Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 347
Filtrar
1.
ASAIO J ; 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39321089

RESUMO

Bleeding complications have emerged as major causes of morbidity and mortality in patients with implantable left ventricular assist devices (LVAD). We hypothesized that the hemodynamics after LVAD implantation may influence the occurrence of bleeding complications after LVAD implantation. We retrospectively evaluated 78 patients who underwent continuous-flow LVAD implantation and hemodynamic ramp test after LVAD implantation between July 2017 and July 2023 at Osaka University. The bleeding complication occurred in 13 patients. The rates of freedom from bleeding complications at 1, 3, and 5 years were 94%, 85%, and 74%. Gastrointestinal bleeding, nose bleeding, and intraperitoneal hemorrhage occurred in six, three, and two patients, respectively. Preoperative average brachial-ankle pulse wave velocity (baPWV) was positively associated with bleeding complication (1,276 ± 280 vs. 1,098 ± 190 cm/s p = 0.04). In the hemodynamic ramp test, systemic vascular resistance (SVR) in patients with bleeding complications was higher than that in patients without bleeding complications (SVR: 1,359 ± 341 vs. 1,150 ± 217 dyne sec/cm5, p = 0.01). High preoperative baPWV and high SVR in the hemodynamic ramp test were significantly associated with bleeding complications after LVAD implantation. Arteriosclerosis is a risk factor for bleeding complications after LVAD implantation.

2.
Vaccine ; 42(23): 126221, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39180977

RESUMO

Poor post-vaccination production of antibody against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a concern among solid organ transplant (SOT) recipients. Furthermore, the timing and kinetics of antibody titers after the second vaccine dose are unknown. We conducted a multicenter prospective observational study that included 614 SOT recipients: 460 kidney, 53 heart, 50 liver, 20 lung, and 31 simultaneous pancreas-kidney (SPK). The participants received two doses of the mRNA vaccine (Pfizer BNT162b2 or Moderna mRNA-1273), as indicated. Serum samples were collected before the first and second vaccinations and at 1, 3, and 6 months after the second vaccine dose, which were then assessed for SARS-CoV-2 antibodies. The overall seropositivity rate was 43% at 1 month after administration of the second vaccine dose; it gradually increased to 68% at 3 months after second dose administration and to 70% at 6 months. In addition, recipient of kidney, lung or SPK transplants had lower antibody titers at the 3- and 6-month time points than did the other recipients. SOT recipients acquired SARS-CoV-2 S-IgG antibodies slowly, and the peak titer differed significantly from that of the general population.


Assuntos
Anticorpos Antivirais , Vacina BNT162 , Vacinas contra COVID-19 , COVID-19 , Transplante de Órgãos , SARS-CoV-2 , Transplantados , Humanos , Anticorpos Antivirais/sangue , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , COVID-19/prevenção & controle , COVID-19/imunologia , SARS-CoV-2/imunologia , Vacina BNT162/imunologia , Vacina BNT162/administração & dosagem , Idoso , Adulto , Vacinas contra COVID-19/imunologia , Vacinas contra COVID-19/administração & dosagem , Vacina de mRNA-1273 contra 2019-nCoV/imunologia , Vacina de mRNA-1273 contra 2019-nCoV/administração & dosagem , Imunoglobulina G/sangue , Vacinação
6.
Circ J ; 88(4): 539-548, 2024 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-38447968

RESUMO

BACKGROUND: The introduction of transcatheter edge-to-edge repair for moderate-to-severe or severe mitral regurgitation (MR) utilizing the MitraClip system became reimbursed and clinically accessible in Japan in April 2018. This study presents the 2-year clinical outcomes of all consecutively treated patients who underwent MitraClip implantation in Japan and were prospectively enrolled in the Japanese Circulation Society-oriented J-MITRA registry. METHODS AND RESULTS: Analysis encompassed 2,739 consecutive patients enrolled in the J-MITRA registry with informed consent (mean age: 78.3±9.6 years, 1,550 males, STS risk score 11.7±8.9), comprising 1,999 cases of functional MR, 644 of degenerative MR and 96 in a mixed group (DMR and FMR). The acute procedure success rate was 88.9%. After MitraClip implantation, >80% exhibited an MR grade ≤2+ and the trend was sustained over the 2 years. Within this observation period, the mortality rate was 19.3% and the rate of heart failure readmissions was 20.6%. The primary composite endpoint, inclusive of cardiovascular death and heart failure readmission, was significantly higher in patients with functional MR than in with degenerative MR (32.0% vs. 17.5%, P<0.001). CONCLUSIONS: The 2-year clinical outcomes after MitraClip implantation were deduced from comprehensive data within an all-Japan registry.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Dados de Saúde Coletados Rotineiramente , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
7.
Kyobu Geka ; 77(3): 217-221, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465495

RESUMO

A 51-year-old man visited to our hospital because of chest discomfort and hematemesis. He was diagnosed with Mallory-Weiss syndrome and followed in outpatient clinic. One week later, he visited our hospital again for fever and discomfort. Chest computed tomography (CT) showed a foreign body perforated in the mediastinum in the upper esophagus, and he was urgently hospitalized for surgical removal of esophageal foreign body. Before surgery he vomited the esophageal foreign body with a lot of blood. Hematemesis was stopped spontaneously and contrast-enhanced CT revealed a pseudoaneurysm in the distal aortic arch, so thoracic endovascular aortic repair (TEVAR) was performed to prevent rupture. Esophageal endoscopy found that the site of esophageal injury healed spontaneously, so the patient was followed conservatively with antibiotics. He was discharged on postoperative day 18 uneventfully. TEVAR was an effective treatment for aortic injury caused by esophageal foreign body in our case.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Corpos Estranhos , Masculino , Humanos , Pessoa de Meia-Idade , Hematemese/complicações , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Doenças da Aorta/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia
8.
J Artif Organs ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38396197

RESUMO

PURPOSE: Bleeding complication is a critical risk factor for outcomes of acute heart failure patients requiring mechanical circulatory support (MCS), including percutaneous catheter-type heart pumps (Impella). The Japanese registry for Percutaneous Ventricular Assist Device (J-PVAD) is an ongoing, large-scale, real-world registry to characterize Japanese patients requiring Impella. Here we analyzed bleeding complication profiles in patients who received Impella. METHODS: All consecutive Japanese patients who received Impella from October 2017 to January 2020 were enrolled. The 30-day survival and bleeding complications were analyzed. RESULTS: A total of 1344 patients were included: 653 patients received Impella alone, 685 patients received a combination of veno-arterial extracorporeal membrane oxygenation and Impella (ECPELLA), and 6 patients had failed Impella delivery. Overall 30-day survival was 67.0%, with Impella alone at 81.9% and ECPELLA at 52.7%. Overall bleeding/hematoma adverse events with a relation or not-excluded relation to Impella was 6.92%. Among them, the rates of hematoma and bleeding from medical device access sites were 1.41% and 4.09%, respectively. There was no difference between etiologies for these events. CONCLUSION: This study represents the first 3-year survival and the safety profile focused on bleeding adverse events from the J-PVAD registry. The results show that the real-world frequency of bleeding adverse events for patients who received Impella was an expected range from previous reports, and future real-world studies should aim to expand this data set to improve outcomes and adverse events.

9.
Eur Heart J Case Rep ; 8(1): ytad557, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38192270

RESUMO

Background: Heart transplantation is the gold standard therapy for end-stage heart failure; however, it is limited by a shortage of available donors. In recent years, heart transplantations have been performed using marginal donor hearts with valvular and/or congenital cardiac abnormalities. Case summary: A 60-year-old woman with acromegalic cardiomyopathy underwent left ventricular assist device implantation and aortic valve (AV) closure 4 years prior. After 2 months, repeat AV closure and omental flap transposition were performed. During the outpatient follow-up, the patient developed recurrent severe AV regurgitation and bacteraemia-induced subarachnoid haemorrhage. She underwent urgent heart transplantation using a marginal donor heart with preserved cardiac function, mild pulmonary valve stenosis, and regurgitation after pulmonary valve-sparing tetralogy of Fallot (TOF) repair. An anatomical anastomosis was possible. She had no signs of infection, heart failure, arrhythmia, or immune rejection 15 months after the heart transplantation. Discussion: In this case, the donor heart with repaired TOF did not require pulmonary valve replacement and was anatomically intact. Donor hearts with repaired TOF that are expected to have long-term durability in terms of cardiac function may be used for successful heart transplantations. The repair of marginal donor hearts creates an opportunity to increase the number of viable donors.

10.
ASAIO J ; 70(4): 258-263, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029755

RESUMO

Fulminant myocarditis requiring peripheral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has a high mortality rate. We investigated clinical outcomes of combined use of VA-ECMO and percutaneous left ventricular assist device (VAD) (Impella) for fulminant myocarditis in 104 consecutive patients enrolled in the Japan Registry for Percutaneous VAD (J-pVAD) between October 2017 and January 2020. Patients were followed until hospital discharge and predictors of survival were analyzed with a Cox proportional hazards model. The median support duration of combined use of VA-ECMO and Impella (ECMO/Impella) was 6 days, and the median left ventricular ejection fraction improved from 15% to 52% during support ( p < 0.0001). Overall, 66 patients (63%) survived to discharge. Multivariate analysis revealed ECMO/Impella support at a transplant center as an independent predictor of survival ( p = 0.0231). Patients treated at transplant centers had better 60 days survival rates when compared to nontransplant centers (83% vs. 55%, p = 0.005). However, baseline characteristics and treatment strategies differed between the two groups. This real-world national registry database suggested the difference in survival after ECMO/Impella support for fulminant myocarditis between transplant and nontransplant centers, which may indicate hospital variations regarding patient management, although further controlled studies are needed.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Miocardite , Humanos , Miocardite/cirurgia , Miocardite/etiologia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Choque Cardiogênico/terapia
11.
J Artif Organs ; 27(3): 293-296, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38157138

RESUMO

The patient was diagnosed with perimembranous ventricular septal defect (VSD). She underwent VSD closure and muscle bundle resection across right ventricular outflow tract at the age of 3 months. Since then, she had suffered from severe heart failure and complete heart block. Permanent pacemaker generator was implanted in the left hypochondrium. She was depended on continuous catecholamine administration, so transferred to our hospital for further management. On arrival, her body weight was 5686 g (- 2.7 SD). She underwent Excor pediatric left ventricular assist device implantation at the age of 9 months. Because the position of the left ventricular assist device cannula interfered with the pacemaker, herein, the pacemaker pocket was newly created in the left thoracic cavity. An 1 mm in thickness of expanded polytetrafluoroethylene sheet was trimmed and sutured under the anterolateral wall of left thoracic cavity as a pacemaker pocket. Bipolar ventricular lead was sutured on left ventricular apex and basal wall to face each other, mimicking cardiac regeneration therapy. Even though she unfortunately required right diaphragmatic plication for iatrogenic phrenic nerve palsy, her respiratory function was well maintained; therefore, secondary right heart failure was not observed. Her cardiopulmonary function was quite stable until post-operative day 275 when the patient was transferred to another hospital for heart transplantation.


Assuntos
Bloqueio Cardíaco , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Feminino , Lactente , Bloqueio Cardíaco/terapia , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/cirurgia , Comunicação Interventricular/cirurgia
12.
JTCVS Open ; 15: 211-219, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808015

RESUMO

Objective: In patients with ischemic cardiomyopathy, coronary artery bypass grafting ensures better survival than medical therapy. However, the long-term clinical impact of complete revascularization remains unclear. This observational study aimed to evaluate the effects of complete revascularization on long-term survival and left ventricular functional recovery in patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting. Methods: We retrospectively reviewed outcomes of 498 patients with ischemic cardiomyopathy who underwent complete (n = 386) or incomplete (n = 112) myocardial revascularization between 1993 and 2015. The baseline characteristics were adjusted using inverse probability of treatment weighting to reduce the impact of treatment bias and potential confounding. The mean follow-up duration was 77.2 ± 42.8 months in survivors. Results: The overall 5-year survival rate (complete revascularization, 72.5% vs incomplete revascularization, 57.9%, P = .03) and freedom from all-cause death and/or readmission due to heart failure (54.5% vs 40.1%, P = .007) were significantly greater in patients with complete revascularization than those with incomplete revascularization. After adjustments using inverse probability of treatment weighting, the complete revascularization group demonstrated a lower risk of all-cause death (hazard ratio, 0.61; 95% confidence interval, 0.43-0.86; P = .005) and composite adverse events (hazard ratio, 0.59; 95% confidence interval, 0.44-0.79; P < .001) and a greater improvement in the left ventricular ejection fraction 1-year postoperatively (absolute change: 11.0 ± 11.9% vs 8.3 ± 11.4%, interaction effect P = .05) than the incomplete revascularization group. Conclusions: In patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting, complete revascularization was associated with better long-term outcomes and greater left ventricular functional recovery and should be encouraged whenever possible.

13.
J Am Heart Assoc ; 12(17): e030819, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37646217

RESUMO

Background In patients with cardiogenic shock (CS), acute myocardial infarction (AMI) is the most common cause, and a percutaneous microaxial ventricular assist device (Impella, Abiomed, Danvers, MA) is a choice for temporary mechanical circulatory support. However, data are limited on complications and outcomes of Impella treatment in patients with CS with and without AMI. Methods and Results Using nationwide prospective registry data in Japan, we included a total of 2047 patients with CS in whom the Impella devices were successfully placed between February 2020 and December 2021. Patients were divided into 2 groups according to the primary indication for the Impella use: AMI versus non-AMI. The primary end point was a composite of in-hospital all-cause death and major complications. Of the 2047 patients, the Impella was indicated for AMI in 1337 (65.3%). In the group without AMI, myocarditis was the leading cause of CS. Patients with AMI-CS were older and more likely to have cardiovascular risk factors than those with non-AMI-CS. The rates of in-hospital mortality (46.0% versus 43.9%, P=0.38) and major complications (35.2% versus 34.7%, P=0.85) were similar between the 2 groups. Overall, multivariable analysis identified older age, higher body mass index, previous transient ischemic attack or stroke, out-of-hospital cardiac arrest, and the Impella 5.0 as factors significantly associated with the primary end point. Conclusions The use of Impella in patients with and without AMI was related to similar clinical outcomes with high mortality and complication rates. Further studies are needed to identify patients who may benefit from the Impella devices in CS. Registration URL: https://www.umin.ac.jp/english. Identifier: UMIN000033603.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Humanos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Índice de Massa Corporal , Fatores de Risco de Doenças Cardíacas , Coração Auxiliar/efeitos adversos
14.
Eur Heart J Case Rep ; 7(8): ytad340, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37547367

RESUMO

Background: The number of diagnosed cases of anomalous origin of the left main coronary artery from the pulmonary artery (ALCAPA) in adults has increased substantially because of modern advances in non-invasive cardiac imaging. Here, we report successful surgical repair in an adult patient with ALCAPA complicated by severe mitral regurgitation (MR) and persistent atrial fibrillation. Case summary: ALCAPA syndrome was detected in a 65-year-old Asian woman with persistent atrial fibrillation by coronary computed tomographic angiography. An echocardiogram revealed severe MR caused by annular dilation, atrial enlargement, and posterior mitral leaflet tethering. In addition to ALCAPA repair, mitral valve repair and Cox-Maze IV cryoablation were performed. Mitral valve repair was performed using augmentation with an autologous pericardial patch in the posterior leaflet and ring annuloplasty. Discussion: Because the mechanism of MR with ALCAPA in an adult varies by comorbidity, mitral valve repair should be performed according to the valvular and subvalvular morphologies. It is essential to develop strategies that provide adequate myocardial protection during the surgical treatment of ALCAPA considering coronary steal and non-coronary collateral blood flow.

15.
ASAIO J ; 69(12): 1056-1064, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549664

RESUMO

Few studies have focused on the clinical outcomes and risk factors of left ventricular assist device (LVAD) pump infection, and no standard treatment for LVAD pump infection has been established. Therefore, we used a therapeutic flowchart to manage LVAD pump infections. We retrospectively evaluated 220 patients who underwent continuous-flow LVAD implantation between January 2005 and March 2021 at Osaka University, Japan. First, we performed wound debridement, negative-pressure wound therapy, antibiotic treatment, and omental flap transposition. Subsequently, we administered conservative treatment, scheduled implantable LVAD exchange, or emergent removal of the implantable LVAD and exchange for extracorporeal LVAD or percutaneous LVAD (IMPELLA). Pump infections occurred in 32 patients. The survival rates of patients with pump infections during LVAD support were 93%, 74%, and 61% at 180 days, 1 year, and 2 years after LVAD pump infection, respectively. Fifteen patients underwent successful heart transplantation. Bridge-to-bridge surgery, preoperative use of venoarterial extracorporeal membrane oxygenation or percutaneous LVAD, high lactate dehydrogenase levels, and driveline infection were significantly associated with pump infection. Our study reveals that poor preoperative condition and driveline infection were significant risk factors for LVAD pump infection.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
16.
J Artif Organs ; 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37468735

RESUMO

During continuous-flow left ventricular assist device (CF-LVAD) support, hemodynamic shear stress causes a burden on aortic valve (AV) leaflets, leading to de novo aortic insufficiency (AI). This study investigated the influence of preoperative hemodynamic parameters on de novo AI in CF-LVAD recipients. We reviewed 125 patients who underwent CF-LVAD implantation without concomitant AV surgery between 2005 and 2018. De novo AI was defined as moderate or severe AI in those with none or trivial preoperative AI. During mean 30 ± 16 months of CF-LVAD support, de novo AI-free rate was 86% and 67% at 1 and 2 years, respectively. Multivariable analysis showed that higher right ventricular stroke work index (RVSWI) (hazard ratio, 1.12 /g/m2/beat; 95% confidence interval, 1.00-1.20; p = 0.047) and trivial grade AI (hazard ratio, 2.8; 95% confidence interval, 1.2-6.4; p = 0.020) were independent preoperative risk factors for de novo AI. The longitudinal analysis using generalized mixed effects model showed that higher RVSWI was associated with continuous AV closure after LVAD implantation (Odd ratio, 1.20/g/m2/beat; 95% confidence interval, 1.00-1.43 /g/m2/beat; p = 0.047). Right heart catheterization revealed that preoperative RVSWI was positively correlated with postoperative pump flow index in patients with continuously closed AV (r = 0.44, p = 0.04, n = 22). Preoperative higher RVSWI was a significant risk factor for de novo AI following CF-LVAD implantation. In patients with preserved right ventricular function, postoperative higher pump flow may affect AI development via hemodynamic stress on the AV.

17.
Artif Organs ; 47(6): 914-924, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37140177

RESUMO

Globalization in Asia and consequent strengthening of healthcare economic factors in tandem with an increasing heart failure (HF) population have enhanced potential for development and progress in the fields of HF medicine and mechanical circulatory support (MCS). In Japan, there are unique opportunities to investigate the outcome of acute and chronic MCS and a national registry for percutaneous and implantable left ventricular assist device (LVAD) including Impella pumps has been established. A Peripheral extracorporeal membrane oxygenation (ECMO) for acute MCS has been used in more than 7000 patients annually and Impella usage in more than 4000 patients over the past 4 years was noted. Recently, a novel centrifugal pump with hydrodynamically levitated impeller was developed and approved for mid-term extracorporeal circulatory support. In terms of chronic MCS more than 1200 continuous flow LVADs have been implanted during the past decade, and 2-year survival rate after primary LVAD implantation is 91%. Because of donor organ shortage, more than 70% of heart transplant recipients required LVAD support for more than 3 years and prevention and treatment of complications during long-term LVAD support have become important. Five important topics including hemocompatibility-related complications, LVAD infections, aortic valve insufficiency, right ventricular failure and cardiac recovery during LVAD support are discussed in this review for improving clinical outcomes. Findings from Japan will continue to provide useful information regarding MCS for the Asia-Pacific region and beyond.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Adulto , Japão/epidemiologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
18.
Circ J ; 87(8): 1103-1111, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37258218

RESUMO

BACKGROUND: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.Methods and Results: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score. CONCLUSIONS: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
19.
Artif Organs ; 47(7): 1223-1225, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37114775

RESUMO

Pump pocket infection (PPI) is a refractory condition that can cause lethal complications in patients with a left ventricular assist device (LVAD). We report a case of PPI after LVAD implantation for ischemic cardiomyopathy that was successfully treated with staged pump reimplantation into the left ventricular anterior wall with the pedicled omental transfer. Major modification of the pump implantation site might be a useful strategy for local infection control of severe PPI.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Isquemia Miocárdica , Humanos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Isquemia Miocárdica/etiologia , Omento , Estudos Retrospectivos
20.
JTCVS Open ; 13: 163-175, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37063141

RESUMO

Objectives: The study objectives were to determine the incidence, predictors, and clinical impact of ventricular arrhythmias after coronary artery bypass grafting and to evaluate the impact of implantable cardioverter defibrillators on the survival of patients with ventricular arrhythmias. Methods: We enrolled 498 patients with a left ventricular ejection fraction of 40% or less who underwent coronary artery bypass grafting between 1993 and 2015. Clinical follow-up was completed in 94.0% of patients, with a median follow-up of 58.4 months. Results: Overall, 212 patients (43%) died, mainly of heart failure (n = 54, 10.8%) or sudden cardiac death (n = 40, 8.0%). The sudden cardiac death rate was highest during the first 6 months, with a monthly rate of 0.37%. Overall, 99 patients (20%) developed postoperative ventricular arrhythmias, and implantable cardioverter defibrillator was implanted in 55 patients. Previous ventricular arrhythmias (hazard ratio, 3.22; 95% confidence interval, 1.98-5.24; P < .001), left ventricular end-systolic dimension (hazard ratio, 1.07; 95% confidence interval, 1.04-1.10; P < .001), and myocardial infarction in the left anterior descending artery territory (hazard ratio, 1.73; 95% confidence interval, 1.10-2.73; P = .02) were independent predictors of postoperative ventricular arrhythmias. Notably, the 5-year survival of patients with ventricular arrhythmias who received an implantable cardioverter defibrillator was significantly higher than that of patients with ventricular arrhythmias who did not receive it (76.1% vs 22.7%, P < .001) and was comparable to that of patients without ventricular arrhythmias (76.1% vs 73.6%, P = .98). Conclusions: Sudden cardiac death affects a significant proportion of patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting, most frequently within 6 months postoperatively. To prevent sudden cardiac death, earlier implantable cardioverter defibrillator implantation should be indicated for high-risk patients with scars in the left anterior descending artery territory and excessive left ventricular remodeling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA