Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
Artigo em Inglês | MEDLINE | ID: mdl-38819348

RESUMO

BACKGROUND: A partial delineation of targets for ablation of ventricular tachycardia (VT) during a stable rhythm is likely responsible for a suboptimal success rate. The abnormal low-voltage near-field functional components may be hidden within the high-amplitude far-field signal. OBJECTIVES: The aim of this study was to evaluate the benefit and feasibility of functional substrate mapping using a full-ventricle S3 protocol and to assess its colocalization with arrhythmogenic conducting channels (CCs) on late gadolinium enhancement cardiac magnetic resonance. METHODS: An S3 mapping protocol with a drive train of S1 followed by S2 (effective refractory period + 30 ms) and S3 (effective refractory period + 50 ms) from the right ventricular apex was performed in 40 consecutive patients undergoing scar-related VT ablation. Deceleration zones (DZs) and areas of late potentials (LPs) were identified for all maps. A preprocedural noninvasive substrate assessment was done using late gadolinium enhancement cardiac magnetic resonance and postprocessing with automated CC identification. RESULTS: The S3 protocol was completed in 34 of the 40 procedures (85.0%). The S3 protocol enhanced the identification of VT isthmus on the basis of DZ (89% vs 62%; P < 0.01) and LP (93% vs 78%; P = 0.04) assessment. The percentage of CCs unmasked by DZs and LPs using S3 maps was significantly higher than the ones using S2 and S1 maps (78%, 65%, and 48% [P < 0.001] and 88%, 81%, and 68% [P < 0.01], respectively). The functional substrate identified during S3 activation mapping was significantly more extensive than the one identified using S2 and S1, including a greater number of DZs (2.94, 2.47, and 1.82, respectively; P < 0.001) and a wider area of LPs (44.1, 38.2, and 29.4 cm2, respectively; P < 0.001). After VT ablation, 77.9% of patients have been VT free during a median follow-up period of 13.6 months. CONCLUSIONS: The S3 protocol was feasible in 85% of patients, allows a better identification of targets for ablation, and might improve VT ablation results.

3.
Heart Rhythm ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38670249

RESUMO

BACKGROUND: Voltage mapping could identify the conducting channels potentially responsible for ventricular tachycardia (VT). Standard thresholds (0.5-1.5 mV) were established using bipolar catheters. No thresholds have been analyzed with high-density mapping catheters. In addition, channels identified by cardiac magnetic resonance (CMR) has been proven to be related with VT. OBJECTIVE: The purpose of this study was to analyze the diagnostic yield of a personalized voltage map using CMR to guide the adjustment of voltage thresholds. METHODS: All consecutive patients with scar-related VT undergoing ablation after CMR (from October 2018 to December 2020) were included. First, personalized CMR-guided voltage thresholds were defined systematically according to the distribution of the scar and channels. Second, to validate these new thresholds, a comparison with standard thresholds (0.5-1.5 mV) was performed. Tissue characteristics of areas identified as deceleration zones (DZs) were recorded for each pair of thresholds. In addition, the relation of VT circuits with voltage channels was analyzed for both maps. RESULTS: Thirty-two patients were included [mean age 66.6 ± 11.2 years; 25 (78.1%) ischemic cardiomyopathy]. Overall, 52 DZs were observed: 44.2% were identified as border zone tissue with standard cutoffs vs 75.0% using personalized voltage thresholds (P = .003). Of the 31 VT isthmuses detected, only 35.5% correlated with a voltage channel with standard thresholds vs 74.2% using adjusted thresholds (P = .005). Adjusted cutoff bipolar voltages that better matched CMR images were 0.51 ± 0.32 and 1.79 ± 0.71 mV with high interindividual variability (from 0.14-1.68 to 0.7-3.21 mV). CONCLUSION: Personalized voltage CMR-guided personalized voltage maps enable a better identification of the substrate with a higher correlation with both DZs and VT isthmuses than do conventional voltage maps using fixed thresholds.

4.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636930

RESUMO

BACKGROUND: Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE: This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS: A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS: Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 ± 0.15 m/s vs 1.64 ± 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 ± 0.22 m/s vs 1.08 ± 0.26 m/s; P < .0001). This average conduction velocity of the "slowest" segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P = .002). CONCLUSION: This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy.

5.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38262674

RESUMO

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Frequência Cardíaca/fisiologia , Arritmias Cardíacas , Cicatriz/patologia , Ablação por Cateter/métodos
6.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38256411

RESUMO

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Projetos Piloto , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração
7.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37819047

RESUMO

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Miocárdio/patologia , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Cicatriz/patologia , Estudos Prospectivos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/patologia , Espectroscopia de Ressonância Magnética
8.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37751383

RESUMO

AIMS: Recurrence of arrhythmia after catheter ablation of atrial fibrillation (AF) in the form of atypical atrial flutter (AFL) is common among a significant number of patients and often requires redo ablation with limited success rates. Identifying patients at high risk of AFL after AF ablation could aid in patient selection and personalized ablation approach. The study aims to assess the relationship between pre-existing atrial cardiomyopathy and the occurrence of AFL following AF ablation. METHODS AND RESULTS: We analysed a cohort of 1007 consecutive AF patients who underwent catheter ablation and were included in a prospective registry. Patients who did not have baseline cardiac magnetic resonance imaging and late gadolinium enhancement (LGE-CMR) or did not experience any recurrences were excluded. A total of 166 patients were included gathering 56 patients who underwent re-ablation due to AFL recurrences and 110 patients who underwent re-ablation due to AF recurrences (P = 0.11). A multiparametric assessment of atrial cardiomyopathy was based on basal LGE-CMR, including left atrial (LA) volume, LA sphericity, and global and segmental LA fibrosis using semiautomated post-processing software. Out of the initial cohort of 1007 patients, AFL and AF occurred in 56 and 110 patients, respectively. An age higher than 65 [odds ratio (OR) = 5.6, 95% confidence interval (CI): 2.2-14.4], the number of previous ablations (OR = 3.0, 95% CI: 1.2-7.8), and the management of ablation lines in the index procedure (OR = 2.5, 95% CI: 1.0-6.3) were independently associated with AFL occurrence. Furthermore, several characteristics assessed by LGE-CMR were identified as independent predictors of AFL recurrence after the index ablation for AF, such as enhanced LA sphericity (OR = 1.3, 95% CI: 1.1-1.6), LA global fibrosis (OR = 1.03, 95% CI: 1.01-1.07), and increased fibrosis in the lateral wall (OR = 1.03, 95% CI: 1.01-1.04). CONCLUSION: Advanced atrial cardiomyopathy assessed by LGE-CMR, such as increased LA sphericity, global LA fibrosis, and fibrosis in the lateral wall, is independently associated with arrhythmia recurrence in the form of AFL following AF ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
9.
JACC Clin Electrophysiol ; 9(6): 779-789, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37380313

RESUMO

BACKGROUND: A new functional mapping strategy based on targeting deceleration zones (DZs) has become one of the most commonly used strategies within the armamentarium of substrate-based ablation methods for ventricular tachycardia (VT) in patients with structural heart disease. The classic conduction channels detected by voltage mapping can be accurately determined by cardiac magnetic resonance (CMR). OBJECTIVES: The purpose of this study was to analyze the evolution of DZs during ablation and their correlation with CMR. METHODS: Forty-two consecutive patients with scar-related VT undergoing ablation after CMR in Hospital Clinic (October 2018-December 2020) were included (median age 65.3 ± 11.8 years; 94.7% male; 73.7% ischemic heart disease). Baseline DZs and their evolution in isochronal late activation remaps were analyzed. A comparison between DZs and CMR conducting channels (CMR-CCs) was realized. Patients were prospectively followed for VT recurrence for 1 year. RESULTS: Overall, 95 DZs were analyzed, 93.68% of which were correlated with CMR-CCs: 44.8% located in the middle segment and 55.2% located in the entrance/exit of the channel. Remapping was performed in 91.7% of patients (1 remap: 33.3%, 2 remaps: 55.6%, and 3 remaps: 2.8%). Regarding the evolution of DZs, 72.2% disappeared after the first ablation set, with 14.13% not ablated at the end of the procedure. A total of 32.5% of DZs in remaps correlated with a CMR-CCs already detected, and 17.5% were associated with an unmasked CMR-CCs. One-year VT recurrence was 22.9%. CONCLUSIONS: DZs are highly correlated with CMR-CCs. In addition, remapping can lead to the identification of hidden substrate initially not identified by electroanatomic mapping but detected by CMR.


Assuntos
Desaceleração , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Imageamento por Ressonância Magnética , Coração , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Espectroscopia de Ressonância Magnética
10.
Europace ; 25(3): 989-999, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36607130

RESUMO

AIMS: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics. METHODS AND RESULTS: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01-1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18-2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04-1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07-1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15-2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity. CONCLUSION: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Cicatriz/etiologia , Cicatriz/complicações , Meios de Contraste , Gadolínio , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos
11.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36607529

RESUMO

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Assuntos
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudos Transversais , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Eletrocardiografia , Estimulação Cardíaca Artificial , Resultado do Tratamento
12.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36654964

RESUMO

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

13.
Rev Esp Cardiol (Engl Ed) ; 76(3): 173-182, 2023 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35809892

RESUMO

INTRODUCTION AND OBJECTIVES: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. METHODS: A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. RESULTS: The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. CONCLUSIONS: An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Cicatriz/patologia , Cicatriz/cirurgia , Meios de Contraste , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/cirurgia , Fibrose , Ablação por Cateter/métodos , Gadolínio , Espectroscopia de Ressonância Magnética
14.
J Interv Card Electrophysiol ; 66(1): 15-25, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35195814

RESUMO

BACKGROUND: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. METHODS: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016-2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. RESULTS: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02-2 mV) and 1.84 (0.3-6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). CONCLUSIONS: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Pessoa de Meia-Idade , Idoso , Cicatriz , Lipopolissacarídeos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Isquemia Miocárdica/complicações , Ablação por Cateter/efeitos adversos
16.
Rev Esp Cardiol (Engl Ed) ; 76(3): 183-196, 2023 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36539182

RESUMO

Magnetic resonance has become a first-line imaging modality in various clinical scenarios. The number of patients with different cardiovascular devices, including cardiac implantable electronic devices, has increased exponentially. Although there have been reports of risks associated with exposure to magnetic resonance in these patients, the clinical evidence now supports the safety of performing these studies under specific conditions and following recommendations to minimize possible risks. This document was written by the Working Group on Cardiac Magnetic Resonance Imaging and Cardiac Computed Tomography of the Spanish Society of Cardiology (SEC-GT CRMTC), the Heart Rhythm Association of the Spanish Society of Cardiology (SEC-Heart Rhythm Association), the Spanish Society of Medical Radiology (SERAM), and the Spanish Society of Cardiothoracic Imaging (SEICAT). The document reviews the clinical evidence available in this field and establishes a series of recommendations so that patients with cardiovascular devices can safely access this diagnostic tool.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Cardiopatias , Humanos , Consenso , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
17.
Europace ; 25(2): 360-365, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36125227

RESUMO

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Meios de Contraste , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Gadolínio , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
18.
J Am Heart Assoc ; 11(20): e026028, 2022 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-36216438

RESUMO

Background Left atrial structural remodeling contributes to the arrhythmogenic substrate of atrial fibrillation (AF), but the role of the right atrium (RA) remains unknown. Our aims were to comprehensively characterize right atrial structural remodeling in AF and identify right atrial parameters predicting recurrences after ablation. Methods and Results A 3.0 T late gadolinium enhanced-cardiac magnetic resonance was obtained in 109 individuals (9 healthy volunteers, 100 patients with AF undergoing ablation). Right and left atrial volume, surface, and sphericity were quantified. Right atrial global and regional fibrosis burden was assessed with validated thresholds. Patients with AF were systematically followed after ablation for recurrences. Progressive right atrial dilation and an increase in sphericity were observed from healthy volunteers to patients with paroxysmal and persistent AF; fibrosis was similar among the groups. The correlation between parameters recapitulating right atrial remodeling was mild. Subsequently, remodeling in both atria was compared. The RA was larger than the left atrium (LA) in all groups. Fibrosis burden was higher in the LA than in the RA of patients with AF, whereas sphericity was higher in the LA of patients with persistent AF only. Fibrosis, volume, and surface of the RA and LA, but not sphericity, were strongly correlated. Tricuspid regurgitation predicted right atrial volume and shape, whereas diabetes was associated with right atrial fibrosis burden; sex and persistent AF also predicted right atrial volume. Fibrosis in the RA was mostly located in the inferior vena cava-RA junction. Only right atrial sphericity is significantly associated with AF recurrences after ablation (hazard ratio, 1.12 [95% CI, 1.01-1.25]). Conclusions AF progression associates with right atrial remodeling in parallel with the LA. Right atrial sphericity yields prognostic significance after ablation.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Ablação por Cateter/métodos , Gadolínio , Átrios do Coração , Fibrose , Espectroscopia de Ressonância Magnética
20.
Front Cardiovasc Med ; 9: 912335, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35979023

RESUMO

Background: Substrate-based ablation has become a successful technique for ventricular tachycardia (VT) ablation. High-density (HD) mapping catheters provide high-resolution electroanatomical maps and better discrimination of local abnormal electrograms. The HD Grid Mapping Catheter is an HD catheter with the ability to map orthogonal signals on top of conventional bipolar signals, which could provide better discrimination of the arrhythmic substrate. On the other hand, conventional mapping techniques, such as activation mapping, when possible, help to identify the isthmus of the tachycardia. Aim: The purpose of this study was to compare clinical outcomes after using two different VT ablation strategies: one based on extensive mapping with the HD Grid Mapping Catheter, including VT isthmus analysis, and the other based on pure substrate ablation. Methods: Forty consecutive patients undergoing VT ablation with extensive HD mapping method in the hospital clinic (November 2018-November 2019) were included. Clinical outcomes were compared with a historical cohort of 26 consecutive patients who underwent ablation using a scar dechanneling technique before 2018. Results: The density of mapping points was higher in the extensive mapping group (2370.24 ± 920.78 vs. 576.45 ± 294.46; p < 0.001). After 1 year of follow-up, VT recurred in 18.4% of patients in the extensive mapping group vs. 34.6% of patients in the historical control group (p = 0.14), with a significantly greater reduction of VT burden: VT episodes (81.7 ± 7.79 vs. 43.4 ± 19.9%, p < 0.05), antitachycardia pacing (99.45 ± 2.29 vs. 33.9 ± 102.5%, p < 0.001), and implantable cardioverter defibrillator (ICD) shocks (99 ± 4.5 vs. 64.7 ± 59.9%, p = 0.02). Conclusion: The use of a method based on extensive mapping with the HD Grid Mapping Catheter and VT isthmus analysis allows better discrimination of the arrhythmic substrate and could be associated with a greater decrease in VT burden.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA