Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563216

RESUMO

OBJECTIVE: Occlusal reconstruction is a critical intervention for patients with dental hard tissue defects, temporomandibular joint (TMJ) disorders, and jaw position abnormalities. Clinical efficiency and outcomes of these procedures have improved with advances in digital technologies. This case report aims to illustrate a comprehensive digital workflow for occlusal reconstruction in a patient with congenital dentition defects, emphasizing the application of digital technologies to enhance treatment outcomes. CLINICAL CONSIDERATIONS: A 28-year-old woman with previously installed porcelain-fused-to-metal bridge restorations presented with a fractured prosthesis and TMJ symptoms. A multidisciplinary approach was adopted involving the use of digital facebow, intraoral scanners, digital smile design, and CAD/CAM technologies. The process included the extraction of defective restorations, temporary restorations to refine jaw position, and final permanent restorations. The digital workflow facilitated precise diagnostics and treatment, culminating in the successful installation of permanent restorations. Regular follow-ups at one- and three-months post-treatment confirmed stable occlusal function and high patient satisfaction. CONCLUSIONS: This case report showcases the potential of multiple digital technologies to streamline complex dental treatments and achieve high-quality results. CLINICAL SIGNIFICANCE: The integration of digital technologies in occlusal reconstruction treatments offers significant benefits in terms of precision, patient comfort, and esthetic outcomes.

2.
Dent Mater ; 40(4): 608-618, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369405

RESUMO

OBJECTIVE: The current dental resin composites often suffer from polymerization shrinkage, which can lead to microleakage and potentially result in recurring tooth decay. This study presents the synthesis of a novel monomer, (3,9-diethyl-1,5,7,11-tetraoxaspiro[5,5]undecane-3,9-diyl)bis(methylene) bis((2-(3-(prop-1-en-2-yl)phenyl)propan-2-yl)carbamate) (DDTU-IDI), and evaluates its effect in the formulation of low-shrinkage dental resin composites. METHODS: DDTU-IDI was synthesized through a two-step reaction route, with the initial synthesis of the required raw material monomer 3,9-diethyl-3,9-dihydroxymethyl-1,5,7,11-tetraoxaspiro-[5,5] undecane (DDTU). The structures were confirmed using Fourier-transform infrared (FT-IR) spectroscopy and hydrogen nuclear magnetic resonance (1HNMR) spectroscopy. Subsequently, DDTU-IDI was incorporated into Bis-GMA-based composites at varying weight percentages (5, 10, 15, and 20 wt%). The polymerization reaction, degree of conversion, polymerization shrinkage, mechanical properties, physicochemical properties and biocompatibility of the low-shrinkage composites were thoroughly evaluated. Furthermore, the mechanical properties were assessed after a thermal cycling test with 10,000 cycles to determine the stability. RESULTS: The addition of DDTU-IDI at 10, 15, and 20 wt% significantly reduced the polymerization volumetric shrinkage of the experimental resin composites, without compromising the degree of conversion, mechanical and physicochemical properties. Remarkably, at a monomer content of 20 wt%, the polymerization shrinkage was reduced to 1.83 ± 0.53%. Composites containing 10, 15, and 20 wt% DDTU-IDI exhibited lower water sorption and higher contact angle. Following thermal cycling, the composites exhibited no significant decrease in mechanical properties, except for the flexural properties. SIGNIFICANCE: DDTU-IDI has favorable potential as a component which could produce volume expansion and increase rigidity in the development of low-shrinkage dental resin composites. The development of low-shrinkage composites containing DDTU-IDI appears to be a promising strategy for reducing polymerization shrinkage, thereby potentially enhancing the longevity of dental restorations.


Assuntos
Alcanos , Metacrilatos , Ácidos Polimetacrílicos , Metacrilatos/química , Ácidos Polimetacrílicos/química , Espectroscopia de Infravermelho com Transformada de Fourier , Polietilenoglicóis/química , Teste de Materiais , Resinas Compostas/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimerização
3.
J Prosthodont ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38305664

RESUMO

PURPOSE: This study aimed to develop and evaluate a simple, non-destructive method for assessing the misfit and passivity of implant-retained prostheses frameworks. MATERIALS AND METHODS: To simulate the rehabilitation of a mandible posterior partially edentulous area using 3-unit screw-retained frameworks supported by two implants were fabricated and divided into the following five groups (n = 10 in each group): OP = one-piece framework cast in Co-Cr with the conventional method (control-group); Co-Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co-Cr CAD-CAM = milled Co-Cr framework; Zir CAD-CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened. Data were analyzed by a two-way ANOVA with repeated measures and Bonferroni correction (α = 0.05). RESULTS: The greatest |X| misfit was observed in the OP group with both screws tightened (290 µm) and one screw tightened (388 and 340 µm). The conventional casting groups sectioned and welded by laser or TIG had lower mean values (235.35 µm, both screws tightened; and 275 µm, one screw tightened) than the OP framework. However, these values still exceeded those of the milled Co-Cr and zirconia frameworks (190 and 216 µm with both screws tightened). Across all reading conditions, every framework subjected to testing consistently maintained vertical |Y| misfit levels below the threshold of 53 µm; however, the milled frameworks exhibited higher vertical misfits than the frameworks obtained by the conventional cast method. CONCLUSIONS: The frameworks, whether cast and sectioned with laser welding or milled from Co-Cr, exhibit improved marginal misfit and enhanced passive fit when compared to other fabrication methods. Additionally, the use of confocal laser scanning microscopy is highly effective for passivity and misfit analysis.

4.
ACS Biomater Sci Eng ; 9(8): 4632-4645, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37486960

RESUMO

Photoactivating dental resin composites have been the most prevailing material for repairing dental defects in various clinical scenarios due to their multiple advantages. However, compared to other restorative materials, the surface of resin-based composites is more susceptible to plaque biofilm accumulation, which can lead to secondary caries and restoration failure. This study introduced different weight fractions (1, 2, 5, 10, and 15%) of magnesium oxide nanoparticles (MgONPs) as antibacterial fillers into dental resin composites. Multifarious properties of the material were investigated, including antibacterial activity against a human salivary plaque-derived biofilm, cytotoxicity on human gingival fibroblasts, mechanical and physicochemical properties as well as the performance when subjected to thermocycling aging treatment. Results showed that the incorporation of MgONPs significantly improved the composites' anti-biofilm capability even at a low amount of 2 wt % without compromising the mechanical, physicochemical, and biocompatibility performances. The results of the thermocycling test suggested certain of aging resistance. Moreover, a small amount of MgONPs possibly made a difference in enhancing photoactivated polymerization and increasing the curing depth of experimental resin composites. Overall, this study highlights the potential of MgONPs as an effective strategy for developing antibacterial resin composites, which may help mitigating cariogenic biofilm-associated secondary caries.


Assuntos
Óxido de Magnésio , Nanopartículas , Humanos , Teste de Materiais , Óxido de Magnésio/farmacologia , Resinas Compostas/farmacologia , Resinas Compostas/química , Nanopartículas/química , Antibacterianos/farmacologia , Antibacterianos/química
5.
J Mech Behav Biomed Mater ; 142: 105847, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37127010

RESUMO

PURPOSE: This study aimed to evaluate the stress distribution and microgap formation in implant assemblies with conical abutments made of different materials under an oblique load. MATERIALS AND METHODS: The mechanical behavior of an implant assembly with a titanium abutment was analyzed and compared with that of an assembly with a Y-TZP abutment using finite element analysis (FEA). A torque of 20 Ncm was first applied to the abutment screw, followed by oblique loads of 10 N-280 N applied to the prosthesis placed on the implant. The maximum stress in the abutment screw, the microgap formation process, and the critical load for bridging the internal implant space were evaluated. RESULTS: No significant difference in stress distribution between the two cases was observed, with the stresses being mainly concentrated at the top half of the screw (the predicted maximum von Mises stress was approximately 1200 MPa at 280 N). The area in contact at the implant-to-abutment interface decreased with increasing load for both abutments, with the critical load for bridging the internal implant space being roughly 140 N. The maximum gap size being was approximately 470 µm with either abutment. CONCLUSION: There was no significant difference in the stress distribution or microgap formed between implant assemblies with titanium and Y-TZP abutments having an internal conical connection.


Assuntos
Implantes Dentários , Análise de Elementos Finitos , Titânio , Torque , Análise do Estresse Dentário , Estresse Mecânico
6.
J Mech Behav Biomed Mater ; 142: 105815, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37068430

RESUMO

Cariogenic bacteria and dental plaque biofilm at prosthesis margins are considered a primary risk factor for failed restorations. Resin cement containing antibacterial agents can be beneficial in controlling bacteria and biofilm. This work aimed to evaluate the impact of incorporating magnesium oxide nanoparticles (MgONPs) as an antibacterial filler into dual-cure resin cement on bacteriostatic activity and physical properties, including mechanical, bonding, and physicochemical properties, as well as performance when subjected to a 5000-times thermocycling regimen. Experimental resin cements containing MgONPs of different mass fractions (0, 2.5%, 5%, 7.5% and 10%) were developed. Results suggested that the inclusion of MgONPs markedly improved the materials' bacteriostatic effect against Streptococcus mutans without compromising the physical properties when its addition reached 7.5 wt%. The mechanical properties of the specimens did not significantly decline after undergoing aging treatment, except for the flexural properties. In addition, the cements displayed good bonding performance and the material itself was not prone to cohesive fracture in the failure mode analysis. Furthermore, MgONPs possibly have played a role in decelerating material aging during thermocycling and enhancing bonding fastness in the early stage of cementation, which requires further investigation. Overall, developing MgONPs-doped resin cements can be a promising strategy to improve the material's performance in inhibiting cariogenic bacteria at restoration margins, in order to achieve a reduction in biofilm-associated secondary caries and a prolonged restoration lifespan.


Assuntos
Colagem Dentária , Nanopartículas , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Óxido de Magnésio/farmacologia , Teste de Materiais , Antibacterianos/farmacologia , Cimentos Dentários
7.
J Esthet Restor Dent ; 32(4): 403-409, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32091666

RESUMO

OBJECTIVE: Evaluate the effects of the scanning techniques and the crystallization in the internal and marginal adaptation of milled lithium disilicate crowns by two techniques computer microtomography analysis. MATERIALS AND METHODS: Sixteen polyurethane teeth prepared for a complete crown were divided into two groups according to the scanner method (n = 8): indirect (IND), dental stone models were scanned with laser-surface scanner, and direct (DIR), digital typodont creates with an intraoral scanner. Internal and marginal gap were evaluated by micro-computed tomography (microCT). The replica technique (RT) was applied for analysis of total volume (TV) and marginal volume (MV) gap in microCT. The data showed normal distribution (Shapiro-Wilk test). One-way ANOVA (scanner techniques) with repeated measures (crystallization) was performed. Multiple comparisons were performed with Bonferroni adjustment (α = .05). RESULTS: The axial gap showed a significant difference between the times (P = .017) for lower values after crystallization. The vertical marginal gap presented a significant difference in times for higher value after crystallization (P = .001). The marginal horizontal gap IND was greater than DIR after crystallization (P = .001) and IND before lower than after crystallization. For TV was not significant difference and MV in DIR was reduction (P = .002) after crystallization. CONCLUSION: Crystallization changes the relationship between the crown and tooth, reducing internal gap and preventing the adequate fit in indirect and direct scanning. CLINICAL SIGNIFICANCE: The measure gap under technological methodology is useful for adjust clinical parameters prosthetic in the CAD/CAM and the applicability of the new possibilities of analysis.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Técnica de Moldagem Odontológica , Porcelana Dentária , Propriedades de Superfície , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA