Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-37552784

RESUMO

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco
2.
Eur Heart J ; 43(29): 2770-2780, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35695691

RESUMO

AIM: Fatality of infective endocarditis (IE) is high worldwide, and its diagnosis remains a challenge. The objective of the present study was to compare the clinical characteristics and outcomes of patients with culture-positive (CPIE) vs. culture-negative IE (CNIE). METHODS AND RESULTS: This was an ancillary analysis of the ESC-EORP EURO-ENDO registry. Overall, 3113 patients who were diagnosed with IE during the study period were included in the present study. Of these, 2590 (83.2%) had CPIE, whereas 523 (16.8%) had CNIE. As many as 1488 (48.1%) patients underwent cardiac surgery during the index hospitalization, 1259 (48.8%) with CPIE and 229 (44.5%) with CNIE. The CNIE was a predictor of 1-year mortality [hazard ratio (HR) 1.28, 95% confidence interval (CI) 1.04-1.56], whereas surgery was significantly associated with survival (HR 0.49, 95% CI 0.41-0.58). The 1-year mortality was significantly higher in CNIE than CPIE patients in the medical subgroup, but it was not significantly different in CNIE vs. CPIE patients who underwent surgery. CONCLUSION: The present analysis of the EURO-ENDO registry confirms a higher long-term mortality in patients with CNIE compared with patients with CPIE. This difference was present in patients receiving medical therapy alone and not in those who underwent surgery, with surgery being associated with reduced mortality. Additional efforts are required both to improve the aetiological diagnosis of IE and identify CNIE cases early before progressive disease potentially contraindicates surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Endocardite Bacteriana , Endocardite , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Endocardite/diagnóstico , Endocardite/epidemiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/terapia , Humanos , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos
5.
Eur Heart J Cardiovasc Imaging ; 21(1): 24-33, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31539031

RESUMO

AIMS: To define characteristic PET/CTA patterns of FDG uptake and anatomic changes following prosthetic heart valves (PVs) implantation over time, to help not to misdiagnose post-operative inflammation and avoid false-positive cases. METHODS AND RESULTS: Prospective evaluation of 37 post-operative patients without suspected infection that underwent serial cardiac PET/CTA examinations at 1, 6, and 12 months after surgery, in which metabolic features (FDG uptake distribution pattern and intensity) and anatomic changes were evaluated. Standardized uptake values (SUVs) were obtained and a new measure, the valve uptake index (VUI), (SUVmax-SUVmean)/SUVmax, was tested to homogenize SUV results.In total, 111 PET/CTA scans were performed in 37 patients (19 aortic and 18 mitral valves). FDG uptake was visually detectable in 79.3% of patients and showed a diffuse, homogeneous distribution pattern in 93%. Quantitative analysis yielded a mean maximum standardized uptake value (SUVmax) of 4.46 ± 1.50 and VUI of 0.35 ± 0.10. There were no significant differences in FDG distribution or uptake values between 1, 6, or 12 months. No abnormal anatomic changes or endocarditis lesions were detected in any patient during follow-up. CONCLUSIONS: FDG uptake, often seen in recently implanted PVs, shows a characteristic pattern of post-operative inflammation and, in the absence of associated anatomic lesions, could be considered a normal finding. These features remain stable for at least 1 year after surgery, so questioning the recommended 3-month safety period. A new measure, the VUI, can be useful for evaluating the FDG distribution pattern.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/cirurgia , Humanos , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Estudos Retrospectivos
6.
Circulation ; 140(21): 1753-1765, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31738598

RESUMO

Infective endocarditis (IE) is a complex disease with cardiac involvement and multiorgan complications. Its prognosis depends on prompt diagnosis that leads to an aggressive therapeutic management combining antibiotic therapy and early cardiac surgery when indicated. However, IE diagnosis always poses a challenge, and echocardiography remains diagnostically imperfect in cases of prosthetic valve IE or cardiac implantable electronic device infection. In recent years, other imaging modalities (computed tomography, magnetic resonance imaging, nuclear imaging) have experienced significant technical improvements, and their application to the detection of cardiac and extracardiac IE-related lesions seems to be a strategic way forward in the management of patients with suspected IE. However, the scientific evidence in the literature remains limited; current guidelines address the use of the multimodality imaging in the field of IE with caution; the incremental value of each technique and their combinations is debated; and their use varies across countries. Despite these limitations, healthcare providers and surgeons should be aware of the possibilities offered by the multimodal imaging approach when appropriate. Here, we emphasize the value of a multidisciplinary heart valve team, the endocarditis team, underlining the importance of cardiac and extracardiac imaging experts in playing a key role in informing the diagnosis and management of patients with IE. Illustrative cases, critical appraisal of contemporary data, and conceptual and practical suggestions for clinicians that may help to improve the prognosis of patients with IE are provided in this review article.


Assuntos
Endocardite/diagnóstico por imagem , Imagem Multimodal , Equipe de Assistência ao Paciente , Comportamento Cooperativo , Endocardite/terapia , Humanos , Comunicação Interdisciplinar , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes
7.
Eur Heart J ; 40(39): 3222-3232, 2019 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-31504413

RESUMO

AIMS: The EURO-ENDO registry aimed to study the management and outcomes of patients with infective endocarditis (IE). METHODS AND RESULTS: Prospective cohort of 3116 adult patients (2470 from Europe, 646 from non-ESC countries), admitted to 156 hospitals in 40 countries between January 2016 and March 2018 with a diagnosis of IE based on ESC 2015 diagnostic criteria. Clinical, biological, microbiological, and imaging [echocardiography, computed tomography (CT) scan, 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT)] data were collected. Infective endocarditis was native (NVE) in 1764 (56.6%) patients, prosthetic (PVIE) in 939 (30.1%), and device-related (CDRIE) in 308 (9.9%). Infective endocarditis was community-acquired in 2046 (65.66%) patients. Microorganisms involved were staphylococci in 1085 (44.1%) patients, oral streptococci in 304 (12.3%), enterococci in 390 (15.8%), and Streptococcus gallolyticus in 162 (6.6%). 18F-fluorodeoxyglucose positron emission tomography/computed tomography was performed in 518 (16.6%) patients and presented with cardiac uptake (major criterion) in 222 (42.9%) patients, with a better sensitivity in PVIE (66.8%) than in NVE (28.0%) and CDRIE (16.3%). Embolic events occurred in 20.6% of patients, and were significantly associated with tricuspid or pulmonary IE, presence of a vegetation and Staphylococcus aureus IE. According to ESC guidelines, cardiac surgery was indicated in 2160 (69.3%) patients, but finally performed in only 1596 (73.9%) of them. In-hospital death occurred in 532 (17.1%) patients and was more frequent in PVIE. Independent predictors of mortality were Charlson index, creatinine > 2 mg/dL, congestive heart failure, vegetation length > 10 mm, cerebral complications, abscess, and failure to undertake surgery when indicated. CONCLUSION: Infective endocarditis is still a life-threatening disease with frequent lethal outcome despite profound changes in its clinical, microbiological, imaging, and therapeutic profiles.


Assuntos
Embolia/microbiologia , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Adulto , África do Norte/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Ásia/epidemiologia , Infecções Comunitárias Adquiridas/diagnóstico por imagem , Infecções Comunitárias Adquiridas/epidemiologia , Ecocardiografia/estatística & dados numéricos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/microbiologia , Enterococcus , Europa (Continente)/epidemiologia , Feminino , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Compostos Radiofarmacêuticos , Sistema de Registros , América do Sul/epidemiologia , Infecções Estafilocócicas/complicações , Infecções Estreptocócicas/complicações , Resultado do Tratamento
8.
Eur Heart J Qual Care Clin Outcomes ; 5(3): 202-207, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30957862

RESUMO

AIMS: The European Society of Cardiology (ESC) EURObservational Research Programme (EORP) European Endocarditis (EURO-ENDO) registry aims to study the care and outcomes of patients diagnosed with infective endocarditis (IE) and compare findings with recommendations from the 2015 ESC Clinical Practice Guidelines for the management of IE and data from the 2001 Euro Heart Survey. METHODS AND RESULTS: Patients (n = 3116) aged over 18 years with a diagnosis of IE based on the ESC 2015 IE diagnostic criteria were prospectively identified between 1 January 2016 and 31 March 2018. Individual patient data were collected across 156 centres and 40 countries. The primary endpoint is all-cause mortality in hospital and at 1 year. Secondary endpoints are 1-year morbidity (all-cause hospitalization, any cardiac surgery, and IE relapse), the clinical, epidemiological, microbiological, and therapeutic characteristics of patients, the number and timing of non-invasive imaging techniques, and adherence to recommendations as stated in the 2015 ESC Clinical Practice Guidelines for the management of IE. CONCLUSION: EURO-ENDO is an international registry of care and outcomes of patients hospitalized with IE which will provide insights into the contemporary profile and management of patients with this challenging disease.


Assuntos
Endocardite , Sistema de Registros , Endocardite/diagnóstico , Endocardite/terapia , Europa (Continente) , Humanos , Guias de Prática Clínica como Assunto
10.
Eur J Health Econ ; 19(7): 945-956, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29170843

RESUMO

OBJECTIVES: The economic crisis in Europe might have limited access to some innovative technologies implying an increase of waiting time. The purpose of the study is to evaluate the impact of waiting time on the costs and benefits of transcatheter aortic valve replacement (TAVR) for the treatment of severe aortic stenosis. METHODS: This is a cost-utility analysis from the perspective of the Spanish National Health Service. Results of two prospective hospital registries (158 and 273 consecutive patients) were incorporated into a probabilistic Markov model to compare quality adjusted life years (QALYs) and costs for TAVR after waiting for 3-12 months, relative to immediate TAVR. We simulated a cohort of 1000 patients, male, and 80 years old; other patient profiles were assessed in sensitivity analyses. RESULTS: As waiting time increased, costs decreased at the expense of lower survival and loss of QALYs, leading to incremental cost-effectiveness ratios for eliminating waiting lists of about 12,500 € per QALY. In subgroup analyses prioritization of patients for whom higher benefit was expected led to a smaller loss of QALYs. Concerning budget impact, long waiting lists reduced spending considerably and permanently. CONCLUSIONS: A shorter waiting time is likely to be cost-effective (considering commonly accepted willingness-to-pay thresholds in Europe) relative to 3 months or longer waiting periods. If waiting lists are nevertheless seen as unavoidable due to severe but temporary budgetary restrictions, prioritizing patients for whom higher benefit is expected appears to be a way of postponing spending without utterly sacrificing patients' survival and quality of life.


Assuntos
Estenose da Valva Aórtica/terapia , Substituição da Valva Aórtica Transcateter/economia , Listas de Espera , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Europa (Continente) , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
11.
Int J Cardiol ; 248: 396-402, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28807509

RESUMO

OBJECTIVES: Infective endocarditis (IE) and cardiac device infection (CDI) are a major complication in the growing number of patients with congenital heart disease (CHD) reaching adulthood. We aimed to evaluate the added value of 18F-FDG-PET/CT angiography (PET/CTA) in the diagnosis of IE-CDI in adults with CHD and intravascular or intracardiac prosthetic material, in whom echocardiography (ECHO) and modified Duke Criteria (DC) have limitations because of the patients' complex anatomy. METHODS: A prospective study was conducted in a referral center with multidisciplinary IE and CHD Units. PET/CTA and ECHO findings were compared in consecutive adult (≥18years) patients with CHD who have prosthetic material and suspected IE-CDI. The initial diagnosis using the DC and the diagnosis with the additional PET/CTA data (DC+PET/CTA) were compared with the final diagnostic consensus established by an expert team at three months. RESULTS: Between November-2012 and April-2017, 25 patients (15 men; median age 40years) were included. Cases were initially classified as definite in 8 (32%), possible in 14 (56%) and rejected in 3 (12%). DC+PET/CTA allowed reclassification of 12/14 (86%) cases initially identified as possible IE. The sensitivity, specificity, PPV, NPV, and accuracy of DC at IE suspicion were 39.1%/83.3%/90.4%/25.5%/61.2%, respectively. The diagnostic performance increased significantly with addition of PET/CTA data: 87%/83.3%/95.4%/61.5%/85.1%, respectively. PET/CTA also provided an alternative diagnosis in 3 patients with rejected IE, and detected pulmonary embolisms in 3 patients. CONCLUSIONS: PET/CTA was a useful diagnostic tool in the complex group of adult patients with CHD who have cardiac or intravascular prosthetic material and suspected IE or CDI, providing added diagnostic value to the modified DC (increased sensitivity) and improving case classification.


Assuntos
Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/etiologia , Contaminação de Equipamentos , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/microbiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adulto , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Int J Cardiol ; 223: 1019-1024, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27592044

RESUMO

BACKGROUND: We aimed to analyze causes, management, and outcomes of the unexpected need to abort sternotomy in aortic stenosis (AS) patients accepted for surgical aortic valve replacement (SAVR) in the transcatheter aortic valve implantation (TAVI) era. METHODS: Cases of aborted sternotomy (AbS) were gathered from 5 centers between 2009 and 2014. A systematic review of all published cases in the same period was performed. RESULTS: A total of 31 patients (71% males, 74±8years, LogEuroSCORE 11.9±7.4%) suffered an AbS (0.19% of all sternotomies). Main reasons for Abs included previously unknown porcelain aorta (PAo) in 83.9%, mediastinal fibrosis due to radiotherapy in 12.9%, and chronic mediastinitis in 3.2%. Median time between AbS and next intervention was 2.3months (IQR: 0.7-5.8) with no mortality within this period. Only a case was managed with open surgery. In 30 patients (96.8%) TAVI was performed with a rate of success of 86.7%. Three patients (9.7%) presented in-hospital death and 17 (54.8%) had in-hospital complications including heart failure (9.6%), major bleeding (6.9%), and acute kidney injury (9.6%). Older patients (76±8 vs. 70±8years, p=0.045), previous cardiac surgery (60% vs. 15.4%, p=0.029), and shorter time from AbS to next intervention (5.1±5 vs. 1±0.7months, p=0.001) were related to higher six-month mortality (22.6%). CONCLUSIONS: The main reason for AbS was PAo. This entity was associated to a higher rate of complications and mortality, especially in older patients and with prior cardiac surgery. A preventive strategy in these subgroups might be based on imaging evaluation. TAVI was the most extended therapy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Reoperação , Esternotomia , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/epidemiologia , Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Doenças do Mediastino/epidemiologia , Mortalidade , Avaliação de Processos e Resultados em Cuidados de Saúde , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Espanha , Esternotomia/métodos , Esternotomia/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
15.
Circ J ; 80(2): 354-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26725763

RESUMO

BACKGROUND: The effects of dual antiplatelet therapy (DAPT) and triple therapy (TT: DAPT plus oral anticoagulation) in patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) regarding to CHA2DS2-VASc score remain undefined.We compare the effect of TT vs. DAPT in this setting regarding the CHA2DS2-VASc score. METHODS AND RESULTS: In a prospective multicenter registry, 585 patients (75.2% male, 73.2 ± 8.2 years) with AF undergoing PCI were followed up during 1 year. Of them, 157 (26.8%) had a CHA2DS2-VASc=1, and 428 (73.2%) had a CHA2DS2-VASc ≥2. TT was prescribed in 51.6% with CHA2DS2-VASc=1 and in 55.5% with CHA2DS2-VASc ≥ 2. Patients with CHA2DS2-VASc=1 receiving TT had a similar thromboembolism rate to those on DAPT (1.2% vs. 1.3%, P=0.73), but more total (19.5% vs. 6.9%, P=0.01) and a tendency to more major (4.9% vs. 0%, P=0.06) bleeding. However, patients with CHA2DS2-VASc ≥ 2 receiving TT had a lower thromboembolism rate (1.7% vs. 5.3%, P=0.03) and a trend towards more bleeds (21.8% vs. 15.6%, P=0.06), with an excess of major bleeding (8.4% vs. 3.1%, P=0.01). Rates of major adverse cardiac events (MACE) in both CHA2DS2-VASc subgroups were similar, irrespective of treatment. In a Cox multivariate analysis, TT was associated to major bleeding, but not with MACE. CONCLUSIONS: In patients with AF and CHA2DS2-VASc=1 undergoing PCI, the use of TT involves a high risk of bleeding without a significant benefit in preventing thromboembolism.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Sistema de Registros , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Medição de Risco , Tromboembolia/etiologia
16.
PLoS One ; 11(1): e0147245, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26808678

RESUMO

BACKGROUND AND PURPOSE: Selecting an ideal antithrombotic therapy for elderly patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) can be challenging since they have a higher thromboembolic and bleeding risk than younger patients. The current study aimed to assess the efficacy and safety of triple therapy (TT: oral anticoagulation plus dual antiplatelet therapy: aspirin plus clopidogrel) in patients ≥75 years of age with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI). METHODS: A prospective multicenter study was conducted from 2003 to 2012 at 6 Spanish teaching hospitals. A cohort study of consecutive patients with AF undergoing PCI and treated with TT or dual antiplatelet therapy (DAPT) was analyzed. All outcomes were evaluated at 1-year of follow-up. RESULTS: Five hundred and eighty-five patients, 289 (49%) of whom were ≥75 years of age (79.6±3.4 years; 33% women) were identified. TT was prescribed in 55.9% of patients at discharge who had a higher thromboembolic risk (CHA2DS2VASc score: 4.23±1.51 vs 3.76±1.40, p = 0.007 and a higher bleeding risk (HAS-BLED ≥3: 88.6% vs 79.2%, p = 0.02) than those on DAPT. Therefore, patients on TT had a lower rate of thromboembolism than those on DAPT (0.6% vs 6.9%, p = 0.004; HR 0.08, 95% CI: 0.01-0.70, p = 0.004). Major bleeding events occurred more frequently in patients on TT than in those on DAPT (11.7% vs 2.4%, p = 0.002; HR 5.2, 95% CI: 1.53-17.57, p = 0.008). The overall mortality rate was similar in both treatment groups (11.9% vs 13.9%, p = 0.38); however, after adjustment for confounding variables, TT was associated with a reduced mortality rate (HR 0.33, 95% CI: 0.12-0.86, p = 0.02). CONCLUSIONS: In elderly patients with AF undergoing PCI, the use of TT compared to DAPT was associated with reduced thromboembolism and mortality rates, although a higher rate of major bleeding.


Assuntos
Fibrilação Atrial/terapia , Intervenção Coronária Percutânea , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Clopidogrel , Feminino , Humanos , Masculino , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Fatores de Risco , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico
17.
J Matern Fetal Neonatal Med ; 29(14): 2306-11, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26371393

RESUMO

OBJECTIVES: The objective of this study is to evaluate obstetric outcomes in women with heart disease and determine whether current multidisciplinary management approaches adversely affect the mother, the neonate, or both. Also to compare the accuracy of several risk scores (RS) including the modified World Health Organization classification (mWHO) and CARPREG to predict obstetric and neonatal complications and to study the addition value of Uteroplacental-Doppler flow (UDF) parameters to predict obstetric complications. METHODS: A prospective cohort study examined outcomes in women with heart disease (HD), the majority of whom had corrective surgery and delivered between January 2007 and March 2012. RESULTS: One hundred and seventy-four patients with 179 pregnancies were included in the study. Obstetric complications, including premature labor, arose in 87 patients (48.6%). Neonatal complications were observed in 11 cases (7%). On multivariate analysis, maternal heart disease was predictive of adverse perinatal events (46 cases, 25.7%) and mode of delivery (Thierry's spatula) of third- or fourth-degree perineal tears (six cases, 3.2%). mWHO classification predicted obstetric complications (p = 0.0001) better than the CARPREG study. Impaired UDF (uterine artery pulsatility index-20 weeks and umbilical artery pulsatility index-32 weeks in HD versus healthy women: 20w 1.12 versus 1.34, p = 0.005; 32w 0.87 versus 1.09, p = 0.008) was associated with adverse obstetric and offspring outcome in the group of HD pregnant women. CONCLUSIONS: Nearly 50% of pregnancies were associated with an adverse obstetric outcome, particularly IUGR. mWHO was better at predicting obstetric and neonatal complications that CARPREG in all categories. Furthermore, compromised UDF combined with mWHO improved the prediction of obstetric and offspring complications in this population.


Assuntos
Cardiopatias/epidemiologia , Complicações Cardiovasculares na Gravidez/epidemiologia , Adulto , Cesárea/estatística & dados numéricos , Bases de Dados Factuais , Parto Obstétrico/efeitos adversos , Enterocolite/epidemiologia , Feminino , Retardo do Crescimento Fetal/epidemiologia , Cardiopatias/complicações , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Análise Multivariada , Períneo/lesões , Hemorragia Pós-Parto/epidemiologia , Gravidez , Nascimento Prematuro/epidemiologia , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Síndrome do Desconforto Respiratório do Recém-Nascido/epidemiologia , Espanha/epidemiologia , Artérias Umbilicais/fisiopatologia , Artéria Uterina/fisiopatologia , Inércia Uterina/epidemiologia
18.
Clin Res Cardiol ; 105(6): 508-17, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26646556

RESUMO

BACKGROUND AND PURPOSE: The risk of neurological damage following transcatheter aortic valve implantation (TAVI) vs. surgical aortic valve replacement (SAVR) in severe aortic stenosis patients deemed to be at intermediate surgical risk is unknown. In this target population, the degree of neurological damage was compared using brain diffusion-weighted magnetic resonance imaging (DW-MRI) and cognitive testing. METHODS: Forty-six consecutive patients undergoing TAVI (78.0 ± 8.3 years; STS score 4.4 ± 1.7) and 37 patients undergoing SAVR (78.9 ± 6.2 years, STS score 4.7 ± 1.7) were compared. DW-MRI was performed in 67 patients (40 in TAVI vs. 27 in SAVR group) within the first 15 days post-procedure. A cognitive assessment was performed at baseline and at 3 months follow-up. The occurrence of potential cognitive impairment post-intervention was determined using the reliable change index (RCI). RESULTS: Baseline characteristics were comparable in TAVI and SAVR groups except for the presence of severe calcified aorta, which occurred more frequently in the TAVI group [17 (37 %) vs. 0 (0 %), p < 0.001]. Three patients presented a clinical stroke: 1 (2.2 %) in TAVI group vs. 2 (5.4 %) in SAVR group, (p = 0.58). No differences were observed in the rate of acute ischemic cerebral lesions detected by DWI in patients undergoing TAVI vs. SAVR [18 (45 %) in TAVI vs. 11 (40.7 %) in SAVR, adjusted OR 0.95; 95 % CI 0.25-3.65; p = 0.94]. TAVI was associated with a lower number of DWI lesions (adjusted OR 0.54; 95 % IC 0.37-0.79; p = 0.02). An older age was a predictor of the occurrence of acute lesions (OR 1.13; 95 % CI 1.03-1.23; p = 0.01), and the use of vitamin-K antagonist therapy had a protective effect (OR 0.25; 95 % CI 0.07-0.92; p = 0.037) regardless the type of intervention. Overall no significant changes were observed in global cognitive scores post-intervention (p = 0.23). The RCI showed mild cognitive decline in nine patients undergoing TAVI (26.4 %) and in six patients in the SAVR group (30.0 %) (p = 0.96). There was no association between the number and total volume of lesions and the occurrence of cognitive decline (CC Spearman 0.031, p = 0.85 and -0.011, p = 0.97, respectively). CONCLUSIONS: TAVI and SAVR were associated with a similar rate of acute silent ischemic cerebral lesions in intermediate risk patients. Although acute lesions occurred very frequently in both strategies, their cognitive impact was not clinically relevant.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Isquemia Encefálica/etiologia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Isquemia Encefálica/psicologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Cognição , Imagem de Difusão por Ressonância Magnética , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Análise Multivariada , Testes Neuropsicológicos , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
19.
Circulation ; 132(12): 1113-26, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26276890

RESUMO

BACKGROUND: The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/computed tomography (CT) and (18)F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit. METHODS AND RESULTS: Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% (P<0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT (P=0.006) or echocardiography (P<0.001). CONCLUSIONS: (18)F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.


Assuntos
Angiografia/métodos , Desfibriladores Implantáveis/microbiologia , Endocardite/diagnóstico , Próteses Valvulares Cardíacas/microbiologia , Marca-Passo Artificial/microbiologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Arritmias Cardíacas/terapia , Ecocardiografia , Endocardite/diagnóstico por imagem , Feminino , Fluordesoxiglucose F18 , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Int J Cardiol ; 197: 16-22, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26113471

RESUMO

AIMS: To assess the effectiveness of different treatment strategies in patients with non-obstructive prosthetic valve thrombosis (NOPVT) during hospitalization and long-term follow-up. METHODS: NOPVT was diagnosed by transesophageal echocardiography. Resolution was defined as the disappearance or reduction of the thrombus under anticoagulation. All cases were first managed with optimization of anticoagulation. At discharge, patients received oral anticoagulation (OAC) alone or OAC and antiplatelet therapy (double treatment). Adverse events were defined as cardiovascular death, recurrence, thromboembolic events or major bleeding. RESULTS: From 1997 to 2012, 47 patients (mean age: 65years; women: 60%) were diagnosed with NOPVT (mitral valve: 97%). Previous poor anticoagulation control was documented in 66% of patients. Twenty-one patients (45%) were treated with unfractionated heparin (UFH), especially those with thrombus size >10mm (19/21). Optimization of OAC was performed in the remaining patients. Treatment failed in 13 (27.6%) patients, mostly in those who received UFH (10/13), requiring surgery (53.8%) or fibrinolysis (30.7%). Forty-two patients survived and, at discharge, 44% of patients received OAC alone and 56% the double treatment. At follow-up (median 23months; range 0.03-116months), 59.5% of patients presented cardiovascular events, however no differences in outcome were observed with double treatment or OAC alone (p=0.385). CONCLUSIONS: NOPVT is a high-risk complication, not only during hospitalization but also during follow-up. Optimization of anticoagulation is efficient in most patients except in thrombi ≥10mm treated with UFH. The double treatment does not prevent adverse events or complications during follow-up.


Assuntos
Próteses Valvulares Cardíacas/efeitos adversos , Trombose/etiologia , Idoso , Anticoagulantes/uso terapêutico , Ecocardiografia Transesofagiana , Feminino , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Recidiva , Tromboembolia/etiologia , Trombose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA