Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Front Cardiovasc Med ; 9: 839400, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387447

RESUMO

Coronary artery disease is a leading cause of death worldwide. There has been a myriad of advancements in the field of cardiovascular imaging to aid in diagnosis, treatment, and prevention of coronary artery disease. The application of artificial intelligence in medicine, particularly in cardiovascular medicine has erupted in the past decade. This article serves to highlight the highest yield articles within cardiovascular imaging with an emphasis on coronary CT angiography methods for % stenosis evaluation and atherosclerosis quantification for the general cardiologist. The paper finally discusses the evolving paradigm of implementation of artificial intelligence in real world practice.

2.
BMJ Case Rep ; 14(7)2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34257116

RESUMO

COVID-19 has been associated with significant risk for cardiac arrhythmias, particularly in patients with underlying cardiac conditions or prior histories of arrhythmia. It has been shown that a Brugada pattern can be unmasked in febrile patients with COVID-19. Herein we report a unique case of an afebrile patient without known prior history of Brugada presenting with Brugada pattern on ECG.


Assuntos
Síndrome de Brugada , COVID-19 , Arritmias Cardíacas , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Eletrocardiografia , Humanos , SARS-CoV-2
3.
BMJ Case Rep ; 14(5)2021 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-33975843

RESUMO

This report documents a rare case of COVID-19-associated constrictive pericarditis (CP) in the setting of a recent COVID-19 infection. A 55-year-old man with a history of hypertension and gout presented with acute hypoxic respiratory failure and was diagnosed with COVID-19 pneumonia with progression to acute respiratory distress syndrome. His hospital course was complicated by a large pericardial effusion; an emergent bedside transthoracic echocardiography was concerning for cardiac tamponade, so pericardiocentesis was performed. A workup with cardiac magnetic resonance imaging showed changes consistent with a diagnosis of CP. Viral and idiopathic aetiologies are the most common cause of CP in the developed world, with COVID-19 now a proposed predisposing viral illness. The virus induces systemic inflammation and pericardial changes that can lead to CP physiology. Imaging modalities including echocardiogram and cardiac magnetic resonance play an integral role in confirming the diagnosis.


Assuntos
COVID-19 , Tamponamento Cardíaco , Derrame Pericárdico , Pericardite Constritiva , Pericardite , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/cirurgia , Pericardiocentese , Pericardite Constritiva/diagnóstico por imagem , Pericardite Constritiva/etiologia , SARS-CoV-2
4.
Circ Arrhythm Electrophysiol ; 14(3): e009458, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33554620
5.
Pacing Clin Electrophysiol ; 44(4): 747-750, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33438212

RESUMO

In January 2020, the first Medtronic VDD leadless pacemaker Micra AV was approved by FDA to treat patients with advanced AV block, based on the encouraging results from the Micra Atrial tRacking using a Ventricular accELerometer 2 (MARVEL 2). There is reassuring data about safety and short-term outcomes of traditional leadless pacemaker implant after recent surgical tricuspid valve replacement, but only few cases are reported in literature. No data was found regarding AV Micra implant safety and outcomes in patients following bioprosthetic tricuspid valve replacement as of today. Our patient is a 44-year-old gentleman with history of IV drug use who recently underwent tricuspid replacement with bioprosthesis for infective endocarditis complicated by postsurgical heart block, acute kidney insufficiency requiring hemodialysis, persistent bacteremia and candidemia, and progressive failure of the epicardial pacing wires. Given the elevated infective risk, the decision of attempting leadless pacer implant through the bioprosthetic valve was taken and our patient underwent successful Micra AV implant on postoperative day 30. To our knowledge, this is the first AV Micra placement following bioprosthetic tricuspid valve replacement. The uneventful procedure and the encouraging short-term device follow-up results seem to confirm the relative safety of this device in treating advanced atrioventricular conduction disorders in patients at elevated infective risk.


Assuntos
Endocardite Bacteriana/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Marca-Passo Artificial , Valva Tricúspide/cirurgia , Adulto , Bioprótese , Burkholderia cepacia/isolamento & purificação , Candida/isolamento & purificação , Ecocardiografia , Eletrocardiografia , Endocardite Bacteriana/microbiologia , Escherichia coli/isolamento & purificação , Humanos , Masculino , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação
7.
Case Rep Cardiol ; 2020: 8882561, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33110661

RESUMO

A 19-year-old healthy male collegiate athlete presented with typical anginal symptoms after running a 5K race. He had complained of similar symptoms off and on for the past month. On presentation, troponin was 0.12 ng/ml (reference value < 0.01 ng/ml), which peaked at 17.7 ng/ml and CK-MB was 28.71 IU/L (reference value < 25 IU/L). ECG showed diffuse biphasic T-waves. Coronary computed tomography angiogram (cCTA) demonstrated a 1.5 cm dissection in the left anterior descending artery and a 1.9 × 1.8 cm attenuation defect in the left ventricular apex consistent with thrombus. Subsequent coronary catheterization confirmed dissection of the left anterior descending artery. Spontaneous coronary artery dissection (SCAD) is a rare phenomenon. Diagnosis can be made through noninvasive measures but is usually done through left heart catheterization. In young patients who present with an NSTEMI, clinical suspicion for SCAD among other conditions should be raised. Additionally, recognizing that complications such as intracardiac thrombi can occur in SCAD is critical in ensuring appropriate therapy.

8.
Am J Cardiol ; 123(11): 1845-1852, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30922540

RESUMO

Transcatheter aortic valve implantation (TAVI) is an acceptable treatment for severe aortic stenosis in high or intermediate risk patients. Conduction abnormalities are a known complication of TAVI. Most abnormalities occur perioperatively but can develop later. The predictors of delayed conduction abnormalities are unknown. Patients who underwent TAVI at our institution were reviewed. Patients with a pre-existing pacemaker were excluded. Baseline, in-hospital, and 30-day follow-up ECGs were reviewed. Patient and procedural characteristics were analyzed to look for predictors of acute and delayed abnormalities. Ninety-eight patients were included. All valves implanted were balloon expandable, most commonly SAPIEN S3 (78%). Thirty-seven (37.7%) patients developed abnormalities before discharge. Of these patients, 20 (57.1%) had complete resolution at 30-day follow-up. No patients with new conduction abnormalities during hospitalization had additional abnormalities at 30-day follow-up. Five (5.1%) patients developed new conduction abnormalities following discharge. Overall, 22 (22.4%) patients had conduction abnormalities at 30-day follow-up which were not present at baseline. Predilatation (p = 0.003), higher ratios of balloon (p = 0.03) or valve (p = 0.05) size to left ventricular outflow tract, and previous myocardial infarction (p = 0.034) were predictive of acute conduction abnormalities. Baseline right bundle branch block (p = 0.002), longer baseline (p <0.001) and discharge (p = 0.004) QRS duration, moderate, or severe aortic insufficiency (p = 0.002) and atrial fibrillation (p = 0.031) were predictors of new conduction abnormalities after discharge. In conclusion, most new in-hospital conduction abnormalities resolve by 30-day follow-up. In-hospital conduction abnormalities are related to technical aspects of TAVI while delayed conduction abnormalities are related to baseline conduction system disease.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença do Sistema de Condução Cardíaco/etiologia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
PLoS One ; 11(2): e0148189, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26840403

RESUMO

Atrial fibrillation (AF) is the most common sustained arrhythmia in patients with chronic kidney disease (CKD). In this study, we examined the association between inflammation and AF in 3,762 adults with CKD, enrolled in the Chronic Renal Insufficiency Cohort (CRIC) study. AF was determined at baseline by self-report and electrocardiogram (ECG). Plasma concentrations of interleukin(IL)-1, IL-1 Receptor antagonist, IL-6, tumor necrosis factor (TNF)-α, transforming growth factor-ß, high sensitivity C-Reactive protein, and fibrinogen, measured at baseline. At baseline, 642 subjects had history of AF, but only 44 had AF in ECG recording. During a mean follow-up of 3.7 years, 108 subjects developed new-onset AF. There was no significant association between inflammatory biomarkers and past history of AF. After adjustment for demographic characteristics, comorbid conditions, laboratory values, echocardiographic variables, and medication use, plasma IL-6 level was significantly associated with presence of AF at baseline (Odds ratio [OR], 1.61; 95% confidence interval [CI], 1.21 to 2.14; P = 0.001) and new-onset AF (OR, 1.25; 95% CI, 1.02 to 1.53; P = 0.03). To summarize, plasma IL-6 level is an independent and consistent predictor of AF in patients with CKD.


Assuntos
Fibrilação Atrial/sangue , Interleucina-6/sangue , Insuficiência Renal Crônica/sangue , Adulto , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Proteína C-Reativa/metabolismo , Eletrocardiografia , Feminino , Seguimentos , Humanos , Proteína Antagonista do Receptor de Interleucina 1/sangue , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/fisiopatologia , Fatores de Risco , Fator de Crescimento Transformador beta/sangue , Fator de Necrose Tumoral alfa/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA