Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Front Neurol ; 14: 1256984, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020587

RESUMO

Background: Sudomotor dysfunction is one of the earliest manifestations of small fiber neuropathy (SFN), reflecting the alteration of sympathetic C fiber innervation of the sweat glands. Among other techniques, such innervation can be assessed by measuring electrochemical skin conductance (ESC) in microsiemens (µS). In this study, ESC was measured at the feet to detect distal SFN. For this objective, the performance of a new device, the Body Scan® (Withings, France), intended for home use, was compared with that of a reference device, the Sudoscan® (Impeto Medical, France), which requires a hospital setting. Methods: In patients with diabetes with or without neuropathy or non-diabetic patients with lower-limb neuropathy, the diagnostic performance of the Body Scan® measurement was assessed by calculating its sensitivity (Se) and specificity (Sp) to detect at least moderate SFN (Se70 and Sp70), defined by a value of feet ESC ≤ 70 µS and > 50 µS on the Sudoscan® measure, or severe SFN (Se50 and Sp50), defined by a value of feet ESC ≤ 50 µS on the Sudoscan® measure. The agreement between the two devices was assessed with the analysis of Bland-Altman plots, mean absolute error (MAE), and root mean squared error (RMSE) calculations. The repeatability of the measurements was also compared between the two devices. Results: A total of 147 patients (52% men, mean age 59 years old, 76% diabetic) were included in the analysis. The sensitivity and specificity to detect at least moderate or severe SFN were: Se70 = 0.91 ([0.83, 0.96]), Sp70 = 0.97 ([0.88, 0.99]), Se50 = 0.91 ([0.80, 0.98]), and Sp50 = 0.99 ([0.94, 1]), respectively. The bias and 95% limits of agreement were 1.5 [-5.4, 8.4]. The MAE was 2.9 and the RMSE 3.8. The intra-sample variability was 2.0 for the Body Scan® and 2.3 for the Sudoscan®. Conclusion: The ESC measurements provided by the Body Scan® were in almost perfect agreement with those provided by the reference device, the Sudoscan®, which validates the accuracy of the Body Scan® for the detection of SFN. By enabling simple, rapid, and autonomous use by the patient at home, this new technique will facilitate screening and monitoring of SFN in daily practice. Clinical trial registration: ClinicalTrials.gov, identifier NCT05178459.

2.
J Endocr Soc ; 6(8): bvac087, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35733830

RESUMO

Hepatocyte nuclear factor-1B (HNF1B) maturity-onset diabetes of the young (MODY), also referred to as "renal cysts and diabetes syndrome" or MODY-5, is a rare form of monogenic diabetes that is caused by a deletion or a point mutation in the HNF1B gene, a developmental gene that plays a key role in regulating urogenital and pancreatic development. HNF1B-MODY has been characterized by its association with renal, hepatic and other extrapancreatic features. We present the case of a 39-year-old female patient who was first diagnosed with type 1 diabetes, but then, owing to the absence of anti-islet autoantibodies and to the disease's progression, was labeled later on as having atypical type 2 diabetes. She was finally recognized as having HNF1B-MODY, a diagnosis that had been suggested by the lack of metabolic syndrome and by the presence of unexplained chronically disturbed liver function tests and hypomagnesemia. There was a 10-year delay between the onset of diabetes and the molecular diagnosis. An atypical form of diabetes, especially in patients with multisystem involvement, should raise suspicion for an alternative etiology. A timely diagnosis of HNF1B-MODY is of utmost importance since it can greatly impact diabetes management and disease progression as well as family history.

3.
Cardiovasc Intervent Radiol ; 44(7): 1017-1027, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33948700

RESUMO

PURPOSE: Restenosis remains a limitation of endovascular angioplasty with a patency of 30% in BTK at 12 months. Several studies on drug-coated balloons have not demonstrated any improvements in terms of patency and target lesions revascularization in BTK lesions. This prospective single-centre cohort study evaluates the safety and efficacy of a new generation low-dose drug-coated balloon (DCB) with a reduced crystalline structure to treat below the knee (BTK) lesions in patients with critical limb ischemia (CLI). MATERIALS AND METHODS: Between November 2016 and November 2017, 30 consecutive patients (mean 68.8 ± 12.7 years, 6 female) with BTK lesions and CLI were included in this single-centre, prospective non-randomized cohort study. All patients with rest pain and/or ischemic wound associated with BTK lesions were included in the study. Mean lesion length was 133.6 ± 94.5 mm and 18(60%) were chronic total occlusions. The primary safety outcome parameter was a composite of all-cause mortality and major amputation at 6 months. The primary efficacy outcome parameter was the primary angiographic patency at 6 months (defined as freedom from clinically driven target lesion revascularization and the absence of significant restenosis (> 50%) as determined by core laboratory angiography assessment. Immediate technical success, late lumen loss (LLL), clinical target lesion revascularization (TLR) and ulcer healing rates at 12 months were also evaluated. RESULTS: Immediate technical success was 97%(29/30): one patient had an acute thrombosis at the completion of index procedure. Primary safety outcome parameter was 94%(28/30): one patient underwent major amputation and one patient died of other comorbidities at 2 months. Another patient had a major amputation at 7.5 months. Angiographic follow-up was available in 20 patients. Primary angiographic patency was 57%(12/21 lesions), and LLL was 0.99 ± 0.68 mm at 6 months. Freedom from TLR was 89% at 12 months. The rate of ulcer healing was 76% at 12 months. CONCLUSION: Ranger DCB balloons to treat CLI patients demonstrated a positive trend with good safety outcomes parameters. Further randomized studies are needed to understand the usefulness compared to POBA.


Assuntos
Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis , Isquemia/cirurgia , Salvamento de Membro/métodos , Paclitaxel/farmacologia , Artéria Poplítea/transplante , Procedimentos Cirúrgicos Vasculares/métodos , Idoso , Antineoplásicos Fitogênicos/farmacologia , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA