Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 25(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38791388

RESUMO

The use of targeted drug delivery systems, including those based on selective absorption by certain receptors on the surface of the target cell, can lead to a decrease in the minimum effective dose and the accompanying toxicity of the drug, as well as an increase in therapeutic efficacy. A fullerene C60 conjugate (FA-PVP-C60) with polyvinylpyrrolidone (PVP) as a biocompatible spacer and folic acid (FA) as a targeting ligand for tumor cells with increased expression of folate receptors (FR) was obtained. Using 13C NMR spectroscopy, FT-IR, UV-Vis spectrometry, fluorometry and thermal analysis, the formation of the conjugate was confirmed and the nature of the binding of its components was established. The average particle sizes of the conjugate in aqueous solutions and cell culture medium were determined using dynamic light scattering (DLS) and nanoparticle tracking analysis (NTA). The FA-PVP-C60 showed antiradical activity against •DPPH, •OH and O2•-, but at the same time, it was shown to generate 1O2. It was found that the conjugate in the studied concentration range (up to 200 µg/mL) is non-toxic in vitro and does not affect the cell cycle. To confirm the ability of the conjugate to selectively accumulate through folate-mediated endocytosis, its uptake into cells was analyzed by flow cytometry and confocal microscopy. It was shown that the conjugate is less absorbed by A549 cells with low FR expression than by HeLa, which has a high level of expression of this receptor.


Assuntos
Sistemas de Liberação de Medicamentos , Ácido Fólico , Fulerenos , Povidona , Ácido Fólico/química , Ácido Fólico/farmacologia , Humanos , Povidona/química , Fulerenos/química , Fulerenos/farmacologia , Sistemas de Liberação de Medicamentos/métodos , Linhagem Celular Tumoral , Células A549 , Células HeLa , Tamanho da Partícula
2.
J Exp Biol ; 226(12)2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37226998

RESUMO

Like many other animals, insects are capable of returning to previously visited locations using path integration, which is a memory of travelled direction and distance. Recent studies suggest that Drosophila can also use path integration to return to a food reward. However, the existing experimental evidence for path integration in Drosophila has a potential confound: pheromones deposited at the site of reward might enable flies to find previously rewarding locations even without memory. Here, we show that pheromones can indeed cause naïve flies to accumulate where previous flies had been rewarded in a navigation task. Therefore, we designed an experiment to determine if flies can use path integration memory despite potential pheromonal cues by displacing the flies shortly after an optogenetic reward. We found that rewarded flies returned to the location predicted by a memory-based model. Several analyses are consistent with path integration as the mechanism by which flies returned to the reward. We conclude that although pheromones are often important in fly navigation and must be carefully controlled for in future experiments, Drosophila may indeed be capable of performing path integration.


Assuntos
Sinais (Psicologia) , Drosophila , Animais , Recompensa , Insetos , Feromônios , Drosophila melanogaster
3.
Appl Spectrosc ; 67(12): 1401-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24359654

RESUMO

When several near-infrared instruments are used in a network and a common chemometric model is applied to spectral processing, comparison of the instruments is indispensable. Direct transferability often claimed by the producers should be treated with caution. It has been found experimentally that when measurements are performed with the help of a fiber optic probe, the main source of spectral discrepancy is related to probe sensitivity in contactless measurements. Here the influence of the probe-to-object distance on the acquired spectra is analyzed in detail. Special experimental setups are proposed to isolate various strongly influencing factors and to maintain stable measurement conditions. The application of an artificial standard instead of real-world objects helps to focus on the instrument/accessory characteristics.


Assuntos
Tecnologia de Fibra Óptica , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA