Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Braz J Anesthesiol ; 72(2): 189-193, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34329661

RESUMO

BACKGROUND: Percutaneous dilation tracheostomy is an aerosol-generating procedure carrying a documented infectious risk during respiratory virus pandemics. For this reason, during the COVID-19 outbreak, surgical tracheostomy was preferred to the percutaneous one, despite the technique related complications increased risk. METHODS: We describe a new sequence for percutaneous dilation tracheostomy procedure that could be considered safe both for patients and healthcare personnel. A fiberscope was connected to a video unit to allow bronchoscopy. Guidewire positioning was performed as usual. While the established standard procedure continues with the creation of the stoma without any change in mechanical ventilation, we retracted the bronchoscope until immediately after the access valve in the mount tube, allowing normal ventilation. After 3 minutes of ventilation with 100% oxygen, mechanical ventilation was stopped without disconnecting the circuit. During apnea, the stoma was created by dilating the trachea and the tracheostomy cannula was inserted. Ventilation was then resumed. We evaluated the safeness of the procedure by recording any severe desaturation and by performing serological tests to all personnel. RESULTS: Thirty-six patients (38%) of 96 underwent tracheostomy; 22 (23%) percutaneous dilation tracheostomies with the new approach were performed without any desaturation. All personnel (150 operators) were evaluated for serological testing: 9 (6%) had positive serology but none of them had participated in tracheostomy procedures. CONCLUSION: This newly described percutaneous dilation tracheostomy technique was not related to severe desaturation events and we did not observe any positive serological test in health workers who performed the tracheostomies.


Assuntos
COVID-19 , Traqueostomia , Apneia/etiologia , Humanos , Pandemias , Respiração Artificial/métodos , Traqueostomia/efeitos adversos , Traqueostomia/métodos
2.
J Thorac Dis ; 11(8): 3257-3269, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31559028

RESUMO

BACKGROUND: One-lung ventilation (OLV) in thoracic anesthesia is required to provide good surgical exposure. OLV is commonly achieved through a double lumen tube (DLT) or a bronchial blocker (BB). Malposition is a relevant issue related to these devices use. No prospective studies with adequately large sample size have been performed to evaluate the malposition rate of DLTs and BBs. METHODS: A total of 2,127 patients requiring OLV during thoracic surgery were enrolled. The aim of this multicenter prospective observational study performed across 26 academic and community hospitals is to evaluate intraoperative malposition rate of DLTs and BBs. We also aim to assess: which device is the most used to achieve OLV, the frequency of bronchoscope (BRO) use, the incidence rate of desaturation during OLV and the role of other factors that can correlate to this event, and incidence of difficult airway. RESULTS: Malposition rate for DLTs was 14%, for BBs 33%. DLTs were used in 95% of patients and BBs in 5%. Mean positioning time was shorter for DLT than BB (156±230 vs. 321±290 s). BRO was used in 54% of patients to check the correct positioning of the DLT. Desaturation occurred in 20% of all cases during OLV achieved through a DLT. Predicting factors of desaturation were dislocation (OR 2.03) and big size of DLT (OR 1.15). BRO use (OR 0.69) and left surgical side (OR 0.41) proved to be protective factors. Difficult airway prevalence was 16%; 10.8% predicted and 5.2% unpredicted. CONCLUSIONS: DLT has a low malpositioning rate and is the preferred device to achieve OLV. BRO use recorded was unexpectedly low. The possibility of encountering a difficult airway is frequent, with an overall prevalence of 16%. Risk factors of desaturation are malposition and increased size of DLT. Left procedures and BRO use could lead to fewer episodes of desaturation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA