Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Nat Commun ; 14(1): 7046, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949859

RESUMO

Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

2.
Phys Rev Lett ; 128(18): 185002, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35594117

RESUMO

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr Heß spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

3.
Rev Sci Instrum ; 92(5): 053102, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243250

RESUMO

We report the development of a high-resolution spectrometer for extended x-ray absorption fine structure (EXAFS) studies of materials under extreme conditions. A curved crystal and detector in the spectrometer are replaceable such that a single body is employed to perform EXAFS measurements at different x-ray energy intervals of interest. Two configurations have been implemented using toroidal crystals with Ge 311 reflection set to provide EXAFS at the Cu K-edge (energy range 8.9-9.8 keV) and Ge 400 reflection set to provide EXAFS at the Ta L3-edge (9.8-10.7 keV). Key performance characteristics of the spectrometer were found to be consistent with design parameters. The data generated at the National Ignition Facility have shown an ≃3 eV spectral resolution for the Cu K-edge configuration and ≃6 eV for the Ta L3-edge configuration.

4.
Rev Sci Instrum ; 92(4): 043531, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243385

RESUMO

This paper describes a new class of focusing crystal forms for the x-ray Bragg crystal spectroscopy of small, point-like, x-ray sources. These new crystal forms are designed with the aid of sinusoidal spirals, a family of curves, whose shapes are defined by only one parameter, which can assume any real value. The potential of the sinusoidal spirals for the design x-ray crystal spectrometers is demonstrated with the design of a toroidally bent crystal of varying major and minor radii for measurements of the extended x-ray absorption fine structure near the Ta-L3 absorption edge at the National Ignition Facility.

6.
Rev Sci Instrum ; 90(1): 013506, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709229

RESUMO

The sensitivity of Fuji SR and MS image plates (IPs) used in x-ray spectrometers on OMEGA and the National Ignition Facility has been measured using two techniques. A set of radioisotopes has been used to constrain image-plate sensitivity between 6 and 60 keV, while a Manson source has been used to expose image plates to x rays at energies between 1.5 and 8 keV. These data have shown variation in sensitivity on the order of 5% for a given IP type and scanner settings. The radioisotope technique has also been used to assess IP fading properties for MS-type plates over long times. IP sensitivity as a function of scanner settings and pixel size has been systematically examined, showing variations of up to a factor of 2 depending on the IP type. Cross-calibration of IP scanners at different facilities is necessary to produce a consistent absolute sensitivity curve spanning the energy range of 2-60 keV.

7.
Rev Sci Instrum ; 90(12): 125113, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893795

RESUMO

The use of x-ray diffraction (XRD) measurements in laser-driven dynamic compression experiments at high-power laser facilities is becoming increasingly common. Diffraction allows one to probe in situ the transformations occurring at the atomic level at extreme conditions of pressure, temperature, and time scale. In these measurements, the x-ray source is generated by irradiation of a solid foil. Under certain laser drive conditions, quasimonochromatic He-α radiation is generated. Careful analysis of the x-ray source plasma spectra reveals that this radiation is not a single line emission and that monochromaticity is highly dependent on the laser irradiance. In this work, we analyze how the spectra emitted by laser-irradiated copper, germanium, and iron foils at the Omega Laser vary depending on different laser drive conditions and discuss the implications for XRD experiments.

8.
Rev Sci Instrum ; 89(10): 10F119, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399669

RESUMO

At large laser faculties, such as OMEGA and the National Ignition Facility (NIF), x-ray spectrometers are provided by the facility to diagnose plasma conditions or monitor backlighters. Often the calibration of these spectrometers is unknown or out of date. As a remedy to this situation, we present a simple ray trace method to calibrate flat crystal spectrometers using only basic information regarding the optical design of the spectrometer. This model is then used to output photometric throughput estimates, dispersion, solid angle, and spectral resolution estimates. This model is applied to the mono angle crystal spectrometer and Super Snout I at the NIF and the X-Ray Spectrometer at the OMEGA laser facility.

9.
Rev Sci Instrum ; 89(10): 10F118, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399766

RESUMO

The here-described spectrometer was developed for the extended x-ray absorption fine structure spectroscopy of high-density plasmas at the National Ignition Facility. It employs as the Bragg reflecting element a new type of toroidally bent crystal with a constant and very large major radius R and a much smaller, locally varying, minor radius r. The focusing properties of this crystal and the experimental arrangement of the source and detector make it possible to (a) fulfill the conditions for a perfect imaging of an ideal point source for each wavelength, (b) obtain a high photon throughput, (c) obtain a high spectral resolution by eliminating the effects of source-size broadening, and (d) obtain a one-dimensional spatial resolution with a high magnification perpendicular to the main dispersion plane.

10.
Rev Sci Instrum ; 89(10): 10F125, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399848

RESUMO

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr Heα, Lyα, and Heß complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von Hámos crystal that time-integrates the Kr Heα, Heß and intervening energy range provides in situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

11.
Rev Sci Instrum ; 89(10): 10G108, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399872

RESUMO

In the quest for reaching ignition of deuterium-tritium (DT) fuel capsule implosions, experiments on the National Ignition Facility (NIF) have shown lower final fuel areal densities than simulated. Possible explanations for reduced compression are higher preheat that can increase the ablator-DT ice density jump and induce mix at that interface or reverberating shocks. We are hence developing x-ray Refraction Enhanced Radiography (RER) to infer the inflight density profiles in layered fuel capsule implosions. We use a 5 µm slit backlit by a Ni 7.8 keV He-α NIF laser driven x-ray source positioned at 20 mm from the capsule to cast refracted images of the inflight capsule onto a streak camera in a high magnification (M ∼ 60×) setup. Our first experiments have validated our setup that recorded a streaked x-ray fringe pattern from an undriven high density carbon (HDC) capsule consistent with ray tracing calculations at the required ∼6 µm and 25 ps resolution. Streaked RER was then applied to inflight layered HDC capsule implosions using a hydrogen-tritium fuel mix rather than DT to reduce neutron yields and associated backgrounds. The first RER of an imploding capsule revealed strong features associated with the ablation front and ice-ablator interface that are not visible in standard absorption radiographs.

12.
Rev Sci Instrum ; 89(10): 10F114, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399955

RESUMO

Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for in situ characterization of matter in the high energy density regime. An EXAFS platform is currently being developed on the National Ignition Facility. Development of a suitable X-ray backlighter involves minimizing the temporal duration and source size while maximizing spectral smoothness and brightness. One approach involves imploding a spherical shell, which generates a high-flux X-ray flash at stagnation. We present results from a series of experiments comparing the X-ray source properties produced by imploded empty and Ar-filled capsules.

13.
Rev Sci Instrum ; 89(10): 10F123, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399981

RESUMO

At the National Ignition Facility (NIF), storage phosphor image plates (IP) are used extensively for recording x-rays, charged particles, and neutrons. For x-ray imaging and spectroscopy, absolute and relative calibrations are important for extracting plasma information from the diagnostics. We use Fuji MS, SR, and TR image plates that have been cut to fit custom diagnostic envelopes. The image plates are scanned on a General Electric FLA 7000 IP flying spot scanner. Calibrations for sensitivity, spatial scale, and temperature dependent fade are applied. During a set of recent calibrations, we noticed large shifts in the absolute calibration of the image plate system. The possible source of these shifts is discussed. We discuss scanner stability and a method for calibration. We discuss the fade and temperature effects of the image plates and how this correction is applied within the NIF environment. We also compare our NIF GE FLA 7000 IP scanner with a new General Electric Amersham Typhoon IP scanner.

14.
Phys Rev Lett ; 121(9): 095002, 2018 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-30230893

RESUMO

We report on the first multilocation electron temperature (T_{e}) and flow measurements in an ignition hohlraum at the National Ignition Facility using the novel technique of mid-Z spectroscopic tracer "dots." The measurements define a low resolution "map" of hohlraum plasma conditions and provide a basis for the first multilocation tests of particle and energy transport physics in a laser-driven x-ray cavity. The data set is consistent with classical heat flow near the capsule but reduced heat flow near the laser entrance hole. We evaluate the role of kinetic effects, self-generated magnetic fields, and instabilities in causing spatially dependent heat transport in the hohlraum.

15.
Rev Sci Instrum ; 88(8): 083907, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28863696

RESUMO

Extended X-ray absorption Fine Structure (EXAFS) measurements require a bright, spectrally smooth, and broad-band x-ray source. In a laser facility, such an x-ray source can be generated by a laser-driven capsule implosion. In order to optimize the x-ray emission, different capsule types and laser irradiations have been tested at the National Ignition Facility (NIF). A crystal spectrometer is used to disperse the x-rays and high efficiency image plate detectors are used to measure the absorption spectra in transmission geometry. EXAFS measurements at the K-edge of iron at ambient conditions have been obtained for the first time on the NIF laser, and the requirements for optimization have been established.

16.
Rev Sci Instrum ; 87(11): 11D612, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910647

RESUMO

We present a technique for determining the X-ray spectral quality from each region of an elliptically curved PET(002) crystal. The investigative technique utilizes the shape of the crystal rocking curve which changes significantly as the radius of curvature changes. This unique quality information enables the spectroscopist to verify where in the spectral range that the spectrometer performance is satisfactory and where there are regions that would show spectral distortion. A collection of rocking curve measurements for elliptically curved PET(002) has been built up in our X-ray laboratory. The multi-lamellar model from the XOP software has been used as a guide and corrections were applied to the model based upon measurements. But, the measurement of RI at small radius of curvature shows an anomalous behavior; the multi-lamellar model fails to show this behavior. The effect of this anomalous RI behavior on an X-ray spectrometer calibration is calculated. It is compared to the multi-lamellar model calculation which is completely inadequate for predicting RI for this range of curvature and spectral energies.

17.
Rev Sci Instrum ; 87(11): 11E330, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910695

RESUMO

The Dante is an 18 channel filtered diode array used at the National Ignition Facility (NIF) to measure the spectrally and temporally resolved radiation flux between 50 eV and 20 keV from various targets. The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and a reconstruction algorithm applied to the recorded voltages from each channel. The reconstructed spectra are very low resolution with features consistent with the instrument response and are not necessarily consistent with the spectral emission features from the plasma. Errors may exist between the reconstructed spectra and the actual emission features due to assumptions in the algorithm. Recently, a high resolution convex crystal spectrometer, VIRGIL, has been installed at NIF with the same line of sight as the Dante. Spectra from L-shell Ag and Xe have been recorded by both VIRGIL and Dante. Comparisons of these two spectroscopic measurements yield insights into the accuracy of the Dante reconstructions.

18.
Rev Sci Instrum ; 87(11): 11E344, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910374

RESUMO

A high resolution (E/ΔE = 1200-1800) Bragg crystal x-ray spectrometer is being developed to measure plasma parameters in National Ignition Facility experiments. The instrument will be a diagnostic instrument manipulator positioned cassette designed mainly to infer electron density in compressed capsules from Stark broadening of the helium-ß (1s2-1s3p) lines of krypton and electron temperature from the relative intensities of dielectronic satellites. Two conically shaped crystals will diffract and focus (1) the Kr Heß complex and (2) the Heα (1s2-1s2p) and Lyα (1s-2p) complexes onto a streak camera photocathode for time resolved measurement, and a third cylindrical or conical crystal will focus the full Heα to Heß spectral range onto an image plate to provide a time integrated calibration spectrum. Calculations of source x-ray intensity, spectrometer throughput, and spectral resolution are presented. Details of the conical-crystal focusing properties as well as the status of the instrumental design are also presented.

19.
Phys Rev Lett ; 112(23): 233003, 2014 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-24972204

RESUMO

High-resolution spectroscopy of the 2s(1/2)-2p(1/2) transition in the extreme ultraviolet region is shown to resolve the level splitting induced by the nuclear magnetic field of both the 2s(1/2) and the 2p(1/2) levels in lithiumlike (141)Pr(56+) and of the 2s(1/2)2p(1/2) (3)P(1) level in berylliumlike (141)Pr(55+). The (141)Pr ions are an ideal test of this measurement approach because their energy levels are known well from first principles and are unaffected by small energy contributions from QED and nuclear magnetization effects. The accuracy attained in the measured 196.5 ± 1.2 meV 2s(1/2) splitting is more than an order of magnitude better than that achieved before using crystal spectroscopy of the 2s(1/2)-2p(3/2) x-ray transition and at the level needed to implement a proposed scheme for disentangling the contributions from QED and nuclear magnetization effects in higher-Z ions, such as (209)Bi.

20.
Phys Rev Lett ; 111(11): 114803, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-24074095

RESUMO

Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA