Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(3Part B): 101308, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39131224

RESUMO

Background: Coronary artery calcium score (CACS) is an established marker of coronary artery disease (CAD) and has been extensively used to stratify risk in asymptomatic individuals. However, the value of CACS in predicting plaque morphology in patients with advanced CAD is less established. The present analysis aims to assess the association between CACS and plaque characteristics detected by near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) imaging in patients with obstructive CAD. Methods: Seventy patients with obstructive CAD underwent coronary computed tomography angiography (CTA) and 3-vessel NIRS-IVUS imaging were included in the present analysis. The CTA data were used to measure the CACS in the entire coronary tree and the segments assessed by NIRS-IVUS, and these estimations were associated with the NIRS-IVUS measurements at a patient and segment level. Results: In total, 65 patients (188 segments) completed the study protocol and were included in the analysis. A weak correlation was noted between the CACS, percent atheroma volume (r = 0.271, P = .002), and the calcific burden measured by NIRS-IVUS (r = 0.648, P < .001) at patient-level analysis. Conversely, there was no association between the CACS and the lipid content, or the incidence of high-risk plaques detected by NIRS. Linear regression analysis at the segment level demonstrated an association between the CACS and the total atheroma volume (coefficient, 0.087; 95% CI, 0.024-0.149; P = .008) and the calcific burden (coefficient, 0.117; 95% CI, 0.048-0.186; P = .001), but there was no association between the lipid content or the incidence of high-risk lesions. Conclusions: In patients with obstructive CAD, the CACS is not associated with the lipid content or plaque phenotypes. These findings indicate that the CACS may have a limited value for screening or stratifying cardiovascular risk in symptomatic patients with a high probability of CAD.

2.
Radiology ; 312(1): e232731, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39012246

RESUMO

Background Current clinical imaging modalities such as CT and MRI provide resolution adequate to diagnose cardiovascular diseases but cannot depict detailed structural features in the heart across length scales. Hierarchical phase-contrast tomography (HiP-CT) uses fourth-generation synchrotron sources with improved x-ray brilliance and high energies to provide micron-resolution imaging of intact adult organs with unprecedented detail. Purpose To evaluate the capability of HiP-CT to depict the macro- to microanatomy of structurally normal and abnormal adult human hearts ex vivo. Materials and Methods Between February 2021 and September 2023, two adult human donor hearts were obtained, fixed in formalin, and prepared using a mixture of crushed agar in a 70% ethanol solution. One heart was from a 63-year-old White male without known cardiac disease, and the other was from an 87-year-old White female with a history of multiple known cardiovascular pathologies including ischemic heart disease, hypertension, and atrial fibrillation. Nondestructive ex vivo imaging of these hearts without exogenous contrast agent was performed using HiP-CT at the European Synchrotron Radiation Facility. Results HiP-CT demonstrated the capacity for high-spatial-resolution, multiscale cardiac imaging ex vivo, revealing histologic-level detail of the myocardium, valves, coronary arteries, and cardiac conduction system across length scales. Virtual sectioning of the cardiac conduction system provided information on fatty infiltration, vascular supply, and pathways between the cardiac nodes and adjacent structures. HiP-CT achieved resolutions ranging from gross (isotropic voxels of approximately 20 µm) to microscopic (approximately 6.4-µm voxel size) to cellular (approximately 2.3-µm voxel size) in scale. The potential for quantitative assessment of features in health and disease was demonstrated. Conclusion HiP-CT provided high-spatial-resolution, three-dimensional images of structurally normal and diseased ex vivo adult human hearts. Whole-heart image volumes were obtained with isotropic voxels of approximately 20 µm, and local regions of interest were obtained with resolution down to 2.3-6.4 µm without the need for sectioning, destructive techniques, or exogenous contrast agents. Published under a CC BY 4.0 license Supplemental material is available for this article. See also the editorial by Bluemke and Pourmorteza in this issue.


Assuntos
Coração , Tomografia Computadorizada por Raios X , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Coração/diagnóstico por imagem , Idoso de 80 Anos ou mais , Cardiopatias/diagnóstico por imagem , Síncrotrons
3.
Biomech Model Mechanobiol ; 23(4): 1149-1160, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38587717

RESUMO

Endovascular treatment has become the standard therapy for cerebral aneurysms, while the effective treatment for middle cerebral artery (MCA) bifurcation aneurysms remains a challenge. Current flow-diverting techniques with endovascular coils cover the aneurysm orifice as well as adjacent vessel branches, which may lead to branch occlusion. Novel endovascular flow disruptors, such as the Contour device (Cerus Endovascular), are of great potential to eliminate the risk of branch occlusion. However, there is a lack of valid comparison between novel flow disruptors and conventional (intraluminal) flow-diverters. In this study, two in silico MCA bifurcation aneurysm models were treated by specific Contour devices and flow-diverters using fast-deployment algorithms. Computational fluid dynamic simulations were used to examine the performance and efficiency of deployed devices. Hemodynamic parameters, including aneurysm inflow and wall shear stress, were compared among each Contour device, conventional flow-diverter, and untreated condition. Our results show that the placement of devices can effectively reduce the risk of aneurysm rupture, while the deployment of a Contour device causes more flow reduction than using flow-diverters (e.g. Silk Vista Baby). Besides, the Contour device presents the flow diversion capability of targeting the aneurysm neck without occluding the daughter vessel. In summary, the in silico aneurysm models presented in this study can serve as a powerful pre-planning tool for testing new treatment techniques, optimising device deployment, and predicting the performance in patient-specific aneurysm cases. Contour device is proved to be an effective treatment of MCA bifurcation aneurysms with less daughter vessel occlusion.


Assuntos
Simulação por Computador , Aneurisma Intracraniano , Artéria Cerebral Média , Aneurisma Intracraniano/fisiopatologia , Aneurisma Intracraniano/terapia , Humanos , Artéria Cerebral Média/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Estresse Mecânico
6.
Disabil Health J ; 17(3): 101585, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38280827

RESUMO

BACKGROUND: Motor Neurone Disease (MND), is a debilitating neurodegenerative condition, which significantly impacts the quality of life of those affected. Neck weakness is one challenge faced by those living with MND and as such may require a neck collar to assist. However, the user experience and requirements related to these neck collars have not been comprehensively explored. Understanding these priorities is crucial for enhancing the well-being of MND patients. OBJECTIVE: To understand the priorities of people living with Motor Neurone Disease (MND) including user experience, requirements and the importance of neck collars used to aid neck weakness. METHODS: An online survey was used to investigate the perspectives and experiences of off the shelf neck collars used by people living with MND. The MND Association was selected as a strategic partner by their affiliations and access to large data base of MND patients. RESULTS: Survey highlighted a disparity between the actual duration MND patients wear their current neck collars and their desired duration, emphasising the need to integrate collars into daily activities. Key areas for improvement with existing neck collars centred on comfort and reduced restriction, with respondents expressing a preference for collars that offer support without impeding movement. Additionally, addressing pressure on the anterior neck region during collar use emerged as a critical requirement. CONCLUSION: Current collars do not cause any clinical complications; however, they do fall short of meeting the expected needs of people living with MND, including discomfort, restricted movement, and pressure to the anterior region of the neck. This study highlights need to improve current collar designs to provide better quality of life for MND patients.


Assuntos
Doença dos Neurônios Motores , Qualidade de Vida , Humanos , Doença dos Neurônios Motores/psicologia , Masculino , Feminino , Pessoa de Meia-Idade , Inquéritos e Questionários , Idoso , Adulto , Pescoço , Pessoas com Deficiência/psicologia , Atividades Cotidianas , Preferência do Paciente/psicologia , Preferência do Paciente/estatística & dados numéricos , Debilidade Muscular , Tecnologia Assistiva/estatística & dados numéricos , Aparelhos Ortopédicos/estatística & dados numéricos
7.
J Cardiovasc Comput Tomogr ; 18(2): 142-153, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38143234

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) analysis is currently performed by experts and is a laborious process. Fully automated edge-detection methods have been developed to expedite CCTA segmentation however their use is limited as there are concerns about their accuracy. This study aims to compare the performance of an automated CCTA analysis software and the experts using near-infrared spectroscopy-intravascular ultrasound imaging (NIRS-IVUS) as a reference standard. METHODS: Fifty-one participants (150 vessels) with chronic coronary syndrome who underwent CCTA and 3-vessel NIRS-IVUS were included. CCTA analysis was performed by an expert and an automated edge detection method and their estimations were compared to NIRS-IVUS at a segment-, lesion-, and frame-level. RESULTS: Segment-level analysis demonstrated a similar performance of the two CCTA analyses (conventional and automatic) with large biases and limits of agreement compared to NIRS-IVUS estimations for the total atheroma (ICC: 0.55 vs 0.25, mean difference:192 (-102-487) vs 243 (-132-617) and percent atheroma volume (ICC: 0.30 vs 0.12, mean difference: 12.8 (-5.91-31.6) vs 20.0 (0.79-39.2). Lesion-level analysis showed that the experts were able to detect more accurately lesions than the automated method (68.2 â€‹% and 60.7 â€‹%) however both analyses had poor reliability in assessing the minimal lumen area (ICC 0.44 vs 0.36) and the maximum plaque burden (ICC 0.33 vs 0.33) when NIRS-IVUS was used as the reference standard. CONCLUSIONS: Conventional and automated CCTA analyses had similar performance in assessing coronary artery pathology using NIRS-IVUS as a reference standard. Therefore, automated segmentation can be used to expedite CCTA analysis and enhance its applications in clinical practice.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Reprodutibilidade dos Testes , Ultrassonografia de Intervenção/métodos , Valor Preditivo dos Testes , Algoritmos , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA