Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Eye (Lond) ; 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615097

RESUMO

PURPOSE: This study aims to investigate inter-image intra-observer variability of macular, and optic disc (ONH) microvasculature measurements of glaucomatous and normal subjects using Swept-Source Optical Coherence Tomography Angiography (OCT-A) (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation, JAPAN) - based imaging data analysis and processing with a newly made quantitative approach. METHODS: A total of 20 glaucomatous and 20 healthy eyes underwent three OCT-A scanning of the ONH and macula. Macular and papillary and peripapillary vascular networks were calculated. For each eye, eighteen scans were analyzed using a novel approach: custom MATLAB 2021b scripts were employed for imaging analyses. Grayscale distribution was performed using the histcounts MATLAB function with 51 bins. For all layers, the vascular layer coefficient of variation (vl CoV) of the three measures were performed. The vl CoV difference between the two groups was analyzed by Student t-test. RESULTS: In glaucomatous eyes, the vl CoV ranged from 4.49% to 8.54%, while in the control group from 3.58% to 8.32%. Both groups exhibited higher CoVs when assessing the optic disc. The papillary and macular microvasculature reproducibility was comparable between groups. CONCLUSIONS: Utilizing Swept-Source OCT-A images our study has identified an easy and reproducible method that appears to be fast and can assist physicians in assessing macular and ONH perfusion with less inter-image variability, particularly in the 70 µm superficial area of the optic disc. The high reliability obtained suggested that this method could be useful as early clinical biomarker.

2.
Ophthalmol Ther ; 12(2): 1315-1326, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36826753

RESUMO

INTRODUCTION: Postoperative endophthalmitis is typically caused by the patient's conjunctival bacterial flora. Povidone iodine solution (5%) is used perioperatively to obtain periocular and ocular antisepsis. However, an adjunctive prophylaxis procedure could further help control the conjunctival microbial load. Considering the increase in antibiotic resistance, a progressive shift toward alternative methods would be desirable. Somilux® eye drops (Alfa Intes, lactoferrin-based eye drops) are medical devices containing liposomal lactoferrin (LF). This study evaluates the effects on conjunctival microflora of LF-based eye drops used in the preoperative phase in patients scheduled for cataract surgery. METHODS: LF-based eye drops or a vehicle solution (water solution) were instilled 4 times a day starting 3 days before cataract surgery. Before the therapy (T0) and at the time of surgery (T1), a conjunctival swab was performed in both eyes and processed to detect microbial growth, microbiological isolation, and species identification. The outcome was the quantification and characterization of the local microbial flora before and after using LF-based or vehicle-based eye drops. Safety of the treatments was also evaluated. RESULTS: 88 eyes of 44 patients (mean [± SD] age 75 [± 12.6] years) were enrolled. At baseline, 54 conjunctival swabs showed only saprophytic flora, 27 showed only potential pathogenic flora, and seven showed both of them. LF-based eye drops reduced the proportion of potentially pathogenic bacteria (36% at T0 vs. 9% at T1, p = 0.008) compared with the vehicle (41% at T0 vs. 55% at T1, p = 0.302) without altering the physiological ocular microbial composition. No adverse events have been reported. CONCLUSION: Our findings provide a novel contribution to the scientific knowledge on the role of LF in the ophthalmic field, supporting the use of LF-based eye drops as a safe and selective treatment to improve the ocular surface physiological defenses and control the bacterial ocular surface contamination prior to cataract surgery.

3.
Br J Ophthalmol ; 107(1): 62-65, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34433548

RESUMO

INTRODUCTION: Laser trabeculoplasty is an effective and widely used treatment for glaucoma. A new laser technology, the Eagle direct selective laser trabeculoplasty (DSLT) device, may provide automated, fast, simple, safe and effective laser treatment for glaucoma in a broader range of clinical settings. This trial aims to test the hypothesis that translimbal DSLT is effective and not inferior to selective laser trabeculoplasty (SLT) in reducing intraocular pressure (IOP) in open angle glaucoma (OAG). METHODS AND ANALYSIS: This is a multicentre, randomised, controlled, investigator-masked study. The primary efficacy outcome is intergroup difference in mean change from baseline IOP measured at 6 months. Secondary outcomes include mean percentage reduction in IOP at 3, 6 and 12 months; proportion of participants with at least 20% reduction in IOP from baseline at 6 months; change in ocular hypotensive medications at 12 months and evaluation of safety. Participants were aged >= 40 years with OAG, including exfoliative or pigmentary glaucoma, or ocular hypertension with untreated or washed out IOP 22-35 mm Hg. TREATMENTS: DSLT: 120 shots, 3 ns, 400 µm spot size, energy 1.4-1.8 mJ delivered at the limbus over 2 s. SLT: approximately 100 shots, 3 ns, 400 µm spot size administered 360 degrees at the limbus using any gonioscopy lens, energy 0.3-2.6 mJ. A sample size of 164 is sufficient to detect a non-inferiority margin of 1.95 mm Hg for change from baseline IOP. CLINICAL TRIAL REGISTRATION NUMBER: NCT03750201, ISRCTN14033075.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Terapia a Laser , Trabeculectomia , Humanos , Trabeculectomia/métodos , Pressão Intraocular , Terapia a Laser/métodos , Glaucoma/cirurgia , Resultado do Tratamento
4.
Int Ophthalmol ; 43(5): 1745-1749, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36418806

RESUMO

PURPOSE: To describe reoperations in the operating room for complications that occurred within the first 90 days after gel stent implantation or trabeculectomy at a single institution over 5 years. METHODS: In this retrospective chart review, patients who have undergone gel stent implantation with mitomycin C (MMC) or trabeculectomy with MMC were enrolled. Postoperative complications that required reoperations within the first 90 days were evaluated. RESULTS: A total of 510 surgeries were performed on 392 patients over a 57-month period by 2 glaucoma surgeons. Of these, 284 were gel stent implantation, and 226 were trabeculectomy. Combined phacoemulsification was performed in 52/284 (18.3%) in the gel stent group and in 26/226 (11.5%) of eyes in the trabeculectomy group (p = 0.03). Reoperations took place in 13/510 (2.5%) eyes, including 4/284 (1.4%) in the gel stent group, 9/226 (4.0%) in the trabeculectomy group (p = 0.07). In the gel stent group, indications for reoperation were bleb failure (2), suprachoroidal hemorrhage (1), bullous keratopathy (1). In the trabeculectomy group, indications for reoperation were bleb failure (3), overfiltration (2), persistent wound leak (2), aqueous misdirection (2). CONCLUSIONS: The rates of reoperation for early postoperative complications after gel stent or trabeculectomy was low and comparable with previous studies. A slightly higher number of reoperations within 90 days was observed in the trabeculectomy group than the gel stent group despite the more significant number of combined procedures in the latter group. Bleb failure was the most common indications for reoperation in both groups. Excessive outflow was a cause of reoperation mostly in the trabeculectomy group.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Trabeculectomia/métodos , Estudos Retrospectivos , Pressão Intraocular , Reoperação , Glaucoma/cirurgia , Mitomicina , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Resultado do Tratamento
6.
J Glaucoma ; 31(12): 979-981, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939834

RESUMO

INTRODUCTION: To report a case of hyphema after a bleb needling revision in a PreserFlo MicroShunt implantation. CASE DESCRIPTION: An 87-year-old man suffering from bilateral open angle glaucoma was referred to our hospital with a diagnosis of unsatisfactory intraocular pressure (IOP) control in the right eye, despite the maximally tolerated medical therapy. The patient underwent PreserFlo MicroShunt implantation in his right eye. About 2 months after the surgical procedure, the IOP was raised because of bleb failure for subconjunctival scarring. A needling revision was performed at the slit lamp. During the procedure blood reflux through a PreserFlo MicroShunt device from a filtering bleb to the anterior chamber was observed, causing an IOP rise. Treatment with oral acetazolamide, topical steroid, and antibiotic resulted in the complete resolution of the hyphema in 2 weeks and a significant lowering in IOP. CONCLUSIONS: This is the first reported case of blood reflux to the anterior chamber through a PreserFlo MicroShunt implant after a needling procedure.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Idoso de 80 Anos ou mais , Humanos , Masculino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Hifema , Pressão Intraocular , Tonometria Ocular , Trabeculectomia/métodos
7.
J Clin Neurol ; 18(3): 334-342, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35589321

RESUMO

BACKGROUND AND PURPOSE: To identify changes in the choroidal thickness (CT) in multiple sclerosis (MS) patients with and without optic neuritis (ON) using enhanced-depth-imaging optical coherence tomography (EDI-OCT). METHODS: This cross-sectional study included 96 eyes with MS and 28 eyes of healthy controls. All participants underwent an ophthalmologic examination and EDI-OCT scanning (Spectralis, Heidelberg Engineering, Germany) to assess the CT and the retinal nerve fiber layer (RNFL) thickness. MS patients were divided into two groups: 1) with and 2) without a history of ON. The CT was evaluated in the fovea and at six horizontal and six vertical points at 500, 1,000, and 1,500 µm from the fovea. Paired t-tests were used to compare the groups, and p-value<0.05 was considered as significant. RESULTS: At all 13 measurements points, the CT was thicker in MS patients than in the healthy controls and was thinner in eyes with ON than in the contralateral eyes, but these differences were not statistically significant. However, the CT was always larger in all points in eyes with a history of ON than in the control eyes. The RNFL was significantly thinner (p<0.05) in both MS and ON eyes than in the control eyes. CONCLUSIONS: The CT did not differ between MS and control eyes, but it was significantly larger in patients with a history of ON, in whom the RNFL was thinner. Further studies are necessary to establish the possible role of the choroid in MS.

8.
J AAPOS ; 26(2): 71.e1-71.e4, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35307544

RESUMO

PURPOSE: To compare retinal vessel density before and after strabismus surgery using swept-source optical coherence tomography angiography (SS-OCTA). METHODS: In this longitudinal, single-arm pilot study, vascular density in the deep capillary plexus (DCP), superficial retinal capillary plexus (SCP) and choriocapillaris layer (CCL) in consecutive subjects undergoing strabismus surgery was assessed using SS-OCTA preoperatively (T0), on the first day postoperatively (POD1), and 30 days postoperatively (POD30). RESULTS: A total of 92 eyes of 56 patients (54% males) were included. Mean patient age was 41.1 ± 22.7. OCT vascular density of the DCP was 50.20 ± 5.57 at T0, 52.74 ± 4.77 at POD1, and 50.92 ± 4.58 at POD30. The differences were statistically significant for T0 versus POD1 (P < 0.05). Vascular density of the CCL was 50.72 ± 4.80 at T0, 53.59 ± 3.65 at POD1, and 51.39 ± 4.64 at POD30. The differences were statistically significant for T0 versus POD1 (P < 0.05). No significant differences were found in SCP (P > 0.05). CONCLUSIONS: Transitory hemodynamic changes can occur in the DCP and in the CCL following muscle recession procedures.


Assuntos
Estrabismo , Tomografia de Coerência Óptica , Feminino , Angiofluoresceinografia/métodos , Humanos , Masculino , Projetos Piloto , Vasos Retinianos/diagnóstico por imagem , Estrabismo/cirurgia , Tomografia de Coerência Óptica/métodos
9.
Eur J Ophthalmol ; 32(1): NP254-NP257, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33143445

RESUMO

A 41-year-old woman has come to our attention complaining of decreased visual acuity and monocular diplopia associated with upper and lower limb hypoesthesia. Malabsorption syndrome with vitamin A and E deficiency developed after a bariatric biliopancreatic diversion. The clinical ophthalmological signs and symptoms improved after oral vitamin supplementation therapy. The past medical history is essential in the case of a patient complaining of visual symptoms compatible with vitamin deficiency in order to detect the cause and to start a prompt therapy to avoid irreversible neurological and visual sequelae. The clinical features of our case closely resemble other cases described in the literature of patients affected by vitamin A and E deficiency secondary to malabsorption syndrome.


Assuntos
Desvio Biliopancreático , Síndromes de Malabsorção , Adulto , Feminino , Humanos , Síndromes de Malabsorção/diagnóstico , Síndromes de Malabsorção/etiologia , Vitaminas/uso terapêutico
10.
Graefes Arch Clin Exp Ophthalmol ; 260(2): 571-576, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34468829

RESUMO

PURPOSE: The aim of this study is to evaluate the changes in macular blood flow index (BFI) in patients with moderate to severe thyroid-associated orbitopathy (TAO) before and after pulse therapy and their relationship with clinical features and disease activity using angio-OCT technology. METHODS: We analyzed twenty-four eyes. Every patient underwent a complete eye examination and angio-OCT analysis (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation) before (T0) and two months (T2) after pulse therapy. We analyzed macular vascular blood flow in four angiographic levels: superficial plexus (SP), deep plexus (DP), external retina (ER), and choriocapillaris (CC). We used the clinical activity score (CAS) score to define TAO as moderate or severe. RESULTS: Macular BFI significantly increased at T2 in the DP, ER, and CC (p < 0.01). CAS score (5.8 ± 0.8 vs. 3.9 ± 0.9, p < 0.01) and Hertel exophthalmometry values (22.6 ± 2.3 mm vs. 21.2 ± 2,5 mm, p < 0.01) improved for all patients at T2 compared T0. Mean IOP increased from 13.3 ± 2.8 mmHg to 14.3 ± 2.1 mmHg (p < 0.01). No correlation was found between CAS score and macular BFI in all the analyzed levels. CONCLUSIONS: Pulse therapy treatment can change macular BFI. In particular, two months alter pulse therapy, all the patients show an increase in macular vascular blood flow in each angiographic level. According to our results, angio-OCT analysis of the macular BFI may be a useful tool in the follow-up of TAO patients after pulse therapy.


Assuntos
Oftalmopatia de Graves , Corticosteroides , Corioide , Angiofluoresceinografia , Oftalmopatia de Graves/diagnóstico , Oftalmopatia de Graves/tratamento farmacológico , Humanos , Infusões Intravenosas , Tomografia de Coerência Óptica
12.
Ophthalmol Ther ; 10(4): 1025-1032, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34495493

RESUMO

INTRODUCTION: The control of conjunctival microbial load is crucial for patients receiving intravitreal injections (IVTs) in order to reduce the risk of endophthalmitis. The purpose of this work was to assess the antimicrobial activity of a new commercial ocular spray containing Biosecur citrus extract (Oftasecur®, Off Health, Florence, Italy). METHODS: This prospective cross-sectional pilot study included patients receiving IVTs who were instructed to apply Oftasecur spray onto the eye to be injected four times daily starting 4 days before surgery. The contralateral eye was considered the control. A conjunctival swab for microbiological analysis was performed in both eyes before starting study treatment and at the time of the injection. The Brief Ocular Discomfort Inventory (BODI) questionnaire was administered to patients based on an 11-point scale (0 for no discomfort and 10 for maximum discomfort). RESULTS: Thirty patients (15 male, 15 female; mean age 64.7 ± 11.6 [standard deviation, SD] years) were included. Before starting treatment, 53.3% of the total eyes tested positive during the microbiological analysis. After the treatment period, only 20% of the eyes tested positive at the time of injection, showing a significant reduction in the microbial load (p < 0.01). Moreover, in the treated arm, the positive swabs before and after the prophylactic treatment with Oftasecur ocular spray showed a significant reduction (from 70.4% to 29.6%; p = 0.003, McNemar's test). Oftasecur ocular spray was well tolerated, with an average BODI score of 1.2 (± 0.70 SD). CONCLUSION: Oftasecur ocular spray showed antimicrobial activity that significantly reduced the microbial load in patients receiving intravitreal injections. Therefore, it may have a role in the prophylaxis of infection in the setting of IVTs.

13.
Sci Rep ; 11(1): 12647, 2021 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-34135447

RESUMO

Ultrasound cyclo plasty (UCP) is a recently developed surgical technique for glaucoma allowing a selective and controlled coagulation of the ciliary body. We herein investigated the long-term efficacy and safety of UCP for the treatment of glaucoma. This prospective study included patients with primary and secondary glaucoma. All surgeries were performed using the EyeOP1 device (Eye Tech Care, Rillieux-la-Pape, France). Sixty-six patients were included, and 60 completed regularly the 2-year follow-up. Preoperative IOP was 28.5 ± 9.6 mmHg and significantly decreased to 17.0 ± 5.4 at 2 years (p < 0.001). The daily number of both hypotensive eye drops and acetazolamide tablets decreased significantly (respectively, from 2.6 ± 1.1 to 1.7 ± 1.2 and from 0.7 ± 0.8 to 0.2 ± 0.5; both p < 0.001). At 2 years, 68.1% of patients met the definition of qualified success (IOP < 21 mmHg regardless of glaucoma medications) and 10.3% of patients met the definition of complete success (IOP < 21 mmHg without glaucoma medications). No major intra- or postoperative complications occurred; however, 15 eyes required additional glaucoma surgery. These results suggest that UCP is an effective and safe procedure to reduce IOP in glaucoma patients through a 2-year follow-up period.


Assuntos
Glaucoma/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento
14.
Semin Ophthalmol ; 36(7): 541-548, 2021 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-33734926

RESUMO

Background: Blue blocking (BB) lenses, including spectacles and intraocular lenses, work by attenuating short-wavelength light. BB glasses are being marketed with the aim to reduce eye fatigue symptoms when using digital devices, improve sleep quality and potentially confer protection from retinal phototoxicity. BB intraocular lenses following cataract surgery may be implanted because they are thought to prevent age-related macular degeneration (AMD) progression.Methods: The present study is a systematic review aiming to analyze BB lenses clinical efficacy in preventing blue light-related ocular disorders, including AMD progression, eye fatigue, and their impact on sleep quality. We searched Medline, PubMed, Web of Science and the Cochrane Library until May 2020.Results:Although several studies have been performed investigating BB lenses, clinical efficacy for preventing or attenuating the above-mentioned ocular disorders is often theorical or based on laboratory or animal experiments. Conclusions: To date, there is a lack of consistent evidence for a larger-sclale introduction of BB lenses in the routine clinical practice.


Assuntos
Extração de Catarata , Cristalino , Lentes Intraoculares , Degeneração Macular , Animais , Humanos , Luz
15.
Eur J Ophthalmol ; 31(3): 938-942, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32515611

RESUMO

PURPOSE: To analyze biometric changes and prevalence of refractive in patients with neurofibromatosis type 1 (NF1). METHODS: Retrospective, case-controlled study involving patients affected by NF1 and healthy control subjects. Data on biometric measurements such as axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), keratometry (K1 and K2) values, and white-to-white (WTW), obtained by use of optical low-coherence reflectometry on a Lenstar LS 900® (Haag-Streit AG, Switzerland) were collected and analyzed. Cycloplegic refractions were then performed. RESULTS: Overall, 166 eyes of 83 patients diagnosed with NF1 (mean age 21.6 ± 9.8) were enrolled and compared with 178 eyes of age-matched healthy subjects (mean age 22.6 ± 6.6). One hundred sixty-six (22.8%) and 33 of 178 (18.5%) eyes were myopic in NF1 patients and healthy subjects, respectively. The prevalence of hyperopia in the NF1 group was 12 of 166 (7.2%) whereas in the healthy control group was 14 of 178 (8.9%). Twenty-nine of 166 (17.4%) and 34 of 178 (19.1%) eyes presented astigmatism in NF1 and control group, respectively. These differences were not statistically significant (p-values > 0.05). Refractive errors such as myopia, hyperopia, and astigmatism were similar between the two groups. The difference of AL, CCT, ACD, LT, K values, and WTW were no statistically significant between the two groups (p-values > 0.05). CONCLUSION: Refractive errors and ocular biometric parameter seem not to be an addition findings of NF1.


Assuntos
Neurofibromatose 1 , Erros de Refração , Adulto , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/diagnóstico por imagem , Biometria , Humanos , Neurofibromatose 1/diagnóstico , Neurofibromatose 1/epidemiologia , Erros de Refração/diagnóstico , Erros de Refração/epidemiologia , Estudos Retrospectivos , Adulto Jovem
16.
Br J Ophthalmol ; 105(4): 484-489, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32522789

RESUMO

BACKGROUND/AIMS: To compare the accuracy of 13 formulas for intraocular lens (IOL) power calculation in cataract surgery. METHODS: In this retrospective interventional case series, optical biometry measurements were entered into these formulas: Barrett Universal II (BUII) with and without anterior chamber depth (ACD) as a predictor, EVO 2.0 with and without ACD as a predictor, Haigis, Hoffer Q, Holladay 1, Holladay 2AL, Kane, Næser 2, Pearl-DGS, RBF 2.0, SRK/T, T2 and VRF. The mean prediction error (PE), median absolute error (MedAE), mean absolute error and percentage of eyes with a PE within ±0.25, ±0.50, ±0.75 and ±1.00 diopters (D) were calculated. RESULTS: Two hundred consecutive eyes were enrolled. With all formulas, the mean PE was zero. The BUII with no ACD had the lowest standard deviation (±0.343 D), followed by the T2 (0.347 D), Kane (0.348 D), EVO 2.0 with no ACD (0.348 D) and BUII with ACD (0.353 D) formulas. The difference among the MedAEs of all formulas was statistically significant (p<0.0001); the lowest values were achieved with the Kane (0.214 D), RBF 2.0 (0.215 D), BUII with and without ACD (0.218 D) and SRK/T (0.223 D). A percentage ranging from 80% to 88.5% of eyes showed a PE within ±0.50 D and all formulas achieved more than 50% of eyes with a PE within ±0.25 D. CONCLUSION: All investigated formulas achieved good results; there was a tendency towards better outcomes with newer formulas. Traditional formulas can still be considered an accurate option.


Assuntos
Interferometria/métodos , Lentes Intraoculares , Óptica e Fotônica , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Comprimento Axial do Olho/diagnóstico por imagem , Extração de Catarata , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos
17.
Eye (Lond) ; 35(2): 544-547, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32350454

RESUMO

OBJECTIVES: To compare motor skills in patients with infantile strabismus and age and sex-matched control subjects aged 5-11 years. METHODS: Motor performances were assessed by the Italian version of Developmental Coordination Disorder Questionnaire 2007 (DCDQ) in children with infantile strabismus and age and sex-matched control subjects. Patients affected by specific neurological, cognitive and behavioural disorders were excluded from the study. RESULTS: There were 43 patients included in the study, 23 in the strabismus group (14 males, 9 females, mean age 7.5 ± 2.0 years) and 24 in the control group (14 males and 10 females, mean age 7.2 ± 1.7 years. The overall DCDQ score was significantly lower in children with strabismus compared with control subjects (58.7 ± 11.3 vs. 74.2 ± 1.5; P < 0.001). Children with strabismus and no stereopsis showed a lower DCDQ score compared with those with normal stereopsis (50.8 ± 9.5 vs. 67.3 ± 4.8; P < 0.001). CONCLUSION: Motor skills are reduced in children with strabismus compared with control subjects. Strabismus and lack of binocular vision are factors potentially contributing to developmental coordination disorder.


Assuntos
Transtornos das Habilidades Motoras , Estrabismo , Criança , Pré-Escolar , Feminino , Humanos , Itália , Masculino , Destreza Motora , Inquéritos e Questionários , Visão Binocular
18.
Eur J Ophthalmol ; 31(2): 698-703, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32066268

RESUMO

PURPOSE: The purpose of the present study was to compare visual function assessment, visual evoked potential, and optical coherence tomography with measurement of retinal nerve fiber layer thickness for the diagnosis of optic pathway glioma in children with neurofibromatosis type 1. METHODS: This retrospective observational study included patients with neurofibromatosis type 1 who underwent brain magnetic resonance imaging scan, visual evoked potential study, and peripapillary retinal nerve fiber layer evaluation by optical coherence tomography. Patients were tested with pattern-reversal visual evoked potential and with flash visual evoked potential in case of poor cooperation. Optical coherence tomography was performed with HRA Spectralis (Heidelberg Engineering, Heidelberg, Germany). The area under the curve of receiver operating characteristic curves was used to evaluate the accuracy of each parameter for diagnosing optic pathway glioma. RESULTS: In all, 110 patients with neurofibromatosis type 1 were included in the study. Fifty of them had an optic pathway glioma diagnosed with magnetic resonance imaging, while 60 did not. Global retinal nerve fiber layer thickness demonstrated the highest diagnostic power for discriminating patients with and without optic pathway glioma (area under the curve = 0.758, sensitivity = 65.3%, specificity = 83.3%), followed visual acuity (area under the curve = 0.723, sensitivity = 51.1%, specificity = 91.7%) and P100 of visual evoked potential (area under the curve = 0.712, sensitivity = 69.6%, specificity = 63.8%). CONCLUSION: The results of the present study showed that the measurement of retinal nerve fiber layer thickness was the most efficient test for discriminating patients with and without optic pathway glioma. Brain magnetic resonance imaging remains the gold standard to confirm the diagnosis of optic pathway glioma. Longitudinal studies are required to define if the early detection of tumors with optical coherence tomography could prevent vision loss and morbidity.


Assuntos
Potenciais Evocados Visuais/fisiologia , Neurofibromatose 1/fisiopatologia , Glioma do Nervo Óptico/fisiopatologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Seleção Visual/métodos , Acuidade Visual , Adolescente , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Fibras Nervosas/patologia , Neurofibromatose 1/diagnóstico , Glioma do Nervo Óptico/diagnóstico , Curva ROC , Estudos Retrospectivos , Campos Visuais/fisiologia
19.
Br J Ophthalmol ; 105(2): 174-179, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32245849

RESUMO

AIMS: To evaluate bilateral morphometric changes of corneal sub-basal nerve plexus (CSNP) occurring after unilateral cataract surgery by in vivo confocal microscopy (IVCM) images analysed with automated software. METHODS: IVCM was performed before (V0) and 1 month after surgery (V1) in both operated eyes (OEs) and unoperated eyes (UEs) of 30 patients. Thirty age and sex-matched subjects acted as controls. Corneal nerve fibre density (CNFD), corneal nerve branch density (CNBD), corneal nerve fibre length (CNFL), corneal nerve total branch density (CTBD), corneal nerve fibre area (CNFA), corneal nerve fibre width, corneal nerve fractal dimension (CNFrD) and dendritic cells density were calculated. RESULTS: Mean CNFD, CNBD, CNFL, CTBD, CNFA and CNFrD significantly decreased at V1 versus V0 in both eyes (respectively, 15.35±7.00 vs 21.21±6.56 n/mm2 in OEs and 20.11±6.69 vs 23.20±7.26 in UEs; 13.57±12.16 vs 26.79±16.91 n/mm2 in OEs and 24.28±14.88 vs 29.76±15.25 in UEs; 9.67±3.44 mm/mm2 vs 13.49±3.42 in OEs and 12.53±3.60 vs 14.02±3.82 in UEs; 22.81±18.77 vs 42.25±24.64 n/mm2 in OEs and 38.06±20.52 vs 43.93±22.27 in UEs; 0.0040±0.0021 vs 0.0058±0.0020 mm2/mm2 in OEs and 0.0049±0.0016 vs 0.0057±0.0019 in UEs; 1.418±0.058 vs 1.470±0.037 in OEs and 1.466±0.040 vs 1.477±0.036 in UEs; always p<0.049). CONCLUSION: Patients undergoing cataract surgery exhibit bilateral alterations of CSNP. This finding could have broad implications in the setting of sequential cataract surgery.


Assuntos
Doenças do Sistema Nervoso Autônomo/diagnóstico , Córnea/inervação , Fibras Nervosas/patologia , Nervo Oftálmico/patologia , Facoemulsificação/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Doenças do Sistema Nervoso Autônomo/etiologia , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Microscopia Confocal , Nervo Oftálmico/diagnóstico por imagem , Estudos Prospectivos
20.
Cornea ; 40(2): 251-253, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32858542

RESUMO

ABSTRACT: We report on a 13-year-old girl undergoing changes in the refraction of her OS associated with eye rubbing. Corneal topography showed a corneal deformation in OS, classified as stage 1 keratoconus according to the Krumeich classification. A significant reduction in eye rubbing led to a normal corneal shape at the 1-year follow-up. Transient and fully reversible corneal ectasia can be caused by eye rubbing in pediatric age. This may have implications when counseling very young patients with eye rubbing.


Assuntos
Córnea/patologia , Topografia da Córnea , Ceratocone/diagnóstico , Massagem/efeitos adversos , Adolescente , Dilatação Patológica , Feminino , Seguimentos , Humanos , Ceratocone/etiologia , Ceratocone/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA