Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Prostate ; 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39327946

RESUMO

BACKGROUND: The medication used to treat benign prostate hyperplasia (BPH), a common condition in men over 50 years of age, can alter the levels of biomarkers used in prostate cancer detection. Commonly used medications for BPH include alpha-blockers, 5-alpha reductase inhibitors (5-ARIs), and muscarinic antagonists. We studied the impact of these drugs on total prostate-specific antigen (tPSA), free PSA (fPSA), [-2]proPSA, fPSA/tPSA ratio, and the Prostate Health Index (PHI), as well as novel potential biomarkers in the form of glycan composition of fPSA. PATIENTS AND METHODS: Serum samples were collected from 564 males with BPH, with a mean age of 68.5 years. The samples were used to measure levels of tPSA, fPSA, and [-2]proPSA. The fPSA/tPSA and PHI were then calculated. The glycan composition of fPSA was analyzed using lectin-based glycoprofiling. Pharmacotherapy data was collected from the patients' medical records. RESULTS: Alpha-blocker monotherapy was associated with higher fPSA and fPSA/tPSA ratio, and decreased PHI. Levels of tPSA were not impacted. Alpha-blocker and 5-ARI dual therapy was associated with reduced levels of fPSA, [-2]proPSA, and PHI. Therapy combining alpha-blockers and antimuscarinic agents did not significantly influence biomarker levels apart from an increase in a Maackia amurensis lectin-recognized glycan originating in fPSA. CONCLUSION: BPH pharmacotherapy notably affects prostate cancer biomarkers. Recognizing the impact of pharmacotherapy is crucial for achieving an accurate diagnosis of prostate cancer and for planning treatment.

2.
Nanomaterials (Basel) ; 14(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39120346

RESUMO

We investigated the use of boron-doped diamond (BDD) with different surface morphologies for the enhanced detection of nine different peptides by matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS). For the first time, we compared three different nanostructured BDD film morphologies (Continuous, Nanograss, and Nanotips) with differently terminated surfaces (-H, -O, and -F) to commercially available Ground Steel plates. All these surfaces were evaluated for their effectiveness in detecting the nine different peptides by MALDI-MS. Our results demonstrated that certain nanostructured BDD surfaces exhibited superior performance for the detection of especially hydrophobic peptides (e.g., bradykinin 1-7, substance P, and the renin substrate), with a limit of detection of down to 2.3 pM. Further investigation showed that hydrophobic peptides (e.g., bradykinin 1-7, substance P, and the renin substrate) were effectively detected on hydrogen-terminated BDD surfaces. On the other hand, the highly acidic negatively charged peptide adrenocorticotropic hormone fragment 18-39 was effectively identified on oxygen-/fluorine-terminated BDD surfaces. Furthermore, BDD surfaces reduced sodium adduct contamination significantly.

3.
Diagnostics (Basel) ; 14(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38611626

RESUMO

This review briefly introduces readers to an area where glycomics meets modern oncodiagnostics with a focus on the analysis of sialic acid (Neu5Ac)-terminated structures. We present the biochemical perspective of aberrant sialylation during tumourigenesis and its significance, as well as an analytical perspective on the detection of these structures using different approaches for diagnostic and therapeutic purposes. We also provide a comparison to other established liquid biopsy approaches, and we mathematically define an early-stage cancer based on the overall prognosis and effect of these approaches on the patient's quality of life. Finally, some barriers including regulations and quality of clinical validations data are discussed, and a perspective and major challenges in this area are summarised.

4.
PLoS One ; 19(3): e0300430, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38498504

RESUMO

The glycoprofiling of two proteins, the free form of the prostate-specific antigen (fPSA) and zinc-α-2-glycoprotein (ZA2G), was assessed to determine their suitability as prostate cancer (PCa) biomarkers. The glycoprofiling of proteins was performed by analysing changes in the glycan composition on fPSA and ZA2G using lectins (proteins that recognise glycans, i.e. complex carbohydrates). The specific glycoprofiling of the proteins was performed using magnetic beads (MBs) modified with horseradish peroxidase (HRP) and antibodies that selectively enriched fPSA or ZA2G from human serum samples. Subsequently, the antibody-captured glycoproteins were incubated on lectin-coated ELISA plates. In addition, a novel glycoprotein standard (GPS) was used to normalise the assay. The glycoprofiling of fPSA and ZA2G was performed in human serum samples obtained from men undergoing a prostate biopsy after an elevated serum PSA, and prostate cancer patients with or without prior therapy. The results are presented in the form of an ROC (Receiver Operating Curve). A DCA (Decision Curve Analysis) to evaluate the clinical performance and net benefit of fPSA glycan-based biomarkers was also performed. While the glycoprofiling of ZA2G showed little promise as a potential PCa biomarker, the glycoprofiling of fPSA would appear to have significant clinical potential. Hence, the GIA (Glycobiopsy ImmunoAssay) test integrates the glycoprofiling of fPSA (i.e. two glycan forms of fPSA). The GIA test could be used for early diagnoses of PCa (AUC = 0.83; n = 559 samples) with a potential for use in therapy-monitoring (AUC = 0.90; n = 176 samples). Moreover, the analysis of a subset of serum samples (n = 215) revealed that the GIA test (AUC = 0.81) outperformed the PHI (Prostate Health Index) test (AUC = 0.69) in discriminating between men with prostate cancer and those with benign serum PSA elevation.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Biomarcadores Tumorais , Próstata/patologia , Curva ROC , Detecção Precoce de Câncer , Neoplasias da Próstata/patologia , Glicoproteínas , Polissacarídeos
5.
Sensors (Basel) ; 24(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38400284

RESUMO

Prostate cancer (PCa) is the second most common cancer. In this paper, the isolation and properties of exosomes as potential novel liquid biopsy markers for early PCa liquid biopsy diagnosis are investigated using two prostate human cell lines, i.e., benign (control) cell line RWPE1 and carcinoma cell line 22Rv1. Exosomes produced by both cell lines are characterised by various methods including nanoparticle-tracking analysis, dynamic light scattering, scanning electron microscopy and atomic force microscopy. In addition, surface plasmon resonance (SPR) is used to study three different receptors on the exosomal surface (CD63, CD81 and prostate-specific membrane antigen-PMSA), implementing monoclonal antibodies and identifying the type of glycans present on the surface of exosomes using lectins (glycan-recognising proteins). Electrochemical analysis is used to understand the interfacial properties of exosomes. The results indicate that cancerous exosomes are smaller, are produced at higher concentrations, and exhibit more nega tive zeta potential than the control exosomes. The SPR experiments confirm that negatively charged α-2,3- and α-2,6-sialic acid-containing glycans are found in greater abundance on carcinoma exosomes, whereas bisecting and branched glycans are more abundant in the control exosomes. The SPR results also show that a sandwich antibody/exosomes/lectins configuration could be constructed for effective glycoprofiling of exosomes as a novel liquid biopsy marker.


Assuntos
Carcinoma , Exossomos , Masculino , Humanos , Exossomos/química , Biópsia Líquida , Carcinoma/metabolismo , Carcinoma/patologia , Lectinas/análise , Lectinas/metabolismo , Polissacarídeos/análise , Polissacarídeos/metabolismo
6.
Mikrochim Acta ; 191(2): 88, 2024 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-38206460

RESUMO

The initial part of the review provides an extensive overview about MXenes as novel and exciting 2D nanomaterials describing their basic physico-chemical features, methods of their synthesis, and possible interfacial modifications and techniques, which could be applied to the characterization of MXenes. Unique physico-chemical parameters of MXenes make them attractive for many practical applications, which are shortly discussed. Use of MXenes for healthcare applications is a hot scientific discipline which is discussed in detail. The article focuses on determination of low molecular weight analytes (metabolites), high molecular weight analytes (DNA/RNA and proteins), or even cells, exosomes, and viruses detected using electrochemical sensors and biosensors. Separate chapters are provided to show the potential of MXene-based devices for determination of cancer biomarkers and as wearable sensors and biosensors for monitoring of a wide range of human activities.


Assuntos
Exossomos , Nanoestruturas , Nitritos , Elementos de Transição , Humanos , Biomarcadores Tumorais , Peso Molecular
8.
Biotechnol Adv ; 67: 108196, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37307942

RESUMO

This review provides a comprehensive overview of our understanding of the role that glycans play in the formation, loading and release of extracellular vesicles (EVs). The capture of EVs (typically with a size of 100-200 nm) is described, including approaches based on glycan recognition with glycan-based analysis offering highly sensitive detection of EVs. Furthermore, detailed information is provided about the use of EV glycans and glycan processing enzymes as potential biomarkers, therapeutic targets or tools applied for regenerative medicine. The review also provides a short introduction into advanced methods for the characterization of EVs, new insights into the biomolecular corona covering EVs and bioanalytical tools available for glycan analysis.


Assuntos
Vesículas Extracelulares , Glicosilação , Vesículas Extracelulares/metabolismo , Biomarcadores , Polissacarídeos/metabolismo
9.
J Funct Biomater ; 14(3)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36976085

RESUMO

Screen-printing technology is a game changer in many fields including electrochemical biosensing. Two-dimensional nanomaterial MXene Ti3C2Tx was integrated as a nanoplatform to immobilise enzyme sarcosine oxidase (SOx) onto the interface of screen-printed carbon electrodes (SPCEs). A miniaturised, portable, and cost-effective nanobiosensor was constructed using chitosan as a biocompatible glue for the ultrasensitive detection of prostate cancer biomarker sarcosine. The fabricated device was characterised with energy-dispersive X-ray spectroscopy (EDX), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Sarcosine was detected indirectly via the amperometric detection of H2O2 formed during enzymatic reaction. The nanobiosensor could detect sarcosine down to 7.0 nM with a maximal peak current output at 4.10 ± 0.35 × 10-5 A using only 100 µL of a sample per measurement. The assay run in 100 µL of an electrolyte showed the first linear calibration curve in a concentration window of up to 5 µM with a slope of 2.86 µA·µM-1, and the second linear calibration curve in the range of 5-50 µM with a slope of 0.32 ± 0.01 µA·µM-1 (R2 = 0.992). The device provided a high recovery index of 92.5% when measuring an analyte spiked into artificial urine, and could be used for detection of sarcosine in urine for at least a period of 5 weeks after the preparation.

10.
Anal Chim Acta ; 1242: 340794, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36657889

RESUMO

In this study, an assay for detection of the cancer biomarker Thomsen-nouvelle (Tn) antigen on the ELISA plates format was designed and developed. The effects of size and the interfacial density of the negative charge of magnetic beads (MBs) on the specific sensitivity of the bioaffinity interaction were studied. In particular, glyconanoconjugate, i.e. glycan Tn antigen conjugated to bovine serum albumin (BSA) was covalently immobilised on MBs for the bioaffinity detection of anti-Tn antibodies as cancer biomarkers. Six different MBs were used in the study, i.e. carboxy-modified MBs of 250 nm, 500 nm, 1000 nm and 2800 nm and epoxy-modified MBs of 2800 nm and 4500 nm. In order to evaluate which MBs are the best suited for detection of the analyte anti-Tn antibodies, sensitivities of detection (slopes from calibration curves) were calculated. Next, specific sensitivities were calculated for each type of MBs as a ratio of sensitivity of detection to the mass of MBs. From zeta potential ζ for each type of MBs, the interfacial charge density on MBs was calculated, expressed as the density of zeta potential ζd (ratio of zeta potential to surface area of MBs, i.e. ζd = Î¶/A). Then, we evaluated the effect of size and ζd on the specific sensitivity of detection of anti-Tn antibodies in order to understand the immobilisation process on nanoscale. We also identified an optimal value of ζd on MBs; this was essential to achieve highly sensitive detection of the analyte, which made it possible to attain limit of detection (LOD) of (0.31 ± 0.01) ng mL-1 or (2.10 ± 0.04) pM for analyte detection. In addition, the optimal assay configuration was highly selective and enabled reliable detection of the analyte in human serum with a recovery index in the range of 102-104%.


Assuntos
Antígenos Glicosídicos Associados a Tumores , Magnetismo , Nanoconjugados , Humanos , Fenômenos Magnéticos , Soroalbumina Bovina , Nanoconjugados/química , Antígenos Glicosídicos Associados a Tumores/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA