Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Anat ; 23(2): 210-5, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20069647

RESUMO

The aim of this study was to quantify the lengths of nerve segments within the brachial plexus. Twenty cadavers were dissected bilaterally, giving a total of 40 brachial plexuses for measurement. Individual lengths of plexus segments were measured and recorded, and means and standard deviations were calculated for all data. Differences between the means were statistically evaluated using the Student's t-test. Only 3 of 16 segments were found to be longer in women on average, which included the anterior division of the superior trunk, the anterior division of the middle trunk and the posterior division of the inferior trunk. All three cords (medial, lateral, and posterior) were found to be significantly different between genders, the longer segments being in males. Significant bilateral differences were also observed when right and left brachial plexuses from each cadaver were compared. Extra lateral heads (ELHs) to the median nerve were found in 50% of brachial plexuses, the anatomy of which varied bilaterally as well as between genders. Awareness of this variability is important both to anatomists and to clinicians who operate on and around the brachial plexus.


Assuntos
Plexo Braquial/anatomia & histologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência
2.
J Pharm Biomed Anal ; 21(3): 577-83, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10701424

RESUMO

A capillary gas chromatographic-mass spectrometric (GC MS) method is described for the analysis of meperidine using 3,3,5,5-[2H4]-meperidine as an internal standard. Chromatography was performed on a (5% phenyl) methylpolysiloxane column (30 m x 0.32 mm I.D., 0.25 microm film thickness) operated at 195 degrees C; helium carrier gas-50 cm/s(-1), tR = 2.3 min. Ionization was by electron impact (EI) and detection by selected ion monitoring of the molecular ions. The method provided high response linearity (mean r = 0.9982) and precision (< 6.5% C.V.). Application of this method to a pilot study of aqueous meperidine x HCl (10 mg/ml(-1)) stability in a surgically implantable infusion pump at 37 degrees C for 90 days revealed no demonstrable drug degradation.


Assuntos
Analgésicos Opioides/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Meperidina/química , Deutério , Estabilidade de Medicamentos , Concentração de Íons de Hidrogênio , Bombas de Infusão Implantáveis , Projetos Piloto , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA