Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Gastroenterol Hepatol Bed Bench ; 16(4): 445-450, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38313350

RESUMO

Atypical/complement-mediated hemolytic uremic syndrome (A-HUS/CM-HUS) is a hereditary or sporadic disease with thrombotic microangiopathy (TMA). Diarrhea is a trigger that can cause attacks of CM-HUS. Although there are opinions that complement system activation plays a role in intestinal inflammation in patients with inflammatory bowel disease, the association of TMA with inflammatory bowel disease (IBD) has rarely been reported. In our case, a CM-HUS case that developed without an additional triggering factor in the course of ulcerative colitis (UC) was successfully treated with eculizumab, and then UC remission was also achieved. In this context, we would like to point out that the irregularities in the alternative pathway of the complement system may cause clinical findings in extra-renal organs, and the complement system may also play a role in the pathogenesis of inflammatory bowel disease. In addition, we think that our case may guide further studies on the usability of anti-complement therapies in treating patients with IBD who are resistant to conventional treatments.

2.
Turk J Med Sci ; 53(6): 1863-1869, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38813487

RESUMO

Background and aim: There are over 60,000 hemodialysis (HD) patients in Türkiye, and the number of patients is increasing yearly. Dialysate flow rate (Qd) is a factor in HD adequacy. Approximately 150 L of water are consumed per session to prepare the dialysate. We aimed to investigate whether HD effectiveness can be achieved at a low Qd in different patient groups for the purpose of saving water. Materials and methods: This prospective study included 81 HD patients from 2 centers. The patients underwent an aggregate total of 486 HD sessions, including 3 sessions at a Qd of 500 mL/min and 3 sessions at a Qd of 300 mL/min for each patient. We used online Kt/V readings recorded at the end of each dialysis session to compare the effectiveness of these 2 types of HD session performed at a different Qd. Results: The online Kt/V readings were similar between the standard (500) and low (300) Qd HD (1.51 ± 0.41 and 1.49 ± 0.44, respectively, p = 0.069). In the subgroup analyses, men had higher online Kt/V values at the standard Qd compared to the low Qd (1.35 ± 0.30 and 1.30 ± 0.32, respectively, p = 0.019), but the Kt/V values were not different for women. While the low Qd did not reduce online Kt/V in patients using small surface area dialysis membranes (1.75 ± 0.35 for 300 Qd and 1.75 ± 0.32 for 500 Qd, p = 0.931), it was associated with reduced online Kt/V in patients using large surface area dialysis membranes (1.12 ± 0.25 for 300 Qd and 1.17 ± 0.24 for 500 Qd, p = 0.006). The low Qd did not result in differences in online Kt/V among low-weight patients. However, online Kt/V values were better with the standard Qd in patients weighing 65 kg and above. Conclusion: In our study, dialysis adequacy at a reduced dialysate flow was not inferior for women, patients with low body weight, or patients using small surface area membranes. Individualized HD at a reduced Qd of 300 mL/min in eligible patients can save 48 L of water per HD session and an average of 7500 L of water per year.


Assuntos
Diálise Renal , Humanos , Diálise Renal/métodos , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Água , Adulto , Soluções para Diálise , Falência Renal Crônica/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA