Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Clin Exp Dent ; 15(5): e382-e389, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37214747

RESUMO

Background: Gutta-percha (Gp) is an inert thermoplastic polymer used as a filling to replace the dental pulp space, which has been reformulated to improve its three-dimensional sealing properties. Therefore, this study aimed to analyze the physical, chemical and thermal properties of two types of gutta-percha filling. As well as measuring the temperature distribution along the cone at the time of cutting through an in-situ test. Material and Methods: Two commercially available brands of gutta-percha point were investigated: Conform Fit TM Gutta-Percha for ProTaper Gold® (PTG) (Dentsply Sirona), and Hygenic Gutta-Percha (Coltene whaledent). Differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were selected for the thermal characterization of materials, and Fourier Transform Infrared Spectroscopy (FT-IR) for the chemical analysis of Gp cones. Regarding temperature distribution, it was evaluated using a thermographic camera (FLIR ONE® PRO by MicroUSB P/N 435-0011-01) at 0 to 20 s after the cutting process (n=11/group). Results: Both materials have three fusion endotherms associated with the three crystalline phases of Gp, with similar temperatures but enthalpies that differ by 60%, the fusion enthalpy being higher for Conform Fit. In the chemical characterization, elements such as Zn, C, O, Ba, S and Si were found in both materials but in different proportions. Regarding the content of fillers, the Conform Fit presented around 30% of Gp polymer and 25% for the Hygenic. The morphological characterization shows a microtexturized coating in the form of bars on a micrometric scale for the Conform Fit, which could favor a better three-dimensional seal. In addition to that, in heat transfer studies they showed greater temperature control. Conclusions: The characterization of the materials allowed us to see the variation in terms of their composition and configuration to the Gp cones of two commercial brands. These variations directly modify the thermal behavior of the material. Key words:Gutta-percha, Conform Fit, Infrared thermography, Differential Scanning Calorimetry, Infrared Spectroscopy.

2.
Adv Clin Exp Med ; 29(5): 597-602, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32427427

RESUMO

BACKGROUND: Two polymorphisms in the macrophage migration inhibitory factor (MIF) gene have been associated with inflammatory diseases (-794 CATT5-8 and -173G>C); however, so far there are no reports of studies related to oral health. OBJECTIVES: To genotype the -794 CATT5-8 and -173G>C MIF polymorphisms in Mexican patients with apical periodontitis as a genetic risk of exacerbation. MATERIAL AND METHODS: The study involved 120 patients with apical periodontitis: 60 with a diagnosis of acute apical periodontitis (Group A) and 60 without previous episodes of exacerbation (Group B). Allelic discrimination was performed from peripheral blood DNA; the repeat polymorphism -794 CATT5-8 was genotyped with sequencing, while the -173G>C polymorphism was determined using real-time polymerase chain reaction (RT-PCR) using TaqMan probes. The associations between MIF polymorphisms, haplotypes and the risk of exacerbated apical periodontitis were assessed. RESULTS: The allele CATT7 was associated with the risk of a stage of acute inflammation (OR = 4.13; 95% CI = 1.82-9.63; p =< 0.001). Regarding the -173G >C polymorphism, a process of inflammation exacerbation was only associated with the CC genotype (OR = 4.1; 95% CI = 1.02-20.84; p = 0.045). The analysis of the haplotype showed that the combination CATT7/C increases the risk of exacerbation of apical periodontitis (OR = 3.57; 95% CI = 1.038-13.300; p = 0.021). CONCLUSIONS: The polymorphisms -794 CATT5-8 and -173G>C MIF seem to significantly influence the development of a state of exacerbated inflammation in patients with apical periodontitis.


Assuntos
Predisposição Genética para Doença/genética , Fatores Inibidores da Migração de Macrófagos/genética , Periodontite Periapical/genética , Polimorfismo Genético , Frequência do Gene , Genótipo , Humanos , Fatores Inibidores da Migração de Macrófagos/sangue , Polimorfismo de Nucleotídeo Único
3.
Iran Endod J ; 15(4): 246-252, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-36704115

RESUMO

Introduction: This study compared bacterial percolation and sealer penetration of a novel obturation technique with the ones of warm vertical condensation technique. Methods and Materials: A bacterial percolation test was carried out with 80 single rooted human teeth divided into 5 groups; A (n=20): warm vertical condensation and AH-Plus, B (n=20): CPoint with AH-Plus, C (n= 20): CPoint with EndoSequence BC, +ve Control (n=10): teeth with no canal obturation, -ve Control (n=10): teeth with no access cavity. The samples were inoculated with a multispecies bacterial incoulum. Bacterial percolation was evaluated by turbidity. Confocal laser scanning microscopy (CLSM) was used to observe the presence of gaps and voids. Further 48 extracted human mandibular single-canal premolars were used to determine the sealer penetration. Slices of the samples were observed by CLSM to evaluate tubules penetration of the sealer. Kaplan Meyer survival, ANOVA one way and Tuckey HSD test and a Wilcoxon signed-rank test were utilised. Results: A Kaplan-Meier test showed no significant difference overall (P>0.05) between groups A, B and C. At 43 days, the group B showed a significantly inferior ability to prevent bacterial passage (P<0.05). The group C showed a deeper sealer penetration than group A and B with statistically significant differences (P<0.05) for the total penetration (ANOVA one way and Tukey HSD). A Wilcoxon signed-rank test showed statistically significant differences for the penetration in the middle-and apical third of the 3 groups. Conclusion: Based on this in vitro study, the single polymer-cone obturation technique with a resin based- and bioceramic based-sealer behaved similarly to the warm vertical obturation technique in preventing bacterial passage. The bioceramic sealer showed the deepest penetration but did not fully prevent bacterial leakage.

4.
J Appl Biomater Funct Mater ; 17(3): 2280800019851771, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31373255

RESUMO

BACKGROUND: The main microorganism associated with the failure of endodontic treatments is Enterococcus faecalis. Although several endodontic therapeutics have demonstrated antimicrobial activity against E. faecalis, the antimicrobial effectiveness of chitosan (CsNPs) and silver nanoparticles (AgNPs) included into conventional endodontic sealers for endodontic therapies is still unclear. AIM: The objective of this study was to evaluate the antibacterial activity increment (AAI) of endodontic sealers containing CsNPs and AgNPs as well as some chemical components against E. faecalis by direct contact assays. METHODS: CsNPs and AgNPs were synthesized by reduction and ionic gelation methods, respectively. Nanoparticles were characterized by dynamic light scattering and energy dispersive X-ray analysis. The bactericidal activity was tested on monolayers on agar plates and collagen membrane surface assays against E. faecalis. RESULTS: The size of CsNPs was 70.6±14.8 nm and zeta potential was 52.0±5.4 mV; the size of AgNPs was 54.2±8.5 nm, and zeta potential was -48.4±6.9 mV. All materials, single or combined, showed an AAI, especially when CsNPs, chlorhexidine (Chx), and the combination of CsNPs-Chx were added. However, the combination of CsNPs-Chx showed the highest (55%) AAI, followed by Chx (35.5%) and CsNPs (11.1%), respectively. There was a significant statistical difference in all comparisons (p < 0.05). Tubliseal (40%) and AH Plus (32%) sealants showed a higher AAI on E. faecalis in the monolayer test and collagen membrane assay analyzed by scanning electron microscopy. CONCLUSIONS: Tubliseal and AH plus sealers combined with nanoparticles, especially CsNPs-Chx, could be used for conventional endodontic treatments in the control of E. faecalis bacteria.


Assuntos
Antibacterianos , Quitosana , Enterococcus faecalis/crescimento & desenvolvimento , Nanopartículas Metálicas/química , Materiais Restauradores do Canal Radicular , Prata , Antibacterianos/química , Antibacterianos/farmacologia , Quitosana/química , Quitosana/farmacologia , Enterococcus faecalis/ultraestrutura , Humanos , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Varredura , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/farmacologia , Prata/química , Prata/farmacologia
5.
Int J Mol Sci ; 20(11)2019 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-31181755

RESUMO

The increase in bacterial resistance to one or several antibiotics has become a global health problem. Recently, nanomaterials have become a tool against multidrug-resistant bacteria. The metal and metal oxide nanoparticles are one of the most studied nanomaterials against multidrug-resistant bacteria. Several in vitro studies report that metal nanoparticles have antimicrobial properties against a broad spectrum of bacterial species. However, until recently, the bacterial resistance mechanisms to the bactericidal action of the nanoparticles had not been investigated. Some of the recently reported resistance mechanisms include electrostatic repulsion, ion efflux pumps, expression of extracellular matrices, and the adaptation of biofilms and mutations. The objective of this review is to summarize the recent findings regarding the mechanisms used by bacteria to counteract the antimicrobial effects of nanoparticles.


Assuntos
Antibacterianos/farmacologia , Farmacorresistência Bacteriana , Nanopartículas Metálicas/toxicidade , Óxidos/farmacologia , Compostos de Prata/farmacologia , Biofilmes/efeitos dos fármacos , Estresse Oxidativo
6.
Dent Mater J ; 36(3): 266-274, 2017 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-28154313

RESUMO

The objective was to evaluate the effect of adding silver nanoparticles into three commercial adhesive systems (Excite™, Adper Prompt L-Pop™ and AdheSE™). Nanoparticles were prepared by a chemical method then mixed with the commercial adhesive systems. This was later applied to the fluorotic enamel, and then micro-tensile bond strength, contact angle measurements and scanning electron microscopy observations were conducted. The commercial adhesive systems achieved the lowest micro-tensile bond strength (Excite™: 11.0±2.1, Adper Prompt L-Pop™: 14.0±5.4 and AdheSE™: 16.0±3.0 MPa) with the highest adhesive failure mode related with the highest contact angle (46.0±0.6º, 30.0±0.5º and 28.0±0.4º respectively). The bond strength achieved in all the experimental adhesive systems (19.0±5.4, 20.0±4.0 and 19.0±3.5 MPa respectively) was statistically higher (p<0.05) than the control and showed the highest cohesive failures related to the lowest contact angle. Adding silver nanoparticles in order to decrease the contact angle improve the adhesive system wetting and its bond strength.


Assuntos
Nanopartículas , Prata , Adesivos , Resinas Compostas , Colagem Dentária , Esmalte Dentário , Análise do Estresse Dentário , Adesivos Dentinários , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Resistência à Tração
7.
Rev. ADM ; 73(2): 65-71, mar.-abr. 2016. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-789836

RESUMO

Objetivo: evaluar la capacidad de BiodentineTM para resistir la microfiltración cuando es usado como material de retroobturación medianteun sistema de transporte de fluidos computarizado. Metodología: En este estudio se utilizaron 60 raíces de dientes unirradiculares, se instrumentaron y obturaron con el sistema de cono único estandarizadodel sistema ProTaper (Dentsply, Maillefer, Suiza) con ultrasonido,utilizando el sellador de conductos radiculares Silco (Silva-Collyan SLP,México). Se hizo la preparación de la cavidad retrógrada con ultrasonidoutilizando la punta E31D del sistema Retro Kit (NSK Company, Japón),con un diámetro de 2 mm. Se llevó a cabo la retroobturación con cada uno de los cementos a evaluar; grupo 1: bturados con Biodentine™ (Septodont, Francia), grupo 2: obturados con MTA Gris (Angelus™, Londrina PR, Brasil), grupo 3: control. Se utilizó un software creado específi camente para evaluar microfi ltración; éste, por medio de sensores infrarrojos, detecta la variación de voltaje de una burbuja de aire dentro de un capilar. El programa expresa el tiempo que tarda la burbuja en pasar por el segundo sensor (mm/min), los cuales se convierten a μL/min, para después expresarlos en unidades de fi ltración, realizándosemediciones en un solo lapso. Resultados: La evaluación en este estudio de la microfi ltración apical de Biodentine™ y MTA Gris Angelus™, arrojó resultados favorables para ambos; se comprobó que no existe diferencia signifi cativa en cuanto a la microfiltración entre ellos; sin embargo, ambos materiales mostraron diferentes características en cuanto a su manipulación, tiempo de fraguado y porosidad. No se presentódiferencia estadísticamente significativa entre los grupos (p = 0.256) U Mann-Whitney y Kruskal Wallis. Conclusión: El Biodentine™ y TA Gris AngelusTM presentan un comportamiento óptimo para la obturación retrógrada. Se requiere realizar otros estudios en cuanto a la interfase con la estructura dentinaria.


Objective: To evaluate, using computational fl uid dynamics, the ability of BiodentineTM to resist microleakage when used as a retro-sealing material. Methodology: In this study, 60 single-rooted teeth were used, which were biomechanically prepared and fi lled using the standardized ProTaper single-cone technique (Dentsply, Maillefer, Switzerland) and ultrasound, using Silco root-canal sealer (Silva-Collyan, SLP, Mexico). The retrograde cavity was prepared using ultrasound and a Retro Kit (NSK Company, Japan) E31D 2 mm-diameter tip. Retrograde fi lling was performed using each of the sealers to be evaluated, as follows: group 1: sealed with BiodentineTM (Septodont, France); group 2: sealed with Grey MTA (AngelusTM, Londrina PR, Brazil); group 3: control. A specially designed software was used, which measures microleakage by using infrared sensors to detect changes in voltage in an air bubble within a capillary tube. The software expresses the time it takes (mm/min) for the bubble to pass through the second sensor, then converts these measurements into μL/min to express the rate of leakage. All of the measurements are taken considering a single interval. Results: The results of the evaluation of the apical microleakage of BiodentineTM and MTA Grey AngelusTM obtained in this study were, in both cases, favorable, proving that there is no signifi cant difference between the two in this respect. However, the characteristics of each in terms of their handling, setting time, and porosity differed. No statistically signifi cant difference between the Mann-Whitney U group and the Kruskal-Wallis group was found (p = 0.256). Conclusion: The performance of Bio-dentineTM and Gray MTA AngelusTM is ideal for retrograde fi lling pur-poses. Further studies are needed, including SEM analysis, in order to determine the quality of the seal, with respect to the interface formed with the dentin structure.


Assuntos
Infiltração Dentária/diagnóstico , Materiais Restauradores do Canal Radicular/química , Obturação Retrógrada , Desenho de Equipamento , Teste de Materiais , Porosidade , Interpretação Estatística de Dados , Ápice Dentário
8.
Am J Infect Control ; 43(10): 1092-5, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26190385

RESUMO

BACKGROUND: Biologic indicator tests (BIs) are considered the most meaningful way to verify sterilization. OBJECTIVE: To monitor the cycles of sterilization using BIs in dry heat sterilizers and steam autoclaves and to identify the causes of failures in the cycles of sterilization in dental offices in San Luis Potosí, México. METHODS: An invitation to participate was sent to 400 dental offices, and 206 practitioners of 200 dental offices were included. A questionnaire was given to each of the participants, asking for the following information: sterilizer type, operational parameters used (eg, temperature, pressure, and length of exposure), frequency of sterilization cycles per day, use of BIs, and maintenance procedures of the sterilizer. Two hundred thirty sterilizers were monitored using BIs. The sterilizers with positive results were monitored a second and third time to identify the cause of the failure. RESULTS: Twenty-two percent of practitioners (n = 46) used BIs, and 17% (n = 39) of the sterilizers reported positive results (bacterial growth). The detected failures were a mistake in the procedure (eg, temperature, time, or pressure), an absence of supervision of the procedure performed by the assistant, and improper maintenance. CONCLUSIONS: There are opportunities to increase information on infection control, to improve the adoption of standard quality control methods for sterilization as a routine process, to improve training on proper testing, and standardize processes.


Assuntos
Consultórios Odontológicos , Monitoramento Ambiental/métodos , Monitoramento Ambiental/normas , Esterilização/métodos , Esterilização/normas , Humanos , Indicadores e Reagentes , México
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA