Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cytometry B Clin Cytom ; 106(1): 25-34, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38217297

RESUMO

Since response to antigen-based immunotherapy relies upon the level of tumor antigen expression we developed an antigen quantification assay using ABC values. Antigen quantification as a clinical assay requires methods for quality control and for interlaboratory and inter-cytometer platform standardization. A single lot of Cytotrol™ Lyophilized Control Cells (Beckman Coulter) used for all studies. The variability in antigen quantification across 4 different instrument platforms in 2 separate laboratories was evaluated. The effect of the antibody clone utilized, importance of custom 1:1 molar ratio (fluorophore to protein, F/P) verses off-the-shelf antibodies, and QuantiBrite PE calibration verses linearity calibration combined with a single point scale transformation with CD4 as reference were determined. Use of single lot control cells allowed validation of reproducibility between flow cytometer platforms and laboratories and allowed assessment of different antibody lots, cocktail preparation, and different antibody clones. Off the shelf antibody preparations provide reproducible estimates of antigen density, however custom 1:1 unimolar antibody preparations should be utilized for definitive measurement of antigen expression.Geometric Mean fluorescent Intensity (GeoMFI) was not comparable across instruments and inter-laboratory. The use of CD4 as the reference marker can minimize variability in ABC values. Comparable antigen quantification is vital in managing patients receiving antigen-based immunotherapy. If this assay is to be utilized in a clinical setting, quality control methods have to be instituted to assure reproducibility and allow validation across laboratories. We have demonstrated that use of a lyophilized cell control is highly valuable in achieveing these goals.


Assuntos
Anticorpos , Antígenos , Humanos , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Padrões de Referência
2.
Int J Mol Sci ; 24(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958688

RESUMO

COVID-19 has highlighted challenges in the measurement quality and comparability of serological binding and neutralization assays. Due to many different assay formats and reagents, these measurements are known to be highly variable with large uncertainties. The development of the WHO international standard (WHO IS) and other pool standards have facilitated assay comparability through normalization to a common material but does not provide assay harmonization nor uncertainty quantification. In this paper, we present the results from an interlaboratory study that led to the development of (1) a novel hierarchy of data analyses based on the thermodynamics of antibody binding and (2) a modeling framework that quantifies the probability of neutralization potential for a given binding measurement. Importantly, we introduced a precise, mathematical definition of harmonization that separates the sources of quantitative uncertainties, some of which can be corrected to enable, for the first time, assay comparability. Both the theory and experimental data confirmed that mAbs and WHO IS performed identically as a primary standard for establishing traceability and bridging across different assay platforms. The metrological anchoring of complex serological binding and neuralization assays and fast turn-around production of an mAb reference control can enable the unprecedented comparability and traceability of serological binding assay results for new variants of SARS-CoV-2 and immune responses to other viruses.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Anticorpos Monoclonais , Bioensaio , Análise de Dados , Anticorpos Antivirais , Anticorpos Neutralizantes
3.
Int J Mol Sci ; 24(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37569707

RESUMO

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Citometria de Fluxo , Anticorpos Antivirais , Testes de Neutralização/métodos , Anticorpos Neutralizantes
4.
Nanomaterials (Basel) ; 12(18)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36144906

RESUMO

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.

5.
Biotechniques ; 72(6): 279-286, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35703314

RESUMO

Although several genome editing options are available, CRISPR/Cas9 is one of the most commonly used systems for protein and advanced therapies. There are some long-term data regarding genomic and phenotypic stability, however, information is sparse. Flow cytometry can offer a method to characterize these edited cells for longitudinal studies. The objective of this work is to describe a protocol for using flow cytometry to measure the edits from CRISPR/Cas9 on a well-characterized B-lymphoblast cell line, GM24385, with the goal of supporting safe and effective CRISPR/Cas9-engineered therapies.


Assuntos
Sistemas CRISPR-Cas , Edição de Genes , Sistemas CRISPR-Cas/genética , Linhagem Celular , Citometria de Fluxo , Edição de Genes/métodos
6.
J Ethnopharmacol ; 286: 114901, 2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-34890730

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Pheretima is a traditional Chinese medicine that could treat various lung diseases such as asthma, pneumonia, and lung cancer effectively; however, limited studies on the use of Pheretima protein in the treatment of lung diseases have been conducted to date. AIM OF THE STUDY: The aim of this study was to explain the antipulmonary fibrosis mechanism of the Pheretima protein and elucidate its possible cell signaling pathways. MATERIAL AND METHODS: Fresh pheretima was freeze-dried to obtain the Pheretima protein. Divide C57BL/6 mice into control and bleomycin (BLM)-induced models, pirfenidone, and Pheretima protein-treatment groups. Three weeks later, they were treated with H&E and Masson's trichrome staining to assess lung injury and fibrosis. Pulmonary fibrosis was assessed using immunohistochemistry (IHC), realtime-PCR (RT-PCR), and western blotting. Inflammation was assessed using the alveolar lavage fluid. RESULTS: Pheretima protein inhibited epithelial-mesenchymal transition (EMT) and extracellular matrix (ECM) deposition and reduced inflammation. It also reduced the levels of Smad2/3, pSmad2/3, and transforming growth factor-beta 1 (TGF-ß1). Thus, our results indicate that Pheretima protein can alleviate BLM-induced pulmonary fibrosis in a mouse model. CONCLUSION: Pheretima protein inhibits ECM, EMT, and antiinflammatory markers, which in turn ameliorates BLM-induced pulmonary fibrosis. Preliminary mechanistic studies indicated that Pheretima protein can exert its biological activity by downregulating the TGF-ß1/Smad2/3 pathway.


Assuntos
Fibrose Pulmonar Idiopática/tratamento farmacológico , Inflamação/tratamento farmacológico , Medicina Tradicional Chinesa/métodos , Proteínas/farmacologia , Animais , Anti-Inflamatórios/isolamento & purificação , Anti-Inflamatórios/farmacologia , Bleomicina , Modelos Animais de Doenças , Liofilização , Fibrose Pulmonar Idiopática/fisiopatologia , Inflamação/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Oligoquetos/química , Proteínas/isolamento & purificação , Piridonas/farmacologia , Proteína Smad2/metabolismo , Proteína Smad3/metabolismo , Fator de Crescimento Transformador beta1/metabolismo
7.
Int J Mol Sci ; 22(15)2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-34361020

RESUMO

A stochastic model of the flow cytometer measurement process was developed to assess the nature of the observed coefficient of variation (CV%) of the mean fluorescence intensity (MFI) from a population of labeled microspheres (beads). Several sources of variability were considered: the total number of labels on a bead, the path through the laser beam, the optical absorption cross-section, the quantum yield, the numerical aperture of the collection optics, and the photoelectron conversion efficiency of the photomultiplier (PMT) cathode. The variation in the number of labels on a bead had the largest effect on the CV% of the MFI of the bead population. The variation in the path of the bead through the laser beam was minimized using flat-top lasers. The variability in the average optical properties of the labels was of minor importance for beads with sufficiently large number of labels. The application of the bead results to the measured CV% of labeled B cells indicated that the measured CV% was a reliable measure of the variability of antibodies bound per cell. With some modifications, the model can be extended to multicolor flow cytometers and to the study of CV% from cells with low fluorescence signal.


Assuntos
Linfócitos B/citologia , Citometria de Fluxo/normas , Microesferas , Análise de Variância , Citometria de Fluxo/métodos , Humanos , Reprodutibilidade dos Testes , Processos Estocásticos
8.
Int J Mol Sci ; 22(5)2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33800363

RESUMO

Quantitative and robust serology assays are critical measurements underpinning global COVID-19 response to diagnostic, surveillance, and vaccine development. Here, we report a proof-of-concept approach for the development of quantitative, multiplexed flow cytometry-based serological and neutralization assays. The serology assays test the IgG and IgM against both the full-length spike antigens and the receptor binding domain (RBD) of the spike antigen. Benchmarking against an RBD-specific SARS-CoV IgG reference standard, the anti-SARS-CoV-2 RBD antibody titer was quantified in the range of 37.6 µg/mL to 31.0 ng/mL. The quantitative assays are highly specific with no correlative cross-reactivity with the spike proteins of MERS, SARS1, OC43 and HKU1 viruses. We further demonstrated good correlation between anti-RBD antibody titers and neutralizing antibody titers. The suite of serology and neutralization assays help to improve measurement confidence and are complementary and foundational for clinical and epidemiologic studies.


Assuntos
Teste Sorológico para COVID-19/métodos , Teste Sorológico para COVID-19/normas , COVID-19/sangue , COVID-19/imunologia , Testes de Neutralização/métodos , Testes de Neutralização/normas , SARS-CoV-2/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Reações Cruzadas , Citometria de Fluxo/métodos , Fluorescência , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Microesferas , Receptores Virais/química , Receptores Virais/imunologia , Glicoproteína da Espícula de Coronavírus/química , Glicoproteína da Espícula de Coronavírus/imunologia
9.
Materials (Basel) ; 13(18)2020 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-32947933

RESUMO

The National Institute of Standards and Technology (NIST), the National Institutes of Health (NIH) and other industry stakeholders have been working together to enable fluorescence intensities of flow cytometer calibration beads to be assigned quantitative equivalent reference fluorophore (ERF) values with high accuracy and precision. The ultimate goal of this effort is to accurately quantify the number of antibodies bound to individual living cells. The expansion of this effort to assign ERF values to more than 50 fluorescence channels and particles with diameters ranging from 10 µm down to 80 nm is reported here.

10.
Artigo em Inglês | MEDLINE | ID: mdl-34095644

RESUMO

Accurate determination of cellular subsets that secrete particular cytokine(s) is a significant parameter for functional characterization of an immunological response. The present study was conducted to develop a method for simultaneous measurement of intracellular cytokine positive CD4 and CD8 positive T lymphocytes in a single tube, with a no-wash protocol. We report here the development of a simplified, rapid procedure for precise enumeration of cytokine positive T lymphocytes using BD Trucount tubes. This single step protocol for accurate enumeration of cytokine positive T lymphocytes, will allow for better characterization of immune cell phenotype and function.

11.
J Exp Med ; 206(12): 2685-99, 2009 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-19917777

RESUMO

The transcription factor Ets1 contributes to the differentiation of CD8 lineage cells in the thymus, but how it does so is not understood. In this study, we demonstrate that Ets1 is required for the proper termination of CD4 expression during the differentiation of major histocompatability class 1 (MHC I)-restricted thymocytes, but not for other events associated with their positive selection, including the initiation of cytotoxic gene expression, corticomedullary migration, or thymus exit. We further show that Ets1 promotes expression of Runx3, a transcription factor important for CD8 T cell differentiation and the cessation of Cd4 gene expression. Enforced Runx3 expression in Ets1-deficient MHC I-restricted thymocytes largely rescued their impaired Cd4 silencing, indicating that Ets1 is not required for Runx3 function. Finally, we document that Ets1 binds at least two evolutionarily conserved regions within the Runx3 gene in vivo, supporting the possibility that Ets1 directly contributes to Runx3 transcription. These findings identify Ets1 as a key player during CD8 lineage differentiation and indicate that it acts, at least in part, by promoting Runx3 expression.


Assuntos
Antígenos CD4/imunologia , Linfócitos T CD8-Positivos/imunologia , Diferenciação Celular/imunologia , Subunidade alfa 3 de Fator de Ligação ao Core/imunologia , Proteína Proto-Oncogênica c-ets-1/imunologia , Timo/imunologia , Regulação para Cima/imunologia , Animais , Antígenos CD4/genética , Linfócitos T CD8-Positivos/citologia , Diferenciação Celular/genética , Subunidade alfa 3 de Fator de Ligação ao Core/genética , Antígenos de Histocompatibilidade Classe I/genética , Antígenos de Histocompatibilidade Classe I/imunologia , Camundongos , Camundongos Knockout , Proteína Proto-Oncogênica c-ets-1/genética , Elementos de Resposta/genética , Elementos de Resposta/imunologia , Timo/citologia , Transcrição Gênica/genética , Transcrição Gênica/imunologia , Regulação para Cima/genética
12.
Infect Immun ; 75(3): 1144-53, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17158902

RESUMO

CD97 is a member of the adhesion family of G protein-coupled receptors. Alternatively spliced forms of CD97 bind integrins alpha5beta1 and alphavbeta3, decay accelerating factor, or dermatan sulfate. CD97 is expressed on myeloid cells at high levels and a variety of other cell types at lower levels. Little is known about the physiological function of CD97. To begin dissecting the function of CD97, we evaluated the immune response of CD97 null mice to systemic infection by Listeria monocytogenes. CD97 null mice were significantly more resistant to listeriosis than matched wild-type mice. A major determinant of the difference in survival appeared to be the comparatively more robust accumulation of granulocytes in the blood and in infected livers of CD97 null mice within 18 h of inoculation, correlating with a decrease in the number of bacteria. CD97 null mice also displayed a mild granulocytosis in the nonchallenged state. Because there is a strong suggestion that CD97 functions in an adhesive capacity, we examined the migratory properties of granulocytes in CD97 null mice. In chimeric animals, CD97 null and wild-type granulocytes migrated similarly, as determined by inflammation-induced emigration from the bone marrow and accumulation in the peritoneum. Granulocyte development in the bone marrow of CD97 null mice was comparable to that of wild-type mice, and CD97 deficiency did not appear to stimulate granulocytosis secondary to peripheral inflammation and resultant granulocyte colony-stimulating factor induction, unlike various other models of adhesion deficiencies. Our results suggest that CD97 plays a role in peripheral granulocyte homeostasis.


Assuntos
Antígenos CD/genética , Moléculas de Adesão Celular/deficiência , Moléculas de Adesão Celular/genética , Granulócitos/metabolismo , Homeostase/genética , Listeriose/genética , Listeriose/imunologia , Glicoproteínas de Membrana/genética , Animais , Adesão Celular/imunologia , Movimento Celular/imunologia , Granulócitos/imunologia , Granulócitos/patologia , Homeostase/imunologia , Listeriose/metabolismo , Listeriose/patologia , Glicoproteínas de Membrana/deficiência , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Receptores Acoplados a Proteínas G
13.
Blood ; 105(7): 2836-44, 2005 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15576472

RESUMO

CD97, a membrane protein expressed at high levels on inflammatory cells and some carcinomas, is a member of the adhesion G protein-coupled receptor family, whose members have bipartite structures consisting of an extracellular peptide containing adhesion motifs noncovalently coupled to a class B 7-transmembrane domain. CD97alpha, the extracellular domain of CD97, contains 3 to 5 fibrillin class 1 epidermal growth factor (EGF)-like repeats, an Arg-Gly-Asp (RGD) tripeptide, and a mucin stalk. We show here that CD97alpha promotes angiogenesis in vivo as demonstrated with purified protein in a directed in vivo angiogenesis assay (DIVAA) and by enhanced vascularization of developing tumors expressing CD97. These data suggest that CD97 can contribute to angiogenesis associated with inflammation and tumor progression. Strong integrin alpha5beta1 interactions with CD97 have been identified, but alpha v beta3 also contributes to cell attachment. Furthermore, soluble CD97 acts as a potent chemoattractant for migration and invasion of human umbilical vein endothelial cells (HUVECs), and this function is integrin dependent. CD97 EGF-like repeat 4 is known to bind chondroitin sulfate. It was found that coengagement of alpha5beta1 and chondroitotin sulfate proteoglycan by CD97 synergistically initiates endothelial cell invasion. Integrin alpha5beta1 is the first high-affinity cellular counterreceptor that has been identified for a member within this family of adhesion receptors.


Assuntos
Endotélio Vascular/metabolismo , Integrina alfa5beta1/metabolismo , Glicoproteínas de Membrana/metabolismo , Neoplasias/metabolismo , Neovascularização Fisiológica/fisiologia , Animais , Antígenos CD , Adesão Celular/fisiologia , Sulfatos de Condroitina/metabolismo , Endotélio Vascular/citologia , Fator de Crescimento Epidérmico/genética , Células HT29 , Humanos , Integrina alfaVbeta3/metabolismo , Glicoproteínas de Membrana/química , Glicoproteínas de Membrana/genética , Camundongos , Células NIH 3T3 , Neoplasias/irrigação sanguínea , Neoplasias/fisiopatologia , Oligopeptídeos/genética , Fenótipo , Estrutura Terciária de Proteína , Ratos , Receptores Acoplados a Proteínas G , Veias Umbilicais/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA