Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Genes (Basel) ; 15(1)2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38275588

RESUMO

Primary ovarian failure (POF) is caused by follicle exhaustion and is associated with menstrual irregularities and elevated gonadotropin levels, which lead to infertility before the age of 40 years. The etiology of POI is mostly unknown, but a heterogeneous genetic and familial background can be identified in a subset of cases. Abnormalities in the fragile X mental retardation 1 gene (FMR1) are among the most prevalent monogenic causes of POI. These abnormalities are caused by the expansion of an unstable CGG repeat in the 5' untranslated region of FMR1. Expansions over 200 repeats cause fragile X syndrome (FXS), whereas expansions between 55 and 200 CGG repeats, which are defined as a fragile X premutation, have been associated with premature ovarian failure type 1 (POF1) in heterozygous females. Preimplantation genetic testing for monogenic diseases (PGT-M) can be proposed when the female carries a premutation or a full mutation. In this narrative review, we aim to recapitulate the clinical and molecular features of POF1 and their implications in the context of PGT-M.


Assuntos
Síndrome do Cromossomo X Frágil , Insuficiência Ovariana Primária , Feminino , Humanos , Regiões 5' não Traduzidas , Alelos , Proteína do X Frágil da Deficiência Intelectual/genética , Síndrome do Cromossomo X Frágil/genética , Testes Genéticos , Mutação , Insuficiência Ovariana Primária/genética
2.
Biomed Res Int ; 2021: 1126270, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34722756

RESUMO

In IVF centers, risk assessment applies to complex processes potentially accounting for adverse events and reactions that undergo well-established legislative oversight, and nonconformances (NCs), that lack of established tracking systems. NCs account for an integral part of the quality management system, so that their documentation is important. The study evaluated the performance of a customized tool for incident reporting (IR) to track and characterize NCs in a public IVF center. IVF operators used the IVF-customized IR tool to record NCs at the moment of detection or subsequently, and in a time-saving manner during daily practice. From February 2015 to February 2020, 635 NCs were reported leading to the implementation of 10 operative instructions and 3 procedures with corrective strategies. NCs referred to the IVF laboratory were the most numerically meaningful (454/635, 71.5%). The majority (352/454, 77.5%) accounted for NCs related to procedures of sample management; considering the analytical phase as all the procedures involving sample treatment, the intra-analytical phase (176/352, 50%) has always been more subject to NCs compared to pre- (102/352, 29%) and postanalytical (74/352, 21%) phases. Our experience showed that the IVF-customized IR tool is suitable for application in IVF with regard to NC reports and documentation, as it identifies the most vulnerable steps of treatments. It manages NCs over the time, but it requires a contextual understanding of its application in order to avoid NC underestimates that could negatively influence the safety and quality aspects of IVF treatments.


Assuntos
Fidelidade a Diretrizes/tendências , Medição de Risco/métodos , Gestão de Riscos/métodos , Documentação , Fertilização in vitro/métodos , Fidelidade a Diretrizes/estatística & dados numéricos , Humanos , Itália , Software
3.
J Assist Reprod Genet ; 38(3): 681-688, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33432422

RESUMO

PURPOSE: The main purpose and research question of the study are to compare the efficacy of high-security closed versus open devices for human oocytes' vitrification. METHODS: A prospective randomized study was conducted. A total of 737 patients attending the Infertility and IVF Unit at S.Orsola University Hospital (Italy) between October 2015 and April 2020 were randomly assigned to two groups. A total of 368 patients were assigned to group 1 (High-Security Vitrification™ - HSV) and 369 to group 2 (Cryotop® open system). Oocyte survival, fertilization, cleavage, pregnancy, implantation, and miscarriage rate were compared between the two groups. RESULTS: No statistically significant differences were observed on survival rate (70.3% vs. 73.3%), fertilization rate (70.8% vs. 74.9%), cleavage rate (90.6% vs. 90.3%), pregnancy/transfer ratio (32.0% vs. 31.8%), implantation rate (19.7% vs. 19.9%), nor miscarriage rates (22.1% vs. 21.5%) between the two groups. Women's mean age in group 1 (36.18 ± 3.92) and group 2 (35.88 ± 3.88) was not significantly different (P = .297). A total of 4029 oocytes were vitrified (1980 and 2049 in groups 1 and 2 respectively). A total of 2564 were warmed (1469 and 1095 in groups 1 and 2 respectively). A total of 1386 morphologically eligible oocytes were inseminated by intracytoplasmic sperm injection (792 and 594 respectively, P = .304). CONCLUSIONS: The present study shows that the replacement of the open vitrification system by a closed one has no impact on in vitro and in vivo survival, development, pregnancy and implantation rate. Furthermore, to ensure safety, especially during the current COVID-19 pandemic, the use of the closed device eliminates the potential samples' contamination during vitrification and storage.


Assuntos
COVID-19/epidemiologia , Oócitos/fisiologia , Oócitos/virologia , Técnicas de Reprodução Assistida/normas , Adulto , Criopreservação/métodos , Criopreservação/normas , Implantação do Embrião/fisiologia , Transferência Embrionária/métodos , Feminino , Fertilização in vitro/métodos , Fertilização in vitro/normas , Humanos , Itália , Doação de Oócitos/métodos , Doação de Oócitos/normas , Pandemias , Gravidez , Taxa de Gravidez , Estudos Prospectivos , SARS-CoV-2/isolamento & purificação , Injeções de Esperma Intracitoplásmicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA