Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38159804

RESUMO

INTRODUCTION: The improved image resolution of IMAGE1 S technology will increase tumor detection, achieve a greater number of complete resections, and would probably have an impact on the reduction of recurrences. AIM: The primary objective was to compare the recurrence rates of IMAGE1 S vs. white light during transurethral resection of the bladder (TUR); the secondary objective was to compare the complication rates according to Clavien-Dindo (CD) at 12 months of follow-up. METHODS: Prospective, randomized 1:1, blinded clinical trial. Recurrence and complication rates according to CD were analyzed using chi-square/U Mann-Whitney tests and recurrence-free survival (RFS) using Kaplan-Meier curves. The European Association of Urology (EAU) 2021 scoring model was used. RESULTS: The analysis included 103 participants; 49 were assigned to the IMAGE1 S group and 54 to the white light group. Recurrence rates were 12.2% and 25.9%, respectively (P = .080). The low and intermediate risk group had a lower recurrence rate with IMAGE1 S (7.7% vs. 30.8%, P = .003) and a higher RFS with IMAGE1 S (85.2% vs. 62.8% Log Rank: 0.021), with a Hazard Ratio of 0.215 (95% CI: 0.046-0.925). No differences were observed in the high and very high-risk groups. Complications were mostly grade I and rates were similar between both groups (IMAGE1 S 20.4% vs. white light 7.4% P = .083). CONCLUSIONS: There were no differences in the recurrence rates between groups. However, the low and intermediate risk group had a lower recurrence rate with IMAGE1 S. In addition, perioperative complication rates were not higher.

2.
Actas Urol Esp (Engl Ed) ; 46(1): 16-21, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34844902

RESUMO

INTRODUCTION: Training in experimental models is a valid option that improves the outcomes and shortens surgical learning curves. Our objective was to develop a 3D printed plastic model for teaching, training and education in flexible ureteroscopy, analyzing costs and suitability for the practice of this surgical technique. METHODS: A 3D printed model was developed based on a CT scan from a real-life patient's upper urinary tract. Horos™ software was used for segmentation and an FDM-Ultimaker for 3D printing. Renal calyces were numbered to be identified, as in the European Association of Urology Endoscopic Stone Treatment training curriculum, Task 4. The following were used: Innovex single-use flexible ureteroscope (Palex) and nitinol baskets (Coloplast). RESULTS: Printing time was 19 h, with a total cost of €8.77. The three-dimensional model allowed the insertion of the flexible ureteroscope and the exploration of the renal calyces by urologists in training as well as in current practice of the specialty without difficulty. The model also allowed the use of baskets and the mobilization and removal of previously placed stones. CONCLUSION: We unveil a valid three-dimensional model for flexible ureteroscopy training exercises with reasonable costs, which will allow acquiring the necessary skills and confidence to initiate the procedure in a real-life scenario.


Assuntos
Ureteroscópios , Urologia , Humanos , Impressão Tridimensional , Ureteroscopia , Urologistas
3.
Actas Urol Esp (Engl Ed) ; 44(9): 617-622, 2020 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32650954

RESUMO

INTRODUCTION: The global pandemic of COVID-19 has led to rapid implementation of telemedicine, but there is little information on patient satisfaction of this system as an alternative to face-to-face care. OBJECTIVE: To evaluate urological patient satisfaction with teleconsultation during the COVID-19 pandemic. MATERIAL AND METHODS: Observational, prospective, cross-sectional, non-interventional study carried out by telephone survey during the period considered as the peak of the pandemic (March-April 2020). A quality survey composed of 11 questions on urological care provided by physicians during the COVID-19 pandemic was conducted, selecting a representative sample of patients attended by teleconsultation. RESULTS: Two hundred patients were contacted by telephone to answer a survey on the quality of teleconsultation. The distribution of patients surveyed among the specialized consultations was homogeneous with the number of consultations cited in the period; 18% of them required assistance from family members. Sixty percent of patients avoided going to a medical center during the pandemic. Of the surveyed patients, 42% had cancelled diagnostic tests, 59% had cancelled medical consultations, 3.5% had cancelled treatments and 1% had cancelled interventions. Ten percent reported a worsening of urological symptoms during confinement. According to physicians, consultations were effectively delivered in 72% of cases, with teleconsultation being carried out by their usual urologist in 81%. Teleconsultation overall satisfaction level was 9 (IQI8-10), and 61.5% of respondents consider teleconsultation as a «health care option¼ after the healthcare crisis. CONCLUSION: Teleconsultation has been evaluated with a high level of satisfaction during the COVID-19 pandemic, offering continuous care to urological patients during the healthcare crisis. The perceived quality offers a field of optional telematic assistance in selected patients, which should be re-evaluated in a period without confinement measures.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Satisfação do Paciente/estatística & dados numéricos , Pneumonia Viral/epidemiologia , Consulta Remota/estatística & dados numéricos , Doenças Urológicas/psicologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Agendamento de Consultas , COVID-19 , Estudos Transversais , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Prospectivos , Qualidade da Assistência à Saúde , SARS-CoV-2 , Inquéritos e Questionários , Adulto Jovem
4.
Actas Urol Esp (Engl Ed) ; 44(3): 148-155, 2020 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31866160

RESUMO

Prostate cancer (PCa) is the second leading cause of cancer-related mortality and the most frequently diagnosed male malignant disease among men. The manifestation of PCa ranges from indolent to highly aggressive disease and due to this high variation in PCa progression, the diagnosis and subsequent treatment planning can be challenging. The current diagnostic approach with PSA testing and digital rectal examination followed by transrectal ultrasound biopsies lack in both sensitivity and specificity in PCa detection and offers limited information about the aggressiveness and stage of the cancer. Scientific work supports the rapidly growing use of multiparametric magnetic resonance imaging as the most sensitive and specific imaging tool for detection, lesion characterization and staging of PCa. Therefore, we carried out an updated review of magnetic resonance imaging in the diagnostic PCa reviewing the latest papers published in PubMed.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Europa (Continente) , Previsões , Humanos , Masculino , Guias de Prática Clínica como Assunto , Sociedades Médicas , Urologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA