Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Pharmaceutics ; 16(4)2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38675195

RESUMO

This work investigates the proposed enhanced efficacy of photodynamic therapy (PDT) by activating photosensitizers (PSs) with Cherenkov light (CL). The approaches of Yoon et al. to test the effect of CL with external radiation were taken up and refined. The results were used to transfer the applied scheme from external radiation therapy to radionuclide therapy in nuclear medicine. Here, the CL for the activation of the PSs (psoralen and trioxsalen) is generated by the ionizing radiation from rhenium-188 (a high-energy beta-emitter, Re-188). In vitro cell survival studies were performed on FaDu, B16 and 4T1 cells. A characterization of the PSs (absorbance measurement and gel electrophoresis) and the CL produced by Re-188 (luminescence measurement) was performed as well as a comparison of clonogenic assays with and without PSs. The methods of Yoon et al. were reproduced with a beam line at our facility to validate their results. In our studies with different concentrations of PS and considering the negative controls without PS, the statements of Yoon et al. regarding the positive effect of CL could not be confirmed. There are slight differences in survival fractions, but they are not significant when considering the differences in the controls. Gel electrophoresis showed a dominance of trioxsalen over psoralen in conclusion of single and double strand breaks in plasmid DNA, suggesting a superiority of trioxsalen as a PS (when irradiated with UVA). In addition, absorption measurements showed that these PSs do not need to be shielded from ambient light during the experiment. An observational test setup for a PDT nuclear medicine approach was found. The CL spectrum of Re-188 was measured. Fluctuating inconclusive results from clonogenic assays were found.

2.
Phys Med Biol ; 69(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38537301

RESUMO

Thein vivoevolution of radiotherapy necessitates innovative platforms for preclinical investigation, bridging the gap between bench research and clinical applications. Understanding the nuances of radiation response, specifically tailored to proton and photon therapies, is critical for optimizing treatment outcomes. Within this context, preclinicalin vivoexperimental setups incorporating image guidance for both photon and proton therapies are pivotal, enabling the translation of findings from small animal models to clinical settings. TheSAPPHIREproject represents a milestone in this pursuit, presenting the installation of the small animal radiation therapy integrated beamline (SmART+ IB, Precision X-Ray Inc., Madison, Connecticut, USA) designed for preclinical image-guided proton and photon therapy experiments at University Proton Therapy Dresden. Through Monte Carlo simulations, low-dose on-site cone beam computed tomography imaging and quality assurance alignment protocols, the project ensures the safe and precise application of radiation, crucial for replicating clinical scenarios in small animal models. The creation of Hounsfield lookup tables and comprehensive proton and photon beam characterizations within this system enable accurate dose calculations, allowing for targeted and controlled comparison experiments. By integrating these capabilities,SAPPHIREbridges preclinical investigations and potential clinical applications, offering a platform for translational radiobiology research and cancer therapy advancements.


Assuntos
Fótons , Terapia com Prótons , Radioterapia Guiada por Imagem , Fótons/uso terapêutico , Animais , Radioterapia Guiada por Imagem/métodos , Terapia com Prótons/métodos , Método de Monte Carlo , Prótons , Camundongos
3.
Front Oncol ; 12: 982417, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36419890

RESUMO

Background and purpose: Proton therapy has become a popular treatment modality in the field of radiooncology due to higher spatial dose conformity compared to conventional radiotherapy, which holds the potential to spare normal tissue. Nevertheless, unresolved research questions, such as the much debated relative biological effectiveness (RBE) of protons, call for preclinical research, especially regarding in vivo studies. To mimic clinical workflows, high-precision small animal irradiation setups with image-guidance are needed. Material and methods: A preclinical experimental setup for small animal brain irradiation using proton radiographies was established to perform planning, repositioning, and irradiation of mice. The image quality of proton radiographies was optimized regarding the resolution, contrast-to-noise ratio (CNR), and minimal dose deposition in the animal. Subsequently, proof-of-concept histological analysis was conducted by staining for DNA double-strand breaks that were then correlated to the delivered dose. Results: The developed setup and workflow allow precise brain irradiation with a lateral target positioning accuracy of<0.26mm for in vivo experiments at minimal imaging dose of<23mGy per mouse. The custom-made software for image registration enables the fast and precise animal positioning at the beam with low observer-variability. DNA damage staining validated the successful positioning and irradiation of the mouse hippocampus. Conclusion: Proton radiography enables fast and effective high-precision lateral alignment of proton beam and target volume in mouse irradiation experiments with limited dose exposure. In the future, this will enable irradiation of larger animal cohorts as well as fractionated proton irradiation.

4.
Cancers (Basel) ; 14(19)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36230481

RESUMO

In times of high-precision radiotherapy, the accurate and precise definition of the primary tumor localization and its microscopic spread is of enormous importance. In glioblastoma, the microscopic tumor extension is uncertain and, therefore, population-based margins for Clinical Target Volume (CTV) definition are clinically used, which could either be too small-leading to increased risk of loco-regional recurrences-or too large, thus, enhancing the probability of normal tissue toxicity. Therefore, the aim of this project is to investigate an individualized definition of the CTV in preclinical glioblastoma models based on specific biological tumor characteristics. The microscopic tumor extensions of two different orthotopic brain tumor models (U87MG_mCherry; G7_mCherry) were evaluated before and during fractionated radiotherapy and correlated with corresponding histological data. Representative tumor slices were analyzed using Matrix-Assisted Laser Desorption/Ionization (MALDI) and stained for putative stem-like cell markers as well as invasion markers. The edges of the tumor are clearly shown by the MALDI segmentation via unsupervised clustering of mass spectra and are consistent with the histologically defined border in H&E staining in both models. MALDI component analysis identified specific peaks as potential markers for normal brain tissue (e.g., 1339 m/z), whereas other peaks demarcated the tumors very well (e.g., 1562 m/z for U87MG_mCherry) irrespective of treatment. MMP14 staining revealed only a few positive cells, mainly in the tumor border, which could reflect the invasive front in both models. The results of this study indicate that MALDI information correlates with microscopic tumor spread in glioblastoma models. Therefore, an individualized CTV definition based on biological tumor characteristics seems possible, whereby the visualization of tumor volume and protein heterogeneity can be potentially used to define radiotherapy-sensitive and resistant areas.

5.
Radiother Oncol ; 146: 205-212, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32222488

RESUMO

BACKGROUND AND PURPOSE: Proton radiotherapy offers the potential to reduce normal tissue toxicity. However, clinical safety margins, range uncertainties, and varying relative biological effectiveness (RBE) may result in a critical dose in tumor-surrounding normal tissue. To assess potential adverse effects in preclinical studies, image-guided proton mouse brain irradiation and analysis of DNA damage repair was established. MATERIAL AND METHODS: We designed and characterized a setup to shape proton beams with 7 mm range in water and 3 mm in diameter and commissioned a Monte Carlo model for in vivo dose simulation. Cone-beam computed tomography and orthogonal X-ray imaging were used to delineate the right hippocampus and position the mice. The brains of three C3H/HeNRj mice were irradiated with 8 Gy and excised 30 min later. Initial DNA double-strand breaks were visualized by staining brain sections for cell nuclei and γH2AX. Imaged sections were analyzed with an automated and validated processing pipeline to provide a quantitative, spatially resolved radiation damage indicator. RESULTS: The analyzed DNA damage pattern clearly visualized the radiation effect in the mouse brains and could be mapped to the simulated dose distribution. The proton beam passed the right hippocampus and stopped in the central brain region for all evaluated mice. CONCLUSION: We established image-guided proton irradiation of mouse brains. The clinically oriented workflow facilitates (back-) translational studies. Geometric accuracy, detailed Monte Carlo dose simulations, and cell-based assessment enable a biologically and spatially resolved analysis of radiation response and RBE.


Assuntos
Terapia com Prótons , Animais , Encéfalo , Camundongos , Camundongos Endogâmicos C3H , Método de Monte Carlo , Prótons , Eficiência Biológica Relativa
6.
Biomed Phys Eng Express ; 6(3): 037003, 2020 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-33438682

RESUMO

Preclinical imaging and irradiation yields valuable insights into clinically relevant research topics. While complementary imaging methods such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET) can be combined within single devices, this is technically demanding and cost-intensive. Similarly, bedding and setup solutions are often specific to certain devices and research questions. We present a bedding platform for mice that is compatible with various preclinical imaging modalities (combined PET/MRI, cone beam CT) and irradiation with photons and protons. It consists of a 3D-printed bedding unit (acrylonitrile butadiene styrene, ABS) holding the animal and features an inhalation anesthesia mask, jaw fixation, ear pins, and immobilization for the hind leg. It can be embedded on mounting adaptors for multi-modal imaging and into a transport box (polymethyl methacrylate, PMMA) for experiments outside dedicated animal facilities while maintaining the animal's hygiene status. A vital support unit provides heating, inhalation anesthesia, and a respiration monitor. We dosimetrically evaluated used materials in order to assess their interaction with incident irradiation. Proof-of-concept multi-modal imaging protocols were used on phantoms and mice. The measured attenuation of the bedding unit for 40/60/80/200 kV X-rays was less than 3%. The measured stopping-power-ratio of ABS was 0.951, the combined water-equivalent thickness of bedding unit and transport box was 4.2 mm for proton energies of 150 MeV and 200 MeV. Proof-of-concept imaging showed no loss of image quality. Imaging data of individual mice from different imaging modalities could be aligned rigidly. The presented bed aims to provide a platform for experiments related to both multi-modal imaging and irradiation, thus offering the possibility for image-guided irradiation which relies on precise imaging and positioning. The usage as a self-contained, stand-alone unit outside dedicated animal facilities represents an advantage over setups designed for specific devices.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Radiometria , Radioterapia/métodos , Animais , Roupas de Cama, Mesa e Banho , Condutividade Elétrica , Desenho de Equipamento , Camundongos , Imagens de Fantasmas , Fótons , Terapia com Prótons/instrumentação , Radiografia , Radioterapia Guiada por Imagem/instrumentação , Raios X
7.
Br J Radiol ; 92(1095): 20180539, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30215546

RESUMO

OBJECTIVE:: Clinically relevant animal models of non-small cell lung carcinoma (NSCLC) are required for the validation of novel treatments. We compared two different orthotopic transplantation techniques as well as imaging modalities to identify suitable mouse models mimicking clinical scenarios. METHODS:: We used three genomically diverse NSCLC cell lines [National Cancer Institute (NCI)-H1703 adenosquamous cell carcinoma, NCI-H23 adenocarcinoma and A549 adenocarcinoma) for implanting tumour cells either as spheroids or cell suspension into lung parenchyma. Bioluminescence imaging (BLI) and contrast-enhanced cone beam CT (CBCT) were performed twice weekly to monitor tumour growth. Tumour histological data and microenvironmental parameters were determined. RESULTS:: Tumour development after spheroid-based transplantation differs probably due to the integrity of spheroids, as H1703 developed single localised nodules, whereas H23 showed diffuse metastatic spread starting early after transplantation. A549 transplantation as cell suspension with the help of a stereotactic system was associated with initial single localised tumour growth and eventual metastatic spread. Imaging techniques were successfully applied to monitor longitudinal tumour growth: BLI revealed highly sensitive qualitative data, whereas CBCT was associated with less sensitive quantitative data. Histology revealed significant model-dependent heterogeneity in proliferation, hypoxia, perfusion and necrosis. CONCLUSION:: Our developed orthotopic NSCLC tumours have similarity with biological growth behaviour comparable to that seen in the clinic and could therefore be used as attractive models to study tumour biology and evaluate new therapeutic strategies. The use of human cancer cell lines facilitates testing of different genomic tumour profiles that may affect treatment outcomes. ADVANCES IN KNOWLEDGE:: The combination of different imaging modalities to identify tumour growth with subsequent use in treatment planning and orthotopic transplantation techniques to develop initially single lesions to ultimate metastases pave the way towards representative pre-clinical NSCLC models for experimental testing of novel therapeutic options in future studies.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/veterinária , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/veterinária , Transplante Heterólogo/métodos , Animais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Linhagem Celular Tumoral , Tomografia Computadorizada de Feixe Cônico/veterinária , Modelos Animais de Doenças , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Camundongos , Transplante Heterólogo/veterinária , Microambiente Tumoral
8.
Phys Med Biol ; 61(8): 3084-108, 2016 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-27008208

RESUMO

Preclinical in vivo studies using small animals are essential to develop new therapeutic options in radiation oncology. Of particular interest are orthotopic tumour models, which better reflect the clinical situation in terms of growth patterns and microenvironmental parameters of the tumour as well as the interplay of tumours with the surrounding normal tissues. Such orthotopic models increase the technical demands and the complexity of preclinical studies as local irradiation with therapeutically relevant doses requires image-guided target localisation and accurate beam application. Moreover, advanced imaging techniques are needed for monitoring treatment outcome. We present a novel small animal image-guided radiation therapy (SAIGRT) system, which allows for precise and accurate, conformal irradiation and x-ray imaging of small animals. High accuracy is achieved by its robust construction, the precise movement of its components and a fast high-resolution flat-panel detector. Field forming and x-ray imaging is accomplished close to the animal resulting in a small penumbra and a high image quality. Feasibility for irradiating orthotopic models has been proven using lung tumour and glioblastoma models in mice. The SAIGRT system provides a flexible, non-profit academic research platform which can be adapted to specific experimental needs and therefore enables systematic preclinical trials in multicentre research networks.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Glioblastoma/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia Guiada por Imagem/métodos , Animais , Camundongos , Movimento , Imagens de Fantasmas , Ratos , Raios X
9.
Z Med Phys ; 24(4): 335-51, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25125191

RESUMO

For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained.


Assuntos
Radioterapia/instrumentação , Radioterapia/métodos , Pesquisa Translacional Biomédica/instrumentação , Pesquisa Translacional Biomédica/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Ratos , Tecnologia Radiológica/instrumentação , Tecnologia Radiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA