findings were concordant with clinical reports on seizure-onset localization and lateralization. Mean FA, fiber count, and mean fiber length were decreased in 14/14 (100%), 13/14 (93%), and 12/14 (86%) patients, respectively. PET/DTI improved diagnostic confidence in 10/14 (71%) patients and indicated that surgical candidacy be reassessed in 3/6 (50%) patients who had not undergone surgery. CONCLUSIONS: We demonstrate here the utility of AI mapping in detecting the EF based on brain regions showing decreased FDG-PET activity and, when coupled with DTI, could be a powerful tool for detecting EF and assessing WM integrity in MRI-negative epilepsy. PET/DTI could be used to further enhance clinical decision-making in epilepsy surgery.

19.
BMC Musculoskelet Disord ; 20(1): 182, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31039785

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) T2 and T1ρ relaxation are increasingly being proposed as imaging biomarkers potentially capable of detecting biochemical changes in articular cartilage before structural changes are evident. We aimed to: 1) summarize MRI methods of published studies investigating T2 and T1ρ relaxation time in participants at risk for but without radiographic knee OA; and 2) compare T2 and T1ρ relaxation between participants at-risk for knee OA and healthy controls. METHODS: We conducted a systematic review of studies reporting T2 and T1ρ relaxation data that included both participants at risk for knee OA and healthy controls. Participant characteristics, MRI methodology, and T1ρ and T2 relaxation data were extracted. Standardized mean differences (SMDs) were calculated within each study. Pooled effect sizes were then calculated for six commonly segmented knee compartments. RESULTS: 55 articles met eligibility criteria. There was considerable variability between scanners, coils, software, scanning protocols, pulse sequences, and post-processing. Moderate risk of bias due to lack of blinding was common. Pooled effect sizes indicated participants at risk for knee OA had lengthened T2 relaxation time in all compartments (SMDs from 0.33 to 0.74; p < 0.01) and lengthened T1ρ relaxation time in the femoral compartments (SMD from 0.35 to 0.40; p < 0.001). CONCLUSIONS: T2 and T1ρ relaxation distinguish participants at risk for knee OA from healthy controls. Greater standardization of MRI methods is both warranted and required for progress towards biomarker validation.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Cartilagem Articular/patologia , Estudos de Viabilidade , Humanos , Articulação do Joelho/patologia , Osteoartrite do Joelho/patologia
20.
J Alzheimers Dis Rep ; 3(1): 31-45, 2019 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-30842996

RESUMO

Significant advances in positron emission tomography (PET) and magnetic resonance imaging (MRI) brain imaging in the early detection of dementia indicate that hybrid PET/MRI would be an effective tool to screen for dementia in the population living with lifestyle risk factors. Here we investigate the associated costs and benefits along with the needed imaging infrastructure. A demographic analysis determined the prevalence of dementia and its incidence. The expected value of the screening program was calculated assuming a sensitivity and specificity of 0.9, a prevalence of 0.1, a QALY factor of 0.348, a willingness to pay $114,000 CAD and the cost per PET/MRI scan of $2,000 CAD. It was assumed that each head PET/MRI could screen 3,000 individuals per year. The prevalence of dementia is increasing by almost two-fold every 20 years due to the increased population at ages where dementia is more prevalent. It has been shown that a five-year delay in the incidence of dementia would decrease the prevalence by some 45%. In Canada, a five-year delay corresponds to a health care savings of $27,000 CAD per subject per year. The expected value for screening was estimated at $23,745 CAD. The number of subjects to be screened per year in Canada, USA, and China between 60 and 79 was 11,405,000. The corresponding number of head-only hybrid PET/MRI systems needed is 3,800. A brain PET/MRI screening program is financially justifiable with respect to health care costs and justifies the continuing development of MRI compatible brain PET technology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA