Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Laryngoscope ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656740

RESUMO

OBJECTIVES: Research samples that are representative of patient populations are needed to ensure the generalizability of study findings. The primary aim was to assess the efficacy of a study design and recruitment strategy in obtaining a participant sample that was representative of the broader cochlear implant (CI) patient population at the CI center. A secondary aim was to review whether the CI recipient population was representative of the state population. METHODS: Demographic variables were compared for a research participant sample (n = 79) and the CI patient population (n = 338). The participant sample was recruited from the CI patient population. The study design included visits that were at the same location and frequency as the recommended clinical follow-up intervals. The demographics for the combined group (participant sample and patient population) were then compared to the reported demographics for the population in North Carolina. RESULTS: There were no significant differences between the participant sample and patient population for biological sex, age at implantation, racial distribution, socioeconomic position, degree of urbanization, or drive time to the CI center (p ≥ 0.086). The combined CI recipient population was significantly different from the North Carolina population for the distributions of race, ethnicity, and degree of urbanization (p < 0.001). CONCLUSION: The study design and recruitment strategy allowed for recruitment of a participant sample that was representative of the CI patient population. Disparities in access to cochlear implantation persist, as supported by the significant differences in the combined CI recipient population and the population for our state. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

2.
Cochlear Implants Int ; : 1-6, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353257

RESUMO

OBJECTIVES: Children with cochlear nerve deficiency (CND) have wide variability in outcomes with cochlear implant (CI) use. The current study aims to report a large cohort of pediatric CI recipients with CND and to evaluate for factors that may predict improved performance. METHODS: The current study is a retrospective review of pediatric CI recipients with CND at a tertiary academic hospital. Variables including cochlear nerve status (hypoplasia vs aplasia), age at implantation, cochleovestibular malformation, bony cochlear nerve aperture, internal auditory canal aperture, and cognitive delay were evaluated for predictors of postoperative performance. A stepwise multinomial regression analysis was performed. RESULTS: Forty-seven CI recipients (54 ears) were included in the analysis. A majority (59%) showed auditory capabilities with their CI. Twenty percent of recipients achieved some level of open-set speech perception with their CI. The regression analysis identified cochlear nerve status and cognitive delay as predictors of performance. CI recipients with cochlear nerve hypoplasia had significantly improved performance compared to those with aplasia (p = 0.003). Recipients with cognitive delay had more limited benefit than those without cognitive delay (p = 0.033). CONCLUSIONS: Children with CND can benefit from CI use, with outcomes spanning from non-use to development of spoken language. Predictive factors for improved performance include a lack of cognitive delay and cochlear hypoplasia rather than aplasia. These can be important considerations for parent counseling and decision making.

3.
Laryngoscope ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345081

RESUMO

OBJECTIVE: The study was conducted to evaluate the safety and efficacy of mild internal jugular (IJV) compression via an FDA approved compression collar for symptomatic treatment of venous pulsatile tinnitus. METHODS: This is a prospective study that recruited 20 adult patients with venous pulsatile tinnitus. Participants completed the Tinnitus Handicap Inventory (THI), were fitted with the collar, and rated symptom intensity on a 10-point tinnitus intensity scale before and during collar use. Once weekly for 4 weeks, they answered a survey quantifying days used, average tinnitus intensity before and after wearing the collar each day of use, and any safety concerns. Lastly, they completed an exit interview. The primary outcome was symptomatic relief, with secondary outcomes of safety, effect of treatment setting, effect of time, and quality of life assessed via nonparametric testing. RESULTS: 18 participants completed the study, and 276 paired daily before use/during use intensity scores were submitted. The median symptom intensity without the collar was 6 (IQR 4, 7), whereas with the collar it was 3 (IQR 2, 5), for a median symptomatic relief of 50%. The collar had a significant effect in reducing symptom intensity (p < 0.0001) and burden of illness via the THI (p < 0.0001). There was no effect of setting, frequency, or time on symptomatic relief with the collar. There were no adverse safety events reported aside from minor discomfort upon initial application. CONCLUSIONS: Venous compression collars offer acute symptom relief for patients with venous pulsatile tinnitus. Further study is needed to assess safety and efficacy of longitudinal use. LEVEL OF EVIDENCE: 4 Laryngoscope, 2024.

4.
Laryngoscope ; 134(4): 1868-1873, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37767794

RESUMO

OBJECTIVE: Determine variables that influence post-activation performance for cochlear implant (CI) recipients who lost low-frequency acoustic hearing. METHODS: A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low-frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI-alone device. Performance scores were queried from the 1, 3, 6, 12, and 24-month post-activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low-frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone. RESULTS: 113 patients met the inclusion criteria. There was a significant main effect of interval (p < 0.001), indicating improved word recognition post-activation despite loss of residual hearing. There were significant main effects of age (p = 0.029) and array length (p = 0.038), with no effect of preoperative low-frequency hearing (p = 0.171). There was a significant 2-way interaction between age and array length (p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost. CONCLUSION: CI recipients with preoperative functional low-frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance-despite the loss of low-frequency hearing. Age and electrode array length may play a role in post-activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1868-1873, 2024.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Idoso , Percepção da Fala/fisiologia , Audição , Testes Auditivos , Resultado do Tratamento
5.
Laryngoscope ; 134(5): 2401-2404, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38149671

RESUMO

OBJECTIVE: To detail a modified surgical technique for implantation of the Osia 2 Bone Conduction Hearing Aid (BCHA) system and to assess intra- and postoperative outcomes of this technique. METHODS: A retrospective review was performed for cases undergoing implantation of an Osia 2 BCHA at a tertiary academic medical center. Modifications were made to the surgical procedure including: horizontal or curvilinear incisions, placement of the osseointegrated screw slightly superior to the plane of the external auditory canal, and double layer wound closure. Data regarding outcomes including demographics, incision type, surgical time, drilling requirements, and complications were collected using the electronic medical record. RESULTS: A total of twenty-eight cases were evaluated with 57.1% and 42.9% utilizing horizontal and curved incisions, respectively. The median age for recipients was 43.1 years with six pediatric cases included in the study. Median operative time was 58 min (43-126 min). The majority of cases required minimal (60.7%) or no drilling (28.6%) with a significant increase in operative time for those requiring moderate drilling versus minimal to no drilling (F = 8.02, p = 0.002). There were no intraoperative complications. One (3.6%) postoperative seroma occurred which resolved with conservative management. CONCLUSION: The proposed modified surgical technique is a safe and effective method for implantation of the transcutaneous BCHA system with a low complication rate. Keys include incision design, implant placement, and two-layered closure to minimize wound tension. These modifications can improve ease of the procedure and reduce operative time. These techniques also appear to be applicable to the pediatric population. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:2401-2404, 2024.


Assuntos
Condução Óssea , Auxiliares de Audição , Humanos , Criança , Adulto , Implantação de Prótese/métodos , Meato Acústico Externo/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/reabilitação
6.
Otol Neurotol ; 44(10): 1004-1010, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37758328

RESUMO

OBJECTIVES: To investigate the incidence of electrode contacts within the functional acoustic hearing region in cochlear implant (CI) recipients and to assess its influence on speech recognition for electric-acoustic stimulation (EAS) users. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: One hundred five CI recipients with functional acoustic hearing preservation (≤80 dB HL at 250 Hz). INTERVENTIONS: Cochlear implantation with a 24-, 28-, or 31.5-mm lateral wall electrode array. MAIN OUTCOME MEASURES: Angular insertion depth (AID) of individual contacts was determined from imaging. Unaided acoustic thresholds and AID were used to calculate the proximity of contacts to the functional acoustic hearing region. The association between proximity values and speech recognition in quiet and noise for EAS users at 6 months postactivation was reviewed. RESULTS: Sixty percent of cases had one or more contacts within the functional acoustic hearing region. Proximity was not significantly associated with speech recognition in quiet. Better performance in noise was observed for cases with close correspondence between the most apical contact and the upper edge of residual hearing, with poorer results for increasing proximity values in either the basal or apical direction ( r14 = 0.48, p = 0.043; r18 = -0.41, p = 0.045, respectively). CONCLUSION: There was a high incidence of electrode contacts within the functional acoustic hearing region, which is not accounted for with default mapping procedures. The variability in outcomes across EAS users with default maps may be due in part to electric-on-acoustic interference, electric frequency-to-place mismatch, and/or failure to stimulate regions intermediate between the most apical electrode contact and the functional acoustic hearing region.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Implantes Cocleares/efeitos adversos , Implante Coclear/métodos , Estimulação Acústica/métodos , Percepção da Fala/fisiologia , Incidência , Audição , Estimulação Elétrica/métodos
8.
Laryngoscope ; 133(12): 3540-3547, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37078508

RESUMO

OBJECTIVE: Comparison of acute speech recognition for cochlear implant (CI) alone and electric-acoustic stimulation (EAS) users listening with default maps or place-based maps using either a spiral ganglion (SG) or a new Synchrotron Radiation-Artificial Intelligence (SR-AI) frequency-to-place function. METHODS: Thirteen adult CI-alone or EAS users completed a task of speech recognition at initial device activation with maps that differed in the electric filter frequency assignments. The three map conditions were: (1) maps with the default filter settings (default map), (2) place-based maps with filters aligned to cochlear SG tonotopicity using the SG function (SG place-based map), and (3) place-based maps with filters aligned to cochlear Organ of Corti (OC) tonotopicity using the SR-AI function (SR-AI place-based map). Speech recognition was evaluated using a vowel recognition task. Performance was scored as the percent correct for formant 1 recognition due to the rationale that the maps would deviate the most in the estimated cochlear place frequency for low frequencies. RESULTS: On average, participants had better performance with the OC SR-AI place-based map as compared to the SG place-based map and the default map. A larger performance benefit was observed for EAS users than for CI-alone users. CONCLUSION: These pilot data suggest that EAS and CI-alone users may experience better performance with a patient-centered mapping approach that accounts for the variability in cochlear morphology (OC SR-AI frequency-to-place function) in the individualization of the electric filter frequencies (place-based mapping procedure). LEVEL OF EVIDENCE: 3 Laryngoscope, 133:3540-3547, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Inteligência Artificial , Cóclea/anatomia & histologia , Estimulação Acústica/métodos
9.
Laryngoscope ; 133(10): 2792-2797, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36757052

RESUMO

OBJECTIVES: Assess the long-term patterns of perceived tinnitus severity and subjective benefit for adult cochlear implant (CI) users with asymmetric or unilateral hearing loss (AHL or UHL). METHODS: Forty adults underwent cochlear implantation as part of a prospective clinical trial assessing the outcomes of CI use in cases of AHL (n = 20) and UHL (n = 20). Subjective measures included the Tinnitus Handicap Inventory (THI), the Speech, Spatial, & Qualities of Hearing Scale (SSQ), and the Abbreviated Profile of Hearing Aid Benefit (APHAB). Responses were obtained preoperatively and at routine intervals out to 5 years post-activation. RESULTS: For subjective benefit, participants with AHL and UHL reported a significant improvement as compared to preoperative abilities, which was maintained with long-term CI use. For perceived tinnitus severity, participants with AHL and UHL reported a significant reduction with CI use as compared to preoperative perceptions. The perceived tinnitus severity significantly differed for the AHL and UHL cohorts over time. This pattern of results is likely influenced by the worse perceived severity levels for the UHL cohort preoperatively and the fluctuating perceived severity levels for some participants in the AHL cohort post-activation. CONCLUSION: Adults with AHL and UHL report an early, significant reduction in perceived tinnitus severity and improvement in quality of life with CI use that is generally maintained with long-term device use. Questionnaires such as the THI, SSQ, and APHAB may contribute to a more holistic assessment of the benefits of cochlear implantation in this population. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:2792-2797, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Zumbido , Adulto , Humanos , Implante Coclear/métodos , Perda Auditiva/cirurgia , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação , Estudos Prospectivos , Qualidade de Vida , Percepção da Fala/fisiologia , Zumbido/cirurgia , Resultado do Tratamento
10.
Laryngoscope ; 133(6): 1480-1485, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36053850

RESUMO

OBJECTIVE: To assess long-term binaural hearing abilities for cochlear implant (CI) users with unilateral hearing loss (UHL) or asymmetric hearing loss (AHL). METHODS: A prospective, longitudinal, repeated measures study was completed at a tertiary referral center evaluating adults with UHL or AHL undergoing cochlear implantation. Binaural hearing abilities were assessed with masked speech recognition tasks using AzBio sentences in a 10-talker masker. Performance was evaluated as the ability to benefit from spatial release from masking (SRM). SRM was calculated as the difference in scores when the masker was presented toward the CI-ear (SRMci ) or the contralateral ear (SRMcontra ) relative to the co-located condition (0°). Assessments were completed pre-operatively and at annual intervals out to 5 years post-activation. RESULTS: Twenty UHL and 19 AHL participants were included in the study. Linear Mixed Models showed significant main effects of interval and group for SRMcontra . There was a significant interaction between interval and group, with UHL participants reaching asymptotic performance early and AHL participants demonstrating continued growth in binaural abilities to 5 years post-activation. The improvement in SRM showed a significant positive correlation with contralateral unaided hearing thresholds (p = 0.050) as well as age at implantation (p = 0.031). CONCLUSIONS: CI recipients with UHL and AHL showed improved SRM with long-term device use. The time course of improvement varied by cohort, with the UHL cohort reaching asymptotic performance early and the AHL cohort continuing to improve beyond 1 year. Differences between cohorts could be driven by differences in age at implantation as well as contralateral unaided hearing thresholds. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:1480-1485, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Adulto , Humanos , Estudos Prospectivos , Audição , Perda Auditiva/cirurgia , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/reabilitação
11.
Curr Opin Otolaryngol Head Neck Surg ; 30(5): 303-308, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36004791

RESUMO

PURPOSE OF REVIEW: Children and adults with unilateral or asymmetric hearing loss (UHL/AHL) have poorer spatial hearing (e.g. speech understanding in complex maskers and localization) and quality of life compared with peers with normal hearing bilaterally. Patients with UHL/AHL experience limited benefits with contralateral-routing technologies (e.g. bone conduction, CROS hearing aid systems). Cochlear implantation allows for stimulation of the auditory pathway for the poorer hearing ear. The present study reviews the recent literature on outcomes of cochlear implant use for recipients with UHL/AHL. RECENT FINDINGS: Recent research corroborates previous investigations of the significant benefits on measures of spatial hearing, tinnitus severity and quality of life for adult cochlear implant recipients. These benefits are also observed in pediatric cochlear implant recipients, with an association of better outcomes with younger ages at implantation for congenital cases and shorter durations of UHL/AHL for acquired cases. In addition, randomized trials demonstrate better outcomes with cochlear implant use versus contralateral-routing technologies. SUMMARY: Cochlear implantation supports better spatial hearing and quality of life in children and adults with UHL/AHL as compared to alternative listening conditions. Current research supports the expansion of candidacy criteria and insurance coverage for cochlear implantation for patients with UHL/AHL to improve their binaural hearing.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Adulto , Criança , Humanos , Qualidade de Vida , Resultado do Tratamento
12.
Otol Neurotol ; 43(7): e726-e729, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35820072

RESUMO

OBJECTIVES: Review the effectiveness of an alternative mapping procedure of a precurved electrode array in the internal auditory canal (IAC). DESIGN: A 7-year-old bilateral cochlear implant (CI) recipient of precurved arrays transferred to the study site and demonstrated no speech recognition with the left CI. Imaging revealed bilateral incomplete partition type III malformations. For the left CI, four contacts were observed in the basal cochlear turn and 18 contacts were coiled in the IAC. The family decided against revision surgery. Pitch ranking was completed to map the contacts in the IAC that were perceptually discrete and tonotopically organized. RESULTS: For the left CI, PB-K word recognition improved from no recognition to 32% after 1 month and to 52% after 3 months. In the bilateral CI condition, performance improved from 56 to 72% after 1 month and 80% after 3 months. CONCLUSION: A precurved array in the IAC creates difficult management decisions. Direct stimulation of the auditory nerve resulted in better monaural and bilateral speech recognition, likely due to better spectral representation of the speech signal. Individualizing the map using imaging and behavioral findings may improve performance for malpositioned arrays when revision surgery is not pursued.


Assuntos
Implante Coclear , Implantes Cocleares , Orelha Interna , Percepção da Fala , Criança , Implante Coclear/métodos , Nervo Coclear/fisiologia , Orelha Interna/diagnóstico por imagem , Orelha Interna/cirurgia , Humanos , Fala
13.
Audiol Neurootol ; 27(6): 437-448, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35439753

RESUMO

INTRODUCTION: Cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear experience a significant improvement in sound source localization when listening with the CI in combination with their NH-ear (CI + NH) as compared to with the NH-ear alone. The improvement in localization is primarily due to sensitivity to interaural level differences (ILDs). Sensitivity to interaural timing differences (ITDs) may be limited by auditory aging, frequency-to-place mismatches, the signal coding strategy, and duration of CI use. The present report assessed the sensitivity of ILD and ITD cues in CI + NH listeners who were recipients of long electrode arrays that provide minimal frequency-to-place mismatches and were mapped with a coding strategy that presents fine structure cues on apical channels. METHODS: Sensitivity to ILDs and ITDs for localization was assessed using broadband noise (BBN), as well as high-pass (HP) and low-pass (LP) filtered noise for adult CI + NH listeners. Stimuli were 200-ms noise bursts presented from 11 speakers spaced evenly over an 180° arc. Performance was quantified in root-mean-squared error and response patterns were analyzed to evaluate the consistency, accuracy, and side bias of the responses. Fifteen listeners completed the task at the 2-year post-activation visit; seven listeners repeated the task at a later annual visit. RESULTS: Performance at the 2-year visit was best with the BBN and HP stimuli and poorer with the LP stimulus. Responses to the BBN and HP stimuli were significantly correlated, consistent with the idea that CI + NH listeners primarily use ILD cues for localization. For the LP stimulus, some listeners responded consistently and accurately and with limited side bias, which may indicate sensitivity to ITD cues. Two of the 7 listeners who repeated the task at a later annual visit experienced a significant improvement in performance with the LP stimulus, which may indicate that sensitivity to ITD cues may improve with long-term CI use. CONCLUSIONS: CI recipients with a NH-ear primarily use ILD cues for sound source localization, though some may use ITD cues as well. Sensitivity to ITD cues may improve with long-term CI listening experience.


Assuntos
Implante Coclear , Implantes Cocleares , Localização de Som , Estimulação Acústica , Localização de Som/fisiologia , Audição
14.
Laryngoscope ; 132(12): 2453-2458, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35174886

RESUMO

OBJECTIVES/HYPOTHESIS: To assess whether early, significant improvements in sound source localization observed in cochlear implant (CI) recipients with normal hearing (NH) in the contralateral ear are maintained after 5 years of CI use. STUDY DESIGN: Prospective, repeated measures study. METHODS: Participants were recruited from a sample of CI + NH listeners (n = 20) who received their device as part of a prospective clinical trial investigating outcomes of CI use for adult cases of single-sided deafness. Sound source localization was assessed annually after the clinical trial endpoint (1-year post-activation). Listeners were asked to indicate the perceived sound source for a broadband noise burst presented randomly at varied intensity levels from one of 11 speakers along a 180° arc. Performance was quantified as root-mean-squared (RMS) error. RESULTS: Linear mixed models showed superior post-activation performance was maintained with long-term CI use as compared to preoperative abilities (P < .001). Unexpectedly, a significant improvement (P = .009) in sound source localization was observed over the long-term post-activation period (1-5 years). To better understand these long-term findings, the response patterns for the 11 participants who were evaluated at the 1- and 5-year visits were reviewed. This subgroup demonstrated a significant improvement in RMS error (P = .020) and variable error (P = .031), indicating more consistent responses at the 5-year visit. CONCLUSION: Adult CI + NH listeners experience significant improvements in sound source localization within the initial weeks of listening experience, with additional improvements observed after long-term device use. The present sample demonstrated significant improvements between the 1-year and 5-year visits, with greater accuracy and consistency noted in their response patterns. LEVEL OF EVIDENCE: 3 Laryngoscope, 132:2453-2458, 2022.


Assuntos
Implante Coclear , Surdez , Localização de Som , Adulto , Humanos , Implantes Cocleares , Surdez/cirurgia , Surdez/reabilitação , Estudos Prospectivos , Localização de Som/fisiologia , Ensaios Clínicos como Assunto
15.
Otol Neurotol ; 42(9): e1234-e1241, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34224547

RESUMO

OBJECTIVE: Assess the influence of cochlear implant (CI) use on the perceived listening effort of adult and pediatric subjects with unilateral hearing loss (UHL) or asymmetric hearing loss (AHL). STUDY DESIGN: Prospective cohort. SETTING: Tertiary referral center. PATIENTS: Adults and children with UHL or AHL. INTERVENTION: Cochlear implantation. Subjects received their CI as part of a clinical trial assessing the effectiveness of cochlear implantation in cases of UHL and AHL. MAIN OUTCOME MEASURES: Responses to the Listening Effort pragmatic subscale on the Speech, Spatial, and Qualities of Hearing Scale (SSQ) or SSQ for Children with Impaired Hearing (SSQ-C) were compared over the study period. Subjects or their parents completed the questionnaires preoperatively and at predetermined postactivation intervals. For the adult subjects, responses were compared to word recognition in quiet and sentence recognition in noise. RESULTS: Forty adult subjects (n = 20 UHL, n = 20 AHL) and 16 pediatric subjects with UHL enrolled and underwent cochlear implantation. Subjects in all three groups reported a significant reduction in perceived listening effort within the initial months of CI use (p < 0.001; η2 ≥ 0.351). The perceived benefit was significantly correlated with speech recognition in noise for the adult subjects with UHL at the 12-month interval (r(20) = .59, p = 0.006). CONCLUSIONS: Adult and pediatric CI recipients with UHL or AHL report a reduction in listening effort with CI use as compared to their preoperative experiences. Use of the SSQ and SSQ-C Listening Effort pragmatic subscale may provide additional information about a CI recipient's experience beyond the abilities measured in the sound booth.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Perda Auditiva , Percepção da Fala , Adulto , Criança , Perda Auditiva Unilateral/cirurgia , Humanos , Estudos Prospectivos , Resultado do Tratamento
16.
Otol Neurotol ; 42(1): 203-206, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33885268

RESUMO

HYPOTHESIS/OBJECTIVE: Investigate the rate of hearing loss progression and incidence of cochlear implant candidacy in children with enlarged vestibular aqueduct (EVA). BACKGROUND: EVA is the most common congenital malformation of the inner ear, is responsible for a large percentage of children with hearing loss, and is associated with hearing loss progression. Rates and degree of progression of hearing loss to cochlear implantation candidacy have not been well described. METHODS: Review of children with EVA who presented to a single academic medical center. Audiometric data were reviewed to determine subjects who met criteria for cochlear implantation (≥75 dB pure-tone average) at presentation. For those not meeting criteria, serial audiometric data were reviewed for progression to candidacy. RESULTS: A total of 257 ears met inclusion criteria. One hundred ninety-two (74.7%) met cochlear implant candidacy criteria by age 12, yet only 117 ears (60.9%) actually received implants before turning 13. One hundred fifty-three ears (59.5%) met implant candidacy criteria at presentation. Nearly 50% of those not initially meeting implantation criteria had a ≥15 dB shift in pure-tone average by age 12, with 37.5% of this subgroup meeting implant candidacy criteria before their teen years at an average age of 7.10 years. CONCLUSION: The majority of children with EVA reach cochlear implant candidacy before reaching adulthood, yet implantation rates for candidate ears remain at 60% and delay in implantation persist. Parents of children with EVA should be counseled on the likelihood of progression and closely monitored for cochlear implant candidacy.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Aqueduto Vestibular , Adolescente , Adulto , Criança , Audição , Perda Auditiva Neurossensorial/cirurgia , Humanos , Estudos Retrospectivos , Aqueduto Vestibular/anormalidades , Aqueduto Vestibular/diagnóstico por imagem , Aqueduto Vestibular/cirurgia
17.
Int J Pediatr Otorhinolaryngol ; 140: 110550, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33316760

RESUMO

OBJECTIVE: (s): Patient-reported outcome measures (PROMs) are tools that allow patients to directly share information about their health with their healthcare provider. Health literacy experts recommend that health information, such as PROMs, be written at a 6th grade level to ensure patients can read and comprehend it. As the readability of PROMs used in pediatric otolaryngology has yet to be studied, our goal was to analyze the readability of these PROMs and assess their compliance with readability recommendations. METHODS: The Gunning Fog, the Simple Measure of Gobbledygook (SMOG), and the FORCAST readability formulas were used to determine the readability of disease-specific PROMs for pediatric otolaryngology. RESULTS: Fourteen PROMs were reviewed in the study. Most were intended for caregiver completion (n = 13, 92.9%). Ten PROMs when measured by Gunning Fog (71.4%), 2 PROMs when measured by SMOG (14.3%), and 0 PROMs when measured by FORCAST (0.0%) were at or below the 6th grade reading level. CONCLUSION: Most PROMs available for use in pediatric otolaryngology are above the recommended 6th grade reading level when measured by FORCAST, the most appropriate metric for assessing questionnaires. The high reading grade level needed to complete these PROMs can contribute to health disparities among underserved and vulnerable populations, such as children. Pediatric otolaryngology PROMs developed in the future should take readability into account in order to ensure equity in the delivery of care.


Assuntos
Letramento em Saúde , Otolaringologia , Criança , Compreensão , Humanos , Internet , Medidas de Resultados Relatados pelo Paciente , Inquéritos e Questionários
18.
Nature ; 585(7825): 379-382, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32939065

RESUMO

The field of plasmonics, which studies the resonant interactions of electromagnetic waves and free electrons in solid-state materials1, has yet to be put to large-scale commercial application2 owing to the large amount of loss that usually occurs in plasmonic materials3. Organic light-emitting devices (OLEDs)4-7 have been incorporated into billions of commercial products because of their good colour saturation, versatile form factor8 and low power consumption9, but could still be improved in terms of efficiency and stability. Although OLEDs incorporating organic phosphors achieve an internal charge-to-light conversion of unity10, their refractive index contrast reduces the observable fraction of photons outside the device to around 25 per cent11-13. Further, during OLED operation, a localized buildup of slow-decaying14 triplet excitons and charges15 gradually reduces the brightness of the device in a process called ageing16,17, which can result in 'burn-in' effects on the display. Simultaneously improving device efficiency and stability is of paramount importance for OLED technology. Here we demonstrate an OLED that uses the decay rate enhancement18 of a plasmonic system to increase device stability, while maintaining efficiency by incorporating a nanoparticle-based out-coupling scheme to extract energy from the plasmon mode. Using an archetypal phosphorescent emitter, we achieve a two-fold increase in operational stability at the same brightness as a reference conventional device while simultaneously extracting 16 per cent of the energy from the plasmon mode as light. Our approach to increasing OLED stability avoids material-specific designs19-22 and is applicable to all commercial OLEDs that are currently used for lighting panels, televisions and mobile displays.

19.
Trends Hear ; 24: 2331216520945524, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32808881

RESUMO

A prospective clinical trial evaluated the effectiveness of cochlear implantation in adults with asymmetric hearing loss (AHL). Twenty subjects with mild-to-moderate hearing loss in the better ear and moderate-to-profound hearing loss in the poorer ear underwent cochlear implantation of the poorer hearing ear. Subjects were evaluated preoperatively and at 1, 3, 6, 9, and 12 months post-activation. Preoperative performance was evaluated unaided, with traditional hearing aids (HAs) or with a bone-conduction HA. Post-activation performance was evaluated with the cochlear implant (CI) alone or in combination with a contralateral HA (bimodal). Test measures included subjective benefit, word recognition, and spatial hearing (i.e., localization and masked sentence recognition). Significant subjective benefit was reported as early as the 1-month interval, indicating better performance with the CI compared with the preferred preoperative condition. Aided word recognition with the CI alone was significantly improved at the 1-month interval compared with preoperative performance with an HA and continued to improve through the 12-month interval. Subjects demonstrated early, significant improvements in the bimodal condition on the spatial hearing tasks compared with baseline preoperative performance tested unaided. The magnitude of the benefit was reduced for subjects with AHL when compared with published data on CI users with normal hearing in the contralateral ear; this finding may reflect significant differences in age at implantation and hearing sensitivity across cohorts.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Perda Auditiva , Localização de Som , Percepção da Fala , Adulto , Perda Auditiva/diagnóstico , Perda Auditiva/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
20.
Otol Neurotol ; 41(6): e686-e694, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32569244

RESUMO

BACKGROUND: Angular insertion depth (AID) of the electrode array provides valuable information regarding intracochlear positioning, which can be used to predict outcomes and optimize performance. While computed tomography (CT) offers high-resolution imaging, there is a need to develop technology to accurately determine AID from intraoperative x-rays acquired at unknown angles. METHODS: An algorithm was developed using a three-dimensional model of the scala tympani to estimate AID from an x-ray acquired at an unknown angle. The model is manipulated over the x-ray until the projection angle is inferred and the location of the round window and individual electrode contacts are identified. Validation of the algorithm involved 1) assessing accuracy with deviation from cochlear view by comparing AID determined with simulated x-rays to those determined with CT in a temporal bone model, and 2) assessing reproducibility in the clinical setting, by comparing intra- and inter-rater reliability with intraoperative x-ray in cochlear implant (CI) recipients, which were subsequently compared to AID determined with postoperative CT. RESULTS: Estimates of AID from x-rays were generally within 10 degrees of CT regardless of deviation from cochlear view. Excluding two outliers with poor imaging quality, the intraclass correlation coefficients for intra- and inter-rater reliability were excellent (0.991 and 0.980, respectively). CONCLUSION: With intraoperative x-rays of sufficient quality, the helical scala tympani model can be used to accurately and reliably determine AID without the need to specify a preferred image angle. The application can therefore be used in most CI recipients when a postoperative CT is not available.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Humanos , Reprodutibilidade dos Testes , Rampa do Tímpano/diagnóstico por imagem , Rampa do Tímpano/cirurgia , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA